559 resultados para Ecografia intravascular


Relevância:

70.00% 70.00%

Publicador:

Resumo:

El objetivo del estudio es evaluar el remodelado estructural y funcional de las arterias pulmonares asociado a insuficiencia respiratoria crónica severa, mediante ecografía intravascular (IVUS). Se incluyeron 80 pacientes en estudio pretrasplante pulmonar a los que se les realizó cateterismo cardiaco derecho e IVUS de una arteria pulmonar de mediano calibre. A través del IVUS se determinó el módulo elástico, pulsatilidad y porcentaje de fibrosis arterial. La insuficiencia respiratoria crónica se asoció a una vasculopatía arterial pulmonar severa, independientemente de la presencia de hipertensión pulmonar. Los pacientes con EPOC (enfermedad pulmonar obstructiva crónica) presentaban un mayor grado de fibrosis arterial, mientras que los pacientes con EPID (enfermedad pulmonar intersticial difusa) presentaban mayor rigidez arterial.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Intravascular ultrasound (IVUS) image segmentation can provide more detailed vessel and plaque information, resulting in better diagnostics, evaluation and therapy planning. A novel automatic segmentation proposal is described herein; the method relies on a binary morphological object reconstruction to segment the coronary wall in IVUS images. First, a preprocessing followed by a feature extraction block are performed, allowing for the desired information to be extracted. Afterward, binary versions of the desired objects are reconstructed, and their contours are extracted to segment the image. The effectiveness is demonstrated by segmenting 1300 images, in which the outcomes had a strong correlation to their corresponding gold standard. Moreover, the results were also corroborated statistically by having as high as 92.72% and 91.9% of true positive area fraction for the lumen and media adventitia border, respectively. In addition, this approach can be adapted easily and applied to other related modalities, such as intravascular optical coherence tomography and intravascular magnetic resonance imaging. (E-mail: matheuscardosomg@hotmail.com) (C) 2011 World Federation for Ultrasound in Medicine & Biology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims: We aimed to evaluate if the co-localisation of calcium and necrosis in intravascular ultrasound virtual histology (IVUS-VH) is due to artefact, and whether this effect can be mathematically estimated. Methods and results: We hypothesised that, in case calcium induces an artefactual coding of necrosis, any addition in calcium content would generate an artificial increment in the necrotic tissue. Stent struts were used to simulate the ""added calcium"". The change in the amount and in the spatial localisation of necrotic tissue was evaluated before and after stenting (n=17 coronary lesions) by means of a especially developed imaging software. The area of ""calcium"" increased from a median of 0.04 mm(2) at baseline to 0.76 mm(2) after stenting (p<0.01). In parallel the median necrotic content increased from 0.19 mm(2) to 0.59 mm(2) (p<0.01). The ""added"" calcium strongly predicted a proportional increase in necrosis-coded tissue in the areas surrounding the calcium-like spots (model R(2)=0.70; p<0.001). Conclusions: Artificial addition of calcium-like elements to the atherosclerotic plaque led to an increase in necrotic tissue in virtual histology that is probably artefactual. The overestimation of necrotic tissue by calcium strictly followed a linear pattern, indicating that it may be amenable to mathematical correction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Catheter migration or catheter fracture and consequent migration of a fragment is a rare complication that occurs in 1% of the patients. Despite the low incidence, embolization may cause severe and potentially fatal complications, with the mortality rates varying between 24 and 60%. The gold standard treatment for this condition is the extraction of the fragmented catheter by the intravascular percutaneous route, through the common femoral vein. If it is not available, the extraction procedure must be performed through an alternative access. This article describes a fully successful removal of a fragmented catheter by percutaneous intravascular access obtained through the right subclavian vein.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The dispersion model with mixed boundary conditions uses a single parameter, the dispersion number, to describe the hepatic elimination of xenobiotics and endogenous substances. An implicit a priori assumption of the model is that the transit time density of intravascular indicators is approximated by an inverse Gaussian distribution. This approximation is limited in that the model poorly describes the tail part of the hepatic outflow curves of vascular indicators. A sum of two inverse Gaussian functions is proposed as ail alternative, more flexible empirical model for transit time densities of vascular references. This model suggests that a more accurate description of the tail portion of vascular reference curves yields an elimination rate constant (or intrinsic clearance) which is 40% less than predicted by the dispersion model