956 resultados para Drinking water.
Resumo:
The objective of this paper was to assess bacteriological quality of drinking water in a peri-urban area located in the Metropolitan Region of São Paulo, Brazil. A total of 89 water samples were collected from community plastic tanks and 177 water samples from wells were collected bimonthly, from September 2007 to November 2008, for evaluating bacteriological parameters including: Escherichia coli, Enterococcus and heterotrophic plate count (HPC). Clostridium perfringens was investigated in a subsample (40 samples from community plastic tank and 40 from wells). E. coli was present in 5 (5.6%) samples from community plastic tanks (2.0 - 5.1x10(4) MPN/100mL) and in 70 (39.5%) well samples (2.0 - 8.6x10(4) MPN/100mL). Thus, these samples were not in accordance with the Brazilian Regulation. Enterococcus was detected in 20 (22.5%) samples of the community plastic tanks (1 to 79 NC/100mL) and in 142 (80.2%) well samples (1 to >200 NC/100mL). C. perfringens was detected in 5 (12.5%) community plastic tanks samples and in 35 (87.5%) wells samples (2.2 to >16 MPN/100mL). HPC were above 500 CFU/mL in 5 (5.6%) waters from community plastic tanks. In wells samples, the HPC ranged from <1 to 1.6x10(4) CFU/mL. The residual chlorine did not attend the standard established in the drinking water legislation (0.2 mg/L), except in 20 (22.5%) samples. These results confirm the vulnerability of the water supply systems in this peri-urban area what is clearly a public health concern.
Resumo:
Aeromonas genus is considered an emerging pathogen and its presence in drinking water supplies is a reason to public health concern. This study investigated the occurrence of Aeromonas in samples from collective reservoirs and wells used as drinking water sources in a peri-urban area. A total of 35 water samples were collected from collective reservoirs and 32 from wells bimonthly, from September 2007 to September 2008. Aeromonas spp determination was carried out using a Multiple-Tube Technique. Samples were inoculated into alkaline peptone water and the superficial film formed was transferred to blood agar plates amended with ampicillin. Typical Aeromonas colonies were submitted to a biochemical screening and then to biochemical tests for species differentiation. Aeromonas was detected in 13 (19%) of the 69 samples examined (6 from collective reservoirs and 7 from wells). Concentrations of Aeromonas in collective reservoirs ranged from <0.3 to 1.2 x10²MPN/100mL and, in wells, from <0.3 to 2.4 x10²MPN/100mL. The most frequent specie in the collective reservoir samples was Aeromonas spp (68%), followed by A. encheleia (14%) and A. allosaccharophila (8%) and A. hydrophila (8%). Aeromonas spp (87%) was the most frequent specie isolated from well samples, followed by A. allosacchariphila (8%), A. encheleia (2%) and A. jandaei (5%). These data show the presence and diversity of Aeromonas genus in the samples analyzed and highlight that its presence in drinking water poses a significant public health concern.
Resumo:
Aeromonads are inhabitants of aquatic ecosystems and are described as being involved in intestinal disturbances and other infections. A total of 200 drinking water samples from domestic and public reservoirs and drinking fountains located in São Paulo (Brazil), were analyzed for the presence of Aeromonas. Samples were concentrated by membrane filtration and enriched in APW. ADA medium was used for Aeromonas isolation and colonies were confirmed by biochemical characterization. Strains isolated were tested for hemolysin and toxin production. Aeromonas was detected in 12 samples (6.0%). Aeromonas strains (96) were isolated and identified as: A. caviae (41.7%), A. hydrophila (15.7%), A.allosacharophila (10.4%), A. schubertii (1.0%) and Aeromonas spp. (31.2%).The results revealed that 70% of A. caviae, 66.7% of A. hydrophila, 80% of A. allosacharophila and 46.6% of Aeromonas spp. were hemolytic. The assay for checking production of toxins showed that 17.5% of A. caviae, 73.3% of A. hydrophila, 60% of A. allosacharophila, 100% of A. schubertii, and 33.3% of Aeromonas spp. were able to produce toxins. The results demonstrated the pathogenic potential of Aeromonas, indicating that the presence of this emerging pathogen in water systems is a public health concern
Resumo:
The protozoan parasites Giardia and Cryptosporidium have been described as important waterbone disease pathogens, and are associated with severe gastrointestinal illnesses. The objective of this paper was to investigate the presence of Giardia cysts and Cryptosporidium oocysts in sample from wtershed catchments and treated water sources. A total of 25 water samples were collected and examined according to the EPA - Method 1623, 2005, consisting of 12 from drinking water and 13 from raw water. Positive samples from raw water for Giardia cysts and Cryptosporidium oocysts were 46.1 and 7.6%, respectively. In finished water, positive samples were 41.7 per centfor Giardia cysts and 25 per cent for Cryptosporidium oocysts. Concentrations of Giardia cysts found in raw water samples ranged from "not detected" to 0.1oocysts/L, whereas concentrations of Cryptosporidium oocystsranged from "not detected" to 0.1 oocysts/L. In finished water, Giardia concentrations ranged from "not detected" to 0.06 cysts/L, and Cryptosporidium oocysts were not high in the samples analyzed. Nevertheless, the results of this study highlight the need to monitor these organisms in both raw and drinking water.
