986 resultados para Doppler flowmeter
Resumo:
A synthetic human atrial natriuretic peptide of 26 aminoacids [human (3-28)ANP or hANP] was infused into normal male volunteers. Six subjects were infused for 4 h at 1-wk intervals with either hANP at the rate of 0.5 or 1.0 microgram/min or its vehicle in a single-blind randomized order. Human (3-28)ANP at the dose of 0.5 microgram/min raised immunoreactive plasma ANP levels from 104 +/- 17 to 221 +/- 24 pg/ml (mean +/- SEM), but it induced no significant change in blood pressure, heart rate, effective renal plasma flow, glomerular filtration rate, or renal electrolyte excretion. At the rate of 1.0 microgram/min, human (3-28)ANP increased immunoreactive plasma ANP levels from 89 +/- 12 to 454 +/- 30 pg/ml. It reduced effective renal plasma flow from 523 +/- 40 to 453 +/- 38 ml/min (P less than 0.05 vs. vehicle), but left glomerular filtration rate unchanged. Natriuresis rose from 207 +/- 52 to 501 +/- 69 mumol/min (P less than 0.05 vs. vehicle) and urinary magnesium excretion from 3.6 +/- 0.5 to 5.6 +/- 0.5 mumol/min (P less than 0.01 vs. vehicle). The excretion rate of the other electrolytes, blood pressure, and heart rate were not significantly modified. At both doses, human (3-28)ANP tended to suppress the activity of the renin-angiotensin-aldosterone system. In 3 additional volunteers, the skin blood flow response to human (3-28)ANP, infused for 4 h at the rate of 1.0 microgram/min, was studied by means of a laser-doppler flowmeter. The skin blood flow rose during the first 2 h of peptide administration, then fell progressively to values below baseline. After the infusion was discontinued, it remained depressed for more than 2 h. Thus, in normal volunteers, human (3-28)ANP at the dose of 1.0 microgram/min produced results similar to those obtained previously with rat (3-28)ANP. It enhanced natriuresis without changing the glomerular filtration rate while effective renal plasma flow fell. It also induced a transient vasodilation of the skin vascular bed.
Resumo:
Deep venous thrombosis is a relatively common disease, which can present pulmonary embolism as a complication in its acute phase, and later the post-thrombotic syndrome. Thus, diagnosis should be made as soon as possible, in order to prevent or minimize such complications. Several studies have shown that the symptoms and the clinical signs are inaccurate for the deep venous thrombosis diagnosis and that complementary exams are necessary. As an attempt to simplify the patients' assessment, Well et al., in 1997, developed a clinical prediction index that combines symptoms, signs and risk factors for deep venous thrombosis and managed to make a simpler approach through an association of this index with the complementary exams. Phlebography has been considered the gold standard of complementary exams. However, since it is an invasive exam and thus subject to complications, other diagnostic methods were introduced aiming at making the diagnostic approach simpler and less invasive. Doppler ultrasound, duplex scan, impedance plethysmography, computed tomography, and blood tests such as the D-dimer are some of the available methods for assessing the patient with suspicion of deep venous thrombosis. Among them, duplex scan has shown excellent accuracy and it is currently widely accepted as the first choice test for approaching the patient with deep venous thrombosis. Several authors have suggested an association of diagnostic methods to simplify and make the assessment of such patients more cost-effective, leading to the introduction of a wide range of diagnostic strategies. The different diagnostic methods used for assessing deep venous thrombosis are discussed, as well as a review of the literature on the accuracy, advantages and disadvantages of these methods. Copyright © 2005 by Sociedade Brasileira de Angiologia e Cirurgia Vascular.
Resumo:
Introduction. Tendon injury is a major cause of lameness and decreased performance in athletic equines. Various therapies for tendonitis have been described; however, none of these therapies results in complete tissue regeneration, and the injury recurrence rate is high even after long recovery periods involving rest and physiotherapy. Methods. A lesion was induced with collagenase gel in the superficial digital flexor tendon in the center portion of the metacarpal region of eight equines of mixed breed. After two weeks, the lesions of the animals in the treated and control groups were treated through the intralesional administration of mesenchymal stem cells derived from adipose tissue (adMSCs) suspended in platelet concentrate (PC) and with phosphate buffered saline (PBS), respectively. Serial ultrasound analyses were performed every two weeks. After 16 weeks of therapy, a biopsy was performed for histopathological, immunohistochemical and gene expression (type I collagen (COL1A1), type III collagen (COL3A1), tenascin-C (TNC), tenomodulin (TNMD), and scleraxis (SCX)) analyses. Results: Differences in the ultrasound and histopathological analyses were observed between the groups. Improved results were reported in the group treated with adMSCs suspended in PC. There was no difference in the gene expression levels observed after the different treatments. The main results observed from the histopathological evaluation of the treated group were as follows: a prevention of the progression of the lesion, a greater organization of collagen fibers, and a decreased inflammatory infiltrate. A lack of progression of the lesion area and its percentage was observed in the ultrasound image, and increased blood flow was measured by Power Doppler. Conclusions: The use of adMSCs combined with PC for the therapy of experimentally induced tendonitis prevented the progression of the tendon lesion, as observed in the ultrasound examination, and resulted in a greater organization and decreased inflammation, as observed in the histopathological evaluation. These data demonstrate the therapeutic potential of this therapy for the treatment of equine tendonitis. © 2013 Carvalho et al.; licensee BioMed Central Ltd.
