995 resultados para Echo image viewer
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The determination of loin eye area (LEA) is one of the most common methods to assess carcass quality and it is possible to adjust calculations to predict meat amount in the carcass which is one of the important features in the classification process. The aim of this study was to compare different methodologies used to determine LEA in swine. Fifteen crossbred pigs, Landrace x Large White, males and females, were slaughtered at 140 days of age. After 24 hours of cooling at 4°C, the Longissimus dorsi muscle was removed from the left half part of carcasses for evaluation of LEA between the 12th and 13th rib. The methods were: point counting on plastic grid of 1 cm2 and 0.25 cm2 (PCGP 1 cm2 and PCGC 0.25 cm2 ), circumference method by Echo Image Viewer (ECHO), circumference method using AutoCad ® program (CAD) and method of weighing paper (WP). The design was completely randomized with 15 replications per treatment and the data were subjected to Pearson correlation and variance analysis. Averages were compared by Tukey test at a significance level of 5%. LEA values were: 35.84, 35.69, 33.86, 34.22 and 36.71 cm2 , for the PCGP 1 cm2 , PCGP 0.25 cm2 , ECHO, CAD and WP methods, respectively. The LEA values determined by methods PCGP 1 cm2 , PCGP 0.25 cm2 and WP were similar; however they were higher than those obtained by the ECHO and CAD methodologies (P<0.0001). PCGP 1 cm2 , PCGP 0.25 cm2 and WP methods may overestimate LEA values. The choice of method to be used should be based on its practicality and availability of resources, since the difference obtained between them is low.
Resumo:
Throughout this workshop session we have looked at various configurations of Sage as well as using the Sage UI to run Sage applications (e.g. the image viewer). More advanced usage of Sage has been demonstrated using a Sage compatible version of Paraview highlighting the potential of parallel rendering. The aim of this tutorial session is to give a practical introduction to developing visual content for a tiled display using the Sage libraries. After completing this tutorial you should have the basic tools required to develop your own custom Sage applications. This tutorial is designed for software developers and intermediate programming knowledge is assumed, along with some introductory OpenGL . You will be required to write small portions of C/C++ code to complete this worksheet. However if you do not feel comfortable writing code (or have never written in C or C++), we will be on hand throughout this session so feel free to ask for some help. We have a number of machines in this lab running a VNC client to a virtual machine running Fedora 12. You should all be able to log in with the username “escience”, and password “escience10”. Some of the commands in this worksheet require you to run them as the root user, so note the password as you may need to use it a few times. If you need to access the Internet, then use the username “qpsf01”, password “escience10”
Resumo:
De flesta har i sin närhet någon som drabbats av cancer och sjukdomsfallen har ökat genom åren. Den yrkesgrupp som ställer diagnos av denna sjukdom är patologer. Bristen på patologer är idagsläget stor och det finns därför ett behov av att finna effektiva lösningar för att möta denna brist och en ökande mängd patienter. För att digitalisera vävnadsproven som diagnostiseras, scannas dessa in med en glasscanner. Dessa digitala bildfiler kan sedan visas i ett bildvisningsprogram och delas digitalt mellan patologer på distans. Detta begrepp kallas för telepatologi. Studien utgår utifrån följande frågeställningar: Vilka krav är väsentliga och bör ingå i en utvärdering för bildvisningsprogram avsedda för diagnostik inom telepatologi? Vilket bildvisningsprogram är mest lämpat att implementeras i ett webbaserat system baserat på dessa väsentliga krav? Syftet med studien är att undersöka vilka krav som är väsentliga och bör ingå i en utvärdering av bildvisningsprogram avsedda för diagnostik inom telepatologi, samt att utföra en utvärdering av ett urval bildvisningsprogramvaror med hjälp av dessa krav. En fallstudie genomfördes med datainsamlingsmetoderna: intervjuer med två personer från studiens samarbetspartner CGM, Frågeformulär där Sveriges patologer var respondenter samt dokumentstudier för att samla in information gällande bildvisningsprogrammen. Studien tillämpar utvalda delar ur Anders G. Nilssons SIV-metod som tillvägagångsätt för att samla in krav samt för att göra ett urval av bildvisningsprogram som sedan utvärderas gentemot dessa krav. Resultaten av datainsamlingarna analyserades och ledde till ett kravdokument med väsentliga krav.Tre så kallade utslagsgivande faktorer bland dessa krav var att bildvisningsprogrammet måste vara webbaserat utan installation på klient, funktioner för in- och ut-zoomning samt panorering måste finnas. Utvärderingen av utvalda bildvisningsprogram visade slutligen att OpenSlide var mest lämpad att implementeras i ett webbaserat system.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
For the past 10 years, medical imaging techniques have been increasingly applied to forensic investigations. To obtain histological and toxicological information, tissue and liquid samples are required. In this article, we describe the development of a low-cost, secure, and reliable approach for a telematic add-on for remotely planning biopsies on the Virtobot robotic system. Data sets are encrypted and submitted over the Internet. A plugin for the OsiriX medical image viewer allows for remote planning of needle trajectories that are used for needle placement. The application of teleradiological methods to image-guided biopsy in the forensic setting has the potential to reduce costs and, in conjunction with a mobile computer tomographic scanner, allows for tissue sampling in a mass casualty situation involving nuclear, biological, or chemical agents, in a manner that minimizes the risk to involved staff.
