968 resultados para Electrochemical quartz crystal microbalance


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The in situ electrochemical quartz crystal microbalance(EQCM) technique was used to investigate the ion transport of immobilized heteropolyanions at a self-assembled monolayer(SAM) modified gold electrode during electrochemical redox process. A mixed transfer method was presented to analyse the abnormal change of resonant frequency based on the simultaneous insertion/extraction of different ions. The results indicate that the migration of HSO4- anions was indispensable in the redox process of the heteropolyan ions in a I mol/L H2SO4 solution and played a key role in the abnormal change of the resonant frequency. Such a change was attributed to different packing densities derived by means of differently immobilized methods.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A novel method is employed for the simultaneous determination of both the calibration constant of an electrochemical quartz crystal microbalance (EQCM) and the active surface area of a polycrystalline gold electrode. A gold electrode: is immersed into a 1 mM KI/1 M H2SO4 solution and on which forms a neutral monolayer. The adsorbed iodine can then be completely oxidized into IO3-. The active surface area of a gold electrode can be obtained from the net electrolytic charge of the oxidation process, and the calibration constant in the EQCM can be calculated from the corresponding frequency shift. The result shows that this method is simple, convenient and valid. (C) 2000 Elsevier Science S.A. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The electrochemical and adsorption behaviors of riboflavin (RF) at gold electrodes has ken studied by using an electrochemical quartz crystal microbalance (EQCM). Useful information is obtained not only about electrochemical behavior but also about mass changes on the electrode surface. The electrochemical properties and frequency shifts were investigated in RF solutions at different pH values, concentrations and scan rates. Reversible voltammograms were observed for pH less than or equal to 9.71. There was no electrochemical reaction for pH > 9.71. The maximum current response was obtained at about pH 8. The current response was proportional to the square root of scan rates when the concentration of RF was lower than 1.0 x 10(-4) mol L-1 (pH 6.92). On the contrary, at concentrations higher than 1.0 x 10(-4) mol L-1 (pH 6.92), it was proportional to the scan rates.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In situ electrochemical scanning tunneling microscopy (ECSTM) and an electrochemical quartz crystal microbalance (EQCM) have been employed to follow the adsorption/desorption processes of phenanthraquinone (PQ sat. in 0.1 mol l(-1) HClO4, solution) accompanied with an electrochemical redox reaction on the Au electrode. The result shows that: (1) the reduced form PQH(2) adsorbed at the Au electrode and the desorption occurred when PQH(2) was oxidized to PQ; (2) the adsorption process initiates at steps or kinks which provide high active sites on the electrode surface for adsorption, and as the potential shifts to negative, a multilayer of PQH(2) may be formed at the Au electrode; (3) the reduced PQH(2) adsorbed preferentially in the area where the tip had been scanned continually; this result suggests that the tip induction may accelerate the adsorption of PQH(2) on the Au(111) electrode. Two kinds of possible reason have been discussed; (4) high resolution STM images show the strong substrate lattice information and the weak monolayer adsorbate lattice information simultaneously. The PQH(2) molecules pack into a not perfectly ordered condensed physisorbed layer at potentials of 0.1 and 0.2 V with an average lattice constant a = 11.5 +/- 0.4 Angstrom, b = 11.5 +/- 0.4 Angstrom, and gamma = 120 +/- 2 degrees; the molecular lattice is rotated with respect to the substrate lattice by about 23 +/- 2 degrees. (C) 1997 Elsevier Science S.A.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An electrochemical quartz crystal microbalance was employed to monitor directly the growth of vanadium hexacyanoferrate (VHF) films on platinum substrates during electrodeposition and interfacial coagulation in the solution containing sulfuric acid electrolyte, vanadium(IV) and hexacyanoferrate(III). Mass changes of the gold/crystal working electrode were correlated with cyclic voltammetry data. Effects of cations (NH4+, Li+, Na+ and K+), anions (SO42- and NO3-) and solvent during redox reactions of the films were studied. The results show that cations were incorporated into the film during reduction and expelled from the film during oxidation. Solvent also participates in VHF electrochemistry, and its role cannot be neglected. Anions play no role in VHF electrochemistry. (C) 1997 Elsevier Science S.A.