983 resultados para EP SCATTERING
Resumo:
A systematic determination of the gluon distribution is of fundamental interest in understanding the parton structure Of nuclei and the QCD dynamics. Currently, the behavior of this distribution at small x (high energy) is completely undefined. In this Letter we analyze the possibility of constraining the nuclear effects present in Xg(A) using the inclusive observables which would be measured in the future electron-nucleus collider at RHIC. We demonstrate that the Study of nuclear longitudinal and charm structure functions allows to estimate the magnitude of shadowing and antishadowing effects in the nuclear gluon distribution. (C) 2008 Elsevier B.V. All rights reserved.
Resumo:
Inclusions of sp-hybridised, trans-polyacetylene [trans-(CH)x] and poly(p-phenylene vinylene) (PPV) chains are revealed using resonant Raman scattering (RRS) investigation of amorphous hydrogenated carbon (a-C:H) films in the near IR – UV range. The RRS spectra of trans-(CH)x core Ag modes and the PPV CC-H phenylene mode are found to transform and disperse as the laser excitation energy ћωL is increased from near IR through visible to UV, whereas sp-bonded inclusions only become evident in UV. This is attributed to ћωL probing of trans-(CH)x chain inhomogeneity and the distribution of chains with varying conjugation length; for PPV to the resonant probing of phelynene ring disorder; and for sp segments, to ћωL probing of a local band gap of end-terminated polyynes. The IR spectra analysis confirmed the presence of sp, trans-(CH)x and PPV inclusions. The obtained RRS results for a-C:H denote differentiation between the core Ag trans-(CH)x modes and the PPV phenylene mode. Furthermore, it was found that at various laser excitation energies the changes in Raman spectra features for trans-(CH)x segments included in an amorphous carbon matrix are the same as in bulk trans-polyacetylene. The latter finding can be used to facilitate identification of trans-(CH)x in the spectra of complex carbonaceous materials.
Resumo:
We present a novel modified theory based upon Rayleigh scattering of ultrasound from composite nanoparticles with a liquid core and solid shell. We derive closed form solutions to the scattering cross-section and have applied this model to an ultrasound contrast agent consisting of a liquid-filled core (perfluorooctyl bromide, PFOB) encapsulated by a polymer shell (poly-caprolactone, PCL). Sensitivity analysis was performed to predict the dependence of the scattering cross-section upon material and dimensional parameters. A rapid increase in the scattering cross-section was achieved by increasing the compressibility of the core, validating the incorporation of high compressibility PFOB; the compressibility of the shell had little impact on the overall scattering cross-section although a more compressible shell is desirable. Changes in the density of the shell and the core result in predicted local minima in the scattering cross-section, approximately corresponding to the PFOB-PCL contrast agent considered; hence, incorporation of a lower shell density could potentially significantly improve the scattering cross-section. A 50% reduction in shell thickness relative to external radius increased the predicted scattering cross-section by 50%. Although it has often been considered that the shell has a negative effect on the echogeneity due to its low compressibility, we have shown that it can potentially play an important role in the echogeneity of the contrast agent. The challenge for the future is to identify suitable shell and core materials that meet the predicted characteristics in order to achieve optimal echogenity.
Resumo:
Precise protein quantification is essential in clinical dietetics, particularly in the management of renal, burn and malnourished patients. The EP-10 was developed to expedite the estimation of dietary protein for nutritional assessment and recommendation. The main objective of this study was to compare the validity and efficacy of the EP-10 with the American Dietetic Association’s “Exchange List for Meal Planning” (ADA-7g) in quantifying dietary protein intake, against computerised nutrient analysis (CNA). Protein intake of 197 food records kept by healthy adult subjects in Singapore was determined thrice using three different methods – (1) EP-10, (2) ADA-7g and (3) CNA using SERVE program (Version 4.0). Assessments using the EP-10 and ADA-7g were performed by two assessors in a blind crossover manner while a third assessor performed the CNA. All assessors were blind to each other’s results. Time taken to assess a subsample (n=165) using the EP-10 and ADA-7g was also recorded. Mean difference in protein intake quantification when compared to the CNA was statistically non-significant for the EP-10 (1.4 ± 16.3 g, P = .239) and statistically significant for the ADA-7g (-2.2 ± 15.6 g, P = .046). Both the EP-10 and ADA-7g had clinically acceptable agreement with the CNA as determined via Bland-Altman plots, although it was found that EP-10 had a tendency to overestimate with protein intakes above 150 g. The EP-10 required significantly less time for protein intake quantification than the ADA-7g (mean time of 65 ± 36 seconds vs. 111 ± 40 seconds, P < .001). The EP-10 and ADA-7g are valid clinical tools for protein intake quantification in an Asian context, with EP-10 being more time efficient. However, a dietician’s discretion is needed when the EP-10 is used on protein intakes above 150g.
Resumo:
Precise protein quantification and recommendation is essential in clinical dietetics, particularly in the management of individuals with chronic kidney disease, malnutrition, burns, wounds, pressure ulcers, and those in active sports. The Expedited 10g Protein Counter (EP-10) was developed to simplify the quantification of dietary protein for assessment and recommendation of protein intake.1 Instead of using separate protein exchanges for different food groups to quantify the dietary protein intake of an individual, every exchange in the EP-10 accounts for an exchange each of 3g non-protein-rich food and 7g protein-rich food (Table 1). The EP-10 was recently validated and published in the Journal of Renal Nutrition recently.1 This study demonstrated that using the EP-10 for dietary protein intake quantification had clinically acceptable validity and reliability when compared with the conventional 7g protein exchange while requiring less time.2 In clinical practice, the use of efficient, accurate and practical methods to facilitate assessment and treatment plans is important. The EP-10 can be easily implemented in the nutrition assessment and recommendation for a patient in the clinical setting. This patient education tool was adapted from materials printed in the Journal of Renal Nutrition.1 The tool may be used as presented or adapted to assist patients to achieve their recommended daily protein intake.
Resumo:
Objective: The expedited 10g protein counter (EP-10) is a quick and valid clinical tool for dietary protein quantification. This study aims to assess the clinical effectiveness of the EP-10 in improving serum albumin and transferrin in chronic hemodialysis patients. Methods: Forty-five patients with low serum albumin (< 38 g /L) were enrolled in this study. Parameters measured included dry weight, height, dietary intake, and levels of serum albumin, transferrin, potassium, phosphate and kinetic modeling (Kt/v). The nutritional intervention incorporated the EP-10 in two ways (1)lto quantify protein intake of patients and (2)ito educate patients to meet their protein requirements. Mean values of the nutritional parameters before and after intervention were compared using paired t-test. Results: Three months after nutritional intervention, mean albumin levels increased significantly from 32.2+4.8g/L to 37.0+3.2g/L (p<0.001). Thirty-eight (84%) patients showed an increase in albumin levels while two (4%) maintained their levels. Of the thirty-six (80%) patients with low transferrin levels (<200 mg/dL), 28 (78%) had an increase and two maintained their levels post-intervention. Mean transferrin levels increased significantly from 169.4+39.9mg/dL to 180.9+38.1mg/dL (p< 0.05). Conclusion: Nutritional intervention incorporating the EP-10 method is able to make significant improvements to albumin and transferrin levels of chronic hemodialysis patients.