990 resultados para Electric parameters
Resumo:
This article shows an analysis of the longitudinal electric parameters of a three-phase transmission line/section using a 280-meter high steel tower. This characteristic, the height of the line conductors and distance between them, are intrinsic related to the longitudinal and transversal parameters of the line. By this means, an accurate study was carried out in order to show the electric variations between a transmission line using the new technology and a three-phase conventional 440 kV line for a wide range of frequencies and a variable soil resistivity. In addition, by using a digital line model, simulations are carried out in time domain to analyze critical overvoltage transients on the studied line. © 2011 IEEE.
Resumo:
This thesis deals with theoretical modeling of the electrodynamics of auroral ionospheres. In the five research articles forming the main part of the thesis we have concentrated on two main themes: Development of new data-analysis techniques and study of inductive phenomena in the ionospheric electrodynamics. The introductory part of the thesis provides a background for these new results and places them in the wider context of ionospheric research. In this thesis we have developed a new tool (called 1D SECS) for analysing ground based magnetic measurements from a 1-dimensional magnetometer chain (usually aligned in the North-South direction) and a new method for obtaining ionospheric electric field from combined ground based magnetic measurements and estimated ionospheric electric conductance. Both these methods are based on earlier work, but contain important new features: 1D SECS respects the spherical geometry of large scale ionospheric electrojet systems and due to an innovative way of implementing boundary conditions the new method for obtaining electric fields can be applied also at local scale studies. These new calculation methods have been tested using both simulated and real data. The tests indicate that the new methods are more reliable than the previous techniques. Inductive phenomena are intimately related to temporal changes in electric currents. As the large scale ionospheric current systems change relatively slowly, in time scales of several minutes or hours, inductive effects are usually assumed to be negligible. However, during the past ten years, it has been realised that induction can play an important part in some ionospheric phenomena. In this thesis we have studied the role of inductive electric fields and currents in ionospheric electrodynamics. We have formulated the induction problem so that only ionospheric electric parameters are used in the calculations. This is in contrast to previous studies, which require knowledge of the magnetospheric-ionosphere coupling. We have applied our technique to several realistic models of typical auroral phenomena. The results indicate that inductive electric fields and currents are locally important during the most dynamical phenomena (like the westward travelling surge, WTS). In these situations induction may locally contribute up to 20-30% of the total ionospheric electric field and currents. Inductive phenomena do also change the field-aligned currents flowing between the ionosphere and magnetosphere, thus modifying the coupling between the two regions.
Resumo:
O objetivo do presente trabalho foi estudar o comportamento dos potenciais superficiais e do perfil de potencial atraves da membrana de eritr ocito em func ao da forca i onica e das cargas superficiais, usando um modelo que leva em conta as cargas el etricas do glicoc alix e das proteınas citoplasm aticas, al em das cargas superficiais da bicamada lipıdica e os efeitos dos eletr olitos divalentes. Programas especıficos em linguagem C foram elaborados para o c alculo desses potenciais, tomando como dados num ericos resultados experimentais de medidas de mobilidade eletrofor etica de eritr ocitos para diferentes valores de forca i onica. Neste c alculo, o metodo para tratamento dos dados eletrofor eticos indicado por Hsu et al.[57] foi incluıdo em nosso modelo. A equac ao de Poisson-Boltzmann nao linear foi resolvida por computac ao num erica, usando o metodo de Runge-Kutta de quarta ordem, obtendo-se os perfis de potencial. Os resultados mostraram que a estimativa da densidade de carga el etrica na superfıcie de c elulas usando a equac ao cl assica de Helmholtz-Smoluchowski conduz a valores que nao conseguem refletir as forcas que regem o comportamento eletrofor etico das mesmas. O presente modelo gerou valores de potenciais superficiais e perfis de potencial para a membrana do eritr ocito bem distintos daqueles obtidos anteriormente para um modelo descrito por uma equac ao de Poisson-Boltzmann linear. Nossos resultados confirmam que a avaliac ao de parametros el etricos superficiais da membrana de eritr ocito, envolvendo dados oriundos de eletroforese, deve incluir c alculos hidrodin amicos al em de eletroest aticos, como sugerido por Hsu et al. [57].
Resumo:
Low resistivity reservoir is a special reservoir which is different from normal reservoir in identification and evaluation.Through core experiment and analysis, the achievement of which resistivity is resulted from clay additive electric conductivities and high bound water saturation in Junggar basin is gained. For accurately evaluating low resistivity, a good many of experiment have been completed, such as resistivity index and formation factor in hi^jher temperature and higher pressure, semi-permeability board, cation exchange, bound water, NMR (nucleus magnetism response), non-Nad water in different temperature and salinity, the experiments result show that lower resistivity has complex relation with these electric-parameters and chloric ion content in non-NaCl water.Based on comprehensive interpretation of NMR and normal resistivity data, the volume of moved water, bound water, moved oil and residual oil in the strata can be determined quantitatively and which have significant influence on reservoir recognition and perforation optimized.Experiment data (SEM mold, thin section, X ray diffraction, mercury penetration) can be used to analysis low resistivity forming and the relation between low resistivity and pore texture, to set up relation between porosity, permeability and petrophysical property. The reservoir was sorted, evaluated and described. The oil bedding in southern margin of Junggar basin is low porosity, low resistivity reservoir.Based on invasion theory of electric well-logging, modelling and inversion of resistivity well-logging are accomplished. For enhancing low resistivity resulted from higher bound water saturation and cation exchange, invasion period, invasion radius, the relation between fluid distribution in pore and response of laterolog logging have been studied. Virgin zone resistivity, invasion zone resistivity and invasion radius were inversed and which enhanced evaluation accuracy of reservoir. The method was used to process well-logging data in Luliang oilfield and southern margin in Junggar basin, and reservoir resistivity was enhanced effectively, appropriate oil saturation gained and it has better effect on oil exploration.
