1000 resultados para Edetic Acid.


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Reactive species generated by Fe0 oxidation promoted by O2 (catalyzed or not by ligands) are able to degrade contaminant compounds like the herbicide 2,4-dichlorophenoxyacetic acid. The degradation of 2,4-D was influenced by the concentrations of zero valent iron (ZVI) and different ligands, as well as by pH. In the absence of ligands, the highest 2,4-D degradation rate was obtained at pH 3, while the highest percentage degradation (50%) was achieved at pH 5 after 120 min of reaction. Among the ligands studied (DTPA, EDTA, glycine, oxalate, and citrate), only ethylenediaminetetraacetic acid (EDTA) and diethylenetriaminepentaacetic acid (DTPA) significantly enhanced oxidation of 2,4-D. This increase in oxidation was observed at all pH values tested (including neutral to alkaline conditions), indicating the feasibility of the technique for treatment of contaminated water. In the presence of EDTA, the oxidation rate was greater at pH 3 than at pH 5 or 7. Increasing the EDTA concentration increased the rate and percentage of 2,4-D degradation, however increasing the Fe0 concentration resulted in the opposite behavior. It was found that degradation of EDTA and 2,4-D occurred simultaneously, and that the new methodology avoided any 2,4-D removal by adsorption/coprecipitation. © 2013 Elsevier Ltd.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Objective: This study aims to compare the clot stabilization on root surfaces conditioned with citric acid and ethylenediaminetetraacetic acid (EDTA). Materials and methods: Scaled root samples (n = 100) were set in five groups: group I?control group (saline solution); group II (24% EDTA); group III (25% citric acid); group IV (EDTA + citric acid); group V (citric acid + EDTA). Fifty samples were assessed using the root surface modification index (RSMI). The other 50 received a blood drop after conditioning. Clot formation was assessed using blood elements adhesion index (BEAI). A blind examiner evaluated photomicrographs. Statistical analysis considered p < 0.05. Results: Groups-III and G-V attained the best results for RSMI and BEAI in comparison to control. The worst results for clot stabilization were seen in group-II. EDTA employment before citric acid (group-IV) reduced clot formation in comparison to citric acid use alone (group-III). Conclusion: Root conditioning with citric acid alone and before EDTA had the best results for smear layer removal and clot stabilization. EDTA inhibited clot stabilization on root surface and must have a residual activity once it has diminished clot adhesion to root even after citric acid conditioning. Thus, EDTA can be used to neutralize citric acid effects on periodontal cells without affecting clot stabilization. Clinical significance: To demonstrate that citric acid use on root surfaces previously affected by periodontal disease may favor clot stabilization and may have a beneficial effect on surgical outcomes. Also, EDTA can be used to neutralize citric acid effects on periodontal cells.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Includes bibliography.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The development and maintenance of the sealing of the root canal system is the key to the success of root canal treatment. The resin-based adhesive material has the potential to reduce the microleakage of the root canal because of its adhesive properties and penetration into dentinal walls. Moreover, the irrigation protocols may have an influence on the adhesiveness of resin-based sealers to root dentin. The objective of the present study was to evaluate the effect of different irrigant protocols on coronal bacterial microleakage of gutta-percha/AH Plus and Resilon/Real Seal Self-etch systems. One hundred ninety pre-molars were used. The teeth were divided into 18 experimental groups according to the irrigation protocols and filling materials used. The protocols used were: distilled water; sodium hypochlorite (NaOCl)+eDTA; NaOCl+H3PO4; NaOCl+eDTA+chlorhexidine (CHX); NaOCl+H3PO4+CHX; CHX+eDTA; CHX+ H3PO4; CHX+eDTA+CHX and CHX+H3PO4+CHX. Gutta-percha/AH Plus or Resilon/Real Seal Se were used as root-filling materials. The coronal microleakage was evaluated for 90 days against Enterococcus faecalis. Data were statistically analyzed using Kaplan-Meier survival test, Kruskal-Wallis and Mann-Whitney tests. No significant difference was verified in the groups using chlorhexidine or sodium hypochlorite during the chemo-mechanical preparation followed by eDTA or phosphoric acid for smear layer removal. The same results were found for filling materials. However, the statistical analyses revealed that a final flush with 2% chlorhexidine reduced significantly the coronal microleakage. A final flush with 2% chlorhexidine after smear layer removal reduces coronal microleakage of teeth filled with gutta-percha/AH Plus or Resilon/Real Seal SE.