904 resultados para Droplet spectrum
Resumo:
The three-stage low-pressure model steam turbine at the Institute of Thermal Turbomachinery and Machinery Laboratory (ITSM) was used to study the impact of three different steam inlet temperatures on the homogeneous condensation process and the resulting wetness topology. The droplet spectrum as well as the particle number concentration were measured in front of the last stage using an optical-pneumatic probe. At design load, condensation starts inside the stator of the second stage. A change in the steam inlet temperature is able to shift the location of condensation onset within the blade row up- or downstream and even into adjoining blade passages, which leads to significantly different local droplet sizes and wetness fractions due to different local expansion rates. The measured results are compared to steady three-dimensional computational fluid dynamics calculations. The predicted nucleation zones could be largely confirmed by the measurements. Although the trend of measured and calculated droplet size across the span is satisfactory, there are considerable differences between the measured and computed droplet spectrum and wetness fractions. © IMechE 2013 Reprints and permissions: sagepub.co.uk/ journalsPermissions.nav.
Resumo:
It was aimed to evaluate the spectrum and uniformity of droplets in function of sprayers, spraying volumes and rates of chemical insecticide on the mortality of Pseudoplusia includens in laboratory. The work was carried out at UNESP, Jaboticabal, SP, Brazil. The following treatments were applied over the caterpillars: two equipments (atomizer and hydraulic nozzle); two spray volumes (17 and 50 L ha(-1) for the atomizer and 50 and 100 L ha(-1) for the hydraulic nozzle); and two dosages of the insecticide endosulfan (0.5 and 1.0 L pc ha(-1)), in fully randomized plots, in a factorial scheme 2x2x2 and 1 untreated check. The caterpillars mortality was evaluated until the 6(th) day after the application of treatments. The spectrum of the droplets was evaluated in a particle size analyzer in real time determining the diameter and spectrum of droplets sprayed through the laser beam of the analyser. It was verified that the spray volume can be reduced by 17 L ha(-1) without losses on the P. includens control. The doses of 0.5 L pc ha(-1) (recommended for Anticarsia gemmatalis) did not satisfactorily control the caterpillar soybean looper. The atomizer produces droplets of higher uniformity (SPAN: 0.52) and lower percentage of droplets susceptible to drift (3.3%) compared to hydraulic nozzle (SPAN: 1.34 e % droplets <= 100 mu m: 15.2).
Resumo:
O sucesso de uma boa aplicação de produtos fitossanitários depende da sinergia entre fatores como tamanho de gota, tipo de ponta, pressão, volume e composição da calda e características do alvo. Assim, o objetivo deste trabalho foi avaliar o espectro de gotas produzidas por pontas de jato plano defletor (TT 11002) e jato plano defletor com indução de ar (TTI 11002), com diferentes adjuvantes adicionados à calda de pulverização, pela técnica de difração de raio laser. O experimento foi conduzido em delineamento inteiramente casualizado, com quatro repetições, em esquema fatorial 2 x 5, ou seja, duas pontas de aplicação (jato plano defletor e jato plano defletor com indução de ar) e cinco composições de calda (água e água mais quatro adjuvantes: fosfatidilcoline+ácido propiônico, éter poliglicólico de monilfenol, ésteres de ácidos graxos e nonil-fenol etoxilado+óxido de etileno). em ambiente controlado, avaliou-se o espectro de gotas, por meio de um analisador a laser de gotas em tempo real, na pressão de 276 kPa. O efeito dos adjuvantes no espectro de gotas mostrou-se dependente da ponta de pulverização empregada. A adição dos adjuvantes à calda não alterou o risco potencial de deriva, expresso pela porcentagem do volume em gotas com diâmetro inferior a 100 µm, porém o adjuvante fosfatidilcoline+ácido propiônico reduziu o diâmetro da mediana volumétrica das gotas produzidas pela ponta de jato plano defletor com indução de ar, em relação à avaliação feita somente com água.
Resumo:
This study evaluated the characteristics of spray produced by Yamaho nozzle tip'D'series. The droplet size of nozzle tips D3, D4, D5, D6 and D8 were evaluated at 703, 1.050, 1.406, 1.758, 2.110, 2.461 e 2.813 kPa pressures (100, 200, 250; 350, e 400 psi) by means of laser equipment, as well as the flow rate of nozzle tip at the pressures of 702, 1.125, 1.406, 1.828, 2.110, 2.532 e 2.813 kPa (100, 160, 200, 260,300; 360 e 400 psi) which were compared with values indicated by manufacturer. The droplet produced at all pressures presented a very fine spray, which in agriculture may promote losses by evaporation and drift. For all nozzle tips, except D8 in pressures 1.828, 2.532 e 2.813 kPa, the difference between the observed flow rate indicated by the manufacturer was higher than 5%. The paper demonstrates that the nozzle tip tested, in spite of not having uniform flow rate, may promote the contamination of spray operator and environment due to the droplet spectrum produced.
Resumo:
Pós-graduação em Agronomia (Agricultura) - FCA
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Pós-graduação em Agronomia (Proteção de Plantas) - FCA
Resumo:
Pós-graduação em Agronomia (Proteção de Plantas) - FCA
Resumo:
Pós-graduação em Agronomia (Energia na Agricultura) - FCA
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The present study aimed to evaluate the droplet spectrum of hydraulic nozzles, under different pressures and spray liquid compositions, using a laser particle size analyzer. In a completely randomized design, two air induction twin flat-fan nozzles (AD-IA/D 11002 and AD-IA/D11004) and two hollow-cone nozzles (MAG - 2 and MAG - 4) were evaluated, in factorial design 3 x 2: tree spray pressures (207, 276 and 345 kPa for twin flat-fan nozzles, and 414, 483 and 552 kPa for cone nozzles); and two spray liquid compositions (water and water plus phosphatydilcoline + propionic acid adjuvant). The addition of adjuvant reduced the volume median diameter for the AD-IA/D 11002 and 11004 nozzles; however it had an opposite effect with the MAG - 4 nozzles and not changed with the MAG - 2 nozzles. In adverse weather conditions, it is not recommended the use of hollow cone spray nozzle, even with the addition of adjuvant tested because of the high risk potential of drift.
Resumo:
Pós-graduação em Agronomia (Energia na Agricultura) - FCA
Resumo:
Pós-graduação em Agronomia (Ciência do Solo) - FCAV