909 resultados para Elementary particles
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
In this work we investigate a possible magnetic moment generation for massive neutral particles with spins-1 and -2 coupled non-minimally, in a specific way, to an external electromagnetic field. It is found that, in the nonrelativistic limit, these particles present g = 1. This result, worked out in the framework of Relativistic Quantum Mechanics, seems to suggest that g = 1 for all massive and neutral particles of any spin ≤ 2. We also compare with the results obtained for massive charged particles of spins-1 and -2, in the same regime (nonrelativistic), in order to investigate the role played by the spin separetely from the charge. Copyright © owned by the author(s) under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike Licence.
Resumo:
"Addendum, July 1962." (10 p.), issued in 1962.
Resumo:
We analyze free elementary particles with a rest mass m and total energy E
Resumo:
Ultrastructural morphology and ATPase specific activities of mitochondria isolated from 1-celled fertilized egg, 10-day embryo, 21-day infective larvae and adult body wall muscle of Ascaris suum and rat liver were determined and compared. Although cristae of both muscle and egg mitochondria contained numerous elementary particles with head pieces of conventional diameter (85 A), each muscle mitochondrion contained relatively few, short cristae with a diminished frequency of elementary particles and associated ATPase activity. These morphological relationships are related to the previous conclusion that the transition from an aerobic to an essentially anaerobic metabolism is intimately associated with the mitochondrion and is a normal and mandatory feature of development.
Resumo:
Position sensitive particle detectors are needed in high energy physics research. This thesis describes the development of fabrication processes and characterization techniques of silicon microstrip detectors used in the work for searching elementary particles in the European center for nuclear research, CERN. The detectors give an electrical signal along the particles trajectory after a collision in the particle accelerator. The trajectories give information about the nature of the particle in the struggle to reveal the structure of the matter and the universe. Detectors made of semiconductors have a better position resolution than conventional wire chamber detectors. Silicon semiconductor is overwhelmingly used as a detector material because of its cheapness and standard usage in integrated circuit industry. After a short spread sheet analysis of the basic building block of radiation detectors, the pn junction, the operation of a silicon radiation detector is discussed in general. The microstrip detector is then introduced and the detailed structure of a double-sided ac-coupled strip detector revealed. The fabrication aspects of strip detectors are discussedstarting from the process development and general principles ending up to the description of the double-sided ac-coupled strip detector process. Recombination and generation lifetime measurements in radiation detectors are discussed shortly. The results of electrical tests, ie. measuring the leakage currents and bias resistors, are displayed. The beam test setups and the results, the signal to noise ratio and the position accuracy, are then described. It was found out in earlier research that a heavy irradiation changes the properties of radiation detectors dramatically. A scanning electron microscope method was developed to measure the electric potential and field inside irradiated detectorsto see how a high radiation fluence changes them. The method and the most important results are discussed shortly.
Resumo:
This thesis describes the development of advanced silicon radiation detectors and their characterization by simulations, used in the work for searching elementary particles in the European Organization for Nuclear Research, CERN. Silicon particle detectors will face extremely harsh radiation in the proposed upgrade of the Large Hadron Collider, the future high-energy physics experiment Super-LHC. The increase in the maximal fluence and the beam luminosity up to 1016 neq / cm2 and 1035 cm-2s-1 will require detectors with a dramatic improvement in radiation hardness, when such a fluence will be far beyond the operational limits of the present silicon detectors. The main goals of detector development concentrate on minimizing the radiation degradation. This study contributes mainly to the device engineering technology for developing more radiation hard particle detectors with better characteristics. Also the defect engineering technology is discussed. In the nearest region of the beam in Super-LHC, the only detector choice is 3D detectors, or alternatively replacing other types of detectors every two years. The interest in the 3D silicon detectors is continuously growing because of their many advantages as compared to conventional planar detectors: the devices can be fully depleted at low bias voltages, the speed of the charge collection is high, and the collection distances are about one order of magnitude less than those of planar technology strip and pixel detectors with electrodes limited to the detector surface. Also the 3D detectors exhibit high radiation tolerance, and thus the ability of the silicon detectors to operate after irradiation is increased. Two parameters, full depletion voltage and electric field distribution, is discussed in more detail in this study. The full depletion of the detector is important because the only depleted area in the detector is active for the particle tracking. Similarly, the high electric field in the detector makes the detector volume sensitive, while low-field areas are non-sensitive to particles. This study shows the simulation results of full depletion voltage and the electric field distribution for the various types of 3D detectors. First, the 3D detector with the n-type substrate and partial-penetrating p-type electrodes are researched. A detector of this type has a low electric field on the pixel side and it suffers from type inversion. Next, the substrate is changed to p-type and the detectors having electrodes with one doping type and the dual doping type are examined. The electric field profile in a dual-column 3D Si detector is more uniform than that in the single-type column 3D detector. The dual-column detectors are the best in radiation hardness because of their low depletion voltages and short drift distances.