with mixed boundary conditions. The results emphasize the need to accurately describe outflow curves in using them as a basis for determining pharmacokinetic parameters using hepatic elimination models. (C) 1997 Society for Mathematical Biology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims We have characterized the relative dispersion of vascular and extravascular markers in the limbs of three patients undergoing isolated limb perfusions with the cytotoxic melphalan for recurrent malignant melanoma both before and after melphalan dosing. Methods A bolus of injectate containing [Cr-51] labelled red blood cells, [C-14]-sucrose and [H-3]-water was injected into an iliac or femoral artery and outflow samples collected at 1 s intervals by a fraction collector. The radioactivity due to each isotype was analysed by either gamma [Cr-51] or beta [C-14 and H-3] counting. The moments of the outflow fraction-time profiles were estimated by a nonparametric (numerical integration) method and a parametric model (sum of two inverse Gaussian functions). Results The availability, mean transit time and normalised variance (CV2) obtained for labelled red blood cells, sucrose and water were similar before and after melphalan dosing and with the two methods of calculation but varied between the patients. Conclusions The vascular space is not well-stirred but characterized by a CV2 similar that reported previously for in situ rat hind limb and rat liver perfusions. A flow-limited blood-tissue exchange was observed for the permeating indicators. Administration of melphalan did not influence the distribution characteristics of the indicators.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study examined the clinical, histological, and immunohistochemical features as well as the differential diagnoses of oral intravascular papillary endothelial hyperplasia (IPEH) to aid clinicians and pathologists in its diagnosis. Clinical features of five oral IPEH cases were obtained from medical records, and all histopathological diagnoses were reviewed. Immunohistochemical reactions, including anti-CD-34, laminin, vimentin, estrogen receptor alpha, and Ki-67, were assessed. Microscopically, a reactive proliferation of vascular cells composed of small papillary structures with hypocellular and hyalinized cores arising in an organized thrombus was seen. CD-34, vimentin, and laminin staining were strongly positive, while estrogen receptor alpha was negative in all cases. A low percentage of cells were positive for Ki-67 in four of five lesions, but one case was strongly positive. A diagnosis of angiosarcoma was investigated and rejected. IPEH presents specific microscopic characteristics that along with clinical data lead to an accurate diagnosis. The general dentist, the first to participate in the diagnostic process, must share the responsibility for diagnosis with the pathologist, and they must work together to determine the correct diagnosis and management. Oral lesions of IPEH are uncommon. Their main significance is that they show a microscopic resemblance to angiosarcoma. Thus, clinicians should have more information regarding this benign entity. Finally, we suggest that in recurrent cases exhibiting strong immunolabeling of proliferative markers the possibility of angiosarcoma should be investigated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Intravascular papillary endothelial hyperplasia (IPEH) is a benign endothelial proliferation, usually intravascular, that may mimic angiosarcoma. In this report, four new cases of IPEH involving the oral region are described. The affected sites were the lower lip, labial comissure and the submandibular region. After clinical evaluation, the complete removal of the lesions showed a circumscribed and soft mass. Histologically, the major feature was a reactive proliferation of endothelial cells composed of small papillary structures with hypocellular and hyalinized cores arising in an organized thrombus. Immunohistochemical staining for CD34 was strongly positive in endothelial cells. Vimentin and laminin immunolabelling were also consistent with a vascular origin. In order to verify the proliferative potential of the lesions, the Ki-67 antibody was used, revealing low percentage of labeled cells (<20%). No immunoreactivity for GLUT-1 was observed. Since the complete removal is curative, no additional treatment was necessary, and no signs of recurrence had been observed until now. Due to the particular features of IPEH, it is important for pathologists and clinicians to become familiar with this lesion. Additionally, the specific histological arrangement, including the absence of cellular pleomorphism, mitotic activity and necrosis, represents a guide to help in the differential diagnosis. Moreover, the vascular origin and the proliferative index should be assessed by immunohistochemistry in order to provide an accurate diagnosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Today, the standard approach for the kinetic analysis of dynamic PET studies is compartment models, in which the tracer and its metabolites are confined to a few well-mixed compartments. We examine whether the standard model is suitable for modern PET data or whether