Resumo:
There were three principle aims to this thesis. Firstly, the acquisition protocols of clinical blood flow apparatus were investigated in order to optimise them for both cross-sectional and longitudinal application. Secondly, the effects of physiological factors including age and systematic circulation on ocular blood flow were investigated. Finally, the ocular perfusion characteristics of patients diagnosed with ocular diseases considered to be of a vascular origin were investigated. The principle findings of this work are:- 1) Optimisation of clinical investigationsPhotodiode sensitivity of the scanning laser Doppler flowmeter should be kept within a range of 70-150 DC when acquiring images of the retina and optic nerve head in order to optimise the reproducibility of capillary blood flow measures. Account of the physiological spatial variation in retinal blood flow measures can be made using standard analysis protocols of the scanning laser Doppler flowmeter combined with a local search strategy. Measurements of pulsatile ocular blood flow using the ocular blood flow analyser are reproducible, however this reproducibility can be improved when consecutive intraocular pressure pulses are used to calculate pulsatile ocular blood flow. Spectral analysis of the intraocular pressure pulse-wave is viable and identifies the first four harmonic components of the waveform. 2) Physiological variation in ocular perfusionAge results in a significant reduction in perfusion of the retinal microcirculation, which is not evident in larger vessel beds such as the choroid. Despite known asymmetry in the systemic vasculature, no evidence of interocular asymmetry in ocular perfusion is apparent. 3) Pathological variation in ocular perfusionIn primary open angle glaucoma, perfusion is reduced in the retinal microcirculation of patients classified as having early to moderate visual field defects. However, ocular pulsatility defects are masked when patients and subjects are matched for systemic variables (pulse rate and mean arterial pressure); differentiation is facilitated by the application of waveform analysis to the continuos intraocular pressure curve even in the early stages of disease. Diabetic patients with adequate glycaemic control, exhibit maintenance of macular blood flow, macular topography and visual function following phacoemulsification.
Resumo:
The aim of this study was to investigate the agreement between diagnoses of calcified atheroma seen on panoramic radiographs and color Doppler images. Our interest stems from the fact that panoramic images can show the presence of atheroma regardless of the level of obstruction detected by color Doppler images. Panoramic and color Doppler images of 16 patients obtained from the archives of the Health Department of the city of Valença, RJ, Brazil, were analyzed in this study. Both sides of each patient were observed on the images, with a total of 32 analyzed cervical regions. The level of agreement between diagnoses was analyzed using the Kappa statistics. There was a high level of agreement, with a Kappa value of 0.78. In conclusion, panoramic radiographs can help detecting calcifications in the cervical region of patients susceptible to vascular diseases predisposing to myocardial infarction and cerebrovascular accidents. If properly trained and informed, dentists can refer their patients to a physician for a cardiovascular evaluation in order to receive proper and timely medical treatment.
Resumo:
Left ventricular diastolic dysfunction plays an important role on heart failure progression. In order to obtain additional reference values of left ventricular diastolic parameters and investigate influence of common variables, peak E wave (peak E), peak A wave (peak A), E/A ratio (E/A), E wave deceleration time (EDT) and isovolumic relaxation time (IRVT) were studied in 40 clinically healthy dogs, by pulsed wave Doppler. The following values were obtained: peak E = 0.747 ± 0.117 m/s, peak A = 0.487 ± 0.062 m/s, E/A = 1.533 ± 0.198, EDT = 88.7 ± 9.2 ms and IRVT = 0.080 ± 0.009 s. Some parameters were influenced by heart rate (peak E, peak A and IRVT), by age (peak A and E/A) and by body weight (TRIV). Gender influence was absent. Values obtained can be used as reference for canine specimens but its interpretation should consider on the influence of related variables.
