972 resultados para EEG neonatal
Resumo:
Introduction Seizures are harmful to the neonatal brain; this compels many clinicians and researchers to persevere further in optimizing every aspects of managing neonatal seizures. Aims To delineate the seizure profile between non-cooled versus cooled neonates with hypoxic-ischaemic encephalopathy (HIE), in neonates with stroke, the response of seizure burden to phenobarbitone and to quantify the degree of electroclinical dissociation (ECD) of seizures. Methods The multichannel video-EEG was used in this research study as the gold standard to detect seizures, allowing accurate quantification of seizure burden to be ascertained in term neonates. The entire EEG recording for each neonate was independently reviewed by at least 1 experienced neurophysiologist. Data were expressed in medians and interquartile ranges. Linear mixed models results were presented as mean (95% confidence interval); p values <0.05 were deemed as significant. Results Seizure burden in cooled neonates was lower than in non-cooled neonates [60(39-224) vs 203(141-406) minutes; p=0.027]. Seizure burden was reduced in cooled neonates with moderate HIE [49(26-89) vs 162(97-262) minutes; p=0.020] when compared with severe HIE. In neonates with stroke, the background pattern showed suppression over the infarcted side and seizures demonstrated a characteristic pattern. Compared with 10 mg/kg, phenobarbitone doses at 20 mg/kg reduced seizure burden (p=0.004). Seizure burden was reduced within 1 hour of phenobarbitone administration [mean (95% confidence interval): -14(-20 to -8) minutes/hour; p<0.001], but seizures returned to pre-treatment levels within 4 hours (p=0.064). The ECD index in cooled, non-cooled neonates with HIE, stroke and in neonates with other diagnoses were 88%, 94%, 64% and 75% respectively. Conclusions Further research exploring the treatment effects on seizure burden in the neonatal brain is required. A change to our current treatment strategy is warranted as we continue to strive for more effective seizure control, anchored with use of the multichannel EEG as the surveillance tool.
Resumo:
Video-polygraphic-EEG studies were performed in the first 24 life-hours of 26 healthy full-term newborns without perinatal injuries. The neurological examination and cranial ultrasonography were normal. The newborns were divided into two groups: one, with full-term appropriate - birth weight 11 newborns (control group ) and the other with full-term low-birth weight 15 newborns. Thirteen newborns of the second group had video-polygraphic-EEG study abnormalities. The most frequent abnormalities were found in 11 cases, as far as sleep architecture is concerned. Also, when compared with the control group, 8 cases of an excessive amount of startles and 2 cases of low behavior activities were found. The results demonstrate the usefulness of video-polygraphic-EEG study in the full-term newborns with intra-uterine growth retard. This examination was sensitive to detect behavior, sleep architecture and EEG standard differences in the low birth-weight newborns as to the control group.
Resumo:
Analisamos o exame video-polissonográfico de 26 recém-nascidos de termo (RNT) com 24 horas de vida. Os RN tinham exame neurológico e ultrassonográfico cerebral normais e apresentaram período perinatal isento de complicações. Foram subdivididos em dois grupos, um controle constituído de 11 RNT com peso adequado para a idade gestacional; e um grupo de 15 RN com peso abaixo do esperado para o termo (RNT-PIG). do segundo grupo, 13 RN apresentaram algum tipo de alteração ao exame video-polissonográfico. As alterações mais frequentes foram na arquitetura do sono, 11 casos, e no comportamento, em que oito RN apresentaram número excessivo de sobressaltos (startle) em relação ao grupo controle e dois RN uma atividade motora reduzida. Os resultados deste estudo demonstram a utilidade da video-polissonografia quando aplicada a RNT-PIG. O exame mostrou-se sensível em detectar diferenças no comportamento, arquitetura do sono e padrão eletrencefalográfico dos RNT-PIG quando comparados ao grupo controle.