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Plasma clearance of (51)Cr-EDTA ((51)Cr-EDTA-Cl) is an alternative method to evaluate glomerular filtration rate (GFR). This study aimed to investigate the concordance between (51)Cr-EDTA-Cl and renal inulin clearance (In-Cl) in renal transplant recipients as well to determine the repeatability of (51)Cr-EDTA-Cl in kidney donors. Forty four kidney recipients and 22 kidney donors were enrolled. Simultaneous measurements of (51)Cr-EDTA-Cl and In-Cl were performed. A single dose of 3.7MBq of (51)Cr-EDTA was injected and the plasma disappearance curve was created by taking blood samples at 2, 4, 6 and 8 h after injection. Bland and Altman statistical approach was used to quantify the agreement between In-Cl and (51)Cr-EDTA-Cl and to determine the better concordance between all possibilities of measure for the (51)Cr-EDTA-Cl. The mean of In-Cl was 44.5 +/- 17.9 ml/min/1.73 m(2). There was a positive correlation between In-Cl and all possible measurements of (51)Cr-EDTA-Cl. (51)Cr-EDTA-Cl with two samples taken at 4 and 8 h or at 4 and 6 h presenting the narrow limits of agreement and a difference (bias) of 2.8 and 2.7 ml/min, respectively. Two plasma sampling for (51)Cr-EDTA-Cl was a reliable method to measure GFR compared with In-Cl and comprises a suitable method to be used in kidney transplanted patients.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The interaction of the T cell antigen receptor with a photoreactive antigenic peptide derivative bound covalently to the H-2Kd (Kd) molecule was studied by photoaffinity labeling on cloned, CD8 positive cytotoxic T lymphocytes. The Kd-restricted Plasmodium berghei circumsporozoite peptide 253-260 (YIPS-AEKI) was conjugated with iodo-4-azidosalicylic acid at the N terminus and with 4-azidobenzoic acid at the T cell receptor residue Lys-259. Cell-associated or soluble Kd molecules were photoaffinity-labeled with the peptide derivative by selective photoactivation of the N-terminal photoreactive group. Incubation of cell-associated or soluble covalent Kd-peptide derivative complexes (ligands) with cytotoxic T lymphocytes that recognized this peptide derivative and activation of the orthogonal photoreactive group resulted in specific photoaffinity labeling of the T cell receptor. The labeling was inhibitable by an anti-Kd antibody and was absent on Kd-restricted cytotoxic T lymphocytes of different specificity. The binding of the soluble ligand reached a maximum after 2-4 min at 37 degrees C, after 30 min at 18 degrees C, and after 3 h at 4 degrees C. In contrast, binding of the cell-associated ligand reached a transient maxima after 50 and 110 min at 37 and 18 degrees C, respectively. The degree of binding at 37 degrees C was approximately 30% lower than that at 18 degrees C. No binding took place at 4 degrees C. Inhibition studies with antibodies and drugs indicated that the binding of the cell-associated, but not the soluble ligand, was highly dependent on T cell-target cell conjugate formation, whereas the binding of the soluble ligand was greatly dependent on CD8.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The epithelial sodium channel ENaC is physiologically important in the kidney for the regulation of the extracellular fluid volume, and in the lungs for the maintenance of the appropriate airway surface liquid volume that lines the pulmonary epithelium. Besides the regulation of ENaC by hormones, intracellular factors such as Na(+) ions, pH, or Ca(2+) are responsible for fast adaptive responses of ENaC activity to changes in the intracellular milieu. In this study, we show that ENaC is rapidly and reversibly inhibited by internal sulfhydryl-reactive molecules such as methanethiosulfonate derivatives of different sizes, the metal cations Cd(2+) and Zn(2+), or copper(II) phenanthroline, a mild oxidizing agent that promotes the formation of disulfide bonds. At the single channel level, these agents applied intracellularly induce the appearance of long channel closures, suggesting an effect on ENaC gating. The intracellular reducing agent dithiothreitol fully reverses the rundown of ENaC activity in inside-out patches. Our observations suggest that changes in intracellular redox potential modulate ENaC activity and may regulate ENaC-mediated Na(+) transport in epithelia. Finally, substitution experiments reveal that multiple cysteine residues in the amino and carboxyl termini of ENaC subunits are responsible for this thiol-mediated inhibition of ENaC.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The purpose of this study was to observe the quality of seal of the glass ionomer cement, Ketac-Endo, after treatment of the root canal wall. The root canals of 140 extracted human teeth were prepared biomechanically. The root canals were treated with either EDTA or received an intracanal dressing of calcium hydroxide or camphorated paramonochlorphenol. The root canals were filled by the lateral condensation technique with gutta-percha points and the sealer Ketac-Endo, or zinc oxide-eugenol cement or Sealapex. The teeth were placed into a 2% methylene blue dye solution inside a flask, which was attached to a vacuum pump. Leakage was measured linearly. Sealapex exhibited significantly less leakage than Ketac-Endo or zinc oxide-eugenol cement (P<0.01). The use of EDTA and intermediary dressings reduced significantly (P<0.01) the leakage observed with the zinc oxide-eugenol sealer and Ketac-Endo.