Resumo:
Foram comparados dois métodos não-invasivos de medida da pressão arterial, o Doppler vascular e o oscilométrico, com o objetivo de estabelecer parâmetros que possam auxiliar no diagnóstico seguro da hipertensão arterial. Para tal, foram utilizados 45 cães, machos e fêmeas, distribuídos em três grupos de acordo com o peso, pequeno, médio e grande porte. Em cada animal, procedeu-se a mensuração por meio do Doppler vascular e, em seguida, do oscilométrico. Na obtenção da pressão arterial sistólica, não houve diferença entre os métodos nos três grupos de animais, porém, na obtenção da pressão arterial diastólica, houve diferença estatística entre o Doppler vascular e o oscilométrico nos grupos de animais de pequeno e médio porte. Pôde-se concluir que valores confiáveis de pressão sistólica podem ser obtidos tanto por meio do Doppler vascular quanto do oscilométrico. Os valores da pressão arterial diastólica obtidos pelos dois métodos não se correlacionam, principalmente nos animais de pequeno e médio porte.
Resumo:
Avaliaram-se com Doppler pulsátil os fluxos das valvas aórtica (AO) e pulmonar (Pul) por meio de análise qualitativa (presença de regurgitações valvares e características do espectro avaliado) e quantitativa, com obtenção de parâmetros ecocardiográficos como velocidades máxima (V. Max.) e média (V. Me.), integral de velocidade (VTI), tempo de aceleração (TA) e ejeção (TE), de 30 cães considerados clinicamente sadios por meio de exames físico, laboratoriais, eletrocardiográfico, ecocardiográfico (modos uni e bidimensional), radiográfico de tórax e mensuração da pressão arterial sistêmica. Obtiveram-se os seguintes resultados para os referidos parâmetros: V.max. AO= 1,22± 19,38m/s; V. Me. AO= 0,72± 0,08m/s; VTI AO= 0,14± 0,02m; TA AO= 38,80± 11,29ms; TE AO= 197,90± 24,77ms; V. Max. Pul= 0,95± 0,18m/s; V. Me. Pul= 0,63± 0,10m/s; VTI Pul= 0,13± 0,02m; TA Pul= 70,97± 18,87ms; TE Pul= 203,70± 28,98ms. Em apenas três animais observou-se regurgitação pulmonar. Alguns parâmetros apresentaram correlação negativa com a variável freqüência cardíaca (VTI AO, TE AO, VTI Pul, TA Pul, TE Pul); outros correlação positiva com a variável peso (VTI AO, TA AO, TE AO, VTI Pul, TE Pul,) e não se observou influência da variável sexo na maioria dos parâmetros avaliados. Na comparação entre os dois fluxos, observaram-se V. Max. AO e V. Me. AO maiores que V. Max. Pul. e V. Me. Pul., respectivamente, VTI AO maior que VTI Pul, e TA AO menor que TA Pul.
Resumo:
Objectives: To evaluate the intratumoral reliability of color Doppler parameters and the contribution of Doppler sonography to the gray-scale differential diagnosis of ovarian masses. Methods: An observational study was performed including 67 patients, 15 (22.4%) with malignant ovarian neoplasm and 52 (77.6%) with benign ovarian diseases. We performed the Doppler evaluation in two distinct vessels selected after decreasing the Doppler gain to sample only vessels with higher velocity flow. Doppler measurements were obtained from each identified vessel, and resistive index (RI), pulsatility index (PI), peak systolic velocity (PSV), and end-diastolic velocity (EDV) were measured. Intraclass coefficient of correlation (ICC), sensitivity, specificity, and potential improvement in gray-scale ultrasound performance were calculated. Results: The general ICC were 0.60 (95% CI 0.42- 0.73) for RI, 0.65 (95% CI 0.49- 0.77) for PI, 0.07 (95% CI- 0.17-0.30) for PSV, and 0.19 (95% CI -0.05-0.41) for EDV. The sensitivity and specificity were respectively 84.6% and 86.7% for RI, 69.2% and 93.3% for PI, 80.0% and 65.4% for gray-scale sonography, and 93.3% and 65.4% for gray-scale plus RI (p = 0.013). Conclusions: Gynecologists must be careful in interpreting results from Doppler evaluation of ovarian masses because PSV and EDV present poor intratumoral reliability. The lower RI value, evaluated in at least two distinct sites of the tumor, was able to improve the performance of gray-scale ultrasound in differential diagnosis of ovarian masses.
