957 resultados para Electrical cables


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This article is intended to evaluate the density and the mechanical, acoustic and thermal properties of compression moulded plates composed of granulate from electrical cables wastes. Those cable wastes are the insulation part from the electric cables, and are composed of PVC, PE, EMP and PEX rubber. After these materiais lose their initial properties and cease to be useful as insulation material, due to safety requirements, it is possible to reuse them into new applications like industrial or playground floorings, as sound insulation material to be applied in walls or floors, or to dampen vibrations from equipments. Recovering electric cable waste has been a major concern to the European Commission due to its leveis of toxicity when incineration and land fill ing is the solution to dispose this material. Such as the European Commission's study for DG Xl[1] suggested that recycling may be the most favourable future waste management option.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Actualmente tem sido dada uma importância à energia de origem renovável. No entanto, o conceito de fonte de energia renovável não significa necessariamente que essas fontes sejam renováveis, para o que seria necessário considerar os impactos que a sua produção e utilização tem ao nível dos três pilares fundamentais da sustentabilidade: o social, o ambiental e o económico. Num mundo cada vez mais insustentável, a busca por melhorias ao nível da eficiência energética constitui uma prioridade. A dissertação que aqui se apresenta visa essencialmente analisar o problema que representa a produção distribuída de energia para a amplitude e forma de onda de tensão na rede de distribuição. Sendo do conhecimento dos especialistas que as cavas de tensão constituem um problema significativo, a questão das harmónicas ainda é uma área em desenvolvimento. No caso de estudo que é apresentado no âmbito desta dissertação, pretendeu-se analisar esta problemática ao nível da amplitude e forma da onda de tensão na rede de distribuição. Foi possível tirar algumas ilações relativas ao impacto que a microprodução a partir de fonte FV tem, através da utilização do equipamento de medição adequado. Conclui-se que existe, efetivamente, uma distorção da forma de onda, distorção essa que constitui não só uma desvantagem para os consumidores de energia, visto poder causar efeitos colaterais nos seus equipamentos, mas também um problema de eficiência energética, obrigando a que no futuro, e assumindo que estes sistemas vão proliferar em larga escala a nível global, exista uma exigência em termos de requisitos técnicos como o aumento da secção do cabo elétrico e a respectiva ramificação da rede para a distribuição de energia que por si só, é insustentável.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Tässä työssä käydään lyhyesti läpi sähkökaapeleiden haurastumisilmiöt säteilyn ja lämmön osalta, näiden yhteisvaikutus kaapelimateriaaleihin sekä yleisimpien ydinvoimalaitoksilla käytettävien kaapeleiden ominaisuuksia. Työssä esitellään myös kaapeleiden kelpoistukseen käytettäviä menetelmiä sekä maailmalla tehtyjä tutkimuksia.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Electromagnetic induction (EMI) method results are shown for vertical magnetic dipole (VMD) configuration by using the EM38 equipment. Performance in the location of metallic pipes and electrical cables is compared as a function of instrumental drift correction by linear and quadratic adjusting under controlled conditions. Metallic pipes and electrical cables are buried at the IAG/USP shallow geophysical test site in Sao Paulo City. Brazil. Results show that apparent electrical conductivity and magnetic susceptibility data were affected by ambient temperature variation. In order to obtain better contrast between background and metallic targets it was necessary to correct the drift. This correction was accomplished by using linear and quadratic relation between conductivity/susceptibility and temperature intending comparative studies. The correction of temperature drift by using a quadratic relation was effective, showing that all metallic targets were located as well deeper targets were also improved. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective. Measure physical therapists' exposure to the electric and magnetic fields produced by 17 shortwave diathermy devices in physical therapy clinics in the city of Presidente Prudente, São Paulo State, Brazil. Compare the observed values with the exposure levels recommended by the International Commission on Non-ionizing Radiation Protection (ICNIRP). Observe the efficacy of Faraday cages as a means of protecting physical therapists from exposure to oscillating electric and magnetic fields.Methods. Electric and magnetic field measurements were taken at four points during actual physical therapy sessions: in proximity to the operator's pelvis and head, the devices' electrical cables, and the electrodes. The measuring equipment was a Wandel & Goltermann EMR-200.Results. The values obtained in proximity to the electrodes and cables were 10 to 30 times higher than ICNIRP's recommended occupational reference levels. In the shortwave diathermy treatment rooms with Faraday cages, the fields were even higher than in treatment rooms not so equipped-principally the magnetic field, where the values were more than 100 times higher than the ICNIRP exposure limit.Conclusions. The electric and magnetic field intensities obtained in this study are generally above the exposure levels recommend in ICNIRP standards. It was also observed that the Faraday cage offers physical therapists no protection, and instead, increases their level of exposure.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In the last decades it has been observed a substantial developing of the electrical energy demand in the societies all over the World. In consequence the electrical energy distribution companies are increasing the quantity of electrical energy through the electrical energy conductor cables, which had grown the sag in the towers of energy transmission. Furthermore, the construction of more transmission towers brings a lot of troubles due environmental protection laws. In this way, looking forward to increase the quantity of electrical energy transmitted through electrical cables conductors, reduce the need of constructing new transmission towers and the sag in them, we suggest in this work the replace of the traditional core of the conductors cables commonly used, made of steel, by a core made by a composite material, which one is made by carbon fibers pultruded with polymeric resins as matrix. In a order to evaluate if the resins more commonly used in structural composites can be applied as matrix to make possible to use the composite material as a core, we made carbon fibers systems pultruded with epoxy, phenolic and polyester resins as matrix and a mechanic and physic-chemistry characterization was done on the systems by Tensile and Poisson tests, differential sprobe calorimetry (DSC), thermogravimetric analysis (TGA) and Fourier transformed infrared spectroscopy (FTIR), following their correspondents standards

