972 resultados para Equipment contamination
Resumo:
A burn patient was infected with Acinetobacter baumannii on transfer to the hospital after a terrorist attack. Two patients experienced cross-infection. Environmental swab samples were negative for A. baumannii. Six months later, the bacteria reemerged in 6 patients. Environmental swab samples obtained at this time were inoculated into a minimal mineral broth, and culture results showed widespread contamination. No case of infection occurred after closure of the unit for disinfection.
Resumo:
In Switzerland, individuals exposed to the risk of activity intake are required to perform regular monitoring. Monitoring consists in a screening measurement and is meant to be performed using commonly available laboratory instruments. More particularly, iodine intake is measured using a surface contamination monitor. The goal of the present paper is to report the calibration method developed for thyroid screening instruments. It consists of measuring the instrument response to a known activity located in the thyroid gland of a standard neck phantom. One issue of this procedure remains that the iodine radioisotopes have a short half-life. Therefore, the adequacy and limitations to simulate the short-lived radionuclides with so-called mock radionuclides of longer half-life were also evaluated. In light of the results, it has been decided to use only the appropriate iodine sources to perform the calibration.
Resumo:
Laboratory cross-contamination by Mycobacterium tuberculosis is known to be responsible for the misdiagnosis of tuberculosis, but its impact on other contexts has not been analyzed. We present the findings of a molecular epidemiology analysis in which the recent transmission events identified by a genotyping reference center were overestimated as a result of unnoticed laboratory cross-contamination in the original diagnostic laboratories.
Resumo:
Purpose: To determine the incidence of Piry virus contamination among surgical instruments used with disposable accessories for phacoemulsification during sequential surgeries. Methods: An experimental model was created with 4 pigs' eyes that were contaminated with Piry virus and 4 pigs' eyes that were not contaminated. Phacoemulsification was performed on the eyes, alternating between the contaminated and non-contaminated eyes. From one surgery to another, the operating fields, gloves, scalpel, tweezers, needles, syringes, tips and bag collector from the phacoemulsification machine were exchanged; only the hand piece and the irrigation and aspiration systems were maintained. Results: In the collector bag, three samples from the contaminated eyes (3/4) were positive, and two samples from the non-contaminated (2/4) eyes were also positive; at the tip, one sample from the contaminated eyes (1/4) and two samples of the noncontaminated eyes (2/4) yielded positive results. In the irrigation system, one sample from a non-contaminated eye (1/4) was positive, and in the aspiration system, two samples from contaminated eyes (2/4) and two samples from non-contaminated eyes (2/4) were positive. In the gloves, the samples were positive in two samples from the non-contaminated eyes (2/4) and in two samples from the contaminated eyes (2/4). In the scalpel samples, three contaminated eyes (3/4) and none of the non-contaminated eyes (0/4) were positive; finally, two samples from the anterior chambers of the non-contaminated eyes gathered after surgery were positive. Conclusions: In two non-contaminated eyes, the presence of genetic material was detected after phacoemulsification surgery, demonstrating that the transmission of the genetic material of the Piry virus occurred at some point during the surgery on these non-contaminated eyes when the hand piece and irrigation and aspiration systems were reused between surgeries.
Resumo:
The systematic collection of behavioural information is an important component of second-generation HIV surveillance. The extent of behavioural surveillance among injecting drug users (IDUs) in Europe was examined using data collected through a questionnaire sent to all 31 countries of the European Union and European Free Trade Association as part of a European-wide behavioural surveillance mapping study on HIV and other sexually transmitted infections. The questionnaire was returned by 28 countries during August to September 2008: 16 reported behavioural surveillance studies (two provided no further details). A total of 12 countries used repeated surveys for behavioural surveillance and five used their Treatment Demand Indicator system (three used both approaches). The data collected focused on drug use, injecting practices, testing for HIV and hepatitis C virus and access to healthcare. Eight countries had set national indicators: three indicators were each reported by five countries: the sharing any injecting equipment, uptake of HIV testing and uptake of hepatitis C virus testing. The recall periods used varied. Seven countries reported conducting one-off behavioural surveys (in one country without a repeated survey, these resulted an informal surveillance structure). All countries used convenience sampling, with service-based recruitment being the most common approach. Four countries had used respondent-driven sampling. Three fifths of the countries responding (18/28) reported behavioural surveillance activities among IDUs; however, harmonisation of behavioural surveillance indicators is needed.
