992 resultados para Equipment testing


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

An analysis of the performances of three important methods for generators and loads loss allocation is presented. The discussed methods are: based on pro-rata technique; based on the incremental technique; and based on matrices of circuit. The algorithms are tested considering different generation conditions, using a known electric power system: IEEE 14 bus. Presented and discussed results verify: the location and the magnitude of generators and loads; the possibility to have agents well or poorly located in each network configuration; the discriminatory behavior considering variations in the power flow in the transmission lines. © 2004 IEEE.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The need for a rational use of water and supply of food for a growing world population have led to the development of research in the area of irrigation systems. Thus, some irrigation systems which join efficiency with low cost of material have been developed. Although some technical characteristics are provided by the manufacturers, tests are required to verify functioning of the system and uniformity of water distribution. Continuous research on uniformity, characteristics of the materials and design of water distribution systems is essential for system improvement. Therefore, the objective of this work was to evaluate the CV (manufacturer's coefficient of variation) of Amanco microsprinkler (1.0 mm light green nipple) using bench testing in the laboratory of Irrigation at UNESP - FCA campus of Botucatu-SP. Twenty-five microsprinklers in a sequential design were used in the tests. Three flow systems were tested as follows: a Coil system based on serial connected pipes; a Lateral system, the most common system in which secondary lines are fed by a main line; and a Mesh system used in the urban water supply. The results showed that 4.17% CVf met the production standards and the Lateral and Mesh systems were similar regarding outflow using bench testing. The Mesh system presented the highest mean value of outflow and the lowest range of variation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This work presents a case study on technology assessment for power quality devices. A system compatibility test protocol for power quality mitigation devices was developed in order to evaluate the functionality of three-phase voltage restoration devices. In order to case test this test protocol, a development platform with reduced power for DVR (Dynamic Voltage Restorer), the Micro-DVR, was tested, and results were discussed based on voltage disturbances standards. ©2008 IEEE.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Using robots for teaching is one approach that has gathered good results on Middle-School, High-School and Universities. Robotics gives chance to experiment concepts of a broad range of disciplines, principally those from Engineering courses and Computer Science. However, there are not many kits that enables the use of robotics in classroom. This article describes the methodologies to implement tools which serves as test beds for the use of robotics to teach Computer Science and Engineering. Therefore, it proposes the development of a flexible, low cost hardware to integrate sensors and control actuators commonly found on mobile robots, the development of a mobile robot device whose sensors and actuators allows the experimentation of different concepts, and an environment for the implementation of control algorithms through a computer network. This paper describes each one of these tools and discusses the implementation issues and future works. © 2010 IEEE.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Ultrasonic sound velocity measurements with hand-held equipment remain due to their simplicity among the most used methods for non-destructive grading of sawn woods, yet a dedicated normalization effort with respect to strength classes for Spanish species is still required. As part of an ongoing project with the aim of definition of standard testing methods, the effect of the dimensions of commonly tested Scots pine (Pinus sylvestris L.) timbers and equipment testing frequency on ultrasonic velocity were investigated. A dedicated full-wave finite-difference time-domain software allowed simulation of pulse propagation through timbers of representative length and section combinations. Sound velocity measurements vL were performed along the grain with the indirect method at 22 kHz and 45 kHz for grids of measurement points at specific distances. For sample sections larger than the cross-sectional wavelength ?RT, the simulated sound velocity vL converges to vL = (CL/?)0.5. For smaller square sections the sound velocity drops down to vL = (EL/?)0.5, where CL, EL and ? are the stiffness, E-modul and density, respectively. The experiments confirm a linear regression between time of flight and measurement distance even at less than two wavelength menor que2?L distance, the fitted sound speed values increased by 15% between the two tested frequencies.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Traction is recognised as an important component of the overall playability and safety of a sportsfield. It relates to the "grip", or footing, provided through an athlete's shoe when in contact with the surface, and is normally measured by the torque generated when a weighted studded disc apparatus is dropped onto the turf and twisted manually. This paper describes the development of an automated traction tester, which mechanises the dropping and twisting of the weighted studded disc. By standardising these operational stages, more repeatable and reliable results can be expected than from the original hand-operated design where positioning of the disc and speed of rotation are controlled manually and so can vary from one measurement to the next. As well as measuring the maximum torque reached during rotation of the studded disc, the automated traction tester generates a profile of torque showing changes over time and calculates the angle through which the studded disc moved before reaching maximum torque. These aspects are now covered by a utility patent (PAT/AU/2004270767). Use of the automated traction tester is illustrated by comparative data for a range of warm-season turfgrasses, by comparisons of traction under different surface conditions generated by wear on Cynodon dactylon cultivars, and by the effects of environment, management and playing patterns on traction across a multi-use sports stadium.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Damages -reduced in fruit packing lines is a major cause of grace reduction and quality loos in fresh marks: fruit. Fruit must be treated gently during in sir handling to improve their qualityin order to get a good price in a competitive market. The correct post-hardvest handling in fruit packing lines is a prerequisite to cut down the heavy post-harvest losses. Fruit packing lines must be evaluated, studying their design, the impacts applied to the fruits, the characteristics of the materials, etc. This study establishes the possibility of carrying out modifications and tests in a packing line during a long period of time. For this purpose, an experimental fruit packing line has been designed and located in the Agricultural Engineering Department of the Polythecnic University of Madrid with the aim of improving mechanical devices and fruit handling conditions to minimize damage to fruit. The experimental line consists of several transporting belts, one rollers transporter, one sizer, one elevator, one singularizer, and three trays to receive the calibrated fruit. The line has a length of 6.15 m and a width cf 1.9 m. Movement of the different components is regulated by electric motors with variable velocity electronically controlled. The height of the transfer points is variable and can be easily modified. The experimental line has been calibrated using two instrumented spheres IS 100 (8.8 cm Ø and6.2cm Ø). Average acceleration values obtained in all the transfers of the experimental line lay under 80 g's, although there is big variation for some of them being some values above 100 g's.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Actual system performance of a PV system can differ from its expected behaviour.. This is the main reason why the performance of PV systems should be monitored, analyzed and, if needed, improved on. Some of the current testing procedures relating to the electrical behaviour of PV systems are appropriated for detecting electrical performance losses, but they are not well-suited to reveal hidden defects in the modules of PV plants and BIPV, which can lead to future losses. This paper reports on the tests and procedures used to evaluate the performance of PV systems, and especially on a novel procedure for quick on-site measurements and defect recognition caused by overheating in PV modules located in operating PV installations.