981 resultados para Electro-diesel locomotives
Resumo:
"October 1965."
Resumo:
Mode of access: Internet.
Resumo:
Mode of access: Internet.
Resumo:
"November 1955."
Resumo:
Mode of access: Internet.
Resumo:
The implementation of the railway in Triângulo Mineiro and Alto Paranaíba helped to develop the area and connexion with other states: São Paulo, Goiás and Mato Grosso. The railway used to transport people and goods throughout many train stations in urban and rural areas and some major railroad complexes. There were many factors that led to the decline and abandonment of these properties: governmental policies which were in favour of road transportation and automotive industry, the replacement of the steam locomotive for electric and electric-diesel locomotives, changing part of the railway plan, removal of railways and loss of function of the buildings, extinction of passenger trains, which led the stations to lose its main purpose: people transport. 53% of the stations built inside the study area were demolished and most of them are in rural areas. There are several situations: stations on a precarious conservation state, most of them in the city s rural area, stations being used in urban and rural areas with new uses, stations working with cargo and goods transportation. The stations in Triângulo Mineiro and Alto Paranaíba area in Minas Gerais are the object of this dissertation, wherein the main interest lies on the stations that are in operation, 21 buildings, seeking to verify their conservation state, their agents and role in preserving the train memory. Maps, charts and tables were made for this collection s understanding, having visited the stations that are listed by the cultural heritage and the ones that are in operation with new functions. Field records were made allowing the understanding of these properties in operation. It is observed that only the buildings listing, despite ensuring the non-demolition, does not help on the use and preservation of these stations, because there are some buildings that have this protection level, but are abandoned and in disrepair. The use of these stations by a train company, operating with cargo and goods transportation do not also guarantee the buildings preservation, as they are not treated with any preservation interest, their maintenance are precarious. The using by these companies are various, however, only a few stations have internal spaces dedicated to the railroad memory. Most of the stations did not have preservation projects with architects and specialists participation and the major concern, during maintenance process, is on the building s external part. The stations conservation begins on the local government interest, that preserve these properties, most of them are in urban areas, the major challenge is on their using definition and occupancy, especially in the countryside, wherein the buildings uses must be sustainable, as regards the appreciation and management of this heritage.
Resumo:
A technique for analysing exhaust emission plumes from unmodified locomotives under real world conditions is described and applied to the task of characterizing plumes from railway trains servicing an Australian shipping port. The method utilizes the simultaneous measurement, downwind of the railway line, of the following pollutants; particle number, PM2.5 mass fraction, SO2, NOx and CO2, with the last of these being used as an indicator of fuel combustion. Emission factors are then derived, in terms of number of particles and mass of pollutant emitted per unit mass of fuel consumed. Particle number size distributions are also presented. The practical advantages of the method are discussed including the capacity to routinely collect emission factor data for passing trains and to thereby build up a comprehensive real world database for a wide range of pollutants. Samples from 56 train movements were collected, analyzed and presented. The quantitative results for emission factors are: EF(N)=(1.7±1)×1016 kg-1, EF(PM2.5)= (1.1±0.5) g·kg-1, EF(NOx)= (28±14) g·kg-1, and EF(SO2 )= (1.4±0.4) g·kg-1. The findings are compared with comparable previously published work. Statistically significant (p<α, α=0.05) correlations within the group of locomotives sampled were found between the emission factors for particle number and both SO2 and NOx.
Resumo:
The emission factors of a bus fleet consisting of approximately three hundreds diesel powered buses were measured in a tunnel study under well controlled conditions during a two-day monitoring campaign in Brisbane. The number concentration of particles in the size range 0.017-0.7 m was monitored simultaneously by two Scanning Mobility Particle Sizers located at the tunnel’s entrance and exit. The mean value of the number emission factors was found to be (2.44±1.41)×1014 particles km-1. The results are in good agreement with the emission factors determined from steady-state dynamometer testing of 12 buses from the same Brisbane City bus fleet, thus indicating that when carefully designed, both approaches, the dynamometer and on-road studies, can provide comparable results, applicable for the assessment of the effect of traffic emissions on airborne particle pollution.
Resumo:
Exhaust emissions from thirteen compressed natural gas (CNG) and nine ultralow sulphur diesel in-service transport buses were monitored on a chassis dynamometer. Measurements were carried out at idle and at three steady engine loads of 25%, 50% and 100% of maximum power at a fixed speed of 60 kmph. Emission factors were estimated for particle mass and number, carbon dioxide and oxides of nitrogen for two types of CNG buses (Scania and MAN, compatible with Euro 2 and 3 emission standards, respectively) and two types of diesel buses (Volvo Pre-Euro/Euro1 and Mercedez OC500 Euro3). All emission factors increased with load. The median particle mass emission factor for the CNG buses was less than 1% of that from the diesel buses at all loads. However, the particle number emission factors did not show a statistically significant difference between buses operating on the two types of fuel. In this paper, for the very first time, particle number emission factors are presented at four steady state engine loads for CNG buses. Median values ranged from the order of 1012 particles min-1 at idle to 1015 particles km-1 at full power. Most of the particles observed in the CNG emissions were in the nanoparticle size range and likely to be composed of volatile organic compounds The CO2 emission factors were about 20% to 30% greater for the diesel buses over the CNG buses, while the oxides of nitrogen emission factors did not show any difference due to the large variation between buses.