Resumo:
The fascinating search of the inner boundaries of the Universe, has been entangled, since the birth of greek philosophy 25 centuries ago, with the main epistemological changes in the History of Science. This paper does not intend to present a systematic description of the discovery of the elementary particles. By stressing the main achievements of the knowledge of matter's structure and their dependence on symmetry arguments, it is argued that even considering profound differences in each historical period, there is a paradgima of atom shared by Chemistry and Particle Physics. This text could help High School Teachers of Chemistry and Physics, as well as motivate them, in the challenge of explaining to their pupils how the idea of atom evolved.
Resumo:
Large Hadron Collider (LHC) is the main particle accelerator at CERN. LHC is created with main goal to search elementary particles and help science investigate our universe. Radiation in LHC is caused by charged particles circular acceleration, therefore detectors tracing particles in existed severe conditions during the experiments must be radiation tolerant. Moreover, further upgrade of luminosity (up to 1035 cm-2s-1) requires development of particle detector’s structure. This work is dedicated to show the new type 3D stripixel detector with serious structural improvement. The new type of radiation-hard detector has a three-dimensional (3D) array of the p+ and n+ electrodes that penetrate into the detector bulk. The electrons and holes are then collected at oppositely biased electrodes. Proposed 3D stripixel detector demonstrates that full depletion voltage is lower that that for planar detectors. Low depletion voltage is one of the main advantages because only depleted part of the device is active are. Because of small spacing between electrodes, charge collection distances are smaller which results in high speed of the detector’s response. In this work is also briefly discussed dual-column type detectors, meaning consisting both n+ and p+ type columnar electrodes in its structure, and was declared that dual-column detectors show better electric filed distribution then single sided radiation detectors. The dead space or in other words low electric field region in significantly suppressed. Simulations were carried out by using Atlas device simulation software. As a simulation results in this work are represented the electric field distribution under different bias voltages.
Resumo:
Les détecteurs ATLAS-MPX sont des détecteurs Medipix2-USB recouverts de convertisseurs de fluorure de lithium et de polyéthylène pour augmenter l’efficacité de détection des neutrons lents et des neutrons rapides respectivement. Un réseau de quinze détecteurs ATLAS-MPX a été mis en opération dans le détecteur ATLAS au LHC du CERN. Deux détecteurs ATLAS-MPX de référence ont été exposés à des sources de neutrons rapides 252 Cf et 241 AmBe ainsi qu’aux neutrons rapides produits par la réaction 7Li(p, xn) pour l’étude de la réponse du détecteur à ces neutrons. Les neutrons rapides sont principalement détectés à partir des protons de recul des collisions élastiques entre les neutrons et l’hydrogène dans le polyéthylène. Des réactions nucléaires entre les neutrons et le silicium produisent des particules-α. Une étude de l’efficacité de reconnaissance des traces des protons et des particules-α dans le détecteur Medipix2-USB a été faite en fonction de l’énergie cinétique incidente et de l’angle d’incidence. L’efficacité de détection des neutrons rapides a été évaluée à deux seuils d’énergie (8 keV et 230 keV) dans les détecteurs ATLAS-MPX. L’efficacité de détection des neutrons rapides dans la région du détecteur couverte avec le polyéthylène augmente en fonction de l’énergie des neutrons : (0.0346 ± 0.0004) %, (0.0862 ± 0.0018) % et (0.1044 ± 0.0026) % pour des neutrons rapides de 2.13 MeV, 4.08 MeV et 27 MeV respectivement. L’étude pour déterminer l’énergie des neutrons permet donc d’estimer le flux des neutrons quand le détecteur ATLAS-MPX est dans un champ de radiation inconnu comme c’est le cas dans le détecteur ATLAS au LHC.
