941 resultados para Dose calibrator
Resumo:
Objective: The present study was aimed at evaluating the viability of replacing 18F with 99mTc in dose calibrator linearity testing. Materials and Methods: The test was performed with sources of 99mTc (62 GBq) and 18F (12 GBq) whose activities were measured up to values lower than 1 MBq. Ratios and deviations between experimental and theoretical 99mTc and 18F sources activities were calculated and subsequently compared. Results: Mean deviations between experimental and theoretical 99mTc and 18F sources activities were 0.56 (± 1.79)% and 0.92 (± 1.19)%, respectively. The mean ratio between activities indicated by the device for the 99mTc source as measured with the equipment pre-calibrated to measure 99mTc and 18F was 3.42 (± 0.06), and for the 18F source this ratio was 3.39 (± 0.05), values considered constant over the measurement time. Conclusion: The results of the linearity test using 99mTc were compatible with those obtained with the 18F source, indicating the viability of utilizing both radioisotopes in dose calibrator linearity testing. Such information in association with the high potential of radiation exposure and costs involved in 18F acquisition suggest 99mTc as the element of choice to perform dose calibrator linearity tests in centers that use 18F, without any detriment to the procedure as well as to the quality of the nuclear medicine service.
Resumo:
Introduction: Paper and thin layer chromatography methods are frequently used in Classic Nuclear Medicine for the determination of radiochemical purity (RCP) on radiopharmaceutical preparations. An aliquot of the radiopharmaceutical to be tested is spotted at the origin of a chromatographic strip (stationary phase), which in turn is placed in a chromatographic chamber in order to separate and quantify radiochemical species present in the radiopharmaceutical preparation. There are several methods for the RCP measurement, based on the use of equipment as dose calibrators, well scintillation counters, radiochromatografic scanners and gamma cameras. The purpose of this study was to compare these quantification methods for the determination of RCP. Material and Methods: 99mTc-Tetrofosmin and 99mTc-HDP are the radiopharmaceuticals chosen to serve as the basis for this study. For the determination of RCP of 99mTc-Tetrofosmin we used ITLC-SG (2.5 x 10 cm) and 2-butanone (99mTc-tetrofosmin Rf = 0.55, 99mTcO4- Rf = 1.0, other labeled impurities 99mTc-RH RF = 0.0). For the determination of RCP of 99mTc-HDP, Whatman 31ET and acetone was used (99mTc-HDP Rf = 0.0, 99mTcO4- Rf = 1.0, other labeled impurities RF = 0.0). After the development of the solvent front, the strips were allowed to dry and then imaged on the gamma camera (256x256 matrix; zoom 2; LEHR parallel-hole collimator; 5-minute image) and on the radiochromatogram scanner. Then, strips were cut in Rf 0.8 in the case of 99mTc-tetrofosmin and Rf 0.5 in the case of 99mTc-HDP. The resultant pieces were smashed in an assay tube (to minimize the effect of counting geometry) and counted in the dose calibrator and in the well scintillation counter (during 1 minute). The RCP was calculated using the formula: % 99mTc-Complex = [(99mTc-Complex) / (Total amount of 99mTc-labeled species)] x 100. Statistical analysis was done using the test of hypotheses for the difference between means in independent samples. Results:The gamma camera based method demonstrated higher operator-dependency (especially concerning the drawing of the ROIs) and the measures obtained using the dose calibrator are very sensitive to the amount of activity spotted in the chromatographic strip, so the use of a minimum of 3.7 MBq activity is essential to minimize quantification errors. Radiochromatographic scanner and well scintillation counter showed concordant results and demonstrated the higher level of precision. Conclusions: Radiochromatographic scanners and well scintillation counters based methods demonstrate to be the most accurate and less operator-dependant methods.
