993 resultados para ELECTRODE-REACTION


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Current-potential relationships are derived for porous electrode systems following a homogeneous model and whenadsorbed intermediates participate in the electrode reaction. Limiting Tafel slopes were deduced and compared with thecorresponding behavior on planar electrode systems. The theoretical results showed doubling of Tafel slopes when theslow-step is a charge-transfer reaction and a nonlogarithmic current-voltage behavior when the slow-step is a chemical reaction.Comparison of the experimental results with theory for the case of oxygen reduction on carbon surfaces in alkalinemedia indicates that a slow chemical reaction following the initial charge-transfer reaction to be the likely rate-controllingstep. Theoretical relationships are utilized to determine the exchange current density and the surface coverage by the adsorbedintermediates during the course of oxygen reduction from alkaline solutions on "carbon." Tafel slope measurementson planar and porous electrodes for the same reaction are suggested as one of the diagnostic criteria for elucidatingthe mechanistic pathways of electrochemical reactions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Silver nanoparticles-anchored reduced graphene oxide (Ag-RGO) is prepared by simultaneous reduction of graphene oxide and Ag+ ions in an aqueous medium by ethylene glycol as the reducing agent. Ag particles of average size of 4.7 nm were uniformly distributed on the RGO sheets. Oxygen reduction reaction (ORR) is studied on Ag-RGO catalyst in both aqueous and non-aqueous electrolytes by using cyclic voltammetry and rotating disk electrode techniques. As the interest in non-aqueous electrolyte is to study the catalytic performance of Ag-RGO for rechargeable Li-O-2 cells, these cells are assembled and characterized. Li-O-2 cells with Ag-RGO as the oxygen electrode catalyst are subjected to charge-discharge cycling at several current densities. A discharge capacity of 11 950 mA h g(-1) (11.29 mA h cm(-2)) is obtained initially at low current density. Although there is a decrease in the capacity on repeated discharge-charge cycling initially, a stable capacity is observed for about 30 cycles. The results indicate that Ag-RGO is a suitable catalyst for rechargeable Li-O-2 cells.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

It is shown that the effect of adsorption of inert molecules on electrode reaction rates is completely accounted for, by introducing into the rate equation, adsorption-induced changes in both the effective electrode area as well as in the electrostatic potential at the reaction site with an additional term for the noncoulombic interaction between the reactant and the adsorbate. The electrostatic potential at the reaction site due to the adsorbed layer is calculated using a model of discretely-distributed molecules in parallel orientation when adsorbed on the electrode with an allowance for thermal agitation. The resulting expression, which is valid for the limiting case of low coverages, is used to predict the types of molecular surfactants that are most likely to be useful for acceleration and inhibition of electrode reactions.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The anodic voltammetric behavior of ethambutol in the presence of various electrolytes was studied by direct-current voltammetry, differential-pluse voltammetry and cyclic voltammetry at a glassy carbon electrode. In a medium of 0.039 mol/L Na2HPO4, an oxidative peak of ethambutol was obtained. The peak potential is at about 1.04 V( vs. Ag/AgCl). The height of the peak is linearly increased with the concentration of ethambutol over the range of 3 mg/Lsimilar to1000 mg/L. The method has been used for the direct determination of ethambutol in tablets. The average recovery of ethambutol in urine samples is 84.7%. Experimental results proved that the electrode reaction was diffusion controlled and irreversible.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The anodic voltammetric behavior of ethacridine (EAD) in the presence of various electrolytes was studied by using linear potential sweep voltammetry, differential-pulse voltammetry and cyclic voltammetry at a glassy carbon electrode. In the medium of 0.1 mol/L NaOH solution, an oxidative peak of ethaeridine was obtained. The peak potential is at about 0.40 V (vs. Ag/AgCl). The peak current is linearly increased with the concentration of ethaeridine over the range of 0.05 similar to 80 mg/L. The method has been used for the direct determination of ethacridine in injection. The relative standard deviation (n = 10) is 1.4% similar to 2.7%. The recoveries of ethacridine in urine samples are 89% similar to 95%. The mechanism of the electrode reaction was also discussed.