961 resultados para Electromyographic signal acquisition


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of this study was to analyze the electromyographic (EMG) data, before and after normalization. One hundred (100) normal subjects (with no signs and symptoms of temporomandibular disorders) participated in this study. A surface EMG of the masticatory muscles was performed. Two different tests were performed: maximum voluntary clench (MVC) on cotton rolls and MVC in intercuspal position. The normalization was done using the mean value of the EMG signal of the first examination. The coefficient of variation CV showed lower values for the standardized data. The standardization was effective in reducing the differences between records from the same subject and in different subjects.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The ability to monitor fetal heart rate is vital during late pregnancy and labor in order to evaluate fetal well-being. Current monitoring practice is essentially based on external cardiotocography and, less frequently, during labor, invasive fetal scalp electrocardiography. Many current and envisaged applications could benefi t from simpler devices using a 3-lead ECG confi guration. We are designing a maternity support belt with an embedded wireless 3-lead ECG sensor, and have investigated the infl uence of the ground electrode position on signal quality. Data from over 100 pregnant women was collected with the ground electrode placed in 3 locations in order to determine optimum electrode placement and belt form factor.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Applications involving biosignals, such as Electrocardiography (ECG), are becoming more pervasive with the extension towards non-intrusive scenarios helping targeting ambulatory healthcare monitoring, emotion assessment, among many others. In this study we introduce a new type of silver/silver chloride (Ag/AgCl) electrodes based on a paper substrate and produced using an inkjet printing technique. This type of electrodes can increase the potential applications of biosignal acquisition technologies for everyday life use, given that there are several advantages, such as cost reduction and easier recycling, resultant from the approach explored in our work. We performed a comparison study to assess the quality of this new electrode type, in which ECG data was collected with three types of Ag/AgCl electrodes: i) gelled; ii) dry iii) paper-based inkjet printed. We also compared the performance of each electrode when acquired using a professional-grade gold standard device, and a low cost platform. Experimental results showed that data acquired using our proposed inkjet printed electrode is highly correlated with data obtained through conventional electrodes. Moreover, the electrodes are robust to high-end and low-end data acquisition devices. Copyright © 2014 SCITEPRESS - Science and Technology Publications. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Amyotrophic Lateral Sclerosis (ALS) is a neurodegenerative disease characterized by motor neurons degeneration, which reduces muscular force, being very difficult to diagnose. Mathematical methods are used in order to analyze the surface electromiographic signal’s dynamic behavior (Fractal Dimension (FD) and Multiscale Entropy (MSE)), evaluate different muscle group’s synchronization (Coherence and Phase Locking Factor (PLF)) and to evaluate the signal’s complexity (Lempel-Ziv (LZ) techniques and Detrended Fluctuation Analysis (DFA)). Surface electromiographic signal acquisitions were performed in upper limb muscles, being the analysis executed for instants of contraction for ipsilateral acquisitions for patients and control groups. Results from LZ, DFA and MSE analysis present capability to distinguish between the patient group and the control group, whereas coherence, PLF and FD algorithms present results very similar for both groups. LZ, DFA and MSE algorithms appear then to be a good measure of corticospinal pathways integrity. A classification algorithm was applied to the results in combination with extracted features from the surface electromiographic signal, with an accuracy percentage higher than 70% for 118 combinations for at least one classifier. The classification results demonstrate capability to distinguish members between patients and control groups. These results can demonstrate a major importance in the disease diagnose, once surface electromyography (sEMG) may be used as an auxiliary diagnose method.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The detection of physiological signals from the motor system (electromyographic signals) is being utilized in the practice clinic to guide the therapist in a more precise and accurate diagnosis of motor disorders. In this context, the process of decomposition of EMG (electromyographic) signals that includes the identification and classification of MUAP (Motor Unit Action Potential) of a EMG signal, is very important to help the therapist in the evaluation of motor disorders. The EMG decomposition is a complex task due to EMG features depend on the electrode type (needle or surface), its placement related to the muscle, the contraction level and the health of the Neuromuscular System. To date, the majority of researches on EMG decomposition utilize EMG signals acquired by needle electrodes, due to their advantages in processing this type of signal. However, relatively few researches have been conducted using surface EMG signals. Thus, this article aims to contribute to the clinical practice by presenting a technique that permit the decomposition of surface EMG signal via the use of Hidden Markov Models. This process is supported by the use of differential evolution and spectral clustering techniques. The developed system presented coherent results in: (1) identification of the number of Motor Units actives in the EMG signal; (2) presentation of the morphological patterns of MUAPs in the EMG signal; (3) identification of the firing sequence of the Motor Units. The model proposed in this work is an advance in the research area of decomposition of surface EMG signals.