Resumo:
Pressurized re-entrant (or 4 pi) ionization chambers (ICs) connected to current-measuring electronics are used for activity measurements of photon emitting radionuclides and some beta emitters in the fields of metrology and nuclear medicine. As a secondary method, these instruments need to be calibrated with appropriate activity standards from primary or direct standardization. The use of these instruments over 50 years has been well described in numerous publications, such as the Monographie BIPM-4 and the special issue of Metrologia on radionuclide metrology (Ratel 2007 Metrologia 44 S7-16, Schrader1997 Activity Measurements With Ionization Chambers (Monographie BIPM-4) Schrader 2007 Metrologia 44 S53-66, Cox et al 2007 Measurement Modelling of the International Reference System (SIR) for Gamma-Emitting Radionuclides (Monographie BIPM-7)). The present work describes the principles of activity measurements, calibrations, and impurity corrections using pressurized ionization chambers in the first part and the uncertainty analysis illustrated with example uncertainty budgets from routine source-calibration as well as from an international reference system (SIR) measurement in the second part.
Resumo:
After the discovery of ionizing radiation, its applications in various fields of science began to take significant proportions. In the case of medicine, there are the application areas in radiotherapy, diagnostic radiology and nuclear medicine. It was then necessary to create the field of radiological protection to establish the conditions necessary for the safe use of such ionizing radiation. Apply knowledge obtained during the graduation stage and in the practice of radiological protection in the areas of nuclear medicine and diagnostic radiology. In the area of nuclear medicine, tests were made in the Geiger-Muller counters (GM) and the dose calibrator (curiometer), the monitoring tests of radiation, waste management, clean of the Therapeutic room and testing the quality control of gamma-chambers. In the area of radiology, were performed tests of quality control equipment for conventional X-ray equipment and x-ray fluoroscopy, all following the rules of the National Health Surveillance Agency (ANVISA), and reporting of tests. The routine developed in the fields of nuclear medicine in hospitals has proved very useful, since the quality control of GM counters contribute to the values of possible contamination are more reliable. The control of dose calibrator enables the patient not to receive different doses of the recommended amounts, which prevents the repetition of tests and unnecessary exposure to radiation. The management of waste following the rules and laws established and required for its management. Tests for quality control of gamma chambers help to evaluate its medical performance through image. In part of diagnostic radiology, tests for quality control are performed in order to verify that the equipment is acceptable for usage or if repairs are needed. The knowledge acquired at the internship consolidated the learning of graduation course
Resumo:
Phase I trials use a small number of patients to define a maximum tolerated dose (MTD) and the safety of new agents. We compared data from phase I and registration trials to determine whether early trials predicted later safety and final dose. We searched the U.S. Food and Drug Administration (FDA) website for drugs approved in nonpediatric cancers (January 1990-October 2012). The recommended phase II dose (R2PD) and toxicities from phase I were compared with doses and safety in later trials. In 62 of 85 (73%) matched trials, the dose from the later trial was within 20% of the RP2D. In a multivariable analysis, phase I trials of targeted agents were less predictive of the final approved dose (OR, 0.2 for adopting ± 20% of the RP2D for targeted vs. other classes; P = 0.025). Of the 530 clinically relevant toxicities in later trials, 70% (n = 374) were described in phase I. A significant relationship (P = 0.0032) between increasing the number of patients in phase I (up to 60) and the ability to describe future clinically relevant toxicities was observed. Among 28,505 patients in later trials, the death rate that was related to drug was 1.41%. In conclusion, dosing based on phase I trials was associated with a low toxicity-related death rate in later trials. The ability to predict relevant toxicities correlates with the number of patients on the initial phase I trial. The final dose approved was within 20% of the RP2D in 73% of assessed trials.