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The most usual method to fix supports that hold the vast majority of electrical cables on an aircraft is accomplished by using, for this purpose, rivets. However, this procedure may some cause some inconveniences such as the need of effecting holes in the structure that is intended to fix these supports, thus decreasing resistance of the structure. In order to have an alternative to seek an increase in the performance of structured materials, the aircraft industry, like other industries, have been studying the use of collage as a method of replacing this usual forms. Against this backdrop, this paper aims to assess the strength and durability of a joint bonded using the adhesive EA9394, manufactured by company Henkel Corporation, and perform a careful survey of the mechanical performance of riveted structures, taking into account different types of conditioning environment and thus create a database that can be used by the aerospace industry

Relevância:

60.00% 60.00%

Publicador:

Resumo:

"September 1995"--P. iii.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Dissertação apresentada para obtenção do Grau de Doutor em Engenharia Física - Física Aplicada pela Universidade Nova de Lisboa, Faculdade de Ciências e Tecnologia

Relevância:

40.00% 40.00%

Publicador:

Resumo:

cover-title

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The research of power-line communications has been concentrated on home automation, broadband indoor communications and broadband data transfer in a low voltage distribution network between home andtransformer station. There has not been carried out much research work that is focused on the high frequency characteristics of industrial low voltage distribution networks. The industrial low voltage distribution network may be utilised as a communication channel to data transfer required by the on-line condition monitoring of electric motors. The advantage of using power-line data transfer is that it does not require the installing of new cables. In the first part of this work, the characteristics of industrial low voltage distribution network components and the pilot distribution network are measured and modelled with respect topower-line communications frequencies up to 30 MHz. The distributed inductances, capacitances and attenuation of MCMK type low voltage power cables are measured in the frequency band 100 kHz - 30 MHz and an attenuation formula for the cables is formed based on the measurements. The input impedances of electric motors (15-250 kW) are measured using several signal couplings and measurement based input impedance model for electric motor with a slotted stator is formed. The model is designed for the frequency band 10 kHz - 30 MHz. Next, the effect of DC (direct current) voltage link inverter on power line data transfer is briefly analysed. Finally, a pilot distribution network is formed and signal attenuation in communication channels in the pilot environment is measured. The results are compared with the simulations that are carried out utilising the developed models and measured parameters for cables and motors. In the second part of this work, a narrowband power-line data transfer system is developed for the data transfer ofon-line condition monitoring of electric motors. It is developed using standardintegrated circuits. The system is tested in the pilot environment and the applicability of the system for the data transfer required by the on-line condition monitoring of electric motors is analysed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper focus on the problem of locating single-phase faults in mixed distribution electric systems, with overhead lines and underground cables, using voltage and current measurements at the sending-end and sequence model of the network. Since calculating series impedance for underground cables is not as simple as in the case of overhead lines, the paper proposes a methodology to obtain an estimation of zero-sequence impedance of underground cables starting from previous single-faults occurred in the system, in which an electric arc occurred at the fault location. For this reason, the signal is previously pretreated to eliminate its peaks voltage and the analysis can be done working with a signal as close as a sinus wave as possible