Resumo:
Doppler images in Balmer, He I, He II and C II lines, and simultaneous I-band photometry of the polar MR Ser are presented and analyzed. The Balmer and Helium Doppler tomograms, of this bright polar at high mass transfer state show the emission from the accretion flow and the heated surface of the companion star. As a result of a comparison between the Doppler tomograms, the ionization structure of the flow could be constrained. The highest ionization region was found in the vicinity of the magnetospheric radius. Photoionization modeling of the accretion column indicates that the Balmer and Helium emission line production in this system can be explained only by the central soft X-ray illumination. The orbital ephemeris of MR Ser has been revised.
Resumo:
Renal diseases are common in older cats. Decreased renal blood flow may be the first sign of dysfunction and can be evaluated by Doppler ultrasound. But previous studies suggest that the resistive index (RI) has a low sensitivity for detecting renal disease. Doppler waveforms of renal and intrarenal arteries demonstrate decreased blood flow before there are any changes in the RI. The purpose of this study was to evaluate the normal Doppler flowmetrics parameters of renal arteries (RAs), interlobar arteries (IAs) and abdominal aorta (AO) in adult healthy, Persian cats. Twenty-five Persian cats (13 females and 12 males with mean age of 30 months and an age range 12-60 months) with normal clinical examinations and biochemical tests and normal systemic blood pressure were given B-mode ultrasonographies in order to exclude all nephropathies, including polycystic kidney disease. All measurements were performed on both kidneys. Both kidneys (n = 50) were examined by color mapping of the renal vasculature. Pulsed Doppler was used to examine both RAs, the IAs at cranial, middle and caudal sites, and the AO. The RI was calculated for all of the vessels. Early systolic acceleration (ESA) of RA and IA was obtained with Doppler spectral analysis. Furthermore, the ratio indices between RA/AO, and IA/RA velocities were calculated. The mean values of peak systolic velocity (PSV) and the diameter for AO were 53.17 +/- 13.46 cm/s and 0.38 +/- 0.08 cm, respectively. The mean RA diameter for all 50 kidneys was 0.15 +/- 0.02 cm. Considering the velocimetric values in both RAs, the mean PSV and RI that were obtained were 41.17 +/- 9.40 cm/s and 0.54 +/- 0.07. The RA had a mean ESA of 1.12 +/- 1.14 m/s(2) and the calculated upper limit of the reference value was 3.40 m/s(2). The mean renal-aortic ratio was 0.828 +/- 0.296. The IA showed PSV and RI values of 32.16 +/- 9.33 cm/s and 0.52 +/- 0.06, respectively. The mean ESA of all IAs was 0.73 +/- 0.61 m/s(2). The calculated upper limit of the reference value was 2.0 m/s(2). The mean renal-interlobar artery ratio was 1.45 +/- 0.57. The RI values obtained in this study were similar to values reported in the literature. Some conditions that lead to a decrease in compliance and to an increase in vascular resistance can affect the Doppler spectral waveforms without changes in RI. To our knowledge, there are no studies that were directed toward to the normal ESA values of the renal vasculature in Persian cats. This study introduced a new ratio between the PSV of the RA and the IA. This index was developed based on the well-known effects of Doppler on the detection of stenosis, regardless of the cause. Further studies are necessary to verify the hemodynamic behavior of this index under pathological conditions in cats as well as the effect of aging, nephropathies and systemic pressure on Doppler velocimetric parameters. (C) 2010 ISFM and AAFP. Published by Elsevier Ltd. All rights reserved.
Resumo:
Objective: To evaluate the impact of systematic use of intraoperative Doppler ultrasound during microsurgical subinguinal varicocele repair. Design: Prospective clinical study. Setting: Andrology laboratory and male infertility section of the urology department of a tertiary care hospital. Patient(s): Two hundred and thirteen men with clinical varicocele. Intervention(s): Subinguinal microsurgical varicocele ligation using an intraoperative vascular Doppler flow detector. Main Outcome Measure(s): Number of veins ligated, lymphatic spared, arteries identified or accidentally ligated. Result(s): A statistically significant greater number of arteries were identified and preserved when intraoperative vascular Doppler was used. In addition, the average number of internal spermatic veins ligated was statistically significantly greater in the same group. Accidental artery ligation occurred in two cases (1.1%) in which the Doppler was not applied. There was no statistically significant difference in number of lymphatics spared between groups. Conclusion(s): Our findings showed that concomitant use of intraoperative vascular Doppler during microsurgical varicocelectomy allows more arterial branches to be preserved, and more internal spermatic veins are likely to be ligated. This device should be considered an attractive tool to improve surgical outcomes and safety. (Fertil Steril (R) 2010; 93: 2396-9. (C)2010 by American Society for Reproductive Medicine.)