Resumo:
This article analyzes the electrical parameters of a 3-phase transmission line using a 280-m-high steel tower that has been proposed for the Amazon transmission system in Brazil. The height of the line conductors and the distance between them are intrinsically related to the longitudinal and transverse parameters of the line. Hence, an accurate study is carried out in order to show the electrical variations between a transmission line using the new technology and a conventional 3-phase 440-kV line, considering a wide range of frequencies and variable soil resistivity. First, a brief review of the fundamental theory of line parameters is presented. In addition, by using a digital line model, simulations are carried out in the time domain to analyze possible and critical over-voltage transients on the proposed line representation.
Resumo:
This paper describes an alternative procedure to obtain an equivalent conductor from a bundled conductor, taking into account the distribution of the current in subcondutors of the bundle. Firstly, it is introduced a brief background about the concept of Geometric Mean Radius (GMR) and how this methodology is applied to define an equivalent conductor and its electric parameters. Emphasizing that the classical procedure, using GMR, is limited to premise which the current is equally distributed through subconductors. Afterwards, it is described the development of proposed method and applications for an equivalent conductor obtained from a conventional transmission line bundled conductor and from an equivalent conductor based on a bundle with compressed SF(6) insulation system, where the current is unequally distributed through subconductors.
Resumo:
The electric and dielectric properties of the grain boundary of Na0.85Li0.15NbO3 lead-free ferroelectric-semiconductor perovskite were investigated. The impedance spectroscopy was carried out as a function of a thermal cycle. The sodium lithium niobate was synthesized by a chemical route based on the evaporation method. Dense ceramic, relative density of 97%, was prepared at 1423 K for 2 h in air atmosphere. ac measurements were carried out in the frequency range of 5 Hz-13 MHz and from 673 to 1023 K. Theoretical adjust of the impedance data was performed to deriving the electric parameters of the grain boundary. The electric conductivity follows the Arrhenius law, with activation energy values equal to 1.55 and 1.54 eV for heating and cooling cycle, respectively. The nonferroelectric state of the grain boundary and its correlation with symmetry are discussed in the temperature domain. (C) 2003 American Institute of Physics.
Resumo:
This paper represents the results of the work carried out in order to study the condition of seasonal consumer, the load factor and the more convenient tariff for a sugar mill located in the Vale do Paranapanema, SP, Brazil. Therefore, data of consume and registered demand were collected during the quadriennium 1990 to 1994. The studies showed that the factory did not maintain the condition of seasonal consumer of electric energy during the analysed period. Low values of the load factor observed in the period showed a non rational use of electric energy supplied by the concessionary. The results showed that only in one situation (load retired in top equal to 90%) the most convenient tariff is the horo-sazonal azul. In the other situations the most convenient tariff is the conventional one.
Resumo:
Pós-graduação em Engenharia Mecânica - FEG
Resumo:
Pós-graduação em Agronomia (Energia na Agricultura) - FCA
Resumo:
Pós-graduação em Agronomia (Energia na Agricultura) - FCA
Resumo:
Pós-graduação em Agronomia (Energia na Agricultura) - FCA
Resumo:
Pós-graduação em Agronomia (Energia na Agricultura) - FCA
Resumo:
Polymer aluminum electrolytic capacitors were introduced to provide an alternative to liquid electrolytic capacitors. Polymer electrolytic capacitor electric parameters of capacitance and ESR are less temperature dependent than those of liquid aluminum electrolytic capacitors. Furthermore, the electrical conductivity of the polymer used in these capacitors (poly-3,4ethylenedioxithiophene) is orders of magnitude higher than the electrolytes used in liquid aluminum electrolytic capacitors, resulting in capacitors with much lower equivalent series resistance which are suitable for use in high ripple-current applications. The presence of the moisture-sensitive polymer PEDOT introduces concerns on the reliability of polymer aluminum capacitors in high humidity conditions. Highly accelerated stress testing (or HAST) (110ºC, 85% relative humidity) of polymer aluminum capacitors in which the parts were subjected to unbiased HAST conditions for 700 hours was done to understand the design factors that contribute to the susceptibility to degradation of a polymer aluminum electrolytic capacitor exposed to HAST conditions. A large scale study involving capacitors of different electrical ratings (2.5V – 16V, 100µF – 470 µF), mounting types (surface-mount and through-hole) and manufacturers (6 different manufacturers) was done to determine a relationship between package geometry and reliability in high temperature-humidity conditions. A Geometry-Based HAST test in which the part selection limited variations between capacitor samples to geometric differences only was done to analyze the effect of package geometry on humidity-driven degradation more closely. Raman spectroscopy, x-ray imaging, environmental scanning electron microscopy, and destructive analysis of the capacitors after HAST exposure was done to determine the failure mechanisms of polymer aluminum capacitors under high temperature-humidity conditions.