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Heterogeneous electron transfer rate constants (k(s)) and diffusion coefficients (D) of the ferrocene and its derivatives. in a new synthetic comb polymer solvent, poly(dimethylsiloxane-g-monomethylether polyethylene glycol) (SCP), and several other polymer solvents were estimated by using microelectrodes. Also, the influence of various supporting electrolytes on k(s) and D of ferrocene was studied. It was shown that k(s) and D of ferrocene decreased with increasing anionic size of the supporting electrolyte, but k(s) tended to increase with increasing radius of the solvated cation. Also, the cationic size of the supporting electrolytes had little effects on D. The values of k(s) and D for the ferrocene derivatives in the polymer solvents were in sharp contrast to those in monomeric solvents. Thus. the k(s) values were proportional to D in the polymer solvents. which indicates that solvent dynamics control of the electrode reaction. The values of k(s) and D of ferrocene in SCP were larger than those in other polymer solvents indicating that SCP is a good polymer solvent. (C) 2000 Elsevier Science B.V. All rights reserved.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The anodic voltammetric behavior of inosine (I) was investigated by linar-sweep voltammetry, differential-pulse voltammetry and cyclic voltammetry at a glassy carbon electrode. In a medium of 0.1 mol/L N2HPO4, inosine showed a well defined anodic peak. The peak potential was about 1.42 V (vs. Ag/AgCl). A linear relationship held between the peak current and the concentration of inosine in the rang of 5 x 10(-4) similar to 8 x 10(-2) g/L. The peak potential decreased with the decrease of the acidity of the solution. The four anodic peaks of inosine with hypoxanthine, xanthine and uric acid were obtained. Their peak potentials were about at 1.42, 1.07, 0.72 and 0.26 Vt vs. Ag/AgCl). The method has been used for the direct determination of inosine in injections. Recoveries of inosine in urine samples were about 85%. Experimental result proved that the electrode reaction was diffusion-controlled and irreversible.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The anodic voltammetric behavior of dipyridamole (DPM) in the presence of various electrolytes was studetd by direct-current voltammetry, differential-pulse voltammetry and cyclic voltammetry at a glassy carbon electrode. In a medium of 0.01 mol/L HCl, an oxidative peak of dipyridamole was obtained. The peak potential is at about 0.62 V(vs.Ag/AgCl). The peak current is linearly increased with the concentration of dipyridamole over the range of 0.05 similar to 10 mg/L. The method has been used for the direct determination of dipyridamole in tablets. The recoveries of dipyridamole in urine samples are 89%. Experimental results proved that the electrode reaction was diffustion controlled and irreversible.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The anodic voltammetric behavior of anaesthetic tetracine and its application were studied. In 0.1 mol/L HClO4 solution, the potential of anodic peak for tetracine is 1.04 V(vs. Ag/AgCl) at a glassy carbon electrode. A linear relationship between the peak height and the concentration of tetracine in the range of 5 x 10(-4) similar to 1 x 10(-1) g/L was obtained. The peak current decreases with the decreasing acidity of the solution. the mehtod has been used for the direct determination of tetracine in injections. The average recoveries of tetracine in urine samples were 98.5%. The mechanism of the electrode reaction was also discussed.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The voltammetric behaviour of acetophenetidin(A(1)) aminopyrine(A(2)) acetaminophenol(A(3)) and aminophenol(A(4)) was investigated by linear-sweep, differential-pulse, cyclic voltammetry at a glassy carbon electrode. In a medium of 0.1 mol/L NaOH solution, 4 high sensitivity and resolution anodic peaks were obtained. Their peak potentials are about at 0.68 V, 0.51, 0.22 and - 0.06 V( vs. Ag/AgCl). They can be used for direct determination of A(1), A(2),A(3),A(4) in samples respectively. The method is simple and rapid. The mechanism of the electrode reaction was discussed.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The isopolymolybdic anion-polyaniline film modified carbon fiber (CF) microelectrode with high stability and electroactivity in aqueous acid solution has been successfully prepared by cycling the potential between -0.15 V and +0.85 V vs. sce at 100 mV s-1 or applying constant potential (+0.85 V) for electropolymerization in a 0.5 M H2SO4 solution containing 5.0 x 10(-2) M aniline and 5.0 x 10(-3) M H4Mo8O26. The electrochemical behaviour of the isopolymolybdic anion entrapped in the polyaniline film is strongly influenced by the sweep-potential range besides the acidity of electrolyte solution. In some acidic electrolyte solution (eg 0.5 M H2SO4), the change of the sweep-potential range causes