Resumo:
Objective: Phenobarbital increases electroclinical uncoupling and our preliminary observations suggest it may also affect electrographic seizure morphology. This may alter the performance of a novel seizure detection algorithm (SDA) developed by our group. The objectives of this study were to compare the morphology of seizures before and after phenobarbital administration in neonates and to determine the effect of any changes on automated seizure detection rates. Methods: The EEGs of 18 term neonates with seizures both pre- and post-phenobarbital (524 seizures) administration were studied. Ten features of seizures were manually quantified and summary measures for each neonate were statistically compared between pre- and post-phenobarbital seizures. SDA seizure detection rates were also compared. Results: Post-phenobarbital seizures showed significantly lower amplitude (p < 0.001) and involved fewer EEG channels at the peak of seizure (p < 0.05). No other features or SDA detection rates showed a statistical difference. Conclusion: These findings show that phenobarbital reduces both the amplitude and propagation of seizures which may help to explain electroclinical uncoupling of seizures. The seizure detection rate of the algorithm was unaffected by these changes. Significance: The results suggest that users should not need to adjust the SDA sensitivity threshold after phenobarbital administration.
Resumo:
The detection of seizure in the newborn is a critical aspect of neurological research. Current automatic detection techniques are difficult to assess due to the problems associated with acquiring and labelling newborn electroencephalogram (EEG) data. A realistic model for newborn EEG would allow confident development, assessment and comparison of these detection techniques. This paper presents a model for newborn EEG that accounts for its self-similar and non-stationary nature. The model consists of background and seizure sub-models. The newborn EEG background model is based on the short-time power spectrum with a time-varying power law. The relationship between the fractal dimension and the power law of a power spectrum is utilized for accurate estimation of the short-time power law exponent. The newborn EEG seizure model is based on a well-known time-frequency signal model. This model addresses all significant time-frequency characteristics of newborn EEG seizure which include; multiple components or harmonics, piecewise linear instantaneous frequency laws and harmonic amplitude modulation. Estimates of the parameters of both models are shown to be random and are modelled using the data from a total of 500 background epochs and 204 seizure epochs. The newborn EEG background and seizure models are validated against real newborn EEG data using the correlation coefficient. The results show that the output of the proposed models has a higher correlation with real newborn EEG than currently accepted models (a 10% and 38% improvement for background and seizure models, respectively).
Resumo:
Multi-frequency bio-impedance has the potential to identify infants at risk of poor neurodevelopmental outcome following hypoxia by detecting cerebral edema. This study investigated the relationship between the severity of an hypoxic/ischemic episode, neurological outcome following the hypoxia and non-invasively measured cerebral bioelectrical impedance in piglets. One-day-old piglets were anaesthetised and ventilated. Hypoxia was induced by reducing the inspired oxygen concentration to 3-5%. Severe hypoxia was defined as hypoxia resulting in at least 30 min of low amplitude EEG (
Resumo:
The effects of comorbid depression and anxiety were compared to the effects of depression alone and anxiety alone on pregnancy mood states and biochemistry and on neonatal outcomes in a large multi-ethnic sample. At the prenatal period the comorbid and depressed groups had higher scores than the other groups on the depression measure. But, the comorbid group had higher anxiety, anger and daily hassles scores than the other groups, and they had lower dopamine levels. As compared to the non-depressed group, they also reported more sleep disturbances and relationship problems. The comorbid group also experienced a greater incidence of prematurity than the depressed, the high anxiety and the non-depressed groups. Although the comorbid and anxiety groups were lower birthweight than the non-depressed and depressed groups, the comorbid group did not differ from the depressed and anxiety groups on birth length. The neonates of the comorbid and depressed groups had higher cortisol and norepinephrine and lower dopamine and serotonin levels than the neonates of the anxiety and non-depressed groups as well as greater relative right frontal EEG. These data suggest that for some measures comorbidity of depression and anxiety is the worst condition (e.g., incidence of prematurity), while for others, comorbidity is no more impactful than depression alone.
