999 resultados para Equipamentos odontológicos de alta rotação


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This is study proposes to evaluate the ergonomic aspects of dental equipments. Based on the characteristics proposed by ISO/FDI, on the existing literature and related researches an evaluating system was devised. Thirty nine dental clinics were examined using the 165 pointssystem proposed, distributed in 12 criteria. None of the dental clinics examined showed a bad ergonomics level, 41% were good and 59% reached excellent levels. The point-supported evaluation system proposed is effective in the analysis of the ergonomic conditions of dental equipments, allowing a quantification of their characteristics. Using this system, the dentist can also know the level of ergonomic satisfaction existing in his equipment, and identify the conditions to be improved. It was concluded that the equipment belonging to dental workplaces evaluated had excellent level of compliance, however corrective measures are needed since even the presence of a few non-conforming items is a sufficient condition to cause injury to users, decreased efficiency and comfort and loss quality of service

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to compare temperature increases produced by a well-known equipment, the high-speed handpieces, with a relatively new instrument, the Er:YAG laser (350 mJ/10 Hz). Thirty-five bovine mandibular incisors, which were reduced to an enamel/dentin thickness of 2,5 mm, were used. Cavity preparation was done till a depth of 2, 5 mm. A thermocouple was placed to read the temperature inside of the pulp chamber. Analysis was performed in these groups: I - high-speed handpiece without water-cooling (n=10); II - high-speed handpiece with water-cooling (n=10); III - Er:YAG laser without water-cooling (n=5); IV- Er:YAG laser with water-cooling (n=10) Group III had only 5 teeth because it was impossible to properly make the cavity preparations by the laser equipment without water cooling. The temperature increases were recorded in a computer linked to the thermocouples and the data of the groups I, II and IV were submitted to Dunn's multiple comparison test (p<0,05). The medium temperature increases were: 11,64ºC for group I, 0,96ºC for group II, 40,86ºC for group III and 2,9°C for group IV. There were no statistical differences between groups lI and IV, and these were different from group I. The cavity preparations made by the high-speed and the laser equipment generated very similar heat increases under water-cooling. The water-cooling is essential to avoid aggressive temperature increases, both when using the high-speed and the laser equipment, and with laser it is especially necessary for ablation of enamel

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A extração de dentes inclusos pode ser realizada utilizando diferentes técnicas cirúrgicas, senda a odontossecção com o uso de instrumentos rotatórios a mais utilizada nos dias atuais com o uso das turbinas de alta rotação. Recentemente têm sido empregado o aparelho de ultra-som para a realização da odontossecção e da osteotomia nas cirurgias bucais, justificando o seu uso por promoverem uma maior segurança aos tecidos moles adjacentes e promoverem um corte mais preciso. Objetivo: A proposta deste estudo é comparar, in vitro, a eficácia das pontas diamantadas acopladas ao ultrassom quando comparadas às pontas diamantadas acopladas no motor de alta-rotação durante o seccionamento de terceiros molares inferiores e nas técnicas de osteotomias. Metodologia: 45 terceiros molares inferiores humanos hígidos foram incluídos em resina acrílica transparente para padronização da posição desejada durante o corte utilizando a turbina de alta rotação, o aparelho de ultra-som ou a associação de ambos. Os tempos de odontossecção e osteotomia foram calculados a comparados entre os diferentes grupos. Resultados: Durante a odontossecção o grupo ultra-som apresentou tempo médio bem acima dos outros grupos, demonstrando haver diferença estatisticamente significante em relação aos grupos alta-rotação e alta-rotação+ultra-som (p0.05). Quando analisado o tempo gasto para a osteotomia, não foram observadas diferenças estatisticamente significantes entre os 3 grupos (p>0,05). Conclusões: A utilização dos métodos em associação (alta-rotação+ultra-som) apresenta-se como uma opção segura e rápida para os procedimentos de osteotomia e odontossecção, possibilitando uma maior segurança aos tecidos adjacentes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Nine swines of the White Large race were used for study of the process of bony repair after osteotomy with rotating instruments of low and high-speed, with and without liquid refrigeration. The authors observed, through double blind histopathological analysis, that in every analyzed operative time, the bony repair was processed more appropriately when the osteotomies were accomplished with liquid refrigeration. In the final postoperative times, of fourteen and twenty-eight days, the best results of bony repair were observed in the osteotomy accomplished with drills of low rotation and with liquid refrigeration, while in the postoperative time of seven days, the results of the bony repair of osteotomy accomplished with drills of high rotation and with liquid refrigeration they were better. The authors consider, still, that the process of bony repair in swine display larger proximity in the histological pictures among the studied variables, when compared with other biological models. As most of the works told in the literature it refers the use of dogs, the authors consider that the present work guarantees your importance in the sense of looking for a closer model of the man.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The connection between rotation, CaII emission flux and lithium abundance is analyzed for a sample of subgiant stars, with evolutionary status was determined from the Toulouse-Geneve code and HlPPARCOS trigonometric parallax measurements. We noted that the distribution of rotation and CaII emission flux, as a function of effective temperature, shows a discontinuity located around the same spectral type, F8IV. Stars located blueward of this spectral type, exhibit a large spread of values of rotation and CaII flux, whereas stars redward of F8lV show essentially low ratation anel low CaII flux. The strength of these declines nevertheless, depends on stellar mass. The distribution of lithium abundances also shows a discontinuity, however with behavior a little more complex for subgiants with mass lower than about 1.2 Solar Masses, this decrease is observed later than that in rotation and CaII flux, whereas for masses higher than 1.2 Solar Masses the decrease in lithium abundance is located around the spectral type F8IV. The discrepancy between the location of the discontinuities of rotation and CaII flux and log n(Li) for stars with masses lower than 102 Solar Masses, seems to reflect the sensitivity of these phenomena to the mass of the convective envelope. The drop in rotation, which results mostly from a magnetic braking, requires an increase in the mass of the convective envelope less than that required for the decrease in lithium abundance The location of the discontinuity in log n( Li) in the same region of the discontinuity ties in rotation and CaII flux, for stars with masses higher than 1.2 Solar Masses, may also be explained by the behavior of the deepening of the convective envelope. In contrast to the relationship between rotation and CaII flux the relationship between lithium abundance and rotation shows no dear tendency toward linear behavior. Similarly, the same tendency is observed in the relationship between lithium abundance and CaII flux in spite of these facts, subgiants with high lithium content also have high rotation and high CaII emission flux. We also observed that stars with high lithium content present, in its majority, an undeveloped convective envelope, whereas stars with low lithium content have a developed convective envelope. In the case of the rotation, stars with undeveloped convective envelope, show rotational velocities as much high as low, whereas stars with developed convective envelope only present low rotation