982 resultados para Energia direta - Conversão


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work, based in a patent request at INPI, protocol no. 020110035974, presents a system development using solar panels to supply the electricity demand required by punctual loads, without a storage unit or utility grid synchronism, through a control circuit that allows parallel operation with the power grid during low sunlight incidence periods. A study about solar panel construction and topologies for Power generation was done, in a atempt to evalute impacts in project. This development was modular, providing the system the possibility of power capacity expansion and load diversity as well, in an attempt to reduce the total energy requirements from the residential sector drained from the power grid along the day

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Mecânica, 2016.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Energia na Agricultura) - FCA

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Energia na Agricultura) - FCA

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Energia na Agricultura) - FCA

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Energia na Agricultura) - FCA

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Energia na Agricultura) - FCA

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Energia na Agricultura) - FCA

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The study evaluated the energy balance of the yellow passion fruit (Passiflora edulis Sims) production system in the region of Marilia-SP. There were analyzed the "inputs" of energy originated from biological, fossil, and industrial sources, and the "output" of energy in the form of fruits produced per unit area, as well as five energy indicators. The phytotechnical indices considered were: planting in February (seedling in tubes), production cycle: 18 months, and yield: 20 t/ha. The input energy totaled 173,707.86 MJ/ha. The most representative items corresponded to industrial indirect energy (38%) and to biological (34%). Chemical fertilizers and pesticides accounted for 65% and 31% of indirect energy industry, respectively. The activity generated 391,800.00 MJ per cycle/ha, and the culture productivity, 0.12 MJ/kg. The efficiency of the culture was 2.26. The net cultural energy totaled 218,092.15 MJ/ha. The energy balance was positive (126,050.23 MJ/ha). Energy efficiency was favorable, with a value of 3.64. The direct power consumption of fossil origin is significant in the system evaluated, but it still allows the production of the yellow passion fruit in an environmentally sustainable way.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The aim of this work was to proceed, from the energetic point of view, an analysis of a corn agroecosystem, on the direct planting, located at Pirituba II rural workers placement project, Área III, city of Itaberá/SP. The energetic analysis mesured all operations, together with its fisical demands, the inputs and produced grains, classifying them within their respective flux, based on the definition of energy inputs and outputs, converting them into energetic equivalents and, so, determining the energetic matrix of de agroecosystem. The caloric index used were cultural efficiency and cultural liquid energy. The results showed the dependence of the studied systems on the chemical energy sources, from fertilizers (39,49%), agrotoxics (27,74%), and fossile energy of diesel (24,94%). The energetic values of the direct and indirect energy showed a very big difference between them, what means that the energy sources used in the system are not balanced. The cultural efficiency found was 12,86 and cultural liquid energy got to 115.025,92 MJ x ha-1. Later on, obtained data was compared to already existing data in Bueno (2002), who researched conventional planting system. The cultural inputs of both systems were energeticaly different: 9.696,97 MJ x ha-1 (direct planting), e 8.783,78 MJ x ha-1 (convencional planting). The outputs had very different results: 124.722,89 e 79.118,38 MJ x ha-1, respectively. So, we had much more cultural liquid energy on the studied system: 115.025,92 MJ x ha-1, compared to convencional system: 70.334,60 MJ x ha-1. The energectic loss of nitrogened fertilizers contributed for the high energetic loss of both energetic studied matrices. There are few contribution from biological energy source in both systems.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Este estudo consiste na caracterização da eficiência energética de uma bomba de calor de expansão direta que utiliza a energia solar como fonte térmica. De uma forma geral, teve-se a obrigação de procurar cada vez mais recursos renováveis e neste sentido a bomba de calor de expansão direta tem um papel importante no aquecimento de águas quentes sanitárias (AQS). Como ponto de partida, foi realizada uma descrição detalhada sobre todos os equipamentos da bomba de calor e elaborado um desenho técnico que identifica todos os componentes. No laboratório (casa inteligente) realizaram-se vários ensaios a fim de interpretar com rigor os resultados obtidos do desempenho da bomba de calor (COP) e do fator médio de desempenho sazonal (SPF). No início, realizaram-se ensaios para determinar as perdas estáticas do sistema termodinâmico, de seguida foram elaborados ensaios segundo a norma EN 16147 e por fim, ensaios de acordo com o perfil de utilização de AQS definido. No estudo experimental do COP, obteve-se uma elevada eficiência energética com um valor médio de 4,12. O COP aumenta para valores médios de 5 quando a temperatura de água no termoacumulador desce para 35ºC. Verificou-se que durante o período diurno o COP aumenta aproximadamente de 10% relativamente ao período noturno. A potência elétrica é mais elevada (450W) quando a água no termoacumulador está perto da temperatura desejável (55ºC), originando um esforço maior da bomba de calor. No estudo experimental do SPF, verificou-se que nos ensaios segundo a norma EN16147 os valores obtidos variaram entre 1,39 e 1,50 (Classe “B”). No estudo realizado de acordo com o perfil de utilização de AQS definido pelo utilizador, o SPF é superior em 12% relativamente ao obtido segundo os ensaios realizados de acordo a norma EN16147. Verificou-se que o aumento da temperatura do ar exterior implica um aumento do SPF (cerca de 2% a 5%), enquanto a energia solar não influência nos resultados.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Desde muito cedo, na história da humanidade, que a energia eólica é aproveitada pelo homem, primeiro sob a forma de energia mecânica e mais recentemente sob a forma de energia elétrica. O crescimento rápido do consumo de eletricidade, no final do século XIX, motivou a aplicação do princípio de funcionamento dos tradicionais moinhos de vento à conversão da energia eólica em energia elétrica. No entanto, foi após os choques petrolíferos da década de 1970 que as atividade de Investigação e Desenvolvimento (I&D) se intensificaram de forma significativa conduzindo à instalação das primeiras turbinas eólicas comerciais no início da década de 1980 na Europa e nos EUA. Desde então, as tecnologias de conversão da energia eólica têm registado um desenvolvimento considerável que se estende desde as técnicas de construção cada vez mais robustas até à utilização de sistemas de conversão com possibilidade de serem explorados em velocidade variável, com consequências refletidas ao nível do aumento progressivo da potência unitária instalada e da diminuição do custo do kWh gerado.