Resumo:
Mechanically ventilated patients in hospitals are subjected to an increased risk of acquiring nosocomial pneumonia that sometimes has a lethal outcome. One way to minimize the risk could be to make the surfaces on endotracheal tubes antibacterial. In this study, bacterial growth was inhibited or completely prevented by silver ions wet chemically and deposited onto the tube surface. Through the wet chemical treatment developed here, a surface precipitate was formed containing silver chloride and a silver stearate salt. The identity and morphology of the surface precipitate was studied using x-ray photoelectron spectroscopy, Fourier transform infrared spectroscopy, scanning electron microscopy, and x-ray powder diffraction. Leaching of silver ions into solution was examined, and bacterial growth on the treated surfaces was assayed using Pseudomonas aeruginosa wild type (PAO1) bacteria. Furthermore, the minimum inhibitory concentration of silver ions was determined in liquid- and solid-rich growth medium as 23 and 18 microM, respectively, for P. aeruginosa.
Resumo:
OBJECTIVE: To evaluate the efficacy and safety of intravenous fluconazole for the prevention of intra-abdominal Candida infections in high-risk surgical patients. DESIGN: Randomized, prospective, double-blind, placebo-controlled study. SETTING: Two university-affiliated hospitals in Switzerland. PATIENTS: Forty-nine surgical patients with recurrent gastrointestinal perforations or anastomotic leakages. INTERVENTIONS: Prophylaxis with intravenous fluconazole (400 mg per day) or placebo continued until resolution of the underlying surgical condition. MEASUREMENTS AND MAIN RESULTS: Patients were evaluated daily, and specimens for culture were obtained three times per week during prophylaxis. The primary study end points were the frequency of and the time to intra-abdominal Candida infections. Secondary end points were the frequency of candidiasis (intra-abdominal and extra-abdominal) and the emergence or persistence of Candida colonization. Among patients who were not colonized at study entry, Candida was isolated from surveillance cultures during prophylaxis in 15% of the patients in the fluconazole group and in 62% of the patients in the placebo group (relative risk, 0.25; 95% confidence interval, 0.07 to 0.96; p = .04). Candida peritonitis occurred in one of 23 patients (4%) who received fluconazole and in seven of 20 patients (35%) who received placebo (relative risk, 0.12; 95% confidence interval, 0.02 to 0.93; p = .02). In addition, one catheter-related Candida albicans sepsis occurred in a fluconazole-treated patient. Thus, overall, candidiasis developed in two fluconazole patients and seven placebo patients (relative risk, 0.25; 95% confidence interval, 0.06 to 1.06; p = .06). C. albicans accounted for 87% of the Candida species isolated before or during prophylaxis, and all C. albicans strains were susceptible to fluconazole. Fluconazole was well tolerated, and adverse events occurred at similar frequencies in both treatment groups. CONCLUSIONS: Fluconazole prophylaxis prevents colonization and invasive intra-abdominal Candida infections in high-risk surgical patients.
Resumo:
Primary bloodstream infection (BSI) is a leading, preventable infectious complication in critically ill patients and has a negative impact on patients' outcome. Surveillance definitions for primary BSI distinguish those that are microbiologically documented from those that are not. The latter is known as clinical sepsis, but information on its epidemiologic importance is limited. We analyzed prospective on-site surveillance data of nosocomial infections in a medical intensive care unit. Of the 113 episodes of primary BSI, 33 (29%) were microbiologically documented. The overall BSI infection rate was 19.8 episodes per 1,000 central-line days (confidence interval [CI] 95%, 16.1 to 23.6); the rate fell to 5.8 (CI 3.8 to 7.8) when only microbiologically documented episodes were considered. Exposure to vascular devices was similar in patients with clinical sepsis and patients with microbiologically documented BSI. We conclude that laboratory-based surveillance alone will underestimate the incidence of primary BSI and thus jeopardize benchmarking.
