1000 resultados para Distillation control


Relevância:

80.00% 80.00%

Publicador:

Resumo:

The main scope of this work is the implementation of an MPC that integrates the control and the economic optimization of the system. The two problems are solved simultaneously through the modification of the control cost function that includes an additional term related to the economic objective. The optimizing MPC is based on a quadratic program (QP) as the conventional MPC and can be solved with the available QP solvers. The method was implemented in an industrial distillation system, and the results show that the approach is efficient and can be used, in several practical cases. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

LOPES, Jose Soares Batista et al. Application of multivariable control using artificial neural networks in a debutanizer distillation column.In: INTERNATIONAL CONGRESS OF MECHANICAL ENGINEERING - COBEM, 19, 5-9 nov. 2007, Brasilia. Anais... Brasilia, 2007

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Polycarbonate (PC) is an important engineering thermoplastic that is currently produced in large industrial scale using bisphenol A and monomers such as phosgene. Since phosgene is highly toxic, a non-phosgene approach using diphenyl carbonate (DPC) as an alternative monomer, as developed by Asahi Corporation of Japan, is a significantly more environmentally friendly alternative. Other advantages include the use of CO2 instead of CO as raw material and the elimination of major waste water production. However, for the production of DPC to be economically viable, reactive-distillation units are needed to obtain the necessary yields by shifting the reaction-equilibrium to the desired products and separating the products at the point where the equilibrium reaction occurs. In the field of chemical reaction engineering, there are many reactions that are suffering from the low equilibrium constant. The main goal of this research is to determine the optimal process needed to shift the reactions by using appropriate control strategies of the reactive distillation system. An extensive dynamic mathematical model has been developed to help us investigate different control and processing strategies of the reactive distillation units to increase the production of DPC. The high-fidelity dynamic models include extensive thermodynamic and reaction-kinetics models while incorporating the necessary mass and energy balance of the various stages of the reactive distillation units. The study presented in this document shows the possibility of producing DPC via one reactive distillation instead of the conventional two-column, with a production rate of 16.75 tons/h corresponding to start reactants materials of 74.69 tons/h of Phenol and 35.75 tons/h of Dimethyl Carbonate. This represents a threefold increase over the projected production rate given in the literature based on a two-column configuration. In addition, the purity of the DPC produced could reach levels as high as 99.5% with the effective use of controls. These studies are based on simulation done using high-fidelity dynamic models.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The purpose of the work reported here was to investigate the application of neural control to a common industrial process. The chosen problem was the control of a batch distillation. In the first phase towards deployment, a complex software simulation of the process was controlled. Initially, the plant was modelled with a neural emulator. The neural emulator was used to train a neural controller using the backpropagation through time algorithm. A high accuracy was achieved with the emulator after a large number of training epochs. The controller converged more rapidly, but its performance varied more widely over its operating range. However, the controlled system was relatively robust to changes in ambient conditions.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A sieve plate distillation column has been constructed and interfaced to a minicomputer with the necessary instrumentation for dynamic, estimation and control studies with special bearing on low-cost and noise-free instrumentation. A dynamic simulation of the column with a binary liquid system has been compiled using deterministic models that include fluid dynamics via Brambilla's equation for tray liquid holdup calculations. The simulation predictions have been tested experimentally under steady-state and transient conditions. The simulator's predictions of the tray temperatures have shown reasonably close agreement with the measured values under steady-state conditions and in the face of a step change in the feed rate. A method of extending linear filtering theory to highly nonlinear systems with very nonlinear measurement functional relationships has been proposed and tested by simulation on binary distillation. The simulation results have proved that the proposed methodology can overcome the typical instability problems associated with the Kalman filters. Three extended Kalman filters have been formulated and tested by simulation. The filters have been used to refine a much simplified model sequentially and to estimate parameters such as the unmeasured feed composition using information from the column simulation. It is first assumed that corrupted tray composition measurements are made available to the filter and then corrupted tray temperature measurements are accessed instead. The simulation results have demonstrated the powerful capability of the Kalman filters to overcome the typical hardware problems associated with the operation of on-line analyzers in relation to distillation dynamics and control by, in effect, replacirig them. A method of implementing estimator-aided feedforward (EAFF) control schemes has been proposed and tested by simulation on binary distillation. The results have shown that the EAFF scheme provides much better control and energy conservation than the conventional feedback temperature control in the face of a sustained step change in the feed rate or multiple changes in the feed rate, composition and temperature. Further extensions of this work are recommended as regards simulation, estimation and EAFF control.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

LOPES, Jose Soares Batista et al. Application of multivariable control using artificial neural networks in a debutanizer distillation column.In: INTERNATIONAL CONGRESS OF MECHANICAL ENGINEERING - COBEM, 19, 5-9 nov. 2007, Brasilia. Anais... Brasilia, 2007

Relevância:

40.00% 40.00%

Publicador:

Resumo:

LOPES, Jose Soares Batista et al. Application of multivariable control using artificial neural networks in a debutanizer distillation column.In: INTERNATIONAL CONGRESS OF MECHANICAL ENGINEERING - COBEM, 19, 5-9 nov. 2007, Brasilia. Anais... Brasilia, 2007