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The ion exchange mechanism accompanying the oxidation/reduction processes of cupric hexacyanoferrate-modified platinum electrodes in different aqueous electrolyte solutions has been studied by means of in situ probe beam deflection and the electrochemical quartz crystal microbalance technique. The results demonstrate that the charge neutrality of the film during the reoxidation/reduction process is accomplished predominantly by the movement of cations, but anions and/or solvent are also participator(s). Moreover, in KHC8H4O4 (potassium biphthalate) solution, the EQCM data obtained from chronoamperometry experiment are more complicated than those in KCl and K2SO4 solutions. (C) 1997 Elsevier Science Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The electrochemical behavior of flavine adenine dinucleotide (FAD) at a gold electrode involving adsorption of the reduced form FADH(2) and desorption of the oxidized form FAD has been studied by using electrochemical quartz crystal microbalance (EQCM). EQCM can present information not only about the electrochemical behavior but also about the mass changes on the electrode surface. The electrochemical properties and frequency shifts were investigated in FAD solutions at different pH values, concentrations and scan rates. Reversible voltammograms were observed when pH<4.5 and irreversible voltammograms were found when pH greater than or equal to 4.5. It is found to be a diffusion controlled process when the concentration of FAD is lower than 2x10(-4) moll(-1) (pH 1.5). On the contrary, at concentrations higher than 2x10(-4) moll(-1) (pH 1.5), it is found to be an adsorption controlled process.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A highly ordered single crystal carbon material, highly oriented pyrolytic graphite (HOPG) has been successfully employed as a working electrode in an electrochemical quartz crystal microbalance study. RTV silicone rubber is selected to adhere the HOPG film onto the quartz crystal surface. Such modified quartz crystal can oscillate with stable frequency. The electrode modified in this way has good electrochemical properties.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the present work we describe the investigation of interfacial and superficial processes on tetraruthenated zinc porphyrin (ZnTRP) films immobilized on gold electrode surface. In situ and real time measurements employing electrochemical surface plasmon resonance (ESPR)and electrochemical quartz crystal microbalance (EQCM) have given new insights into the electrochemical oxidation of ferrocyanide and phenolic compounds (acetaminophen, dopamine, and catechol) on ZnTRP modified electrodes. The decrease of diode like behavior in the presence of such phenolic species in contrast with ferrocyanide was clearly assigned to the inclusion of those species in the porphyrin film, creating new conduction pathways connecting the gold electrode surface with the film/solution interface. In fact, there are evidences that they can intercalate in the film (catechol > dopamine > acetaminophen), whereas ferrocyanide is completely excluded. Accordingly, the molecular size may play a fundamental role in such a process. (C) 2009 Published by Elsevier Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper we report here new considerations about the relationship between the mass and charge variations (m/z relationship) in underpotential deposition (UPD), bulk deposition and also in the H(2)Se formation reaction. Nanogravimetric experiments were able to show the adsorption of H(2)SeO(3) on the AuO surface prior to the voltammetric sweep and that, after the AuO reduction, 0.40 monolayer of H(2)SeO(3) remains adsorbed on the newly reduced Au surface, which was enough to gives rise to the UPD layer. The UPD results indicate that the maximum coverage with Se(ads) on polycrystalline gold surface corresponds to approximately 0.40 monolayer, in good agreement with charge density results. The cyclic voltammetry experiments demonstrated that the amount of bulk Se obtained during the potential scan to approximately 2 Se monolayers, which was further confirmed by electrochemical quartz crystal microbalance (EQCM) measurements that pointed out a mass variation corresponding of 3 monolayers of Se. In addition, the Se thin films were obtained by chronoamperometric experiments, where the Au electrode was polarized at +0.10V during different times in 1.0 M H(2)SO(4) + 1.0 mM SeO(2). The topologic aspects of the electrodeposits were observed in Atomic Force Microscope (AFM) measurements. Finally, in highly negative potential polarizations, the H(2)Se formation was analyzed by voltammetric and nanogravimetric measurements. These finding