941 resultados para Double Difference Method
Resumo:
Deutsche Forschungsgemeinschaft [SFB 858]
Resumo:
Among those damage identification methods, the Wavelet Packet Energy Curvature Difference (WPECD) Method is an effective one. However, most of the existing methods rely on numerical simulation and are unverified via experiment, and very few of them have been applied to practice. In this paper, the validity of WPECD in structural damage identification is verified by a numerical example. A damage simulation experiment is taken on a real replaced girder at the Ziya River New Bridge in Cangzhou. Two damage cases are applied and the acceleration responses at the measuring points are obtained, based on which the damages are identified with the WPECD Method, and the influence of wavelet function and decomposition level is studied. The results show that the WPECD Method can identify structure damage efficiently and can be put into practice.
Resumo:
Commission's seal on t.-p.
Resumo:
De todo ICMS arrecadado pelos estados brasileiros, 25% é distribuído aos municípios. Os estados são responsáveis por definir as regras de distribuição de 25% destes 25% do ICMS que é transferido aos municípios, os outros 75% seguem o critério do Valor Adicionado Fiscal. Alguns estados alteraram suas leis para que a distribuição seja realizada em função do desempenho dos municípios em algumas áreas com o intuito de incentiva-lo a melhorarem sua performance em busca de uma maior fatia do ICMS. Seguindo esta lógica está o estado do Ceará onde 100% do ICMS distribuído segundo regras estaduais é calculado a partir do desempenho dos municípios em indicadores de resultado nas áreas da educação (72%), saúde (20%) e meio ambiente (8%). Este estudo tem como objetivo estimar o efeito que a mudança da Lei de distribuição do ICMS do Ceará teve em indicadores de resultado da área da educação: IDEB e Prova Brasil. Para tanto, foi utilizado o método da Dupla Diferença por meio da construção de grupos de controle e tratamento. Assim, comparou-se a evolução do desempenho, anteriormente e posteriormente à mudança, de municípios cearenses com municípios parecidos de estados vizinhos, porém, não submetidos a mesma regra de distribuição de ICMS. De forma complementar, foram feitas outras duas analises separando os municípios do estado do Ceará entre ganhadores e perdedores de recursos de ICMS com a mudança na Lei e entre os detentores dos melhores e piores desempenhos de PIB per capita. Os resultados apontam impactos positivos no desempenho dos municípios cearenses tanto no IDEB quanto na Prova Brasil. Mesmo os municípios que perderam recursos com mudança das regras de distribuição de ICMS, melhoraram sua performance na educação. Os municípios mais pobres do estado, que apresentam desempenho pior do que os municípios mais ricos, aumentaram o desempenho reduzindo a diferença de proficiência se comparada aos municípios mais ricos. Neste sentido, há indícios de que a mudança na Lei do ICMS implementada pelo estado do Ceará gerou impactos positivos no desempenho dos municípios no IDEB e na Prova Brasil.
Resumo:
Essa tese é composta por três artigos na área de Economia da Educação que buscam investigar a questão do ensino médio técnico no Brasil. O primeiro e segundo artigos se inserem na literatura de avaliação de impacto dos tipos de ensino médio realizado, o de formação geral ou técnica, sobre os resultados do mercado de trabalho. Esse é um tema cada vez mais explorado em estudos empíricos internacionais, mas que ainda merece atenção dos pesquisadores no Brasil, seja para preencher lacunas no que se refere à identificação do efeito causal dessa política, seja porque o ensino técnico profissionalizante tenha se tornado alvo de maiores investimentos públicos nos últimos anos. Dessa forma, os dois artigos têm o propósito de estimar o efeito causal das habilidades técnicas adquiridas nos cursos técnicos de nível médio sobre os salários dos trabalhadores, no entanto se diferem pela fonte de dados utilizada. No primeiro artigo são utilizados os dados da Pesquisa Nacional por Amostra de Domicílios (IBGE) de 2007 e nossa contribuição está na estratégia de identificação do efeito causal, ao resolver o problema de auto seleção com o método de duplas diferenças (DD). Diversos testes de robustez foram realizados para dar suporte ao impacto positivo e estatisticamente significante que encontramos das habilidades técnicas sobre os salários, embora este seja restrito ao subgrupo de trabalhadores com no máximo o