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The purpose of this study was to compare the removal of root surface smear layer following active application of EDTA gel and EDTA-T (texapon) gel in different concentrations (5%, 10%, 15%, 20% and 24%), using scanning electron microscopy. A total of 220 dentin blocks obtained from the root surfaces of extracted teeth were divided into 3 groups: Group I - (control) application of saline solution (n = 20); Group II - EDTA gel (pH 7.0) was applied in the following concentrations: 5%, 10%, 15%, 20% and 24% (n = 100); Group III - EDTA-T gel (pH 7.0) applied in the same concentrations described above (n = 100). The photomicrographs were evaluated by one calibrated examiner using a smear layer removal index and following statistical analysis (Kruskal-Wallis test). The results demonstrated that the specimens treated with EDTA and EDTA-T gel presented a better smear layer removal than the control group (p < 0.01); no statistically significant differences were observed between the EDTA and EDTA-T groups and between the concentrations tested (Mann-Whitney, p > 0.05). Within the limits of this study, it can be concluded that all treatment modalities effectively removed the smear layer from the root surface. The addition of texapon into the EDTA gel formulation did not increase its effectiveness.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The purpose of this study was to carry out a scanning electron microscopic (SEM) analysis of the cleaning qualities and smear layer removal from root canal walls, instrumented and irrigated with 2.5% NaOCl, 2.0% chlorhexidine and saline solutions. Fifty extracted teeth were used in this study. All teeth were radiographed to determine the existence of a single canal. The crowns were cut at the cervical limit and the root canals were instrumented with K-type files up to size 45. During root canal preparation, irrigations were made with the different solutions being evaluated: Group 1: 2.5% NaOCl (10 roots); Group 2: 2.5% NaOCl and 17% EDTA for 2 minute (10 roots); Group 3: 2.0% chlorhexidine (10 roots); Group 4: 2.0% chlorhexidine and 17% EDTA for 2 minutes (10 roots); Group 5: saline solution (5 roots); Group 6: saline solution and 17% EDTA for 2 minutes (5 roots). After instrumentation, the canals were irrigated with each one of the solutions and the roots were cut in the buccolingual direction for SEM analysis, at the cervical, middle and apical thirds, to ascertain the presence or absence of smear layer and debris. SEM analysis was performed by three calibrated examiners and scores were submitted to Kruskal-Wallis test at the significance level of p = 5%. Results showed that the use of 17% EDTA decreased the smear layer significantly (p < 0.05) for all evaluated solutions in all thirds. When EDTA was not used, a significantly higher quantity of smear layer on the apical third was observed only in the NaOCl groups. The use of 17% EDTA was significant for debris removal except for the chlorhexidine groups. The following conclusion could be drawn: the use of 17% EDTA was necessary to enhance cleanness of the root canals.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Iron deficiency is one of the most prevalent nutritional problems in the world. Iron compounds are used for the prevention and treatment of this deficiency. A double-blind randomized crossover study with 12 volunteers was carried out to compare the effect of three iron compounds, ferrous glycine chelate (GLY), ferric EDTA (EDTA), and ferrous sulfate (FS) on serum iron, and to examine serial serum iron levels. The products were offered as tablets, and blood samples were drawn hourly for 4 hours. FS produced higher serum iron levels than EDTA or GLY (P <0.05). Data for GLY and EDTA were similar. The areas under the curve (AUC) for serum iron for the different compounds gave AUCFS > AUCGLY = AUCEDTA (P < 0.05). Iron from FS had a significantly greater bioavailability than for the other two compounds. © 2004 Elsevier Inc. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Mean platelet volume (MPV), platelet distribution width (PDW) and plateletcrit (PCT) platelet parameters can be important to improve the initial identification of platelet disorders. The purpose of this study is to establish reference values for the platelet count (PLT), MPV, PDW and PCT in a population of 1346 apparently healthy adults, from both sexes, as well as to evaluate the correlations among these platelet parameters and to build the necessary nomograms for the clinical interpretations of the platelet indices. The platelet parameters were analyzed in blood samples collected into dipotassium ethylenediaminetetra-acetic acid (K 2 EDTA) by an electrical aperture-impedance method. There were non-linear and an inverse correlations between MPV and PLT, and between PDW and PLT, throughout the reference range of platelet count: the change in MPV and PDW was most accentuated at the lower platelet counts. Because of this non-linear inverse correlation, MPV versus PLT and PDW versus PLT nomograms were built. These correlations among the platelet parameters on a normal population provide a better understanding of these indices and may contribute to establish the real clinical significance of these platelet parameters in many diseases.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this study Candida albicans biofilm formation on the surface of commercially pure titanium (cp-Ti) coated with hydroxyapatite was observed by means of scanning electron microscope. The biofilm was formed after 45 days of incubation of the samples in liquid culture medium inoculated with fungus cells in a tube of polystyrene with screw cap and sterilized. After the biofilm removal with 10% EDTA solution was observed pitting on the surface of cp-Ti coated.