Resumo:
In the present work, the role of oxygen, epinephrine and glucose supplementation in regulating neurotransmitter contents, adrenergic and glutamate receptor binding parameters in the cerebral cortex of experimental groups of neonatal rats were investigated. The study of neurotransmitters and their receptors in the cerebral cortex and the EEG pattern in the brain regions of neonatal rats were taken as index for brain damage due to hypoxia, oxygen and epinephrine. Real-Time PCR work was done to confirm the binding parameters. Second messenger, cyclic Adenosine Monophosphate (cAMP) was assayed to find the functional correlation of the receptors. Behavioural studies were carried out to confirm the biochemical and molecular studies. The efficient and timely supplementation of glucose plays a crucial role in correcting the molecular changes due to hypoxia, oxygen and epinephrine. The addictive neuronal damage effect due to oxygen and epinephrine treatment is another important observation. The corrective measures from the molecular study brought to practice will lead to maintain healthy intellectual capacity during the later developmental stages, which has immense clinical significance in neonatal care.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
OBJECTIVE In susceptibility-weighted imaging (SWI) in the normal brain, cortical veins appear hypointense due to paramagnetic properties of deoxy-hemoglobin. Global cerebral anoxia decreases cerebral oxygen metabolism, thereby increasing oxy-hemoglobin levels in cerebral veins. We hypothesized that a lower cerebral oxygen extraction fraction in comatose patients with non-neonatal hypoxic ischemic encephalopathy (IHE) produce a pattern of global rarefied or pseudo-diminished cortical veins due to higher oxy-hemoglobin. PURPOSE 1. To investigate the topographic relationship between susceptibility effects in cortical veins and related diffusion restrictions on diffusion-weighted imaging (DWI) in patients with IHE. 2. To relate imaging findings to patterns of altered resting activity on surface EEG. METHODS Twenty-three IHE patients underwent MRI. EEG patterns were used to classify the depth of coma. Regional vs. global susceptibility changes on SWI and patterns of DWI restrictions were compared with the depth of coma. RESULTS All patients exhibited areas of restricted cortical diffusion and SWI abnormalities. The dominant DWI restrictions encompassed widespread areas along the precuneus, frontal and parietal association cortices and basal ganglia. For SWI, nineteen patients had generalized bi-hemispherical patterns, the EEG patterns correlated with coma grades III to V. Four patients had focal decreases of deoxy-hemoglobin following DWI restrictions; associated with normal EEGs. CONCLUSION Focal patterns of diamagnetic effects on SWI according to relative decreases in deoxy-hemoglobin due to reduced metabolic demand are associated with normal EEG in IHE patients. Global patterns indicated increased depth of coma and widespread cortical damage. CLINICAL RELEVANCE The results indicate a potential diagnostic value of SWI in patients with IHE.
Resumo:
Our aim was to identify early predictors of poor neurodevelopmental outcome and of subsequent epilepsy in very early preterm and late preterm newborns with neonatal seizures.
Resumo:
BACKGROUND: Seizures are one of the most common symptoms of acute neurological disorders in newborns. This study aims at evaluating predictors of epilepsy in newborns with neonatal seizures. METHODS: we recruited consecutively eighty-five neonates with repeated neonatal video-EEG-confirmed seizures between Jan 1999 and Dec 2004. The relationship between clinical, EEG and ultrasound data in neonatal period and the development of post-neonatal epilepsy was investigated at 7 years of age. RESULTS: Fifteen patients (17.6%) developed post-neonatal epilepsy. Partial or no response to anticonvulsant therapy (OR 16.7, 95% CI: 1.8-155.8, p= .01; OR 47, 95% CI: 5.2-418.1, p<.01 respectively), severely abnormal cerebral ultrasound scan findings (OR: 5.4; 95% CI: 1.1-27.4; p<.04), severely abnormal EEG background activity (OR: 9.5; 95% CI: 1.6-54.2; p= .01) and the presence of status epilepticus (OR: 6.1; 95% CI: 1.8-20.3; p<.01) were found to be predictors of epilepsy. However, only the response to therapy seemed to be an independent predictor of post-neonatal epilepsy. CONCLUSION: Neonatal seizures seem to be related to post-neonatal epilepsy. Recurrent and prolonged neonatal seizures may act on an epileptogenic substrate, causing further damage, which is responsible for the subsequent clinical expression of epilepsy.
