8 resultados para ELSD
Resumo:
Dissertação de mestrado em Técnicas de Caraterização e Análise Química
Resumo:
The interest in the use of evaporative light scattering detector (ELSD) for the analysis of different classes of natural products has grown over the years. This is because this detector has become an excellent alternative compared to other types of detectors, such as the refractive index detector and the ultraviolet (UV) detector. This review describes the basic principles of ELSD functioning and discusses the advantages and disadvantages in using an ELSD for the analysis of organic compounds. Additionaly, an overview, covering the last 23 years, of ELSD applications in natural products analysis (saponins, terpenes, carbohydrates, glycosides, alkaloids, steroids, flavonoids, peptides, polyketides, coumarins and iridoids) is presented and discussed.
Resumo:
La réduction de la taille des particules jusqu’à l’obtention de nanocristaux est l’une des approches utilisées afin d’améliorer la pénétration cutanée des médicaments à usage topique. Nous proposons que la fabrication d’une formulation semi solide (hydrogel) à base de nanosuspension de docosanol, aboutira à une diffusion du principe actif supérieure à celle du produit commercial Abreva®, à travers des membranes synthétiques de polycarbonates. Le broyage humide est la technique proposée pour la production des nanoparticules de docosanol. Nous proposons aussi la préparation d’une formulation semi-solide (hydrogel) à usage topique à partir de la nanosuspension de docosanol. La nanosuspension de docosanol est obtenue par dispersion du docosanol en solution aqueuse en présence du polymère stabilisant hydroxypropylcellulose (HPC) et du surfactant laurylsulfate de sodium (SDS) suivi d’un broyage humide à faible ou à haute énergie. L’hydrogel de docosanol nanoformulé est préparé à l’aide de la nanosuspension de docosanol qui subit une gélification par le carbopol Ultrez 21 sous agitation mécanique suivie d’une neutralisation au triéthanolamine TEA. La taille des particules de la nanosuspension et de l’hydrogel a été déterminée par diffusion dynamique de la lumière (DLS). Une méthode analytique de chromatographie liquide à haute performance (HPLC) munie d’un détecteur évaporatif (ELSD) a été développée et validée pour évaluer la teneur de docosanol dans les préparations liquides, dans les différentes nanosuspensions et dans les hydrogels de docosanol. L’état de cristallinité des nanocristaux dans la nanosuspension et dans l’hydrogel a été étudié par calorimétrie différentielle à balayage. La morphologie de la nanosuspension et de l’hydrogel de docosanol a été examinée par microscopie électronique à balayage (MEB). Les propriétés rhéologiques et de stabilité physique à différentes températures ont été aussi étudiées pour la formulation semi-solide (hydrogel). De même, la libération in vitro du docosanol contenu dans l’hydrogel et dans le produit commercial Abreva® a été étudiée à travers deux membranes de polycarbonates de taille de pores 400 et 800 nm. Dans le cas de nanosuspensions, des cristaux de docosanol de taille nanométrique ont été produits avec succès par broyage humide. Les nanoparticules de tailles variant de 197 nm à 312 nm ont été produites pour des pourcentages différents en docosanol, en polymère HPC et en surfactant SDS. Après lyophilisation, une augmentation de la taille dépendant de la composition de la formulation a été observée tout en restant dans la gamme nanométrique pour la totalité presque des formulations étudiées. Dans le cas des hydrogels examinés, la taille moyenne des particules de docosanol est maintenue dans la gamme nanométrique avant et après lyophilisation. L’analyse thermique des mélanges physiques, des nanosuspensions et des hydrogels de docosanol a révélé la conservation de l’état de cristallinité des nanocristaux de docosanol après broyage et aussi après gélification. L’examen par microscopie électronique à balayage (MEB) a montré que la nanosuspension et l’hydrogel ont tous deux une morphologie régulière et les nanoparticules ont une forme sphérique. De plus les nanoparticules de la nanosuspension ont presque la même taille inférieure à 300 nm en accord avec le résultat obtenu par diffusion dynamique de la lumière (DLS). Les nanoparticules de l’hydrogel ont une légère augmentation de taille par rapport à celle de la nanosuspension, ce qui est en accord avec les mesures de DLS. D’après les mesures rhéologiques, l’hydrogel de docosanol a un comportement pseudoplastique et un faible degré de thixotropie. L’étude de stabilité physique a montré que les formulations d’hydrogel sont stables à basse température (5°C) et à température ambiante (21°C) pendant une période d’incubation de 13 semaines et instable au-delà de 30°C après deux semaines. La méthode HPLC-ELSD a révélé des teneurs en docosanol comprises entre 90% et 110% dans le cas des nanosuspensions et aux alentours de 100% dans le cas de l’hydrogel. L’essai de diffusion in vitro a montré qu’il y a diffusion de docosanol de l’hydrogel à travers les membranes de polycarbonates, qui est plus marquée pour celle de pore 800 nm, tandis que celui du produit commercial Abreva® ne diffuse pas. Le broyage humide est une technique bien adaptée pour la préparation des nanosuspensions docosanol. Ces nanosuspensions peuvent être utilisée comme base pour la préparation de l’hydrogel de docosanol nanoformulé.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
EVAPORATIVE LIGHT-SCATTERING DETECTOR FOR ANALYSIS OF NATURAL PRODUCTS. The interest in the use of evaporative light scattering detector (ELSD) for the analysis of different classes of natural products has grown over the years. This is because this detector has become an excellent alternative compared to other types of detectors, such as the refractive index detector and the ultraviolet (UV) detector. This review describes the basic principles of ELSD functioning and discusses the advantages and disadvantages in using an ELSD for the analysis of organic compounds. Additionally, an overview, covering the last 23 years, of ELSD applications in natural products analysis (saponins, terpenes, carbohydrates, glycosides, alkaloids, steroids, flavonoids, peptides, polyketides, coumarins and iridoids) is presented and discussed.