Resumo:
Keyboards, mice, and touch screens are a potential source of infection or contamination in operating rooms, intensive care units, and autopsy suites. The authors present a low-cost prototype of a system, which allows for touch-free control of a medical image viewer. This touch-free navigation system consists of a computer system (IMac, OS X 10.6 Apple, USA) with a medical image viewer (OsiriX, OsiriX foundation, Switzerland) and a depth camera (Kinect, Microsoft, USA). They implemented software that translates the data delivered by the camera and a voice recognition software into keyboard and mouse commands, which are then passed to OsiriX. In this feasibility study, the authors introduced 10 medical professionals to the system and asked them to re-create 12 images from a CT data set. They evaluated response times and usability of the system compared with standard mouse/keyboard control. Users felt comfortable with the system after approximately 10 minutes. Response time was 120 ms. Users required 1.4 times more time to re-create an image with gesture control. Users with OsiriX experience were significantly faster using the mouse/keyboard and faster than users without prior experience. They rated the system 3.4 out of 5 for ease of use in comparison to the mouse/keyboard. The touch-free, gesture-controlled system performs favorably and removes a potential vector for infection, protecting both patients and staff. Because the camera can be quickly and easily integrated into existing systems, requires no calibration, and is low cost, the barriers to using this technology are low.
Resumo:
Modern computer graphics systems are able to construct renderings of such high quality that viewers are deceived into regarding the images as coming from a photographic source. Large amounts of computing resources are expended in this rendering process, using complex mathematical models of lighting and shading. However, psychophysical experiments have revealed that viewers only regard certain informative regions within a presented image. Furthermore, it has been shown that these visually important regions contain low-level visual feature differences that attract the attention of the viewer. This thesis will present a new approach to image synthesis that exploits these experimental findings by modulating the spatial quality of image regions by their visual importance. Efficiency gains are therefore reaped, without sacrificing much of the perceived quality of the image. Two tasks must be undertaken to achieve this goal. Firstly, the design of an appropriate region-based model of visual importance, and secondly, the modification of progressive rendering techniques to effect an importance-based rendering approach. A rule-based fuzzy logic model is presented that computes, using spatial feature differences, the relative visual importance of regions in an image. This model improves upon previous work by incorporating threshold effects induced by global feature difference distributions and by using texture concentration measures. A modified approach to progressive ray-tracing is also presented. This new approach uses the visual importance model to guide the progressive refinement of an image. In addition, this concept of visual importance has been incorporated into supersampling, texture mapping and computer animation techniques. Experimental results are presented, illustrating the efficiency gains reaped from using this method of progressive rendering. This visual importance-based rendering approach is expected to have applications in the entertainment industry, where image fidelity may be sacrificed for efficiency purposes, as long as the overall visual impression of the scene is maintained. Different aspects of the approach should find many other applications in image compression, image retrieval, progressive data transmission and active robotic vision.
Resumo:
As an artist my primary interest is in the abstract, that is in images of the imageless. I am curious about the emergence of pictorial significance and content from this unknowable space. To speak of the significance of an imageless image is also to speak of its affect. I aim to explore this both theoretically and practically. Theoretically I will explore affect through the late work of Lyotard and his notion of the affect-phrase. This is an under-examined aspect of Lyotard and demarcates a valuable way to look at the origins, impact and ramifications of affect for art. Practically I will apply these understandings to the development of my own creative work which includes both painting and digital work. My studio practice moves towards exploring the unfamiliar through the powerful and restless silence of affect.In this intense space each work or body of work 'leaks' into the next occasioning a sense of borderlessness, or of uncertainty. This interpenetration and co-mingling of conceptual and material terrains combines to present temporal and spatial slippages evident within the works themselves and their making, but it is also evident in bodies of work across the chronology of their making. Through a mapping of my own painting and digital arts practice and the utilisation of Lyotard’s notion of the affect -phrase I aim to describe the action of this ‘charged emptiness’ on creativity and explore and explain its significance on that we call image and its animation of what we call critical discourse.
