975 resultados para Electromagnetic pulse
Resumo:
In this paper, the susceptibility of a current-mode bandgap voltage reference to electromagnetic interference (EMI) superimposed to the power supply is investigated by simulation. Designed for AMS 0.35 CMOS process, the circuit provides a stable voltage reference in the temperature range of -40-150°C. When EMI disturbances are present, the circuit exhibits only 6.7 mV of offset for interfering signals in the frequency range of 150 kHz-1 GHz. © 2011 ACM.
Resumo:
Flexible magnetic membranes with high proportion of magnetite were successfully prepared by previous impregnation of the never dried bacterial cellulose pellicles with ferric chloride followed by reduction with sodium bisulfite and alkaline treatment for magnetite precipitation. Membranes were characterized by Raman spectroscopy, Fourier transform infrared spectroscopy (FTIR), X-ray diffraction (XRD), vibrating magnetometer, field emission scanning electron microscopy (FEG-SEM) and impedance spectroscopy. Microwave properties of these membranes were investigated in the X-band (8.2 to 12.4 GHz). FEG-SEM micrographs show an effective coverage of the BC nanofibers by Fe 3O4 nanoparticles. Membranes with up to 75% in weight of particles have been prepared after 60 min of reaction. Magnetite nanoparticles in the form of aggregates well adhered to the BC fibers were observed by SEM. The average crystal sizes of the magnetic particles were in the range of 10 ± 1 to 13 ± 1 nm (estimated by XRD). The magnetic particles in the BC pellicles presented superparamagnetic behavior with a saturation magnetization in the range of 60 emu g- 1 and coercive force around 15 Oe. These magnetic pellicles also displayed high electrical permittivity and a potential application as microwave absorber materials. © 2013 Elsevier B.V.
Resumo:
A time dependent electromagnetic pulse generated by a current running laterally to the direction of the pulse propagation is considered in paraxial approximation. It is shown that the pulse envelope moves in the time-spatial coordinates on the surface of a parabolic cylinder for the Airy pulse and a hyperbolic cylinder for the Gaussian. These pulses propagate in time with deceleration along the dominant propagation direction and drift uniformly in the lateral direction. The Airy pulse stops at infinity while the asymptotic velocity of the Gaussian is nonzero. © 2013 Optical Society of America.
Resumo:
On the basis of the global use of the FAM installations and systems, their location, type and height, a lightning protection system is required, which protects humans and machines from danger of a lightning. At the beginning the development, the threat and the potential for destruction of lightning are described. Besides the resulting solid normative calculation models and tables are presented. Then, the product portfolio of the FAM is characterized. From this demonstration models are selected; on the one hand a model for the totality of all portable devices and the other hand a model which defines the power plants. Subsequently, the risk management and a strengths and weaknesses analysis are performed. After that, with graphical and mathematical models, these weaknesses as well as the functional equipotential bonding and grounding system and its dimensioning are investigated and solutions are demonstrated. The following is a coordination of lightning protection standard with other directives and standards in order to classify the resulting internal lightning protection and protective measures against electromagnetic pulse and to generate a uniform protection and application platform. Furthermore, problems of the economy of protective circuit is shown and a solution is given. Finally, the indicated possible solutions are replaced by definitions. The main classification and structure of lightning protection directive are shown and exemplarily applied.
Resumo:
A novel instrument for measurement of X-ray intensity from mammography consists of a sensitive pyro-electric detector, a high-sensitivity, low-noise current-to-voltage converter, a microcontroller and a digital display. The heart of this device, and what makes it unique is the pyro-electric detector, which measures radiation by converting heat from absorbed incident X-rays into an electric current. This current is then converted to a voltage and digitised. The detector consists of a ferro-electric crystal; two types were tested; lithium tantalate and lithium niobate. X-ray measurement in mammography is challenging because of its relatively low photon energy range, from 11 keV to 15 keV equivalent mean energy, corresponding to a peak tube potential from 22 to 36 kV. Consequently, energy fluence rate or intensity is low compared with that of common diagnostic X-ray. The instrument is capable of measuring intensities as low as 0.25 mWm -2 with precision greater than 99%. Not only was the instrument capable of performing in the clinical environment, with high background electromagnetic interference and vibration, but its performance was not degraded after being subjected to 140 roentgen (3.6 × 10 -2 C kg -2 air) as measured by piezo-electric (d 33) or pyro-electric coefficients. © IFMBE 2005.
Resumo:
The aim of this paper is to present a simple method for determining the high frequency parameters of a three-phase induction motor to be used in studies involving variable speed drives with PWM three-phase inverters, in which it is necessary to check the effects caused to the motor by the electromagnetic interference, (EMI) in the differential mode, as well as in the common mode. The motor parameters determination is generally performed in adequate laboratories using accurate instruments, such as very expensive RLC bridges. The method proposed here consists in the identification of the motor equivalent electrical circuit parameters in rated frequency and in high frequency through characteristic tests in the laboratory, together with the use of characteristic equations and curves, shown in the references to be mentioned for determining the motor high frequency parasite capacitances and also through system simulations using dedicated software, like Pspice, determining the characteristic waveforms involved in the differential and common mode phenomena, comparing and validating the procedure through published papers [01].
