988 resultados para Endotracheal-tube Length


Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Despite numerous studies on endotracheal tube cuff pressure (CP) management, the literature has yet to establish a technique capable of adequately tilling the cuff with an appropriate volume of air while generating low CP in a less subjective way. the purpose of this prospective study was to evaluate and compare the CP levels and air volume required to fill the endotracheal tubes cuff using 2 different techniques (volume-time curve versus minimal occlusive volume) in the immediate postoperative period after coronary artery bypass grafting. METHODS: A total of 267 subjects were analyzed. After the surgery, the lungs were ventilated using pressure controlled continuous mandatory ventilation, and the same ventilatory parameters were adjusted. Upon arrival in the ICU, the cuff was completely deflated and re-inflated, and at this point the volume of air to fill the cuff was adjusted using one of 2 randomly selected techniques: volume-time curve and minimal occlusive volume. We measured the volume of air injected into the cuff, the CP, and the expired tidal volume of the mechanical ventilation after the application of each technique. RESULTS: the volume-time curve technique demonstrated a significantly lower CP and a lower volume of air injected into the cuff, compared to the minimal occlusive volume technique (P < .001). No significant difference was observed in the expired tidal volume between the 2 techniques (P = .052). However, when the subjects were submitted to the minimal occlusive volume technique, 17% (n = 47) experienced air leakage as observed by the volume-time graph. CONCLUSIONS: the volume-time curve technique was associated with a lower CP and a lower volume of air injected into the cuff, when compared to the minimal occlusive volume technique in the immediate postoperative period after coronary artery bypass grafting. Therefore, the volume-time curve may be a more reliable alternative for endotracheal tube cuff management.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Previous investigation showed that the volume-time curve technique could be an alternative for endotracheal tube (ETT) cuff management. However, the clinical impact of the volume-time curve application has not been documented. the purpose of this study was to compare the occurrence and intensity of a sore throat, cough, thoracic pain, and pulmonary function between these 2 techniques for ETT cuff management: volume-time curve technique versus minimal occlusive volume (MOV) technique after coronary artery bypass grafting. METHODS: A total of 450 subjects were randomized into 2 groups for cuff management after intubation: MOV group (n = 222) and volume-time curve group (n = 228). We measured cuff pressure before extubation. We performed spirometry 24 h before and after surgery. We graded sore throat and cough according to a 4-point scale at 1, 24, 72, and 120 h after extubation and assessed thoracic pain at 24 h after extubation and quantified the level of pain by a 10-point scale. RESULTS: the volume-time curve group presented significantly lower cuff pressure (30.9 +/- 2.8 vs 37.7 +/- 3.4 cm H2O), less incidence and intensity of sore throat (1 h, 23.7 vs 51.4%; and 24 h, 18.9 vs 40.5%, P < .001), cough (1 h, 19.3 vs 48.6%; and 24 h, 18.4 vs 42.3%, P < .001), thoracic pain (5.2 +/- 1.8 vs 7.1 +/- 1.7), better preservation of FVC (49.5 +/- 9.9 vs 41.8 +/- 12.9%, P = .005), and FEV1, (46.6 +/- 1.8 vs 38.6 +/- 1.4%, P = .005) compared with the MOV group. CONCLUSIONS: the subjects who received the volume-time curve technique for ETT cuff management presented a significantly lower incidence and severity of sore throat and cough, less thoracic pain, and minimally impaired pulmonary function than those subjects who received the MOV technique during the first 24 h after coronary artery bypass grafting.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To compare the efficacy of gentamicin, nebulised via the endotracheal tube (ET), with that of parenteral cefotaxime or parenteral cefuroxime in preventing the formation of ET biofilm.

Setting: General intensive care units in two university teaching hospitals.

Design: The microbiology of ET biofilm from 36 ICU patients eligible to receive antibiotic prophylaxis was examined. Peak and trough tracheal concentrations of gentamicin, cefotaxime or cefuroxime were measured in each patient group, on the 2nd day of intubation.