Resumo:
This paper presents the possible alternative removal options for the development of safe drinking water supply in the trace elements affected areas. Arsenic and chromium are two of the most toxic pollutants, introduced into natural waters from a variety of sources and causes various adverse effects on living bodies. Performance of three filter bed method was evaluated in the laboratory. Experiments have been conducted to investigate the sorption of arsenic and chromium on carbon steel and removal of trace elements from drinking water with a household filtration process. The affinity of the arsenic and chromium species for Fe/Fe(3)C (iron/iron carbide) sites is the key factor controlling the removal of the elements. The method is based on the use of powdered block carbon (PBC), powder carbon steel and ball ceramic in the ion-sorption columns as a cleaning process. The PBC modified is a satisfactory and practical sorbent for trace elements (arsenite and chromate) dissolved in water.
Resumo:
This paper presents the results of a research on direct drinking water treatment through an ultrafiltration pilot plant unit using spiral-wound membranes (3500 MWCO). The source of water is the Guarapiranga Reservoir, an eutrophicated water body located in the metropolitan region of Sao Paulo, Brazil. The data were collected during a period of almost 3400 h, from August 2005 to January 2006. The main objective of the study was to evaluate the membrane production capacity and contaminant removal efficiency. It was verified that the system was able to produce a high quality permeate with a flow close to the specified by the membrane manufacturer. The average permeate flow was 19.7 L.h(-1).m(-2), at 467 kPa and 25 degrees C, with a global water recovery of almost 85%. The removal efficiencies for TOC, UV light absorption, and turbidity were 85%, 56%, and 95%, respectively. The results provide substantial evidence of the technical feasibility of spiral-wound UF membranes for direct drinking water treatment from euthrophicated sources, as an alternative for conventional drinking water treatment systems.
Resumo:
Concern about the neurotoxicity of lead, particularly in infants and young children, has led to a revision of blood lead levels which are considered to involve an acceptable level of human exposure. Drinking water guidelines have also been reviewed in order to reduce this source of population exposure to lead. In the last 20 years, guidelines have been reduced from 100 to 50 to 10 mu g/litre. Lead in tap water used to be a major public health problem in Glasgow because of the high prevalence of houses with lead service pipes, the low pH of the public water supply and the resulting high levels of lead in water used for public consumption. Following two separate programmes of water treatment, involving the addition of lime and, a decade later, lime supplemented with orthophosphate, it is considered that maximal measures have been taken to reduce lead exposure by chemical treatment of the water supply. Any residual problem of public exposure would require large scale replacement of lead service pipes. In anticipation of the more stringent limits for lead in drinking water, we set out to measure current lead exposure From tap water in the population of Glasgow served by the Loch Katrine water supply. to compare the current situation with 12 years previously and to assess the public health implications of different limits. The study was based on mothers of young children since maternal blood lead concentrations and the domestic water that mothers use to prepare bottle feeds are the principal sources of foetal and infant lead exposure. An estimated 17% of mothers lived in households with tap water lead concentrations of 10 mu g/litre (the WHO guideline) or above in 1993 compared with 49% in 1981. Mean maternal blood lead concentrations fell by 69% in 12 years. For a given water lead concentration, maternal blood lead concentrations were 67% lower. The mean maternal blood lead concentration was 3.7 mu g/litre in the population at large, compared with 3.3 mu g/litre in households with negligible or absent tap water lead. Nevertheless, between 63% and 76% of cases of mothers with blood lead concentrations of 10 mu g/dl or above were attributable to tap water lead. The study found that maternal blood lead concentrations were well within limits currently considered safe for human health. About 15% of infants may be exposed via bottle feeds to tap water lead concentrations that exceed the WHO guideline of 10 mu g/litre. In the context of the health and social problems which affect the well-being and development of infants and children in Glasgow, however, current levels of lend exposure are considered to present a relatively minor health problem. (C) 2000 Elsevier Science Ltd. All rights reserved.