Resumo:
To assess the effects of a soy dietary supplement on the main biomarkers of cardiovascular health in postmenopausal women compared with the effects of low-dose hormone therapy (HT) and placebo. Double-blind, randomized and controlled intention-to-treat trial. Sixty healthy postmenopausal women, aged 40-60 years, 4.1 years mean time since menopause were recruited and randomly assigned to 3 groups: a soy dietary supplement group (isoflavone 90mg), a low-dose HT group (estradiol 1 mg plus noretisterone 0.5 mg) and a placebo group. Lipid profile, glucose level, body mass index, blood pressure and abdominal/hip ratio were evaluated in all the participants at baseline and after 16 weeks. Statistical analyses were performed using the χ2 test, Fisher's exact test, Kruskal-Wallis non-parametric test, analysis of variance (ANOVA), paired Student's t-test and Wilcoxon test. After a 16-week intervention period, total cholesterol decreased 11.3% and LDL-cholesterol decreased 18.6% in the HT group, but both did not change in the soy dietary supplement and placebo groups. Values for triglycerides, HDL-cholesterol, glucose level, body mass index, blood pressure and abdominal/hip ratio did not change over time in any of the three groups. The use of dietary soy supplement did not show any significant favorable effect on cardiovascular health biomarkers compared with HT. The trial is registered at the Brazilian Clinical Trials Registry (Registro Brasileiro de Ensaios Clínicos - ReBEC), number RBR-76mm75.
Resumo:
Fingolimod is a new and efficient treatment for multiple sclerosis (MS). The drug administration requires special attention to the first dose, since cardiovascular adverse events can be observed during the initial six hours of fingolimod ingestion. The present study consisted of a review of cardiovascular data on 180 patients with MS receiving the first dose of fingolimod. The rate of bradycardia in these patients was higher than that observed in clinical trials with very strict inclusion criteria for patients. There were less than 10% of cases requiring special attention, but no fatal cases. All but one patient continued the treatment after this initial dose. This is the first report on real-life administration of fingolimod to Brazilian patients with MS, and one of the few studies with these characteristics in the world.
A Feasibility Study Of Fricke Dosimetry As An Absorbed Dose To Water Standard For 192ir Hdr Sources.
Resumo:
High dose rate brachytherapy (HDR) using 192Ir sources is well accepted as an important treatment option and thus requires an accurate dosimetry standard. However, a dosimetry standard for the direct measurement of the absolute dose to water for this particular source type is currently not available. An improved standard for the absorbed dose to water based on Fricke dosimetry of HDR 192Ir brachytherapy sources is presented in this study. The main goal of this paper is to demonstrate the potential usefulness of the Fricke dosimetry technique for the standardization of the quantity absorbed dose to water for 192Ir sources. A molded, double-walled, spherical vessel for water containing the Fricke solution was constructed based on the Fricke system. The authors measured the absorbed dose to water and compared it with the doses calculated using the AAPM TG-43 report. The overall combined uncertainty associated with the measurements using Fricke dosimetry was 1.4% for k = 1, which is better than the uncertainties reported in previous studies. These results are promising; hence, the use of Fricke dosimetry to measure the absorbed dose to water as a standard for HDR 192Ir may be possible in the future.
Resumo:
The chronic treatment with phenytoin or the acute intoxication by this drug may cause permanent cerebellar injury with atrophy of cerebellum vermis and hemispheres, which can be detected by neuroimaging studies. The aim of the present study was to investigate the correlation between the dosage and duration of treatment with phenytoin and the occurrence of cerebellar atrophy. Sixty-six patients were studied and had their tomographies analyzed for cerebellar atrophy. Of the 66 patients studied, 18 had moderate/severe atrophy, 15 had mild atrophy and 33 were considered to be normal. The patients with moderate/severe atrophy were those with higher exposure to phenytoin (longer duration of treatment and higher total dosage) showing statistically significant difference when compared to patients with mild atrophy or without atrophy (p=0.02). Further, the patients with moderate/severe atrophy had serum levels of phenytoin statistically higher than those of patients with mild atrophy or without atrophy (p = 0.008). There was no association between other antiepileptic drugs dosage or duration of treatment and degree of cerebellar atrophy. We also found that older patients had cerebellar atrophy more frequently, indicating that age or duration of the seizure disorder may also be important in the determination of cerebellar degeneration in these patients. We conclude that although there is a possibility that repeated seizures contribute to cerebellar damage, long term exposure to phenytoin, particularly in high doses and toxic serum levels, cause cerebellar atrophy.