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The alternate current biosusceptometry (ACB) is a biomagnetic technique used to study some physiological parameters associated with gastrointestinal (GI) tract. For this purpose it applies an AC magnetic field and measures the response originating from magnetic marks or tracers. This paper presents an equipment based on the ACB which uses anisotropic magnetoresistive (AMR) sensors and an inexpensive electronic support. The ACB-AMR developed consists of a square array of 6x6 sensors arranged in a firstorder gradiometer configuration with one reference sensor. The equipment was applied to capture magnetic images of different phantoms and to acquire gastric contraction activity of healthy rats. The results show a reasonable sensitivity and spatial-temporal resolution, so that it may be applied for imaging of phantoms and signal acquisition of the GI tract of small animals. © 2010 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The work of the present thesis is focused on the implementation of microelectronic voltage sensing devices, with the purpose of transmitting and extracting analog information between devices of different nature at short distances or upon contact. Initally, chip-to-chip communication has been studied, and circuitry for 3D capacitive coupling has been implemented. Such circuits allow the communication between dies fabricated in different technologies. Due to their novelty, they are not standardized and currently not supported by standard CAD tools. In order to overcome such burden, a novel approach for the characterization of such communicating links has been proposed. This results in shorter design times and increased accuracy. Communication between an integrated circuit (IC) and a probe card has been extensively studied as well. Today wafer probing is a costly test procedure with many drawbacks, which could be overcome by a different communication approach such as capacitive coupling. For this reason wireless wafer probing has been investigated as an alternative approach to standard on-contact wafer probing. Interfaces between integrated circuits and biological systems have also been investigated. Active electrodes for simultaneous electroencephalography (EEG) and electrical impedance tomography (EIT) have been implemented for the first time in a 0.35 um process. Number of wires has been minimized by sharing the analog outputs and supply on a single wire, thus implementing electrodes that require only 4 wires for their operation. Minimization of wires reduces the cable weight and thus limits the patient's discomfort. The physical channel for communication between an IC and a biological medium is represented by the electrode itself. As this is a very crucial point for biopotential acquisitions, large efforts have been carried in order to investigate the different electrode technologies and geometries and an electromagnetic model is presented in order to characterize the properties of the electrode to skin interface.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Whole Body Vibrations consist of a vibration stimulus mechanically transferred to the body. The impact of vibration treatment on specific muscular activity, neuromuscular, and postural control has been widely studied. We investigated whole body vibration (WBV) effect on oxygen uptake and electromyographic signal of the rectus femoris muscle during static and dynamic squat. Fourteen healthy subjects performed a static and dynamic squat with and without vibration. During the vibration exercises, a significant increase was found in oxygen uptake (P=0.05), which increased by 44% during the static squat and 29.4% during the dynamic squat. Vibration increased heart rate by 11.1 ± 9.1 beats.min-1 during the static squat and 7.9 ± 8.3 beats.min-1 during the dynamic squat. No significant changes were observed in rate of perceived exertion between the exercises with and without vibration. The results indicate that the static squat with WBV produced higher neuromuscular and cardiorespiratory system activation for exercise duration ?60 sec. Otherwise, if the single bout duration was higher than 60 sec, the greater cardiorespiratory system activation was achieved during the dynamic squat with WBV while higher neuromuscular activation was still obtained with the static exercise.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper is based on the novel use of a very high fidelity decimation filter chain for Electrocardiogram (ECG) signal acquisition and data conversion. The multiplier-free and multi-stage structure of the proposed filters lower the power dissipation while minimizing the circuit area which are crucial design constraints to the wireless noninvasive wearable health monitoring products due to the scarce operational resources in their electronic implementation. The decimation ratio of the presented filter is 128, working in tandem with a 1-bit 3rd order Sigma Delta (ΣΔ) modulator which achieves 0.04 dB passband ripples and -74 dB stopband attenuation. The work reported here investigates the non-linear phase effects of the proposed decimation filters on the ECG signal by carrying out a comparative study after phase correction. It concludes that the enhanced phase linearity is not crucial for ECG acquisition and data conversion applications since the signal distortion of the acquired signal, due to phase non-linearity, is insignificant for both original and phase compensated filters. To the best of the authors’ knowledge, being free of signal distortion is essential as this might lead to misdiagnosis as stated in the state of the art. This article demonstrates that with their minimal power consumption and minimal signal distortion features, the proposed decimation filters can effectively be employed in biosignal data processing units.