ensino médio completo. No segundo artigo foram utilizadas duas fontes de dados ainda não exploradas para esse fim, os microdados do ENEM (Exame Nacional do Ensino Médio) entre os anos de 2004 e 2006 e os dados da RAIS (Relação Anual de Informações Sociais) de 2009 a 2012 identificados por indivíduo (CPF). Por ser possível observar as notas dos jovens ao final do ensino médio, conseguimos separar os impactos do ensino médio técnico nos salários relacionados às habilidades técnicas específicas obtidas nos cursos técnicos, daqueles relacionados às habilidades gerais dos indivíduos (cognitivas ou não). Implementamos a estratégia de duplas diferenças e mais uma vez encontramos impacto positivo sobre os salários anuais dos jovens que concluíram o ensino médio técnico. Dessa vez nossos resultados são positivos tanto para os jovens que pararam seus estudos no ensino médio como para aqueles que concluíram o ensino superior. Verificamos a existência de heterogeneidade do efeito por região do país e nos quartis de distribuição de notas médias por escola no ENEM, indicando que os efeitos são crescentes com a qualidade oferecida pelas escolas. O terceiro artigo tem por objetivo estudar o mercado de trabalho no que diz respeito às ocupações tipicamente preenchidas por profissionais com nível médio técnico e analisar os diferenciais de salários dessas ocupações. A partir das ideias desenvolvidas no estudo, almejamos que ele seja orientador de políticas que relacionem educação técnica com demandas do mercado, com a finalidade de melhorar o matching entre formação e emprego. Entre as contribuições deste artigo estão a identificação e classificação das ocupações típicas de nível médio técnico pelo diferencial de salários, a correspondência entre as ocupações e as formações técnicas, a análise da atual oferta de vagas nos cursos correspondentes e o destaque para os cursos que parecem necessitar de maiores investimentos para o suprir as necessidades de mais profissionais.
Resumo:
Numerical methods ave used to solve double diffusion driven reactive flow transport problems in deformable fluid-saturated porous media. in particular, thp temperature dependent reaction rate in the non-equilibrium chemical reactions is considered. A general numerical solution method, which is a combination of the finite difference method in FLAG and the finite element method in FIDAP, to solve the fully coupled problem involving material deformation, pore-fluid flow, heat transfer and species transport/chemical reactions in deformable fluid-saturated porous media has been developed The coupled problem is divided into two subproblems which are solved interactively until the convergence requirement is met. Owing to the approximate nature of the numerical method, if is essential to justify the numerical solutions through some kind of theoretical analysis. This has been highlighted in this paper The related numerical results, which are justified by the theoretical analysis, have demonstrated that the proposed solution method is useful for and applicable to a wide range of fully coupled problems in the field of science and engineering.
Resumo:
OBJECTIVE: To determine the subjective response to iron therapy in non-anaemic women with unexplained fatigue. DESIGN: Double blind randomised placebo controlled trial. SETTING: Academic primary care centre and eight general practices in western Switzerland. PARTICIPANTS: 144 women aged 18 to 55, assigned to either oral ferrous sulphate (80 mg/day of elemental iron daily; n=75) or placebo (n=69) for four weeks. MAIN OUTCOME MEASURES: Level of fatigue, measured by a 10 point visual analogue scale. RESULTS: 136 (94%) women completed the study. Most had a low serum ferritin concentration; <or= 20 microg/l in 69 (51%) women. Mean age, haemoglobin concentration, serum ferritin concentration, level of fatigue, depression, and anxiety were similar in both groups at baseline. Both groups were also similar for compliance and dropout rates. The level of fatigue after one month decreased by -1.82/6.37 points (29%) in the iron group compared with -0.85/6.46 points (13%) in the placebo group (difference 0.95 points, 95% confidence interval 0.32 to 1.62; P=0.004). Subgroups analysis showed that only women with ferritin concentrations <or= 50 microg/l improved with oral supplementation. CONCLUSION: Non-anaemic women with unexplained fatigue may benefit from iron supplementation. The effect may be restricted to women with low or borderline serum ferritin concentrations.
