994 resultados para Electric equipment


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Underground hardrock mining can be very energy intensive and in large part this can be attributed to the power consumption of underground ventilation systems. In general, the power consumed by a mine’s ventilation system and its overall scale are closely related to the amount of diesel power in operation. This is because diesel exhaust is a major source of underground air pollution, including diesel particulate matter (DPM), NO2 and heat, and because regulations tie air volumes to diesel engines. Furthermore, assuming the size of airways remains constant, the power consumption of the main system increases exponentially with the volume of air supplied to the mine. Therefore large diesel fleets lead to increased energy consumption and can also necessitate large capital expenditures on ventilation infrastructure in order to manage power requirements. Meeting ventilation requirements for equipment in a heading can result in a similar scenario with the biggest pieces leading to higher energy consumption and potentially necessitating larger ventilation tubing and taller drifts. Depending on the climate where the mine is located, large volumes of air can have a third impact on ventilation costs if heating or cooling the air is necessary. Annual heating and cooling costs, as well as the cost of the associated infrastructure, are directly related to the volume of air sent underground. This thesis considers electric mining equipment as a means for reducing the intensity and cost of energy consumption at underground, hardrock mines. Potentially, electric equipment could greatly reduce the volume of air needed to ventilate an entire mine as well as individual headings because they do not emit many of the contaminants found in diesel exhaust and because regulations do not connect air volumes to electric motors. Because of the exponential relationship between power consumption and air volumes, this could greatly reduce the amount of power required for mine ventilation as well as the capital cost of ventilation infrastructure. As heating and cooling costs are also directly linked to air volumes, the cost and energy intensity of heating and cooling the air would also be significantly reduced. A further incentive is that powering equipment from the grid is substantially cheaper than fuelling them with diesel and can also produce far fewer GHGs. Therefore, by eliminating diesel from the underground workers will enjoy safer working conditions and operators and society at large will gain from a smaller impact on the environment. Despite their significant potential, in order to produce a credible economic assessment of electric mining equipment their impact on underground systems must be understood and considered in their evaluation. Accordingly, a good deal of this thesis reviews technical considerations related to the use of electric mining equipment, especially ones that impact the economics of their implementation. The goal of this thesis will then be to present the economic potential of implementing the equipment, as well as to outline the key inputs which are necessary to support an evaluation and to provide a model and an approach which can be used by others if the relevant information is available and acceptable assumptions can be made.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This present Thesis, is explorer work and presents an analysis of e-wastes of the industry of cellular mobile telephony, evaluating the evolution of the telecommunications nets and as if it holds the global and Brazilian market of cellular telephony. It approaches the elements gifts in the cellular devices that can badly cause to the environment and the health, the discarding of the devices in end of life cycle is made. It analyzes the new European regulation of electric equipment residues and electronic, the WEEE, as it influenced the strategy of the companies manufacturers of mobile phone cellular and of that she forms is possible to create a Brazilian national industry for recycling of devices of cellular, with conditions to globally competition. For this some possible models of being implanted in Brazil are presented. The project of law 203/91 on solid residues is argued and as it would be interesting if to persist some proposals presented to the project, to create a Brazilian market of recycling with capacity of global competition for use to advantage of the European regulation if to get a competitive advantage

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A model for preventive control in electrical systems is presented, taking into account the dynamic aspects of the network. Among these aspects, the effects provoked by perturbations which cause oscillations in synchronous machine angles (transient stability), such as electric equipment outages and short circuits, are presented. The energy function is used to measure the stability of the system using a procedure defined as the security margin. The control actions employed are load shedding and generation reallocation. An application of the methodology to a system located in southern Brazil, which is composed of 10 synchronous machines, 45 busses, and 72 transmission lines. The results confirm the theoretical studies.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Reliability is a key aspect in power system design and planning. Maintaining a reliable power system is a very important issue for their design and operation. Under the new competitive framework of the electricity sector, power systems find ever more and more strained to operate near their limits. Under this new scenario, it is crucial for the system operator to use tools that facilitate an energy dispatch that minimizes possible power cuts. This paper presents a mathematical model to calculate an energy dispatch that considers security constraints (single contingencies in transmission lines and transformers). The model involves pool markets and fixed bilateral contracts. Traditional methodologies that include security constraints are usually based in multistage dispatch processes. In this case, we propose a single-stage model that avoids the economic inefficiencies which result when conventional multi-stage dispatch approaches are applied. The proposed model includes an AC representation of the transport system and allows calculating the cost overruns incurred in due to reliability restrictions. We found that complying with fixed bilateral contracts, when they go above certain levels, might lead to congestion problems in transmission lines.