theories including more physiologic realism can advance the interpretation of dynamic PET data. A more detailed microvascular theory is developed for intravascular tracers in single-capillary and multiple-capillary systems. The microvascular models, which account for concentration gradients in capillaries, are validated and compared with the standard model in a pig liver study. Methods: Eight pigs underwent a 5-min dynamic PET study after O-15-carbon monoxide inhalation. Throughout each experiment, hepatic arterial blood and portal venous blood were sampled, and flow was measured with transit-time flow meters. The hepatic dual-inlet concentration was calculated as the flow-weighted inlet concentration. Dynamic PET data were analyzed with a traditional single-compartment model and 2 microvascular models. Results: Microvascular models provided a better fit of the tissue activity of an intravascular tracer than did the compartment model. In particular, the early dynamic phase after a tracer bolus injection was much improved. The regional hepatic blood flow estimates provided by the microvascular models (1.3 +/- 0.3 mL min(-1) mL(-1) for the single-capillary model and 1.14 +/- 0.14 min(-1) mL(-1) for the multiple-capillary model) (mean +/- SEM mL of blood min(-1) mL of liver tissue(-1)) were in agreement with the total blood flow measured by flow meters and normalized to liver weight (1.03 +/- 0.12 mL min(-1) mL(-1)). Conclusion: Compared with the standard compartment model, the 2 microvascular models provide a superior description of tissue activity after an intravascular tracer bolus injection. The microvascular models include only parameters with a clear-cut physiologic interpretation and are applicable to capillary beds in any organ. In this study, the microvascular models were validated for the liver and provided quantitative regional flow estimates in agreement with flow measurements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Haptoglobin assay, a highly sensitive method to detect intravascular hemolysis was carried out in the sera of 19 patients referred to Hospital Vital Brazil with the cutaneous form of loxoscelism in order to investigate the occurrence of mild intravascular hemolysis. Data from this series did not show decreased levels haptoglobin, ruling out intravascular hemolysis in these patients with cutaneous form of loxoscelism.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RESUMO: Desenho do estudo: Estudo quantitativo, experimental prospectivo de factor único, desenho pré-teste, pós-teste. Objectivos: Determinar a efectividade da ecografia em tempo real, como Informação de Retorno Extrínseca Visual Ecográfica (IRE-VE) na performance do transverso do abdómen (TrA), em sujeitos saudáveis; analisar eventuais diferenças entre a IRE-VE e a Informação de Retorno Extrínseca Verbal Clínica (IRE-VC); medir a performance da musculatura abdominal, através das diferenças na espessura dos músculos TrA e oblíquo interno (OI) e deslizamento do TrA, em repouso e em contracção. Enquadramento: A maioria dos indivíduos não tem conhecimentos nem consciência do contributo de uma boa performance do TrA para a estabilidade da coluna lombar. Vários estudos recentes se têm dedicado a este assunto, tendo sido mostrado o importante contributo da ecografia como Informação de Retorno Extrínseca (IRE). Uma vez que o TrA e o OI contribuem para a estabilidade lombo pélvica, e que a aprendizagem do seu controlo motor é essencial para a recuperação da função, torna-se relevante clarificar o contributo da informação de retorno na primeira fase da aprendizagem da performance desses músculos, bem como encontrar as melhores estratégias para a sua realização. A ecografia foi o instrumento escolhido para servir esse objectivo. Métodos: Participaram no estudo 75 sujeitos, sem queixas lombares, com idades compreendidas entre os 18 e os 38 anos com um valor médio de 21,9 anos (±4,03), divididos aleatoriamente em três grupos com uma tarefa comum: a “Manobra do Transverso”, em que um grupo não recebeu IRE (GC), outro recebeu IRE verbal clínica e palpatória (GIRE-VC) e ooutro recebeu IRE visual ecográfica (GIRE-VE). Para efeitos de análise da contracção da musculatura abdominal, foram estudadas a espessura dos músculos TrA e OI e o deslizamento do TrA, visualizados em imagens ecográficas em tempo real, e congeladas para medição em diferido. Estes procedimentos foram apurados num estudo piloto de fidedignidade das medições em causa. Quanto à abordagem estatística das variáveis de performance muscular foi realizada uma análise da variância simples paramétrica para amostras independentes e um teste para a diferença de médias para amostras emparelhadas. Resultados: Observamos que no GC, a ausência de IRE cursou com uma performance idêntica nos dois momentos de avaliação e que nos dois grupos com IRE, das variáveis de performance, é significativamente diferente a contracção do TrA, para uma diferença de 1,95 mm no GIRE-VE (p=0,000) e de 0,84 mm no GIRE-VC (p=0,000). Ao comparar os grupos entre si houve diferenças no limiar da significância (p=0,056) para uma melhor contracção do TrA no GIRE-VE. As outras variáveis, contracção do OI e deslizamento do TrA, não revelaram efeito relacionado com a IRE em nenhum dos grupos. Conclusão: Dos resultados obtidos, podemos concluir que a IRE-VE, quando usada isoladamente, na Manobra do Transverso provoca um maior aumento na espessura do TrA, quando comparada com a IRE-VC . O uso da ecografia mostrou ser efectivo na facilitação da performance da Manobra do Transverso em sujeitos saudáveis.