Resumo:
La matière sombre est un mystère dans le domaine de l’astrophysique depuis déjà plusieurs années. De nombreuses observations montrent que jusqu’à 85 % de la masse gravitationnelle totale de l’univers serait composée de cette matière de nature inconnue. Une théorie expliquant cette masse manquante considérerait les WIMPs (Weakly Interacting Massive Particles), particules stables, non chargées, prédites par des extensions du modèle standard, comme candidats. Le projet PICASSO (Projet d’Identification des CAndidats Supersymétriques à la matière Sombre) est une expérience qui tente de détecter directement le WIMP. Le projet utilise des détecteurs à gouttelettes de fréon (C4F10) surchauffées. La collision entre un WIMP et le noyau de fluor crée un recul nucléaire qui cause à son tour une transition de phase de la gouttelette liquide à une bulle gazeuse. Le bruit de ce phénomène est alors capté par des senseurs piézoélectriques montés sur les parois des détecteurs. Le WIMP n’est cependant pas la seule particule pouvant causer une telle transition de phase. D’autres particules environnantes peuvent former des bulles, telles les particules alpha où même des rayons gamma . Le système d’acquisition de données (DAQ) est aussi en proie à du bruit électronique qui peut être enregistré, ainsi que sensible à du bruit acoustique extérieur au détecteur. Finalement, des fractures dans le polymère qui tient les gouttelettes en place peut également causer des transitions de phase spontanées. Il faut donc minimiser l’impact de tous ces différents bruit de fond. La pureté du matériel utilisé dans la fabrication des détecteurs devient alors très importante. On fait aussi appel à des méthodes qui impliquent l’utilisation de variables de discrimination développées dans le but d’améliorer les limites d’exclusion de détection du WIMP.
Resumo:
Nous rapportons les résultats d'une étude des désintégrations semileptoniques non-charmées B^+--> êta^(') l^+v et B^0--> pi^- l^+v, mesurés par le détecteur BABAR avec une production d'environ 464 millions de paires de mésons BBbar issues des collisions e^+e^- à la résonance Upsilon(4S). L'analyse reconstruit les événements avec une technique relâchée des neutrinos. Nous obtenons les rapports d'embranchement partiels pour les désintégrations B^+--> êta l^+v et B^0--> pi^- l^+v en trois et douze intervalles de q^2, respectivement, à partir desquels nous extrayons les facteurs de forme f_+(q^2) et les rapports d'embranchement totaux B(B^+--> êta l^+v) = (3.39 +/- 0.46_stat +/- 0.47_syst) x 10^-5 et B(B^0--> pi^- l^+v) = (1.42 +/- 0.05_stat +/- 0.08_syst) x 10^-4. Nous mesurons aussi B(B^+--> êta' l^+v) = (2.43 +/- 0.80_stat +/- 0.34_syst) x 10^-5. Nous obtenons les valeurs de la norme de l'élément |V_ub| de la matrice CKM en utilisant trois calculs différents de la CDQ.