Resumo:
Purpose: To analyze the effects of 100 mg of sildenafil citrate (Viagra®) on the retrobulbar circulation and visual field. Methods: A double masked, placebo controlled study was conducted in 10 males with a mean age of 27.7 + 5.68 years. The right eye of each volunteer underwent orbital color Doppler imaging and automated perimetry (Humphrey, program 30-2, Full-Threshold Strategy) at 3 occasions: baseline, 1 hour after placebo and 1 hour after 100 mg of sildenafil. The foveal threshold and the mean deviation (MD) were analyzed by automated perimetry on the three occasions. Color Doppler imaging allowed the measurement of the peak systolic velocity (PSV), end diastolic velocity (EDV) and Pourcelot index (PI) in the central retinal artery and ophthalmic artery. Results: The foveal threshold and the mean deviation did not show a significant change following the administration of sildenafil. The ophthalmic artery peak systolic velocity and end diastolic velocity significantly increased after the administration of sildenafil (p<0.001). The hemodynamic parameters in the central retinal artery and the ophthalmic artery PI did not significantly change. Conclusions: Sildefanil citrate increased the blood flow velocities in the ophthalmic artery in normal subjects, with no significant changes in the foveal threshold and mean deviation in the automated perimetry.
Resumo:
The objective was to determine the cardiopulmonary effects and eyeball centralization time obtained with 15 or 30µg kg-1 of atracurium in anesthetized dogs under spontaneous breathing. Eighteen healthy adult mixed-breed dogs were used, which received 0.1mg kg-1 acepromazine and 0.5mg kg-1 morphine IM, followed by 4mg kg-1 propofol IV and maintained on isoflurane anesthesia with spontaneous breathing. Animals received 1mL 0.9% NaCl IV (CG), 15µg kg-1 (G15) or 30µg kg-1 (G30) of atracurium IV. Eyeball centralization time was measured; heart rate (HR), systolic (SAP), mean (MAP) and diastolic (DAP) arterial pressures, respiratory rate (RR), tidal volume (Vt) and minute volume (Vm) were determined every 5min, and pH, arterial CO2 pressure (PaCO2 ), arterial O2 pressure (PaO2 ), hemoglobin oxygen saturation (SaO2 ), bicarbonate (HCO3-) and base excess (BE) every 15min until 60min. Both doses of atracurium produced a similar period of eyeball centralization. Vt in groups treated with atracurium was lower than in CG up to 15min. Vm in G15 differed from CG up to 10min and in G30 up to 25min. No differences were observed for cardiovascular parameters, RR, SaO2, PaO2, HCO3- and BE. pH decreased in CG between 30 and 60min and in G15 and G30 at 15min. G30 differed from CG between 15 and 30min. PaCO2 in GC differed from baseline between 30 and 60min and in G15 differed at 15min. Atracurium at the dose of 15µg kg-1 is adequate for short corneal procedures in inhalant-anesthetized dogs under spontaneous breathing.
Effect of therapeutic dose X rays on mechanical and chemical properties of esthetic dental materials
Resumo:
The aim of this study was to investigate the influence of therapeutic dose X rays on the microhardness (MH) and degree of conversion (DC) of two different esthetic restorative dental materials. The materials were photo-activated with a LED light-curing unit using three cure-times: 5, 20 and 40 seconds. The photo-activation was carried out in two distinct periods: before and after irradiation with doses of 5, 35 and 70 Gy, from a 6 MV X rays beam. In accordance with the methodology used, it was conclude that a therapeutic dose does not have a detrimental effect on the photoinitiator molecules, because the photo-activation occurred after they were irradiated. When the irradiation was applied before photo-activation, the materials showed MH improvement, but when photo-activation was performed after irradiation, there was less improvement. However, there was no correlation between MH and DC. Thus, a therapeutic dose applied to cured material can promote linking and breaking of chain bonds in a non-linear way.
