997 resultados para Electron detector


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Langstaff, David; Bushell, A.; Chase, T.; Evans, D.A., (2005) 'A fully integrated multi-channel detector for electron spectroscopy', Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms 238 pp.219-223 RAE2008 Synchrotron Radiation in Materials Science ? Proceedings of the 4th Conference on Synchrotron Radiation in Materials Science 4th Conference on Synchrotron Radiation in Materials Science

Relevância:

70.00% 70.00%

Publicador:

Resumo:

We report a new method for quantitative estimation of graphene layer thicknesses using high contrast imaging of graphene films on insulating substrates with a scanning electron microscope. By detecting the attenuation of secondary electrons emitted from the substrate with an in-column low-energy electron detector, we have achieved very high thickness-dependent contrast that allows quantitative estimation of thickness up to several graphene layers. The nanometer scale spatial resolution of the electron micrographs also allows a simple structural characterization scheme for graphene, which has been applied to identify faults, wrinkles, voids, and patches of multilayer growth in large-area chemical vapor deposited graphene. We have discussed the factors, such as differential surface charging and electron beam induced current, that affect the contrast of graphene images in detail. (C) 2011 American Institute of Physics. doi:10.1063/1.3608062]

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The upgrade of the Mainz Mikrotron (MAMI) electron accelerator facility in 2007 which raised the beam energy up to 1.5,GeV, gives the opportunity to study strangeness production channels through electromagnetic process. The Kaon Spectrometer (KAOS) managed by the A1 Collaboration, enables the efficient detection of the kaons associated with strangeness electroproduction. Used as a single arm spectrometer, it can be combined with the existing high-resolution spectrometers for exclusive measurements in the kinematic domain accessible to them.rnrnFor studying hypernuclear production in the ^A Z(e,e'K^+) _Lambda ^A(Z-1) reaction, the detection of electrons at very forward angles is needed. Therefore, the use of KAOS as a double-arm spectrometer for detection of kaons and the electrons at the same time is mandatory. Thus, the electron arm should be provided with a new detector package, with high counting rate capability and high granularity for a good spatial resolution. To this end, a new state-of-the-art scintillating fiber hodoscope has been developed as an electron detector.rnrnThe hodoscope is made of two planes with a total of 18432 scintillating double-clad fibers of 0.83 mm diameter. Each plane is formed by 72 modules. Each module is formed from a 60deg slanted multi-layer bundle, where 4 fibers of a tilted column are connected to a common read out. The read-out is made with 32 channels of linear array multianode photomultipliers. Signal processing makes use of newly developed double-threshold discriminators. The discriminated signal is sent in parallel to dead-time free time-to-digital modules and to logic modules for triggering purposes.rnrnTwo fiber modules were tested with a carbon beam at GSI, showing a time resolution of 220 ps (FWHM) and a position residual of 270 microm m (FWHM) with a detection efficiency epsilon>99%.rnrnThe characterization of the spectrometer arm has been achieved through simulations calculating the transfer matrix of track parameters from the fiber detector focal plane to the primary vertex. This transfer matrix has been calculated to first order using beam transport optics and has been checked by quasielastic scattering off a carbon target, where the full kinematics is determined by measuring the recoil proton momentum. The reconstruction accuracy for the emission parameters at the quasielastic vertex was found to be on the order of 0.3 % in first test realized.rnrnThe design, construction process, commissioning, testing and characterization of the fiber hodoscope are presented in this work which has been developed at the Institut für Kernphysik of the Johannes Gutenberg - Universität Mainz.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Nesta dissertação, duas resinas reticuladas comerciais (denominadas, AmberliteGT73 e AmberliteIRC748) foram empregadas para suportar partículas de prata. Os grupos tiol da GT73 e ácido iminodiacético da IRC748 presentes nessas resinas foram empregados para a fixação de íons Ag+ a partir de solução aquosa. Posteriormente, os íons Ag+ foram reduzidos pelo emprego de três redutores diferentes em pH alcalino, denominados hidrazina, hidroxilamina e formaldeído (pH  12). A morfologia e a impregnação de prata dos materiais binários assim obtidos foram avaliadas por meio de microscópio eletrônico de varredura equipado com detector de elétrons retro-espalhados (SEM-BSE). O detector de espectrometria de energia dispersiva de raios-X (EDAX) acoplado ao SEM permitiu a observação de partículas de prata. Os espectros de raios-X revelaram a presença do metal nas superfícies interna e externa das microesferas dos compósitos. A quantidade de prata incorporada foi determinada pelo método titulométrico, empregando solução padrão de tiocianato de potássio. As características antibactericidas dos compósitos foram avaliadas em colunas contendo pérolas de resina por onde foram percoladas suspensões da bactéria Escherichia coli auxotrópica AB1157 (tipo selvagem) nas concentrações de 103 a 107 células/mL. A avaliação biocida mostrou que estes materiais foram completamente bactericidas, sendo efetivos na eliminação da bactéria em poucos minutos. Esta ação biocida foi atribuída à combinação da atuação da prata e dos grupos funcionais das resinas