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper proposes and describes a high power factor AC-AC converter for naval applications using Permanent Magnet Generator (PMG). The three-phase output voltages of the PMG vary from 260 Vrms (220 Hz) to 380 Vrms (360 Hz), depending on load conditions. The proposed converter consists of a Y-/ΔY power transformer, which provides electrical isolation between the PMG and remaining stages, and a twelve-pulse uncontrolled rectifier stage directly connected to a single-phase inverter stage, without the use of an intermediary DC-DC topology. This proposal results in more simplicity for the overall circuitry, assuring robustness, reliability and reduced costs. Furthermore, the multipulse rectifier stage is capable to provide high power factor and low total harmonic distortion for the input currents of the converter. The single-phase inverter stage was designed to operate with wide range of DC bus voltage, maintaining 120 Vrms, 60 Hz output. The control philosophy, implemented in a digital signal processor (DSP) which also contains protection routines, alows series connections between two identical converters, achieving 240 Vrms, 60 Hz total output voltage. Measured total harmonic distortion for the AC output voltage is lower than 2% and the input power factor is 0.93 at 3.6kW nominal load. © 2010 IEEE.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The Brazilian National Electricity Conservation Program - PROCEL - runs regular surveys in the electric-energy-consumption market. These studies are used as valuable data to better plan the actions of this program. These data also evaluate the program's performance by identifying the level of penetration of the most efficient electric equipment within the residential sector. PROCEL's main lines of action is to promote and make available the most efficient technologies. Based on the results from the latest survey, it is estimated that 24% of the electric-energy consumption of the residential sector is used by electric shower devices, which instantaneously heat the water that flows through them, normally using an electric resistance of 5 kW. These are an important factor in a country where electric-heating devices are present in about 73% of Brazilian households. Keeping that in mind, the purpose of this work is to present the main results of the Brazilian Solar-Water-Heating-Systems Evaluation, finished in 2010, where 535 installations were visited and more than 50 researchers from different universities participated in the project. Moreover, seven Brazilian cities were selected to be studied. The information was collected from field research and statistically treated. The collected information focused on the adequacy of the project to the household, installation, operation and life cycle of the systems, as well as the users' satisfaction level. Technical questionnaires were developed to summarize all the required information, such as a Web site designed to organize and manage the data collected and a Matlab application that performed the dimensioning and F-chart systems evaluation. Quality indicators were created through a full system monitoring, with thermographic analysis and evaluation of shading influence at the system's efficiency, using the Ecotect software.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Recently there has been an important increase in electric equipment, as well as, electric power demand in aircrafts applications. This prompts to the necessity of efficient, reliable, and low-weight converters, especially rectifiers from 115VAC to 270VDC because these voltages are used in power distribution. In order to obtain a high efficiency, in aircraft application where the derating in semiconductors is high, normally several semiconductors are used in parallel to decrease the conduction losses. However, this is in conflict with high reliability. To match both goals of high efficiency and reliability, this work proposes an interleaved multi-cell rectifier system, employing several converter cells in parallel instead of parallel-connected semiconductors. In this work a 10kW multi-cell isolated rectifier system has been designed where each cell is composed of a buck type rectifier and a full bridge DC-DC converter. The implemented system exhibits 91% of efficiency, high power density (10kW/10kg), low THD (2.5%), and n−1 fault tolerance which complies, with military aircraft standards.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Article is devoted to design of optimum electromagnets for magnetic levitation of transport systems. The method of electromagnets design based on the inverse problem solution of electrical equipment is offered. The method differs from known by introducing a stage of minimization the target functions providing the stated levitation force and magnetic induction in a gap, and also the mass of an electromagnet. Initial values of parameters are received, using approximate formulas of the theory of electric devices and electrical equipment. The example of realization of a method is given. The received results show its high efficiency at design. It is practical to use the offered method and the computer program realizing it as a part of system of the automated design of electric equipment for transport with a magnetic levitation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this study was to evaluate the effective dose received by patients undergoing CCTA in both acquisition methods in the period June 1st to October 30th, 2013. Data collection was performed at the Clínica Sabedotti in Ponta Grossa/PR, with General Electric Equipment VCT XT, 64 detections lines. The effective dose was measured from the thirty cases randomly selected of Picture Archival and Communication System – PACS, reported by Dose Lenght Product (DLP) equipment for each examination and the conversion factor (EDLP) set by the European Commission for cardiac region (EDLP = 0.014). The results showed significant differences in radiation dose delivered to the patient according to the employee acquisition method, Retrospective or Prospective of ECG.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Restaurants in South Carolina have begun utilizing electronic tablet table top ordering and bill payment devices. The purpose and intended use of these devices is to streamline the ordering and bill payment processes by allowing restaurant patrons the ability to order food and beverages through a mobile menu and to pay for meals on demand. This advisory opinion reflects the Department’s official position regarding electronic “table top ordering devices” used by restaurants.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The report looks at experiments into electric fishing equipment and effects on salmon and trout within the Lancashire River Board. Experiments include obtaining information on voltage gradients, ascertaining what damage to fish of the larger size groups resulted from electric fishing, determining whether or not fractures could occur in coarse fish and brown trout,similar to those occurring in salmon and sea trout, and effects low temperatures have on electrofishing techniques.