Resumo:
Background : Phenobarbital is the first-line choice for neonatal seizures treatment, despite a response rate of approximately 45%. Failure to respond to acute anticonvulsants is associated with poor neurodevelopmental outcome, but knowledge on predictors of refractoriness is limited. Objective : To quantify response rate to phenobarbital and to establish variables predictive of its lack of efficacy. Methods : We retrospectively evaluated newborns with electrographically confirmed neonatal seizures admitted between January 1999 and December 2012 to the neonatal intensive care unit of Parma University Hospital (Italy), excluding neonates with status epilepticus. Response was categorized as complete (cessation of clinical and electrographic seizures after phenobarbital administration), partial (reduction but not cessation of electrographic seizures with the first bolus, response to the second bolus), or absent (no response after the second bolus). Multivariate analysis was used to identify independent predictors of refractoriness. Results : Out of 91 newborns receiving phenobarbital, 57 (62.6%) responded completely, 15 (16.5%) partially, and 19 (20.9%) did not respond. Seizure type (p = 0.02), background electroencephalogram (EEG; p ≤ 0.005), and neurologic examination (p ≤ 0.005) correlated with response to phenobarbital. However, EEG (p ≤ 0.02) and seizure type (p ≤ 0.001) were the only independent predictors. Conclusion : Our results suggest a prominent role of neurophysiological variables (background EEG and electrographic-only seizure type) in predicting the absence of response to phenobarbital in high-risk newborns.
Resumo:
Brain injury due to lack of oxygen or impaired blood flow around the time of birth, may cause long term neurological dysfunction or death in severe cases. The treatments need to be initiated as soon as possible and tailored according to the nature of the injury to achieve best outcomes. The Electroencephalogram (EEG) currently provides the best insight into neurological activities. However, its interpretation presents formidable challenge for the neurophsiologists. Moreover, such expertise is not widely available particularly around the clock in a typical busy Neonatal Intensive Care Unit (NICU). Therefore, an automated computerized system for detecting and grading the severity of brain injuries could be of great help for medical staff to diagnose and then initiate on-time treatments. In this study, automated systems for detection of neonatal seizures and grading the severity of Hypoxic-Ischemic Encephalopathy (HIE) using EEG and Heart Rate (HR) signals are presented. It is well known that there is a lot of contextual and temporal information present in the EEG and HR signals if examined at longer time scale. The systems developed in the past, exploited this information either at very early stage of the system without any intelligent block or at very later stage where presence of such information is much reduced. This work has particularly focused on the development of a system that can incorporate the contextual information at the middle (classifier) level. This is achieved by using dynamic classifiers that are able to process the sequences of feature vectors rather than only one feature vector at a time.
Resumo:
Neonatal seizures are common in the neonatal intensive care unit. Clinicians treat these seizures with several anti-epileptic drugs (AEDs) to reduce seizures in a neonate. Current AEDs exhibit sub-optimal efficacy and several randomized control trials (RCT) of novel AEDs are planned. The aim of this study was to measure the influence of trial design on the required sample size of a RCT. We used seizure time courses from 41 term neonates with hypoxic ischaemic encephalopathy to build seizure treatment trial simulations. We used five outcome measures, three AED protocols, eight treatment delays from seizure onset (Td) and four levels of trial AED efficacy to simulate different RCTs. We performed power calculations for each RCT design and analysed the resultant sample size. We also assessed the rate of false positives, or placebo effect, in typical uncontrolled studies. We found that the false positive rate ranged from 5 to 85% of patients depending on RCT design. For controlled trials, the choice of outcome measure had the largest effect on sample size with median differences of 30.7 fold (IQR: 13.7–40.0) across a range of AED protocols, Td and trial AED efficacy (p<0.001). RCTs that compared the trial AED with positive controls required sample sizes with a median fold increase of 3.2 (IQR: 1.9–11.9; p<0.001). Delays in AED administration from seizure onset also increased the required sample size 2.1 fold (IQR: 1.7–2.9; p<0.001). Subgroup analysis showed that RCTs in neonates treated with hypothermia required a median fold increase in sample size of 2.6 (IQR: 2.4–3.0) compared to trials in normothermic neonates (p<0.001). These results show that RCT design has a profound influence on the required sample size. Trials that use a control group, appropriate outcome measure, and control for differences in Td between groups in analysis will be valid and minimise sample size.