Patients: Twelve patients received gentamicin (80 mg) nebulised in 4 ml normal saline every 8 h, 12 cefotaxime (1 g, 12 hourly) and 12 cefuroxime (750 mg, 8 hourly). Prophylaxis was continued for the duration of intubation.

Measurements and results: Samples of tracheal secretions were taken on the 2nd day of ventilation for determination of antibiotic concentrations. Following extubation, ETs were examined for the presence of biofilm. Pathogens considered to be common aetiological agents for VAP included Staphylococcus aureus, enterococci, Enterobacteriaceae and pseudomonads. While microbial biofilm was found on all ETs from the cephalosporin group, microbial biofilm of these micro-organisms was found on 7 of the 12 ET tubes from patients receiving cefotaxime [S. aureus (4), pseudomonads (1), Enterobacteriaceae (1), enterococcus (1)] and 8 of the 12 ET tubes from patients receiving cefuroxime [Enterobacteriaceae (6), P. aeruginosa (1) and enterococcus (1)]. While microbial biofilm was observed on five ETs from patients receiving nebulised gentamicin, none of these were from pathogens for ventilator-associated pneumonia (VAP). Tracheal concentrations of both cephalosporins were lower than those needed to inhibit the growth of pathogens recovered from ET tube biofilm. The median (and range) concentrations for cefotaxime were 0.90 (<0.23–1.31) mg/l and 0.28 (<0.23–0.58) mg/l for 2 h post-dose and trough samples, respectively. Two hours post-dose concentrations of cefuroxime (median and range) were 0.40 (0.34–0.83) mg/l, with trough concentrations of 0.35 (<0.22–0.47) mg/l. Tracheal concentrations (median and range) of gentamicin measured 1 h post-nebulisation were 790 (352–>1250) mg/l and then, before the next dose, were 436 (250–1000) mg/l.

Conclusion: Nebulised gentamicin attained high concentrations in the ET lumen and was more effective in preventing the formation of biofilm than either parenterally administered cephalosporin and therefore may be effective in preventing this complication of mechanical ventilation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Thermoresponsive polymeric platforms are used to optimise drug delivery in pharmaceutical systems and bioactive medical devices. However, the practical application of these systems is compromised by their poor mechanical properties. This study describes the design of thermoresponsive semi-interpenetrating polymer networks (s-IPNs) based on cross-linked p(NIPAA) or p(NIPAA-co-HEMA) hydrogels containing poly(e-caprolactone) designed to address this issue. Using DSC, the lower critical solution temperature of the co-polymer and p(NIPAA) matrices were circa 34 °C and 32 °C, respectively. PCL was physically dispersed within the hydrogel matrices as confirmed using confocal scanning laser microscopy and DSC and resulted in marked changes in the mechanical properties (ultimate tensile strength, Young's modulus) without adversely compromising the elongation properties. P(NIPAA) networks containing dispersed PCL exhibited thermoresponsive swelling properties following immersion in buffer (pH 7), with the equilibrium-swelling ratio being greater at 20 °C than 37 °C and greatest for p(NIPAA)/PCL systems at 20 °C. The incorporation of PCL significantly lowered the equilibrium swelling ratio of the various networks but this was not deemed practically significant for s-IPNs based on p(NIPAA). Thermoresponsive release of metronidazole was observed from s-IPN composed of p(NIPAA)/PCL at 37 °C but not from p(NIPAA-co-HEMA)/PCL at this temperature. In all other platforms, drug release at 20 °C was significantly similar to that at 37 °C and was diffusion controlled. This study has uniquely described a strategy by which thermoresponsive drug release may be performed from polymeric platforms with highly elastic properties. It is proposed that these materials may be used clinically as bioactive endotracheal tubes, designed to offer enhanced resistance to ventilator associated pneumonia, a clinical condition associated with the use of endotracheal tubes where stimulus responsive drug release from biomaterials of significant mechanical properties would be advantageous. © 2012 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Study Objectives: To study endotracheal tube (ETT) cuff pressures during nitrous oxide (N2O) anesthesia when the cuffs are inflated with air to achieve sealing pressure, and to evaluate the frequency of postoperative laryngotracheal complaints.Design: Prospective, randomized, blind study.Setting: Metropolitan teaching hospital.Patients: 50 ASA physical status I and II patients scheduled for elective abdominal surgery.Interventions: Patients received standard general anesthesia with 66% N2O in oxygen. In 25 patients, the ETT cuff was inflated with air to achieve a sealing pressure (P-seal group). In 25 patients, the ETT cuff was inflated with air to achieve a pressure of 25 cm H2O (P-25 group).Measurements and Main Results: ETT intracuff pressures were recorded before (control) and at 30, 60, 90, 120, and 150 minutes during N2O administration. We investigated the frequency and intensity of sore throat, hoarseness, and dysphagia in patients in the Post-Anesthesia Care Unit (PACU) and 24 hours following tracheal extubation. The cuff pressures in the P-seal group were significantly lower than in the P-25 group at all time points studied (p < 0.001), with a significant increase with time in both groups (p < 0.001). The cuff pressures exceeded the critical pressure of 30 cm H2O only after 90 minutes in the P-seal group and already by 30 minutes in the P-25 group. The frequency and intensity of sore throat, hoarseness, and dysphagia were similar in both groups in the PACU and 24 hours after tracheal extubation (p > 0.05).Conclusions: Minimum ETT sealing cuff pressure during N2O anesthesia did not prevent, but instead attenuated, the increase in cuff pressure and did not decrease postoperative laryngotracheal complaints. (C) 2004 by Elsevier B.V.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