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The main concern of the A4 parity violation experiment at the Mainzer Microtron accelerator facility is to study the electric and magnetic contributions of strange quarks to the charge and magnetism of the nucleons at the low momentum transfer region. More precisely, the A4 collaboration investigates the strange quarks' contribution to the electric and magnetic vector form factors of the nucleons. Thus, it is important that the A4 experiment uses an adequate and precise non-destructive online monitoring tool for the electron beam polarization when measuring single spin asymmetries in elastic scattering of polarized electrons from unpolarized nucleons. As a consequence, the A4 Compton backscattering polarimeter was designed and installed such that we can take the absolute measurement of the electron beam polarization without interruption to the parity violation experiment. The present study shows the development of an electron beam line that is called the chicane for the A4 Compton backscattering polarimeter. The chicane is an electron beam transport line and provides an interaction region where the electron beam and the laser beam overlap. After studying the properties of beam line components carefully, we developed an electron beam control system that makes a beam overlap between the electron beam and the laser beam. Using the system, we can easily achieve the beam overlap in a short time. The electron control system, of which the performance is outstanding, is being used in production beam times. And the study presents the development of a scintillating fiber electron detector that reduces the statistical error in the electron polarization measurement. We totally redesigned the scintillating fiber detector. The data that were taken during a 2008 beam time shows a huge background suppression, approximately 80 percent, while leaving the Compton spectra almost unchanged when a coincidence between the fiber detector and the photon detector is used. Thus, the statistical error of the polarization measurement is reduced by about 40 percent in the preliminary result. They are the significant progress in measuring a degree of polarization of the electron beam.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Das A4-Experiment bestimmt den Beitrag der Strangequarks zu den elektromagnetischen Formfaktoren des Nukleons durch Messung der Paritätsverletzung in der elastischen Elektron-Nukleon-Streuung. Diese Messungen werden mit dem spinpolarisierten Elektronenstrahl des Mainzer Mikrotrons (MAMI) bei Strahlenergien zwischen 315 und 1508 MeV ndurchgeführt. Die Bestimmung des Strahlpolarisationsgrades ist für die Analyse der Daten unerläßlich, um die physikalische Asymmetrie aus der gemessenen paritätsverletzenden Asymmetrie extrahieren zu können. Aus diesem Grund wird von der A4-Kollaboration ein neuartiges Compton-Laserrückstreupolarimeter entwickelt, das eine zerstörungsfreie Messung der Strahlpolarisation, parallel zum laufenden Paritätsexperiment erlaubt. Um den zuverlässigen Dauerbetrieb des Polarimeters zu ermöglichen, wurde das Polarimeter im Rahmen dieser Arbeit weiterentwickelt. Das Datenerfassungssystem für Photonen- und Elektronendetektor wurde neu aufgebaut und im Hinblick auf die Verarbeitung hoher Raten optimiert. Zum Nachweis der rückgestreuten Photonen wurde ein neuartiger Detektor (LYSO) in Betrieb genommen. Darüber hinaus wurden GEANT4-Simulationen der Detektoren durchgeführt und eine Analyseumgebung für die Extraktion von Comptonasymmetrien aus den Rückstreudaten entwickelt. Das Analyseverfahren nutzt die Möglichkeit, die rückgestreuten Photonen durch koinzidente Detektion der gestreuten Elektronen energiemarkiert nachzuweisen (Tagging). Durch die von der Energiemarkierung eingeführte differentielle Energieskala wird somit eine präzise Bestimmung der Analysierstärke möglich. In der vorliegenden Arbeit wurde die Analysierstärke des Polarimeters bestimmt, so daß nun das Produkt von Elektronen- und Laserstrahlpolarisation bei einem Strahlstrom von 20 muA, parallel zum laufenden Paritätsexperiment, mit einer statistischen Genauigkeit von 1% in 24 Stunden bei 855 MeV bzw. <1% in 12 Stunden bei 1508 MeV gemessen werden kann. In Kombination mit der Bestimmung der Laserpolarisation in einer parallelen Arbeit (Y. Imai) auf 1% kann die statistische Unsicherheit der Strahlpolarisation im A4-Experiment von zuvor 5% auf nun 1,5% bei 1508MeV verringert werden. Für die Daten zur Messung der paritätsverletzenden Elektronenstreuung bei einem Viererimpulsübertrag von $Q^2=0,6 (GeV/c)^2$ beträgt die Rohasymmetrie beim derzeitigen Stand der Analyse $A_{PV}^{Roh} = ( -20,0 pm 0,9_{stat} ) cdot 10^{-6}$. Für eine Strahlpolarisation von 80% erhält man einen Gesamtfehler von $1,68 cdot 10^{-6}$ für $Delta P_e/P_e = 5 %$. Als Ergebnis dieser Arbeit wird sich dieser Fehler durch Analyse der Daten des Compton-Laserrückstreupolarimeters um 29% auf $1,19 cdot 10^{-6}$ ($Delta P_e/P_e = 1,5 %$) verringern lassen.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Herein we report the first applications of TCNQ as a rapid and highly sensitive off-the-shelf cyanide detector. As a proof-of-concept, we have applied a kinetically selective single-electron transfer (SET) from cyanide to deep-lying LUMO orbitals of TCNQ to generate a persistently stable radical anion (TCNQ(center dot-)), under ambient condition. In contrast to the known cyanide sensors that operate with limited signal outputs, TCNQ(center dot-) offers a unique multiple signaling platform. The signal readability is facilitated through multichannel absorption in the UV-vis-NIR region and scattering-based spectroscopic methods like Raman spectroscopy and hyper Rayleigh scattering techniques. Particularly notable is the application of the intense 840 nm NIR absorption band to detect cyanide. This can be useful for avoiding background interference in the UV-vis region predominant in biological samples. We also demonstrate the fabrication of a practical electronic device with TCNQ as a detector. The device generates multiorder enhancement in current with cyanide because of the formation of the conductive TCNQ(center dot-).