Resumo:
This paper is based on the analysis and implementation of a new drive system applied to refrigeration systems, complying with the restrictions imposed by the IEC standards (Harmonic/Flicker/EMI-Electromagnetic Interference restrictions), in order to obtain high efficiency, high power factor, reduced harmonic distortion in the input current and reduced electromagnetic interference, with excellent performance in temperature control of a refrigeration prototype system (automatic control, precision and high dynamic response). The proposal is replace the single-phase motor by a three-phase motor, in the conventional refrigeration system. In this way, a proper control technique can be applied, using a closed-loop (feedback control), that will allow an accurate adjustment of the desirable temperature. The proposed refrigeration prototype uses a 0.5Hp three-phase motor and an open (Belt-Drive) Bitzer IY type compressor. The input rectifier stage's features include the reduction in the input current ripple, the reduction in the output voltage ripple, the use of low stress devices, low volume for the EMI input filter, high input power factor (PF), and low total harmonic distortion (THD) in the input current, in compliance with the IEC61000-3-2 standards. The digital controller for the output three-phase inverter stage has been developed using a conventional voltage-frequency control (scalar V/f control), and a simplified stator oriented Vector control, in order to verify the feasibility and performance of the proposed digital controls for continuous temperature control applied at the refrigerator prototype. ©2008 IEEE.
Resumo:
Este trabalho trata sobre a calibração de um aparelho baseado na técnica TDR para estudos do fluxo de água em solo não saturado, com base na medição indireta da umidade, sucção matricial (ψ) e condutividade hidráulica não saturada k(ψ), num perfil de solo inalterado. Isto é possível mediante ensaios de laboratório decorrentes da mecânica de solos tradicional e não saturada, a partir de amostras indeformadas retiradas a diferentes profundidades durante a construção de um poço, onde foram instaladas as sondas do TDR. Dos ensaios, obtiveram-se equações polinomiais para relacionar o comportamento da variação do período de tempo do pulso eletromagnético percorrido pela sonda TDR com a variação da umidade do solo e modelos de van Genuchten (1980) para relacionar a umidade com (ψ) e k(ψ). Os resultados mostraram que, para a calibração da umidade neste tipo de solos, um ajuste polinomial de quarto grau se apresenta como melhor alternativa em relação às expressões existentes em lugares onde foram derivadas estas teorias. Adicionalmente, se observou, que as maiores variações de (ψ) e k(ψ). ocorrerão entre a saturação e 10% de umidade devido à peculiaridade da curva de retenção. Finalmente, a presente calibração se apresenta como um expediente útil e prático para estudos hidrodinâmicos de solos não saturados. Palavras-chave: calibração, reflectômetro, teor de umidade, solo não saturado.
Resumo:
In this paper we present the results of a coherent narrow-band search for continuous gravitational-wave signals from the Crab and Vela pulsars conducted on Virgo VSR4 data. In order to take into account a possible small mismatch between the gravitational-wave frequency and two times the star rotation frequency, inferred from measurement of the electromagnetic pulse rate, a range of 0.02 Hz around two times the star rotational frequency has been searched for both the pulsars. No evidence for a signal has been found and 95% confidence level upper limits have been computed assuming both that polarization parameters are completely unknown and that they are known with some uncertainty, as derived from x-ray observations of the pulsar wind torii. For Vela the upper limits are comparable to the spin-down limit, computed assuming that all the observed spin-down is due to the emission of gravitational waves. For Crab the upper limits are about a factor of 2 below the spin-down limit, and represent a significant improvement with respect to past analysis. This is the first time the spin-down limit is significantly overcome in a narrow-band search.
Resumo:
"August 1970"--Cover.
Resumo:
Ethernet connections, which are widely used in many computer networks, can suffer from electromagnetic interference. Typically, a degradation of the data transmission rate can be perceived as electromagnetic disturbances lead to corruption of data frames on the network media. In this paper a software-based measuring method is presented, which allows a direct assessment of the effects on the link layer. The results can directly be linked to the physical interaction without the influence of software related effects on higher protocol layers. This gives a simple tool for a quantitative analysis of the disturbance of an Ethernet connection based on time domain data. An example is shown, how the data can be used for further investigation of mechanisms and detection of intentional electromagnetic attacks. © 2015 Author(s).
Resumo:
In this contribution, a system identification procedure of a two-input Wiener model suitable for the analysis of the disturbance behavior of integrated nonlinear circuits is presented. The identified block model is comprised of two linear dynamic and one static nonlinear block, which are determined using an parameterized approach. In order to characterize the linear blocks, an correlation analysis using a white noise input in combination with a model reduction scheme is adopted. After having characterized the linear blocks, from the output spectrum under single tone excitation at each input a linear set of equations will be set up, whose solution gives the coefficients of the nonlinear block. By this data based black box approach, the distortion behavior of a nonlinear circuit under the influence of an interfering signal at an arbitrary input port can be determined. Such an interfering signal can be, for example, an electromagnetic interference signal which conductively couples into the port of consideration. © 2011 Author(s).
Resumo:
The explicit expression for spatial-temporal Airy pulse is derived from the Maxwell's equations in paraxial approximation. The trajectory of the pulse in the time-space coordinates is analysed. The existence of a bifurcation point that separates regions with qualitatively different features of the pulse propagation is demonstrated. At this point the velocity of the pulse becomes infinite and the orientation of it changes to the opposite.
Resumo:
A Blumlein line is a particular Pulse Forming Line, PFL, configuration that allows the generation of high-voltage sub-microsecond square pulses, with the same voltage amplitude as the dc charging voltage, into a matching load. By stacking n Blumlein lines one can multiply in theory by n the input dc voltage charging amplitude. In order to understand the operating behavior of this electromagnetic system and to further optimize its operation it is fundamental to theoretically model it, that is to calculate the voltage amplitudes at each circuit point and the time instant that happens. In order to do this, one needs to define the reflection and transmission coefficients where impedance discontinuity occurs. The experimental results of a fast solid-state switch, which discharges a three stage Blumlein stack, will be compared with theoretical ones.
Resumo:
Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do Grau de Mestre em Engenharia Mecânica