CONTEXTO E OBJETIVO: Os tubos traqueais são dispositivos utilizados para manutenção da ventilação. A hiperinsuflação do balonete do tubo traqueal, causada pela difusão do óxido nitroso (N2O), pode determinar lesões traqueais, que se manifestam clinicamente como odinofagia, rouquidão e tosse. A lidocaína, quando injetada no balonete do tubo traqueal, difunde-se através de sua parede, determinando ação anestésica local na traquéia. O objetivo foi avaliar a efetividade e a segurança do balonete do tubo traqueal preenchido com ar comparado com o balonete preenchido com lidocaína, considerando os desfechos: sintomas cardiovasculatórios (HAS, taquicardia); odinofagia, tosse, rouquidão e tolerância ao tubo traqueal. TIPO DE ESTUDO E LOCAL: Estudo clínico prospectivo, realizado no Departamento de Anestesiologia da Faculdade de Medicina da Unesp, campus de Botucatu. MÉTODOS: A pressão do balonete do tubo traqueal foi medida, entre 50 pacientes, antes, 30, 60, 90 e 120 minutos após o início da inalação de N2O anestésico. As pacientes foram distribuídas aleatoriamente em dois grupos: Air, em que o balonete foi inflado com ar para obtenção de pressão de 20 cm H2O, e Lido, em que o balonete foi preenchido com lidocaína a 2% mais bicarbonato de sódio a 8,4% para obtenção da mesma pressão. O desconforto antes da extubação, e manifestações clínicas como dor de garganta, rouquidão e tosse foram registrados no momento da alta da unidade de cuidados pós-anestésicos, e dor de garganta e rouquidão foram avaliadas também 24 horas após a anestesia. RESULTADOS: Os valores da pressão no balonete em G2 foram significativamente menores do que os de Air em todos os tempos de estudo, a partir de 30 minutos (p < 0,001). A proporção de pacientes que reagiu ao tubo traqueal no momento da desintubação foi significantemente menor em Lido (p < 0,005). A incidência de odinofagia foi significantemente menor em Lido no primeiro dia de pós-operatório (p < 0,05). A incidência de tosse e rouquidão não diferiu entre os grupos. CONCLUSÕES: Durante ventilação artificial, empregando-se a mistura de oxigênio e N2O, a insuflação do balonete com lidocaína 2% alcalinizada impede que ocorra aumento significante da pressão no balonete e determina maior tolerância ao tubo traqueal e menor incidência de odinofagia no pós-operatório, podendo então ser considerada mais segura e com maior efetividade.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJETIVO: Avaliar as alterações morfológicas no epitélio traqueal de cães expostos à inalação de gases pouco condicionados, sob ventilação com tubo traqueal (TT) ou máscara laríngea (ML). MÉTODOS: Doze cães adultos foram divididos aleatoriamente em dois grupos: grupo TT (n-6) e grupo ML (n-6), submetidos à anestesia venosa e ventilação mecânica, em sistema sem reabsorção de CO2. Foram registrados parâmetros hemodinâmicos e ventilatórios, temperatura timpânica, temperatura, umidade relativa e absoluta do ar ambiente e dos gases inalados durante 3 horas. Ao término do experimento, os animais foram submetidos a eutanásia e realizadas biópsias ao longo do segmento traqueal para estudo morfológico. Três cães saudáveis foram utilizados para controle morfológico. RESULTADOS: A temperatura dos gases inalados manteve-se entre 24ºC e 26ºC, a umidade relativa entre 10% e 12%, e umidade absoluta entre 2 -3 mg H2O.L-1 sem diferença significativa entre os