---------------------ABSTRACT: Study Design: Single Factor Experimental Design: Pre-Test Post-test Control Group Design. Objectives: To measure the contribution of different types of biofeedack on Transversus Abdominis (TrA) and Internal Oblique (IO) performance through changes in thickness and lateral slide of TrA anterior fascia during abdominal hollowing exercise (AHE). Background: Increasingly clinicians are using real-time ultrasound imaging as a form of supplementing feedback when teaching trunk stabilization exercises to patients; however, there has been no evidence of its effectiveness when used alone. Material and Methods: Seventy-five healthy subjects were divided randomly into 3 groups that received: group 1, no feedback; group 2, verbal and palpatory feedback, and group 3, realtime ultrasound feedback. The TrA and IO performance of each subject was twice assessed (before and after receiving feedback) when performing the AHE in a supine hook-lying position. Analysis of variance and T-test were used for the independent and paired samples, respectively, to determine significant changes in the performance of TrA and IO, based on intra and inter group analysis. Results: Group 1 had no differences between moments; group 2 had significant differences concerning TrA thickness (p=0,000) to a 0,84 mm thickness difference; group 3 had significant differences concerning TrA thickness (p=0,000) to a 1,94 mm difference; The ability to perform the AHE differed only among group 3 and group 1 (p=0.056), and only for changes in thickness of TrA muscle. No differences among groups were found neither for the lateral slide of TrA anterior fascia, nor for the internal oblique thickness. Conclusion: From the results of this study we conclude that real-time ultrasound feedback, when used alone during an AHE, can have a larger increase in TrA thickness when compared to verbal and palpatory feedback. The use of real time ultrasound showed to be effective as a feedback tool to facilitate the performance of the AHE in a supine hook-lying position in healthy subjects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A realização de ecografia está disponível em praticamente todos os Serviços de Urgência de Ginecologia/Obstetrícia. A sua utilidade na avaliação do bem-estar fetal ante-parto é indiscutível. Este trabalho tem por objectivo rever as indicações da Ecografia realizada durante o Trabalho de Parto.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A ecografia transfontanelar, permitindo identificar as modificações da superfície do cérebro relacionáveis com a idade gestacional, constitui um método não invasivo de determinação desta, necessitando de manuseamento mínimo o que representa uma vantagem relativamente a outros métodos nomeadamente no caso de o RN estar submetido a terapia intensiva. O objectivo deste trabalho foi avaliar o grau de precisão da ecografia transfontanelar para a avaliação da idade gestacional em comparação com outros métodos clássicos como os de Ballard e de Malina. O cálculo da idade gestacional em semanas foi feito com base na contagem a partir do primeiro dia da última menstruação. O estudo incidiu sobre 60 RN admitidos para a nossa UCIN tendo, para o efeito, a ecografia transfontanelar sido executada durante os primeiros três dias de vida. Para a determinação da idade gestacional foram aplicados os diagramas de correlação anátomo-ecográfica de acordo com os critérios de Murphy, Rennie e Cooke. Obteve-se uma melhor correlação entre a idade cronológica e a idade gestacional calculada pelo método ecográfico transfontanelar (r=0,834) relativamente à calculada por outros métodos, respectivamente de Ballard (r=0,775) e de Malina (r=0,713). Em suma, de acordo com a nossa experiência no âmbito da avaliação da idade gestacional em RN submetidos a terapia intensiva, a ecografia revelou-se um método mais preciso relativamente aos métodos de Ballard e de Malina.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A ecografia ganhou maior aplicabilidade na Dermatologia com o aparecimento de sondas de maior frequência que possibilitam a visualização de lesões localizadas na pele e tecido celular subcutâneo. A ecografia de alta resolução tem-se desenvolvido particularmente na área do melanoma, onde se tem posicionado não só como exame complementar à vigilância clínica, mas também como método de estadiamento ganglionar. Neste âmbito, a ecografia é mais sensível que a palpação ganglionar, mostra-se superior a outros métodos de imagem no diagnóstico precoce da metastização locoregional e, quando realizada preliminarmente em combinação com a citologia de aspiração por agulha fina, pode diminuir o número de biopsias do gânglio sentinela. Actualmente, os estudos disponíveis sugerem que a ecografia tem um papel relevante na avaliação da doença loco-regional, em particular no doente com melanoma de risco intermédio ou elevado.