Resumo:
Considering ultrasound propagation through complex composite media as an array of parallel sonic rays, a comparison of computer simulated prediction with experimental data has previously been reported for transmission mode (where one transducer serves as transmitter, the other as receiver) in a series of ten acrylic step-wedge samples, immersed in water, exhibiting varying degrees of transit time inhomogeneity. In this study, the same samples were used but in pulse-echo mode, where the same ultrasound transducer served as both transmitter and receiver, detecting both ‘primary’ (internal sample interface) and ‘secondary’ (external sample interface) echoes. A transit time spectrum (TTS) was derived, describing the proportion of sonic rays with a particular transit time. A computer simulation was performed to predict the transit time and amplitude of various echoes created, and compared with experimental data. Applying an amplitude-tolerance analysis, 91.7±3.7% of the simulated data was within ±1 standard deviation (STD) of the experimentally measured amplitude-time data. Correlation of predicted and experimental transit time spectra provided coefficients of determination (R2) ranging from 100.0% to 96.8% for the various samples tested. The results acquired from this study provide good evidence for the concept of parallel sonic rays. Further, deconvolution of experimental input and output signals has been shown to provide an effective method to identify echoes otherwise lost due to phase cancellation. Potential applications of pulse-echo ultrasound transit time spectroscopy (PE-UTTS) include improvement of ultrasound image fidelity by improving spatial resolution and reducing phase interference artefacts.
Resumo:
In most diffusion tensor imaging (DTI) studies, images are acquired with either a partial-Fourier or a parallel partial-Fourier echo-planar imaging (EPI) sequence, in order to shorten the echo time and increase the signal-to-noise ratio (SNR). However, eddy currents induced by the diffusion-sensitizing gradients can often lead to a shift of the echo in k-space, resulting in three distinct types of artifacts in partial-Fourier DTI. Here, we present an improved DTI acquisition and reconstruction scheme, capable of generating high-quality and high-SNR DTI data without eddy current-induced artifacts. This new scheme consists of three components, respectively, addressing the three distinct types of artifacts. First, a k-space energy-anchored DTI sequence is designed to recover eddy current-induced signal loss (i.e., Type 1 artifact). Second, a multischeme partial-Fourier reconstruction is used to eliminate artificial signal elevation (i.e., Type 2 artifact) associated with the conventional partial-Fourier reconstruction. Third, a signal intensity correction is applied to remove artificial signal modulations due to eddy current-induced erroneous T2(∗) -weighting (i.e., Type 3 artifact). These systematic improvements will greatly increase the consistency and accuracy of DTI measurements, expanding the utility of DTI in translational applications where quantitative robustness is much needed.
Resumo:
The coefficients of an echo canceller with a near-end section and a far-end section are usually updated with the same updating scheme, such as the LMS algorithm. A novel scheme is proposed for echo cancellation that is based on the minimisation of two different cost functions, i.e. one for the near-end section and a different one for the far-end section. The approach considered leads to a substantial improvement in performance over the LMS algorithm when it is applied to both sections of the echo canceller. The convergence properties of the algorithm are derived. The proposed scheme is also shown to be robust to noise variations. Simulation results confirm the superior performance of the new algorithm.
Resumo:
A family of stochastic gradient algorithms and their behaviour in the data echo cancellation work platform are presented. The cost function adaptation algorithms use an error exponent update strategy based on an absolute error mapping, which is updated at every iteration. The quadratic and nonquadratic cost functions are special cases of the new family. Several possible realisations are introduced using these approaches. The noisy error problem is discussed and the digital recursive filter estimator is proposed. The simulation outcomes confirm the effectiveness of the proposed family of algorithms.
Resumo:
For a digital echo canceller it is desirable to reduce the adaptation time, during which the transmission of useful data is not possible. LMS is a non-optimal algorithm in this case as the signals involved are statistically non-Gaussian. Walach and Widrow (IEEE Trans. Inform. Theory 30 (2) (March 1984) 275-283) investigated the use of a power of 4, while other research established algorithms with arbitrary integer (Pei and Tseng, IEEE J. Selected Areas Commun. 12(9)(December 1994) 1540-1547) or non-quadratic power (Shah and Cowan, IEE.Proc.-Vis. Image Signal Process. 142 (3) (June 1995) 187-191). This paper suggests that continuous and automatic, adaptation of the error exponent gives a more satisfactory result. The family of cost function adaptation (CFA) stochastic gradient algorithm proposed allows an increase in convergence rate and, an improvement of residual error. As special case the staircase CFA algorithm is first presented, then the smooth CFA is developed. Details of implementations are also discussed. Results of simulation are provided to show the properties of the proposed family of algorithms. (C) 2000 Elsevier Science B.V. All rights reserved.