grupos. em ambos os grupos a análise histológica evidenciou processo inflamatório epitelial e congestão no córion, e a microscopia eletrônica de varredura mostrou agrupamento e desorganização ciliar. A microscopia eletrônica de transmissão detectou maiores alterações no grupo TT do que no ML, como alargamento das junções intercelulares, desorientação ciliar, vacuolização citoplasmática, alterações nucleares como pcinose e condensação da cromatina. CONCLUSÃO: A máscara laríngea determinou alterações menos pronunciadas no epitélio traqueal de cães expostos à inalação de gases pouco condicionados.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To determine, in dogs anesthetized with nitrous oxide (N2O), whether the endotracheal tube (ETT) cuffed with a Lanz® pressure regulating valve decreases the tracheal consequences of tracheal intubation. Methods: Sixteen mixed-breed dogs were allocated to two groups according to the ETT used: Control group (n = 8) - Rüsch ETT, and Lanz group (n = 8) - ETT with Lanz® pressure regulating valve. The ETT cuffs in both groups were inflated with air to an intracuff pressure of 30 cm H2O. Anesthesia was induced and maintained with pentobarbitone and N2O (1.5 L·min-1) and O2 (1 L·min-1). ETT cuff pressures were measured before (control) and 60, 120, and 180 min during N2O administration. The dogs were sacrificed, and biopsy specimens from four predetermined areas of the tracheal mucosa in contact with the ETT were collected for light and scanning electron microscopy (SM) examination. Results: Cuff pressures in the Control group were higher than in the Lanz group at all time points studied (P < 0.001), with an increase over time only in the Control group (P < 0.001). Median neutrophilic inflammatory infiltration values of the epithelial surface, and in the subepithelial layer in contact with the cuff, were higher in the Control group as compared to the Lanz group (3.0 vs 1.0 and 3.0 vs 1.5 respectively) (P < 0.05). On SM examination, median histological grades were higher in the Control group compared to Lanz group (2.9 vs 1.9 respectively), (P < 0.05). Conclusions: The Lanz® ETT decreases tracheal mucosal injury in dogs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pen & Ink; Dr. Norman Thompson, University of Michigan Department of Surgery

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background. Previous studies have identified no strong correlation between patients' height and tracheal length in anaesthetized patients. We have attempted to compare vocal cords-carina distance (VCD) in Chinese patients with the dimensions of five commonly used tracheal tubes. In addition, we attempted to find a surface anatomy measurement that would identify patients with 'short tracheas'. Methods. We measured VCD in 130 anaesthetized Chinese patients with a fibreoptic bronchoscope. Also measurements were obtained of the distal ends of five commonly used tracheal tubes. We undertook various surface anatomy measurements on the patients' chest and neck region to predict those patients with short tracheas. Results. VCD averaged 12.6 ((SD) 1.4) cm. In seven patients (5%) this distance was particularly short (between 8.8 and 10.4 cm). Many of the commonly used tracheal tubes would be placed close to or beyond the carina when the black intubation guide mark(s) is (are) at the level of the vocal cords. The VCD of