Resumo:
The interest in the use of evaporative light scattering detector (ELSD) for the analysis of different classes of natural products has grown over the years. This is because this detector has become an excellent alternative compared to other types of detectors, such as the refractive index detector and the ultraviolet (UV) detector. This review describes the basic principles of ELSD functioning and discusses the advantages and disadvantages in using an ELSD for the analysis of organic compounds. Additionaly, an overview, covering the last 23 years, of ELSD applications in natural products analysis (saponins, terpenes, carbohydrates, glycosides, alkaloids, steroids, flavonoids, peptides, polyketides, coumarins and iridoids) is presented and discussed.
Resumo:
Phosphatidylethanol (PEth) is an abnormal phospholipid carrying two fatty acid chains. It is only formed in the presence of ethanol via the action of phospholipase D (PLD). Its use as a biomarker for alcohol consumption is currently under investigation. Previous methods for the analysis of PEth included high-performance liquid chromatography (HPLC) coupled to an evaporative light scattering detector (ELSD), which is unspecific for the different homologues--improved methods are now based on time of flight mass spectrometry (TOF-MS) and tandem mass spectrometry (MS/MS). The intention of this work was to identify as many homologues of PEth as possible. A screening procedure using multiple-reaction monitoring (MRM) for the identified homologues has subsequently been established. For our investigations, autopsy blood samples collected from heavy drinkers were used. Phosphatidylpropanol 16:0/18:1 (internal standard) was added to the blood samples prior to liquid-liquid extraction using borate buffer (pH 9), 2-propanol and n-hexane. After evaporation, the samples were redissolved in the mobile phase and injected into the LC-MS/MS system. Compounds were separated on a Luna Phenyl Hexyl column (50 mm x 2 mm, 3 microm) by gradient elution, using 2 mM ammonium acetate and methanol/acetone (95/5; v/v). A total of 48 homologues of PEth could be identified by using precursor ion and enhanced product ion scans (EPI).
Resumo:
Quantification of the lipid content in liposomal adjuvants for subunit vaccine formulation is of extreme importance, since this concentration impacts both efficacy and stability. In this paper, we outline a high performance liquid chromatography-evaporative light scattering detector (HPLC-ELSD) method that allows for the rapid and simultaneous quantification of lipid concentrations within liposomal systems prepared by three liposomal manufacturing techniques (lipid film hydration, high shear mixing, and microfluidics). The ELSD system was used to quantify four lipids: 1,2-dimyristoyl-sn-glycero-3-phosphocholine (DMPC), cholesterol, dimethyldioctadecylammonium (DDA) bromide, and D-(+)-trehalose 6,6′-dibehenate (TDB). The developed method offers rapidity, high sensitivity, direct linearity, and a good consistency on the responses (R2 > 0.993 for the four lipids tested). The corresponding limit of detection (LOD) and limit of quantification (LOQ) were 0.11 and 0.36 mg/mL (DMPC), 0.02 and 0.80 mg/mL (cholesterol), 0.06 and 0.20 mg/mL (DDA), and 0.05 and 0.16 mg/mL (TDB), respectively. HPLC-ELSD was shown to be a rapid and effective method for the quantification of lipids within liposome formulations without the need for lipid extraction processes.