the structure alternation of the isopolymolybdic anion and resulting in a new electrode process. The cyclic voltammogram of Mo8O264- in 0.5 M H2SO4 solution exhibits three two-electron reversible waves between +0.70 and -0.20 V. However, when the potential sweeps to the lower-limit of -0.3 V, where the fourth four-electron cathodic wave appears, the redoxidation process of the reduction product of Mo8O264- becomes relatively complicated. The 10-electron reduction product seems to change into other isopolyanion (this unknown structure isopolyanions are simply called [Mo-O]), which can be reoxidized to Mo8O264- by five successive two-electron oxidation steps from -0.30 to +0.70 V. However, when the lower-limit of the cycling potential is maintained at -0.30 V and the upper-limit reduces to +0.40 V from +0.70 V, the [Mo-O] in the film exhibits four two-electron reversible waves. We have presented a novel explanation about its electrode reaction mechanism on the basis of our experimental results.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Voltammetry is reported for chlorine, Cl-2, dissolved in various room temperature ionic liquids using platinum microdisk electrodes. A single reductive voltammetric wave is seen and attributed to the two-electron reduction of chlorine to chloride. Studies of the effect of voltage scan rate reveal uniquely unusual behavior in which the magnitude of the currents decrease with increasing scan rates. A model for this is proposed and shown to indicate the presence of strongly adsorbed species in the electrode reaction mechanism, most likely chlorine atoms, Cl*((ads)).

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Pyrazinamide (Pyrazinecarboxamide-PZA) is a drug that is used to treatment tuberculosis. In the present work, the voltammetric behavior of PZA was studied using a screen-printed modified electrode (SPCE). The modified electrode was constructed using poly-histidine films, and it showed an electrocatalytic effect, thus promoting a decrease in PZA reduction potential and improving the voltammetric response. Cyclic voltammetry and electrochemical impedance spectroscopy techniques have been employed in order to elucidate of the electrodic reaction. The results allowed the proposal that in the PZA reduction, a further chemical reaction occurs that corresponds to a second-order process which is subsequent to the electrode reaction. In addition, a sensitive voltammetric method was developed, and it was successfully applied for PZA determination in human urine samples. The best response was found using SPCE modified with poly-histidine prepared by histidine monomer electropolymerization (SPCE/EPH). The electroanalytical performance of the SPCE/EPH was investigated by linear sweep (LSV), differential pulse (DPV), and square wave voltammetry (SWV). A linear relationship between peak current and PZA concentrations was obtained from 9.0 × 10-7 to 1.0 × 10-4 mol L-1 by using DPV. The limit of detection at 5.7 × 10 -7 mol L-1 was estimated, and a relative standard deviation of the 5.0 × 10-6 mol L-1 of PZA of 10 measurement was 3.7%. © 2012 Elsevier B.V. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Doss and Agarwal 1 discovered the "redoxokinetic effect" which is now familiarly known as faradaic rectification. Subsequently, the theory and applications of faradaic rectification due to a single electrode reaction have been developed by several workers 2-5. The theory and application of faradaic rectification in the case of a corrosion cell sustaining mixed electrode reactions on a corroding metal was reported recently 6"7. This led to the development of a new electrochemical method of corrosion rate determination. It was shown that changes in the instantaneous corrosion rates of a metal are readily evaluated by faradaic rectification measurements at the corrosion potential of the metal in a given medium. The aim of the present work is to show that absolute values of instantaneous corrosion rates may also be obtained by the new method under certain conditions. The practical advantages that arise from this development are pointed out.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Results on the performance of a 25 cm(2) liquid-feed solid-polymer-electrolyte direct methanol fuel cell (SPE-DMFC), operating under near-ambient conditions, are reported. The SPE-DMFC can yield a maximum power density of c. 200 mW cm(-2) at 90 C while operating with 1 M aqueous methanol and oxygen under ambient pressure. While operating the SPE-DMFC under similar conditions with air, a maximum power density of ca. 100 mW cm(-2) is achieved. Analysis of the electrode reaction kinetics parameters on the methanol electrode suggests that the reaction mechanism for methanol oxidation remains invariant with temperature. Durability data on the SPE-DMFC at an operational current density of 100 mA cm(-2) have also been obtained.