Resumo:
Les seize détecteurs MPX constituant le réseau ATLAS-MPX ont été placés à différentes positions dans le détecteur ATLAS et sa averne au CERN dans le but de mesurer en emps réel les champs de radiation produits ar des particules primaires (protons des faisceaux) et des particules secondaires (kaons, pions, g, protons) issues des collisions proton-proton. Des films de polyéthylène (PE) et de fluorure de lithium (6LiF) recouvrent les détecteurs afin d’augmenter leur sensibilité aux neutrons produits par les particules primaires et secondaires interagissant avec les matériaux présents dans l’environnement d’ATLAS. La reconnaissance des traces laissées par les particules dans un détecteur ATLAS-MPX se fait à partir des algorithmes du logiciel MAFalda (“Medipix Analysis Framework”) basé sur les librairies et le logiciel d’analyse de données ROOT. Une étude sur le taux d’identifications erronées et le chevauchement d’amas a été faite en reconstruisant les activités des sources 106Ru et 137Cs. L’efficacité de détection des neutrons rapides a été mesurée à l’aide des sources 252Cf et 241AmBe (neutrons d’énergie moyenne de 2.13 et 4.08 MeV respectivement). La moyenne des efficacités de détection mesurées pour les neutrons produits par les sources 252C f et 241AmBe a été calculée pour les convertisseurs 6LiF et PE et donnent (0.8580 ± 0.1490)% et (0.0254 ± 0.0031)% pour LiF et (0.0510 ± 0.0061)% et (0.0591 ± 0.0063)% pour PE à bas et à haut seuil d’énergie respectivement. Une simulation du calcul de l’efficacité de détection des neutrons dans le détecteur MPX a été réalisée avec le logiciel GEANT4. Des données MPX correspondant aux collisions proton-proton à 2.4 TeV et à 7 TeV dans le centre de masse ont été analysées. Les flux détectés d’électrons et de photons sont particulièrement élevés dans les détecteurs MPX01 et MPX14 car ils sont plus près du point de collision. Des flux de neutrons ont été estimés en utilisant les efficacités de détection mesurées. Une corrélation avec la luminosité du LHC a été établie et on prédit que pour les collisions à 14 TeV dans le centre de masse et avec une luminosité de 10^34 cm-1*s-1 il y aura environ 5.1x10^8 ± 1.5x10^7 et 1.6x10^9 ± 6.3x10^7 particules détectées par les détecteurs MPX01 et MPX14 respectivement.
Détection des événements de "Minimum Bias" et neutrons avec les détecteurs ATLAS-MPX par simulations
Resumo:
Un réseau de seize détecteurs ATLAS-MPX a été mis en opération dans le détecteur ATLAS au LHC du CERN. Les détecteurs ATLAS-MPX sont sensibles au champ mixte de radiation de photons et d’électrons dans la caverne d’ATLAS et sont recouverts de convertisseurs de fluorure de lithium et de polyéthylène pour augmenter l’efficacité de détection des neutrons thermiques et des neutrons rapides respectivement. Les collisions à haute énergie sont dominées par des interactions partoniques avec petit moment transverse pT , associés à des événements de “minimum bias”. Dans notre cas la collision proton-proton se produit avec une énergie de 7 TeV dans le centre de masse avec une luminosité de 10³⁴cm⁻²s⁻¹ telle que fixée dans les simulations. On utilise la simulation des événements de "minimum bias" générés par PYTHIA en utilisant le cadre Athena qui fait une simulation GEANT4 complète du détecteur ATLAS pour mesurer le nombre de photons, d’électrons, des muons qui peuvent atteindre les détecteurs ATLASMPX dont les positions de chaque détecteur sont incluses dans les algorithmes d’Athena. Nous mesurons les flux de neutrons thermiques et rapides, générés par GCALOR, dans les régions de fluorure de lithium et de polyéthylène respectivement. Les résultats des événements de “minimum bias” et les flux de neutrons thermiques et rapides obtenus des simulations sont comparés aux mesures réelles des détecteurs ATLAS-MPX.