999 resultados para ELECTROMYOGRAPHIC EVALUATION


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this work was to investigate the neuromuscular changes associated with the orthodontic post-treatment using surface electromyography. One hundred (100) young, healthy adults without signs and symptoms of temporomandibular dysfunction (TMD) were divided into two groups: 60 subjects who were undergoing orthodontic intervention (Ortho Group) and 40 subjects who had no orthodontic intervention (Control Group), aged 18-25 years. EMG activity of masseter and temporalis anterior muscle was recorded during two different tests: 1. maximum voluntary clench (MVC) with cotton rolls; and 2. MVC in intercuspal position. In all subjects, both tests were performed with symmetric muscular patterns (more than 85%) and with insignificant latero-deviating of the mandible (lower than 10%). There are no statistically significant differences between the subjects of both groups evaluated. Both groups showed medium index values calculated according to the normal standards established previously.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

CAUDA equina syndrome (CES) has long been recognized as a rare complication of spinal anesthesia.(1) CES has been described after administration of spinal anesthetics with lidocaine(2) and bupivacaine.(3) In 1991,(4) CES was reported after continuous spinal anesthesia with 1% tetracaine. In 1980, at our university hospital, six adult female patients underwent perineal gynecologic surgery using a spinal anesthetic of 2 ml tetracaine, 1.2%, in 10% glucose. The concentration of the injected tetracaine was unknown by the anesthetists. In all cases, lumbar puncture was performed at the L3-L4 interspace with a disposable spinal needle while the patients were in the sitting position. CES was first diagnosed 72 h or later postoperatively; previous diagnosis was not possible because patients had an indwelling urethral catheter. The diagnosis of CES was confirmed in all patients. During the past year, after institutional approval and informed consent, clinical, magnetic resonance imaging, electromyographic examinations, and conduction studies were performed in three of the above patients. Examinations were not possible on the other three patients because one had recently died, another could not be located, and the third refused to participate. T1 and T2 magnetic resonance image readings were obtained with Gadolinium contrast from a 0.5 Tesla General Electric apparatus (General Electric, Tokyo, Japan). Bilateral sensory and motor conduction studies of the sciatic nerve branches were obtained using a two-channel Nihon-Kohden Neuropack 2 (Nihom-Kohden Corporation, Tokyo, Japan). Electromyography was performed in accordance with conventional techniques.(5,6)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The rectus femoris was analysed in 10 volunteers during knee flexion and extension with the feet in normal, plantar flexion and dorsal flexion positions. Hewlett-Packard surface electrodes, an electromyographic signal amplifier, a computer equipped with an A/D conversion plaque (Model CAD 10/26), software specially designed to record and analyse the signals, Horizontal Leg Press, and electrogoniometers were used. The rectus femoris muscle showed strong potentials at the beginning of knee extension. In the simultaneous bendings of the knee and hip the activity was strong toward the end of the movement. The rectus femoris showed a similar activity both in the upper and lower platforms. As for foot positions, the rectus femoris showed the smallest potentials with the foot in plantar flexion and the largest ones with the foot in dorsal flexion.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: The aim of this study was to assess the existence of myofunctional alterations before and after first premolar extraction in Class II/1 malocclusion patients that could endanger the long-term dental arch stability. Materials and Methods: The study was performed by means of morphological, functional and electromyographic analyses in 17 Class II/1 malocclusion patients (group T) and 17 Class I malocclusion patients (group C), both groups with 12-30-year age range (mean age: 20.93 ± 4.94 years). Results: Data analyzed statistically by Student's t-test showed a significant decrease in the maxillary and mandibular dental arch perimeters after orthodontic treatment (p<0.05). The Kruskal-Wallis test analyzed data from tongue posture at rest and during swallowing, not showing significant differences after treatment (groups Tb and Ta) (p>0.05). However, group T differed significantly from group C (p<0.05). The electromyographic data showed that the anterior right and left suprahyoid muscles acted synergistically in both groups, while having a lower myoelectric activity in group T during swallowing. Conclusions: Myofunctional alterations observed after the orthodontic treatment in Class II/1 malocclusion seemed to jeopardize the long-term orthodontic stability, making recurrence possible. Further research should be conducted to compare electromyographic data before and after orthodontic treatment in order to corroborate the results of the present investigation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to assess the electrical activity of the masseter and anterior temporal muscles in patients with severe bone resorption, with complete dentures worn for over ten years, and five months after having new dentures put in place. The RDC questionnaire was applied to twelve asymptomatic patients, before and five months after new dentures were put in place. The electrical activity recordings were made in the mandibular position at rest, and during maximum tooth clenching. The electrical activity of the masseter and anterior temporal muscles in the position at rest presented no statistically significant difference after five months of wearing the new complete dentures. Electrical activity during tooth clenching exhibited a statistically significant reduction only in the right temporal muscle. A period longer than five months of wearing the new complete dentures is required for adaptation and the acquisition of functional capacity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present