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A eletromiografia é, hoje em dia, uma das técnicas mais utilizadas no estudo dos músculos, estando presente em áreas como a medicina, a biomecânica e a fisiologia, possibilitando o desenvolvimento científico e contribuindo para proporcionar melhorias na qualidade da vida humana. Sendo assim, este trabalho apresenta um protótipo de um aparelho de aquisição de sinais eletromiográficos, explicando também toda a teoria, técnicas, componentes utilizadas e softwares que estiveram presentes na sua implementação. De uma forma sucinta, para a aquisição do sinal eletromiográfico usou-se uma placa de aquisição NI-USB 6009 e para a visualização do mesmo recorreu-se ao software LabVIEW. Para validar o sinal adquirido com o equipamento desenvolvido, utilizou-se um outro equipamento, o Biopac MP36 Student Lab System, fazendo-se assim recolhas de sinais eletromiográficos com ambos os equipamentos. Os sinais recolhidos pelos dois equipamentos foram analisados no software Acknowledge 3.9.0 (Biopac Systems, Inc.), podendo observar-se os espetros de frequência correspondentes a cada sinal e retirar valores para posterior análise estatística. Feita essa análise, concluiu-se que não foram detetadas diferenças significativas entre os sinais eletromiográficos recolhidos com ambos os equipamentos, validando-se assim, o equipamento desenvolvido.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To identify the electromyographic fatigue threshold in the erector spinae muscle. Methods: Eight 19 to 24-year-old male volunteers participated in this study, in which surface electrodes were used, as well as a biological signals acquisition module (Lynx) with a sampling frequency of 1000Hz, a 1000 times gain, a 20Hz high pass filter and a 500Hz low pass filter. The test consisted of repeated isometric contractions of the erector spinae muscle in a 45° hip flexion posture, with 30%, 40%, 50% and 60% of the maximum voluntary isometric contraction. Results: A positive correlation of the RMS (root mean square) value as a function of time was found for most of the subjects with 40% (N = 6), 50% (N = 7) and 60% (N = 8) loads of the maximum voluntary isometric contraction. Conclusions: It was concluded, from this study, that the proposed protocol provides evidence, through the electromyographic signal, of the development of fatigue in the erector spinae muscle with loads of 40%, 50% and 60% of the maximum voluntary isometric contraction. The protocol also allows the electromyographic fatigue threshold and its probable applicability in the diagnosis of this phenomenon during repetitive activities to be determined.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The effective activity of the pectoralis major and deltoideus anterior muscles in horizontal flyer exercises with external loads of 25, 50, 75 and 100% of the maximum load was studied in 11 male volunteers. The electromyographic analysis was done by using MEDI-TRACE-200 surface electrodes connected to a biological signal acquisition mode coupled to a PC/AT computer. The electromyographic signals were processed and the values obtained were normalized through maximum voluntary isometric contraction. It was statistically observed that in all types and loads of this exercise, the muscles presented significant differences in the concentric and eccentric phases. In the concentric phase, when different loads were compared, the muscles were more active with 75 and 100% of the maximum load, while in the eccentric phase, higher activity was observed with 100% of the maximum load. By analyzing each load effect in the concentric phase, it was verified that the muscles on the left side were more active than those on the right side with 25, 75 and 100% of the maximum load.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of this study was to analyze the electromyographic (EMG) signal behavior of rectus femoris (RF), vastus medialis (VM), vastus lateralis (VL) and biceps femoris (caput longum) (BFCL) from nine women during fatiguing dynamic and isometric knee extensions tests and to determine their EMGFT (Electromyographic Fatigue Threshold). Surface electrodes, biological signal acquisition module, analogical-digital converter board and specific software were used. The RMS (Root Mean Square) values obtained from concentric phase (80 to 30 degrees) of the dynamic knee extension andfrom isometric contraction were correlated with time on each load by linear regression analysis. The respective slopes were correlated with the correspondent load to determine the EMGFT. Force (Kgf) and median frequency - MF (Hz) obtained during MIVC (Maximal Isometric Voluntary Contraction) performed before and after the fatiguing tests were calculated in Matlab environment. The results demonstrated that the endurance time decreases with higher loads the EMG amplitude increase with time and was greater at higher loads, between muscles in dynamic exercise the RF and VL showed higher slopes, and in isometric exercise the VL showed the same behavior The EMGFT values were similar in both exercises; the force values predominantly decreased after fatiguing tests; however the MF only decreased after some loads. The protocols proposed allowed standardizing protocols at least to induce the fatigue process and to determine the EMGFT as an endurance indicative, which may be used to evaluate the effectiveness of rehabilitative or training interventions indicated to reduce muscle weakness and fatigue.