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A realistic measurement setup for a system such system measured by a mesoscopie detector,is theoretically as a charged two-state (qubit) or multi-state quantum studied. To properly describe the measurement-induced back-action,a detailed-balance preserved quantum master equation treatment is developed. The established framework is applicable for arbitrary voltages and temperatures.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The Isochronous Mass Spectrometry is a high accurate mass spectrometer. A secondary electrons time detector has been developed and used for mass measurements. Secondary electrons from a thin carbon foil are accelerated by ail electric field and deflected 180 degrees by a magnetic field onto a micro-channel plate. The time detector has been tested with alpha particles and a time resolution of 197 ps (FWHM) was obtained in the laboratory. A mass resolution around 8 x 10(-6) For Delta m/m was achieved by using this time detector in a pilot mass measurement experiment.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Langstaff, David; Chase, T., (2007) 'A multichannel detector array with 768 pixels developed for electron spectroscopy', Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 573(1-2) pp.169-171 RAE2008

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The operation of a previously proposed terahertz (THZ) detector is formulated in detail. The detector is based on the hot-electron effect of the 2D electron gas (2DEG) in the quantum well (QW) of a GaAs/AIGaAs heterostructure. The interaction between the THz radiation and the 2DEG, the current enhancement due to hot -electron effect, and the noise performance of the detector are analyzed

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This Letter describes the search for a new heavy charged gauge boson W-' decaying into an electron and a neutrino. The data were collected with the D0 detector at the Fermilab Tevatron p (p) over bar Collider at root s=1.96 TeV, and correspond to an integrated luminosity of about 1 fb(-1). Lacking any significant excess in the data in comparison with known processes, an upper limit is set on sigma(')(W)xB(W-'-> e nu), and a W-' boson with mass below 1.00 TeV can be excluded at the 95% C.L., assuming standard-model-like couplings to fermions. This result significantly improves upon previous limits and is the most stringent to date.