Resumo:
The aim of this investigation was to evaluate the cleaning effect of CO 2 on surface topography and composition of failed dental implant surfaces. Ten failed dental implants were retrieved from nine patients (mean age, 46.33 ± 5.81 years) as a result of early or late failure. The implants were divided into two parts: one side of the implant was irradiated with a CO 2 laser (test side), while the other side did not receive irradiation (control side). The CO 2 laser was operated at 1.2 W in a continuous wave for 40 seconds (40 J energy). The handpiece of the CO 2 laser was kept at a distance of 30 mm from the implant surface, resulting in a spot area of 0.031415 cm 2 (38.20 W/cm 2; 1559 J/cm 2) in scanning mode (cervical-apical). One unused dental implant was used as a negative control for both groups. All implant surfaces were examined by scanning electron mi croscopy (SEM) and energy-dispersive spectrometer x-ray (EDS) for element analysis. SEM showed that the surface of the test sides consisted of different degrees of organic residues, appearing mainly as dark stains similar to those observed on the control sides. None of the test surfaces presented alterations such as crater-like alterations, lava-like layers, or melting compared with the nonirradiated surfaces. Foreign elements such as carbon, oxygen, sodium, calcium, and aluminum were detected on both sides. These results suggest that CO 2 laser irradiation does not modify the implant surface, although the cleaning effect was not satisfactory.
Resumo:
This study evaluated the effect of microwave energy on the hardness, impact strength and flexural strength of the Clássico, Onda-Cryl and QC-20 acrylic resins. Aluminum die were embedded in metallic or plastic flasks with type III dental stone, in accordance with the traditional packing technique. A mixing powder/liquid ratio was used according to the manufacturer's instructions. After polymerization in water batch at 74°C for 9 h, boiling water for 20 min or microwave energy at 900 W for 10 min, the specimens were deflasked after flask cooling at room temperature, and submitted to finishing. Specimens non-disinfected and disinfected by microwave irradiation were submitted to hardness, impact and flexural strength tests. Each specimen was immersed in distilled water and disinfected in a microwave oven calibrated to 650 W for 3 min. Knoop hardness test was performed with 25 g load for 10 s, impact test was carried out using the Charpy system with 40 kpcm, and 3-point bending test with a crosshead speed of 0.5 mm/min until fracture. Data were submitted to statistical analysis by ANOVA and Tukey's test (α=0.05). Disinfection by microwave energy decreased the hardness of Clássico and Onda-Cryl acrylic resins, but no effect was observed on the impact and flexural strength of all tested resins.
Resumo:
The aim of this paper was to evaluate the antimicrobial activity of 2% chlorhexidine gel (CLX) associated with various intracanal medicaments against Candida albicans and Enterococcus faecalis inoculated in root canals. Thirty six human single-rooted teeth were contaminated with C.albicans and E.faecalis. The canals were instrumented using 2% CLX gel and were divided into three groups according to the intracanal medicaments (ICM) used. Group 1: calcium hydroxide paste [Ca(OH)], Group 2: 2% chlorhexidine gel (CLX) and Group 3: 2% CLX gel + Ca(OH). The root canal collections were performed after 21 days of contamination (control collection), after instrumentation (1st collection), after 14 days of intracanal medicament (2nd collection) and 7 days after medicament removal (3rd collection). The microbiological samples were plated in culture media and incubated for 48 hours. The results were submitted to Kruskal-Wallis test (P ≤ 0.05). It was verified that the instrumentation with CLX reduced the number of CFU/ml significantly when compared with the confirmation collection (control). However, the use of the ICM was only capable to eliminate completely the microorganisms in the root canals without difference statistics between them. Although the use of 2% chlorherixidine gel reduces the number of microorganisms significantly, only the ICM calcium hydroxide and calcium hydroxide associated with chlorhexidine are able to eliminate these microorganisms completely.
Resumo:
OBJECTIVE: To verify the existence of fungal contamination prior to and following the cleaning and disinfection process of hospital mattresses used by patients with Candidemia. METHODS: Cross-sectional study analyzing 25 mattresses used by patients with Candidemia confirmed by blood culture from different hospital wards. The study made use of convenience samples. After growing the samples in an Agar Sabouraud Dextrose environment, isolated yeasts were identified by macroscopic, microscopic and physiologic characteristics. RESULTS: Analyses showed 15 (60%) mattresses contaminated by Candida spp. From these, 10 (66.7%) and five (33.3%) mattresses corresponded respectively to the collection prior to and following disinfection, with Candida parapsilosis being the isolated species with the highest frequency. CONCLUSION: Considering that half of the mattresses remained contaminated after cleaning and disinfection, there is a risk that these mattresses may act as potential secondary reservoirs in the infection chain.