brings a new light on the selenium electrodeposition and point up to a proposed electrochemical model for molecule controlled surface engineering. (c) 2009 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Electrochemical quartz crystal microbalance was used to monitor the mass changes during the electrochemical characterization of a zeolite-templated carbon (ZTC) in 1 M H2SO4 medium. Under electrochemical oxidation conditions, a high anodic current and a net mass increase were recorded, resulting in the increase of the specific capacitance owing to the contribution of the pseudocapacitance, mainly derived from the hydroquinone–quinone redox couple. Under more severe electrochemical conditions, a net mass loss was observed, revealing that electrochemical gasification took place. Surface chemistry, before and after the electrochemical treatments, was analyzed through temperature programmed desorption experiments. Furthermore, in situ Raman spectroscopy was used to further characterize the structural changes produced in ZTC under the electrochemical conditions applied, supporting that high potential values produce the electrochemical oxidation and degradation of the carbon material.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

With the cyclic voltammetry and quartz crystal microbalance (QCM), the oxidation process and the electrodeposition behavior were studyied during the electrochemical oxidation of 2-mercaptobenzimidazol in aqueous solution. The E-pH diagram was also gained. These results showed the oxidation reaction was one electron reaction. The results from X-ray photoelectron spectrometry verified that the 2-mercaptobenzimidazol was oxidized to bisbenzimidazoyl disulfide.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A novel electrochemical route is used to form highly {111}-oriented and size-controlled Au nanoprisms directly onto the electrodes of quartz crystal microbalances (QCMs) which are subsequently used as mercury vapor sensors. The Au nanoprism loaded QCM sensors exhibited excellent response–concentration linearity with a response enhancement of up to ~ 800% over a non-modified sensor at an operating temperature of 28 °C. The increased surface area and atomic-scale features (step/defect sites) introduced during the growth of nanoprisms are thought to play a significant role in enhancing the sensing properties of the Au nanoprisms toward Hg vapor. The sensors are shown to have excellent Hg sensing capabilities in the concentration range of 0.123–1.27 ppmv (1.02–10.55 mg m − 3), with a detection limit of 2.4 ppbv (0.02 mg m − 3) toward Hg vapor when operating at 28 °C, and 17 ppbv (0.15 mg m − 3) at 89 °C, making them potentially useful for air monitoring applications or for monitoring the efficiency of Hg emission control systems in industries such as mining and waste incineration. The developed sensors exhibited excellent reversible behavior (sensor recovery) within 1 h periods, and crucially were also observed to have high selectivity toward Hg vapor in the presence of ethanol, ammonia and humidity, and excellent long-term stability over a 33 day operating period.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new kind of inorganic self-assembled monolayer (SAM) was prepared by spontaneous adsorption of polyoxometalate anion, AsMo11VO404-, onto a gold surface from acidic aqueous solution. The adsorption process, structure, and electrochemical properties of the AsMo11VO404- SAM were investigated by quartz crystal microbalance (QCM), electrochemistry, and scanning tunneling microscopy (STM). The QCM data suggested that the self-assembling process could be described in terms of the Langmuir adsorption model, providing the value of the free energy of adsorption at -20 KJ mol(-1). The maximum surface coverage of the AsMo11VO404- SAM on gold surface was determined from the QCM data to be 1.7 x 10(-10) mol cm(-2), corresponding to a close-packed monolayer of AsMo11VO404- anion. The analysis of the voltammograms of the AsMo11VO404- SAM on gold electrode showed three pairs of reversible peaks with an equal surface coverage of 1.78 x 10(-10) mol cm(-2) for each of the peaks, and the value was agreed well with the QCM data. In-situ STM image demonstrated that the AsMo11VO404- SAM was very uniform and no aggregates or multilayer could be observed. Furthermore, the high-resolution STM images revealed that the AsMo11VO404- SAM on Au(lll) surface was composed of square unit cells with a lattice space of 10-11 Angstrom at +0.7 V (vs Ag\AgCl). The value was quite close to the diameter of AsMo11VO404- anion obtained from X-ray crystallographic study. The surface coverage of the AsMo11VO404- SAM on gold electrode estimated from the STM image was around 1.8 x 10(-10) mol cm(-2), which was consistent with the QCM and electrochemical results.