study aimed at analyzing and comparing longitudinally the EMG (electromyographic activity) of the superior orbicularis oris muscle according to the breathing mode. The sample, 38 adolescents with Angle Class II Division 1 malocclusion with predominantly nose (PNB) or mouth (PMB) breathing, was evaluated at two different periods, with a two-year interval between them. For that purpose, a 16-channel electromyography machine was employed, which was properly calibrated in a PC equipped with an analogue-digital converter, with utilization of surface, passive and bipolar electrodes. The RMS data (root mean square) were collected at rest and in 12 movements and normalized according to time and amplitude, by the peak value of EMG, in order to allow comparisons between subjects and between periods. Comparison of the muscle function of PNB and PMB subjects at period 1 (P1), period 2 (P2) and the variation between periods (Δ) did not reveal statistically significant differences between groups (p < 0.05). However, longitudinal evaluation of the muscle function in PNB and PMB subjects demonstrated different evolutions in the percentage of required EMG for accomplishment of the movements investigated. It was possible to conclude that there are differences in the percentage of electric activity of the upper lip with the growth of the subjects according to the breathing mode.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This is the first study performed with an interocclusal splint with a vibrating device on patients with sleep bruxism. The purpose of the present study was to evaluate the effectiveness of the splint with vibrating device on patients who suffer from sleep bruxism through computerized electromyography (EMG) of the anterior temporal muscles. Eight male and female patients, ranging in age from 18 to 28 years, with evident signs and symptoms of bruxism were selected. The splint were made for the upper arch. The patients was treated with the interocclusal splint with a vibrating device, and submitted to EMG evaluations of the anterior temporal muscles on both sides. The evaluations were performed at the beginning of treatment and after 21 days of splint use. Electromyography was performed in an isometric contractions measuring of the temporal muscles. The following results obtained revealed that: when closing the mandible (isometric contraction), the anterior temporal muscles had an expressive reduction in electromyographic activity (p. < 0.10), so this splints were considered effective for patients who suffer from sleep bruxism. © 2009 Springer-Verlag.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this study was to investigate the immediate effects of laser therapy on neuromuscular performance in healthy subjects after a muscle fatigue. This is a clinical trial, controlled, randomized, blinded, attended by 80 volunteers of both genders, healthy, with ages between 18 to 28 years. Initially the volunteers performed an initial evaluation (EV1) using electromyography in the biceps muscle, associated with assessment in isokinetic dynamometry with 5 concentric contractions (60 °/s) for elbow flexion. The subjects were randomly allocated into 4 groups: G1 (control, n = 20), G2 (placebo, n = 20), G3 (pre-fatigue laser, n = 20), and G4 (post fatigue laser, n = 20). The muscular fatigue protocol had 30 concentric isokinetic contractions (120 °/s). We used a 808 nm laser, power of 100 mW, applied at the belly of the biceps muscle. After the speeches the volunteers performed a final evaluation (EV2). Test was applied to two-way ANOVA with post hoc Turkey, with a significance level of 5%. There was no significant difference in electromyographic evaluation. In dynamometric evaluation showed a drop in peak torque, peak torque normalized to body weight (p <0.001) and average power (p <0, 05) between the initial and final evaluations in control. Among the groups there was a significant difference between the control and the other groups in relation to peak torque (p <0.05), peak torque to body weight (p <0.001) and average power (p <0.05). Therefore, the low intensity laser therapy does not alter the immediate neuromuscular performance after fatigue

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this study was to evaluate the electromyographic and histopathological changes in skeletal muscles of dogs naturally infected by L. infantum. Twenty five mixed breed adult dogs with parasitological, molecular and serological diagnosis were selected. The evaluated muscles were: triceps brachial, extensor carpi radialis, biceps femoris and gastrocnemius. One dog had locomotor clinical signs with hind limbs paresis associated with severe muscle atrophy. Twenty-three (92%) had some type of muscular change, and in 22 (88%) such changes were directly identified by electromyography. Even without any clinical signs of the disease, 10 (40%) dogs had electromyographic and histopathological changes. Leishmania antigens were detected in muscles of four (16%) dogs. The electromyographic evaluation indicated the occurrence of chronic polymyositis in 13 (52%) dogs, the presence of both acute and chronic muscle inflammation four (16%), acute myopathy in two (8%) and absence of electromyographic abnormalities in three (12%) dogs. The most frequently observed histopathological changes were degeneration and necrosis of myofibers and inflammatory infiltration observed in 12 (48%) dogs. Other changes were decreased diameter of muscle fibers in 15 (60%) and peri or endomysial fibrosis in 14 (56%) animals. The changes observed in the present study showed that even in the absence of clinical signs, most dogs infected by Leishmania infantum have chronic polymyositis.