Resumo:
Overactive bladder (OAB) is a prevalent condition with 16% of adults having one or more symptoms that significantly affect quality of life. Transcutaneous electrical nerve stimulation and neuromodulators have had success in treating OAB but are expensive, invasive, and sometimes cumbersome. We developed an alternative neuromodulatory technique that involves electromagnetic stimulation of the sacral nerve roots with a portable electromagnetic device to produce trans-sacral stimulation of the S3 and S4 sacral nerve roots. The aim of this study was to evaluate the impact of this device on OAB symptoms in women with a prospectively randomised double-blind controlled study. Following a power analysis, women with symptoms of OAB were prospectively recruited with ethical approval for randomisation to an active treatment (n = 33) or placebo group (n = 30) in a double-blind trial. The patient, at home, used the belt device daily for 20 min over 12 weeks. Outcome measures included a 3-day voiding diary, 1 h pad test, visual analogue score (VAS) for symptom impact (0-100%), Kings Health Questionnaire (KHQ) and Australian Quality of Life questionnaire (AQOL) at baseline, 6 and 12 weeks. Overall, no difference was found between groups for any of the research questions. Specifically, we were unable to demonstrate any difference between the active and sham device groups in frequency, nocturia, urinary leakage, or quality of life, nor was there any evidence of a placebo effect. The quality of the data was high with the number of missing observations (especially for disease specific KHQ and general AQOL) being few. This attempt to promote trans-sacral electromagnetic neuromodulation with a specially created device was ineffective on the symptoms of OAB.
Resumo:
BACKGROUND: Three small trials suggest that intravenous immunoglobulin can affect biomarkers and symptoms of mild-to-moderate Alzheimer's disease. We tested the safety, effective dose, and infusion interval of intravenous immunoglobulin in such patients. METHODS: We did a multicentre, placebo-controlled phase 2 trial at seven sites in the USA and five in Germany. Participants with probable Alzheimer's disease aged 50-85 years were randomly assigned (by a computer-generated randomisation sequence, with block sizes of eight) to infusions every 4 weeks (0·2, 0·5, or 0·8 g intravenous immunoglobulin per kg bodyweight, or placebo) or infusions every 2 weeks (0·1, 0·25, or 0·4 g/kg, or placebo). Patients, caregivers, investigators assessing outcomes, and staff at imaging facilities and the clinical research organisation were masked to treatment allocation, but dispensing pharmacists, the statistician, and the person responsible for final PET analyses were not. Treatment was masked with opaque pouches and infusion lines. The primary endpoint was median area under the curve (AUC) of plasma amyloid β (Aβ)(1-40) between the last infusion and the final visit (2 weeks or 4 weeks depending on infusion interval) in the intention-to-treat population. The trial is registered at ClinicalTrials.gov (NCT00812565) and controlled-trials.com (ISRCTN64846759). FINDINGS: 89 patients were assessed for eligibility, of whom 58 were enrolled and 55 included in the primary analysis. Median AUC of plasma Aβ(1-40) was not significantly different for intravenous immunoglobulin compared with placebo for five of the six intervention groups (-18·0 [range -1347·0 to 1068·5] for 0·2 g/kg, -364·3 [-5834·5 to 1953·5] for 0·5 g/kg, and -351·8 [-1084·0 to 936·5] for 0·8 g/kg every 4 weeks vs -116·3 [-1379·0 to 5266·0] for placebo; and -13·8 [-1729·0 to 307·0] for 0·1 g/kg, and -32·5 [-1102·5 to 451·5] for 0·25 g/kg every 2 weeks vs 159·5 [51·5 to 303·0] for placebo; p>0·05 for all). The difference in median AUC of plasma Aβ(1-40) between the 0·4 g/kg every 2 weeks group (47·0 [range -341·0 to 72·5]) and the placebo group was significant (p=0·0216). 25 of 42 (60%) patients in the intervention group versus nine of 14 (64%) receiving placebo had an adverse event. Four of 42 (10%) patients in the intravenous immunoglobulin group versus four of 14 (29%) receiving placebo had a serious adverse event, including one stroke in the intervention group. INTERPRETATION: Intravenous immunoglobulin may have an acceptable safety profile. Our results did not accord with those from previous studies. Longer trials with greater power are needed to assess the cognitive and functional effects of intravenous immunoglobulin in patients with Alzheimer's disease.
Resumo:
The ionospheric effect is one of the major errors in GPS data processing over long baselines. As a dispersive medium, it is possible to compute its influence on the GPS signal with the ionosphere-free linear combination of L1 and L2 observables, requiring dual-frequency receivers. In the case of single-frequency receivers, ionospheric effects are either neglected or reduced by using a model. In this paper, an alternative for single-frequency users is proposed. It involves multiresolution analysis (MRA) using a wavelet analysis of the double-difference observations to remove the short- and medium-scale ionosphere variations and disturbances, as well as some minor tropospheric effects. Experiments were carried out over three baseline lengths from 50 to 450 km, and the results provided by the proposed method were better than those from dual-frequency receivers. The horizontal root mean square was of about 0.28 m (1 sigma).