Resumo:
Este trabalho avaliou a concentração dos radioelementos K, eU e eTh em amostras de granitos do Estado de Rondônia, Brasil. A análise estatística dos dados obtidos indicou que eles seguem distribuições lognormais. Os valores modais encontrados correspondem a cerca de 11% para K, 29 ppm para eU e 85 ppm para eTh. Correlações diretas significativas foram determinadas entre as concentrações dos três radioelementos, isto é, r = 0,71 (entre K e eU), r = 0,72 (entre K e eTh)e r = 0,72 (entre eU e eTh), sugerindo que são congruentes os processos de seu acúmulo nos minerais das rochas analisadas. Os dados de concentração permitiram estimar a taxa de dose absorvida de radiação no ar acima de 1 m do nível do terreno, a qual também segue uma distribuição lognormal, com valor modal de 2,7 mSv/ano, que é ligeiramente superior à média global de 2,4 mSv/ano. Os resultados obtidos também permitiram avaliar, do ponto de vista radiométrico, se os granitos analisados são adequados para emprego como revestimento em construção civil.
Resumo:
The endocannabinoid system is involved in the control of many physiological functions, including the control of emotional states. In rodents, previous exposure to an open field increases the anxiety-like behavior in the elevated plus-maze. Anxiolytic-like effects of pharmacological compounds that increase endocannabinoid levels have been well documented. However, these effects are more evident in animals with high anxiety levels. Several studies have described characteristic inverted U-shaped dose-response effects of drugs that modulate the endocannabinoid levels. However, there are no studies showing the effects of different doses of exogenous anandamide, an endocannabinoid, in animal models of anxiety. Thus, in the present study, we determined the dose-response effects of exogenous anandamide at doses of 0.01, 0.1, and 1.0 mg/kg in C57BL/6 mice (N = 10/group) sequentially submitted to the open field and elevated plus-maze. Anandamide was diluted in 0.9% saline, ethyl alcohol, Emulphor® (18:1:1) and administered ip (0.1 mL/10 g body weight); control animals received the same volume of anandamide vehicle. Anandamide at the dose of 0.1 mg/kg (but not of 0.01 or 1 mg/kg) increased (P < 0.05) the time spent and the distance covered in the central zone of the open field, as well as the exploration of the open arms of the elevated plus-maze. Thus, exogenous anandamide, like pharmacological compounds that increase endocannabinoid levels, promoted a characteristic inverted U-shaped dose-response effect in animal models of anxiety. Furthermore, anandamide (0.1 mg/kg) induced an anxiolytic-like effect in the elevated plus-maze (P < 0.05) after exposing the animals to the open field test.
Resumo:
This study evaluated the effects of high-dose of short-term creatine supplementation (5g.kg(-1). day(-1) to 1 week) and long-term creatine supplementation (1g.kg(-1). day(-1) to 4-8 weeks) on kidney and liver structure and function of sedentary and exercised Wistar rats ( Exercise sessions consisted of swimming at 80% of maximal work load supported during 5 days per week with daily sessions of 60 minutes throughout the duration of the supplementation). Seventy-two animals ( 245 +/- 5g) were divided into four groups (n = 18): control diet Sedentary ( SED), Creatine diet Sedentary (CRE), control diet Exercised (EXE), and Creatine diet Exercised (EXECRE). Histological and blood biochemical studies were performed after one, four, and eight weeks of creatine supplementation and exercise ( n = 6). No differences were found when comparing SED, EXE and EXECRE groups for kidney and liver structure and function at one, four and eight weeks. However, the CRE group showed higher levels of creatinine (1.1 +/- 0.2 vs. 0.4 +/- 0.1 mg.dl(-1); p < 0.05), and urea ( 37 +/- 3 vs. 19 +/- 1 mg. dl(-1); p < 0.05) when compared with all others groups at four and eight weeks. At eight weeks, the CRE group presented increased levels of ALT (41 +/- 7 vs. 23 +/- 7 U.L(-1); p < 0.05), AST (89 +/- 6 vs. 62 +/- 5 U. L(-1); p < 0.05), GGT (8.0 +/- 0.9 vs. 3.9 +/- 1.0 U. L(-1); p < 0.05), and AP (125 +/- 10 vs. 69 +/- 9 U. L(-1); p < 0.05) also when compared with all others groups. Moreover, the CRE group demonstrated some structural alterations indicating renal and hepatic damage at four and eight weeks, respectively. These results suggest that long-term creatine supplementation (up to 4-8 weeks) may adversely affect kidney and liver structure and function of sedentary but not of exercised rats.