Resumo:
The presence of toxic cyanobacteria in drinking water reservoirs renders the need to develop treatment methods for the 'safe' removal of their associated toxins. Chlorine has been shown to successfully remove a range of cyanotoxins including microcystins, cylindrospermopsin and saxitoxins. Each cyanotoxin requires specific treatment parameters, particularly solution pH and free chlorine residual. However, currently there has not been any investigation into the toxicological effect of solutions treated for the removal of these cyanotoxins by chlorine. Using the P53(def) transgenic mouse model mate and female C57BL/6J hybrid mice were used to investigate potential cancer inducing effects from such oral dosing solutions. Both purified cyanotoxins and toxic cell-free extract cyanobacterial solutions were chlorinated and administered over 90 and 170 days (respectively) in drinking water. No increase in cancer was found in any treatment. The parent cyanotoxins, microcystins, cylindrospermopsin and saxitoxins were readily removed by chlorine. There was no significant increase in the disinfection byproducts trihalomethanes or haloacetic acids, levels found were well below guideline values. Histological examination identified no effect of treatment solutions except male mice treated with chlorinated cylindrospermopsin (as a cell free extract). In this instance 40% of males were found to have fatty vacuolation in their livers, cause unknown. It is recommended that further toxicology be undertaken on chlorinated cyanobacterial solutions, particularly for non-genotoxic carcinogenic compounds, for example the Tg. AC transgenic mouse model. (C) 2003 Elsevier Science Ltd. All rights reserved.
Resumo:
OBJECTIVE: To evaluate the microbiological quality of treated and untreated water samples came from urban and rural communities and to examine the relationship between coliforms occurrence and average water temperature, and a comparison of the rainfall levels. METHODS: A sample of 3,073 untreated and treated (chlorinated) water from taps (1,594), reservoir used to store treated water (1,033), spring water (96) and private well (350) collected for routine testing between 1996 and 1999 was analyzed by the multiple dilution tube methods used to detect the most probable number of total and fecal coliforms. These samples were obtained in the region of Maringá, state of Paraná, Brazil. RESULTS: The highest numbers water samples contaminated by TC (83%) and FC (48%) were found in the untreated water. TC and FC in samples taken from reservoirs used to store treated water was higher than that from taps midway along distribution lines. Among the treated water samples examined, coliform bacteria were found in 171 of the 1,033 sampling reservoirs. CONCLUSIONS: Insufficient treatment or regrowth is suggested by the observation that more than 17% of these treated potable water contained coliform. TC and FC positive samples appear to be similar and seasonally influenced in treated water. Two different periods must be considered for the occurrence of both TC and FC positive samples: (i) a warm-weather period (September-March) with high percentage of contaminated samples; and (ii) cold-weather period (April-August) were they are lower. Both TC and TF positive samples declined with the decreased of water temperature.
Resumo:
In a “perfect” drinking water system, the water quality for the consumers should be the same as the quality of the water leaving the treatment plant. However, some variability along the system can lead to a decrease in water quality (such as discolouration) which is usually reflected in the number of the customer complaints. This change may be related to the amount of sediment in the distribution network, leading to an increase in turbidity at the water supply. Since there is no such thing as a perfect drinking water system, the behaviour of particles in a drinking water network needs a suitable approach in order to understand how it works. Moreover, the combination of measurements, such as turbidity patterns and the Resuspension Potential Method (RPM) aid in the prevention of discoloured water complaints and intervention in the treatment upgrade or the network cleaning. Besides sediments there is also bacterial regrowth in the network, which is related to the water quality and distribution network characteristics. In a theoretical drinking water system higher velocities, temperature and shorter residences times lead to wider bacterial growth. In this study we observe velocity and residence steady-states and bacterial does not seem to be related to either. It can be concluded that adequate measurements of RPM, customer complaints and bacterial concentrations allow a wider knowledge on particle behaviour in drinking water systems.
Resumo:
Dissertação para Obtenção de Grau de Mestre em Engenharia Química e Bioquímica