Resumo:
To ensure high accuracy results from GPS relative positioning, the multipath effects have to be mitigated. Although the careful selection of antenna site and the use of especial antennas and receivers can minimize multipath, it cannot always be eliminated and frequently the residual multipath disturbance remains as the major error in GPS results. The high-frequency multipath from large delays can be attenuated by double difference (DD) denoising methods. But the low-frequency multipath from short delays is very difficult to be reduced or modeled. In this paper, it is proposed a method based on wavelet regression (WR), which can effectively detect and reduce the low-frequency multipath. The wavelet technique is firstly applied to decompose the DD residuals into the low-frequency bias and high-frequency noise components. The extracted bias components by WR are then directly applied to the DD observations to correct them from the trend. The remaining terms, largely characterized by the high-frequency measurement noise, are expected to give the best linear unbiased solutions from a least-squares (LS) adjustment. An experiment was carried out using objects placed close to the receiver antenna to cause, mainly, low-frequency multipath. The data were collected for two days to verify the multipath repeatability. The ground truth coordinates were computed with data collected in the absence of the reflector objects. The coordinates and ambiguity solution were compared with and without the multipath mitigation using WR. After mitigating the multipath, ambiguity resolution became more reliable and the coordinates were more accurate.
Resumo:
Background: Several anti-inflammatory drugs have been used to reduce pain and discomfort after periodontal surgeries. This study evaluates the efficacy of using etoricoxib and dexamethasone for pain prevention after open-flap debridement surgery. Methods: For this prospective, double-masked, crossover, placebo-controlled, randomized clinical trial, open-flap debridement surgeries were performed on 15 patients (eight males and seven females, age range 20 to 56 years: mean age ± SD: 40 ± 9.7 years) who presented with chronic periodontitis after nonsurgical periodontal therapy at three quadrants. Each patient underwent three surgical procedures at intervals of 30 days and received one of the following premedication protocols 1-hour before surgery: group 1 = placebo, group 2 = 8 mg dexamethasone, and group 3 = 120 mg etoricoxib. Rescue medication (750 mg acetaminophen) was given to each patient who was instructed to take it when necessary. Pain intensity and discomfort were evaluated by a 101-point numeric rate scale and a four-point verbal rate scale, respectively, hourly for the first 8 hours after surgery and three times a day on the following 3 days. Results: The results demonstrate that groups 2 and 3 present reduced postoperative pain-intensity levels compared to group 1. There were statistically significant differences at the 4, 5, 6, 7, and 8 hour-periods after surgery (Friedman test; P<0.05). Furthermore, rescue-medication intake was significantly lower for groups 2 and 3 than for group 1 (analysis of variance; P<0.02). Conclusion: The adoption of a preemptive medication protocol using etoricoxib or dexamethasone may be considered effective for pain and discomfort prevention after open-flap debridement surgeries.
Resumo:
This work is part of a research under construction since 2000, in which the main objective is to measure small dynamic displacements by using L1 GPS receivers. A very sensible way to detect millimetric periodic displacements is based on the Phase Residual Method (PRM). This method is based on the frequency domain analysis of the phase residuals resulted from the L1 double difference static data processing of two satellites in almost orthogonal elevation angle. In this article, it is proposed to obtain the phase residuals directly from the raw phase observable collected in a short baseline during a limited time span, in lieu of obtaining the residual data file from regular GPS processing programs which not always allow the choice of the aimed satellites. In order to improve the ability to detect millimetric oscillations, two filtering techniques are introduced. One is auto-correlation which reduces the phase noise with random time behavior. The other is the running mean to separate low frequency from the high frequency phase sources. Two trials have been carried out to verify the proposed method and filtering techniques. One simulates a 2.5 millimeter vertical antenna displacement and the second uses the GPS data collected during a bridge load test. The results have shown a good consistency to detect millimetric oscillations.
Resumo:
A modeling study was completed to develop a methodology that combines the sequencing and finite difference methods for the simulation of a heterogeneous model of a tubular reactor applied in the treatment of wastewater. The system included a liquid phase (convection diffusion transport) and a solid phase (diffusion reaction) that was obtained by completing a mass balance in the reactor and in the particle, respectively. The model was solved using a pilot-scale horizontal-flow anaerobic immobilized biomass (HAIB) reactor to treat domestic sewage, with the concentration results compared with the experimental data. A comparison of the behavior of the liquid phase concentration profile and the experimental results indicated that both the numerical methods offer a good description of the behavior of the concentration along the reactor. The advantage of the sequencing method over the finite difference method is that it is easier to apply and requires less computational time to model the dynamic simulation of outlet response of HAIB.