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper concern the development of a stable model predictive controller (MPC) to be integrated with real time optimization (RTO) in the control structure of a process system with stable and integrating outputs. The real time process optimizer produces Optimal targets for the system inputs and for Outputs that Should be dynamically implemented by the MPC controller. This paper is based oil a previous work (Comput. Chem. Eng. 2005, 29, 1089) where a nominally stable MPC was proposed for systems with the conventional control approach where only the outputs have set points. This work is also based oil the work of Gonzalez et at. (J. Process Control 2009, 19, 110) where the zone control of stable systems is studied. The new control for is obtained by defining ail extended control objective that includes input targets and zone controller the outputs. Additional decision variables are also defined to increase the set of feasible solutions to the control problem. The hard constraints resulting from the cancellation of the integrating modes Lit the end of the control horizon are softened,, and the resulting control problem is made feasible to a large class of unknown disturbances and changes of the optimizing targets. The methods are illustrated with the simulated application of the proposed,approaches to a distillation column of the oil refining industry.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In industrial practice, constrained steady state optimisation and predictive control are separate, albeit closely related functions within the control hierarchy. This paper presents a method which integrates predictive control with on-line optimisation with economic objectives. A receding horizon optimal control problem is formulated using linear state space models. This optimal control problem is very similar to the one presented in many predictive control formulations, but the main difference is that it includes in its formulation a general steady state objective depending on the magnitudes of manipulated and measured output variables. This steady state objective may include the standard quadratic regulatory objective, together with economic objectives which are often linear. Assuming that the system settles to a steady state operating point under receding horizon control, conditions are given for the satisfaction of the necessary optimality conditions of the steady-state optimisation problem. The method is based on adaptive linear state space models, which are obtained by using on-line identification techniques. The use of model adaptation is justified from a theoretical standpoint and its beneficial effects are shown in simulations. The method is tested with simulations of an industrial distillation column and a system of chemical reactors.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A novel optimising controller is designed that leads a slow process from a sub-optimal operational condition to the steady-state optimum in a continuous way based on dynamic information. Using standard results from optimisation theory and discrete optimal control, the solution of a steady-state optimisation problem is achieved by solving a receding-horizon optimal control problem which uses derivative and state information from the plant via a shadow model and a state-space identifier. The paper analyzes the steady-state optimality of the procedure, develops algorithms with and without control rate constraints and applies the procedure to a high fidelity simulation study of a distillation column optimisation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In membrane distillation in a conventional membrane module, the enthalpies of vaporisation and condensation are supplied and removed by changes in the temperatures of the feed and permeate streams, respectively. Less than 5% of the feed can be distilled in a single pass, because the potential changes in the enthalpies of the liquid streams are much smaller than the enthalpy of vaporisation. Furthermore, the driving force for mass transfer reduces as the feed stream temperature and vapour pressure fall during distillation. These restrictions can be avoided if the enthalpy of vaporisation is uncoupled from the heat capacities of the feed and permeate streams. A specified distillation can then be effected continuously in a single module. Calculations are presented which estimate the performance of a flat plate unit in which the enthalpy of distillation is supplied and removed by the condensing and boiling of thermal fluids in separate circuits, and the imposed temperature difference is independent of position. Because the mass flux through the membrane is dependent on vapour pressure, membrane distillation is suited to applications with a high membrane temperature. The maximum mass flux in the proposed module geometry is predicted to be 30 kg/m2 per h at atmospheric pressure when the membrane temperature is 65°C. Operation at higher membrane temperatures is predicted to raise the mass flux, for example to 85 kg/m2 per h at a membrane temperature of 100°C. This would require pressurisation to 20 bar to prevent boiling at the heating plate of the feed channel. Pre-pressurisation of the membrane pores and control of the dissolved gas concentrations in the feed and the recyled permeate should be investigated as a means to achieve high temperature membrane distillation without pore penetration and wetting.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

As a thermal separation method, distillation is one of the most important technologies in the chemical industry. Given its importance, it is no surprise that increasing efforts have been made in reducing its energy inefficiencies. A great deal of research is focused in the design and optimization of the Divided-Wall Column. Its applications are still reduced due to distrust of its controllability. Previous references studied the decentralized control of DWC but still few papers deal about Model Predictive Control. In this work we present a decentralized control of both a DWC column along with its equivalent MPC schema.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

It is known that distillation tray efficiency depends on the liquid flow pattern, particularly for large diameter trays. Scale·up failures due to liquid channelling have occurred, and it is known that fitting flow control devices to trays sometirr.es improves tray efficiency. Several theoretical models which explain these observations have been published. Further progress in understanding is at present blocked by lack of experimental measurements of the pattern of liquid concentration over the tray. Flow pattern effects are expected to be significant only on commercial size trays of a large diameter and the lack of data is a result of the costs, risks and difficulty of making these measurements on full scale production columns. This work presents a new experiment which simulates distillation by water cooling. and provides a means of testing commercial size trays in the laboratory. Hot water is fed on to the tray and cooled by air forced through the perforations. The analogy between heat and mass transfer shows that the water temperature at any point is analogous to liquid concentration and the enthalpy of the air is analogous to vapour concentration. The effect of the liquid flow pattern on mass transfer is revealed by the temperature field on the tray. The experiment was implemented and evaluated in a column of 1.2 m. dia. The water temperatures were measured by thennocouples interfaced to an electronic computerised data logging system. The "best surface" through the experimental temperature measurements was obtained by the mathematical technique of B. splines, and presented in tenos of lines of constant temperature. The results revealed that in general liquid channelling is more imponant in the bubbly "mixed" regime than in the spray regime. However, it was observed that severe channelling also occurred for intense spray at incipient flood conditions. This is an unexpected result. A computer program was written to calculate point efficiency as well as tray efficiency, and the results were compared with distillation efficiencies for similar loadings. The theoretical model of Porter and Lockett for predicting distillation was modified to predict water cooling and the theoretical predictions were shown to be similar to the experimental temperature profiles. A comparison of the repeatability of the experiments with an errors analysis revealed that accurate tray efficiency measurements require temperature measurements to better than ± 0.1 °c which is achievable with conventional techniques. This was not achieved in this work, and resulted in considerable scatter in the efficiency results. Nevertheless it is concluded that the new experiment is a valuable tool for investigating the effect of the liquid flow pattern on tray mass transfer.