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Insulating oils are a major component of high voltage plant, including transformers, switchgear and cables. Consequentially, in terms of plant failure, changes in the electrical characteristics of the oil during ageing are of crucial importance. To address this issue, commercial insulating oil was subjected to controlled ageing under laboratory conditions. The electrical properties of the aged oils were then characterized using dielectric spectroscopy. The data suggest that a degree of electrical conductivity occurs in the aged oils, which reduces the insulating properties of the oil as ageing proceeds. The role of atmosphere and additives on the electrical properties of the oils were also explored. Results are compared with model samples, which contain known amounts of materials that may occur as by-products of the ageing process.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Nowadays, many investments have been made in the area of superconductor materials, with the aim to improve their potential technological applications. Applications on the energy transport using cables, to get high resolution images in the medicine use high magnetic fields, high speed signals use superconductor devices all of them are in crescent evidence and they are showing that the future is coming and next for this new kind of materials. Obviously that everything of this is possible due to the increasing of research with new materials, where the synthesis, characterization and applications are of the mainly objective of these researches. The production of cable for the energy transport has been in advanced stage as the bulks production is too. However, the film production that to aim at the electronic devices area is not as developed or it still need expensive investments. Thinking about that, we are developing a research where we may increase the relation of cost/benefits. Thereby, we are applying the polymeric precursors method to obtain films that will be used in the built of electronic devices. Thin films (mono and multilayers, on crystalline or metallic substrates, controlled thickness) of the BSCCO system have been obtained from dip coating deposition process with excellent results in terms of preferential orientation, controlled thickness, a large area, which may indicate future applications. Based on these results, we present an electrical circuit and their principal characteristics as superconductor transition (85K), transport current density and structure. DC four probes method, scanning electron microscopy, digital optical microscopy and X-ray diffractometry were some techniques used for the characterization of this superconductor electric device. © 2006 Materials Research Society.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Investigation on impulsive signals, originated from Partial Discharge (PD) phenomena, represents an effective tool for preventing electric failures in High Voltage (HV) and Medium Voltage (MV) systems. The determination of both sensors and instruments bandwidths is the key to achieve meaningful measurements, that is to say, obtaining the maximum Signal-To-Noise Ratio (SNR). The optimum bandwidth depends on the characteristics of the system under test, which can be often represented as a transmission line characterized by signal attenuation and dispersion phenomena. It is therefore necessary to develop both models and techniques which can characterize accurately the PD propagation mechanisms in each system and work out the frequency characteristics of the PD pulses at detection point, in order to design proper sensors able to carry out PD measurement on-line with maximum SNR. Analytical models will be devised in order to predict PD propagation in MV apparatuses. Furthermore, simulation tools will be used where complex geometries make analytical models to be unfeasible. In particular, PD propagation in MV cables, transformers and switchgears will be investigated, taking into account both irradiated and conducted signals associated to PD events, in order to design proper sensors.