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The Lucia jig is a technique that promotes neuromuscular reprogramming of the masticatory system and allows the stabilization of the mandible without the interference of dental contacts, maintaining the mandible position in harmonic condition with the musculature in normal subjects or in patients with temporomandibular dysfunction (TMD). This study aimed to electromyographically analyze the activity (RMS) of the masseter and temporal muscles in normal subjects (control group) during the use of an anterior programming device, the Lucia jig, in place for 0, 5, 10, 20 and 30 minutes to demonstrate its effect on the stomatognathic system. Forty-two healthy dentate individuals (aged 21 to 40 years) with normal occlusion and without parafunctional habits or ternporomandibular dysfunction (RDC/TMD) were evaluated on the basis of the electromyographic activity of the masseter and temporal muscles before placement of a neuromuscular re-programming device, the Lucia jig, on the upper central incisors. There were no statistically significant differences (p < 0.05) in the electromyographic activity of the masticatory muscles in the different time periods. The Lucia jig changed the electromyographic activity by promoting a neuromuscular reprogramming. In most of the time periods, it decreased the activation of the masticatory muscles, showing that this device has wide applicability in dentistry. The use of a Lucia jig over 0, 5, 10, 15, 20 and 30 minutes did not promote any statistically significant increase in muscle activity despite differences in the data, thus showing that this intra-oral device can be used in dentistry.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The purpose of this study was to assess the effect of low level laser therapy on subjects with intra-articular temporomandibular disorders (IA-TMD), and to quantify and compare severity of signs and symptoms before, during, and after the laser applications. The sample consisted of 45 subjects randomly divided into three groups (G) of 15 subjects each: G-I: 15 individuals with IA-TMD submitted to an energy dose of 52.5 J/cm(2); G-II: dose of 105.0 J/cm(2); and G-III: placebo group (0 J/cm(2)). In all groups, the applications were performed on condylar points on the masseter and anterior temporalis muscles. Two weekly sessions were held for five weeks, totaling 10 applications. The assessed variables were: mandibular movements and painful symptoms evoked by muscle palpation. These variables were measured before starting the study, then immediately after the first, fifth, and tenth laser application, and finally, 32 days after completing the applications. The results showed that there were statistically significant differences for G-I and G-II at the level of 1% between the doses, as well as between assessments. Therefore, it was concluded that the use of low level laser increased the mean mandibular range of motion and reduced painful symptoms in the groups that received effective treatment, which did not occur in the placebo group.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The detection of physiological signals from the motor system (electromyographic signals) is being utilized in the practice clinic to guide the therapist in a more precise and accurate diagnosis of motor disorders. In this context, the process of decomposition of EMG (electromyographic) signals that includes the identification and classification of MUAP (Motor Unit Action Potential) of a EMG signal, is very important to help the therapist in the evaluation of motor disorders. The EMG decomposition is a complex task due to EMG features depend on the electrode type (needle or surface), its placement related to the muscle, the contraction level and the health of the Neuromuscular System. To date, the majority of researches on EMG decomposition utilize EMG signals acquired by needle electrodes, due to their advantages in processing this type of signal. However, relatively few researches have been conducted using surface EMG signals. Thus, this article aims to contribute to the clinical practice by presenting a technique that permit the decomposition of surface EMG signal via the use of Hidden Markov Models. This process is supported by the use of differential evolution and spectral clustering techniques. The developed system presented coherent results in: (1) identification of the number of Motor Units actives in the EMG signal; (2) presentation of the morphological patterns of MUAPs in the EMG signal; (3) identification of the firing sequence of the Motor Units. The model proposed in this work is an advance in the research area of decomposition of surface EMG signals.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The pattern of tonic and phasic components in an EMG signal reflects the underlying behaviour of the central nervous system (CNS) in controlling the musculature. One avenue for gaining a better understanding of this behaviour is to seek a quantitative characterisation of these phasic and tonic components. We propose that these signal characteristics can range between unvarying, tonic and intermittent, phasic activation through a continuum of EMG amplitude modulation. In this paper, we present two new algorithms for quantifying amplitude modulation: a linear-envelope approach, and a mathematical morphology approach. In addition we present an algorithm for synthesising EMG signals with known amplitude modulation. The efficacy of the synthesis algorithm is demonstrated using real EMG data. We present an evaluation and comparison of the two algorithms for quantifying amplitude modulation based on synthetic data generated by the proposed synthesis algorithm. The results demonstrate that the EMG synthesis parameters represent 91.9% and 96.2% of the variance of linear-envelopes extracted from lumbo-pelvic muscle EMG signals collected from subjects performing a repetitive-movement task. This depended, however, on the muscle and movement-speed considered (F=4.02, p<0.001). Coefficients of determination between input and output amplitude modulation variables were used to quantify the accuracy of the linear-envelope and morphological signal processing algorithms. The linear-envelope algorithm exhibited higher coefficients of determination than the most accurate morphological approach (and hence greater accuracy, T=8.16, p<0.001). Similarly, the standard deviation of the coefficients of determination was 1.691 times smaller (p<0.001). This signal processing algorithm represents a novel tool for the quantification of amplitude modulation in continuous EMG signals and can be used in the study of CNS motor control of the musculature in repetitive-movement tasks.