987 resultados para Distance measuring equipment (DME)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The need for the use of another surveillance system when radar cannot be used is the reason for the development of the Multilateration (MLT) Systems. However, there are many systems that operate in the L-Band (960-1215MHz) that could produce interference between systems. At airports, some interference has been detected between transmissions of MLT systems (1030MHz and 1090MHz) and Distance Measuring Equipment (DME) (960-1215MHz).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Trabalho final de Mestrado para obtenção do grau de Mestre em Engenharia de Electrónica e Telecomunicações

Relevância:

100.00% 100.00%

Publicador:

Resumo:

"Supersedes NBS handbook 45."

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Alliance for Coastal Technologies (ACT) Workshop entitled "Technologies for Measuring Currents in Coastal Environments" was held in Portland, Maine, October 26-28, 2005, with sponsorship by the Gulf of Maine Ocean Observing System (GoMOOS), an ACT partner organization. The primary goals of the event were to summarize recent trends in nearshore research and management applications for current meter technologies, identify how current meters can assist coastal managers to fulfill their regulatory and management objectives, and to recommend actions to overcome barriers to use of the technologies. The workshop was attended by 25 participants representing state and federal environmental management agencies, manufacturers of current meter technologies, and researchers from academic institutions and private industry. Common themes that were discussed during the workshop included 1) advantages and limitations of existing current measuring equipment, 2) reliability and ease of use with each instrument type, 3) data decoding and interpretation procedures, and 4) mechanisms to facilitate better training and guidance to a broad user group. Seven key recommendations, which were ranked in order of importance during the last day of the workshop are listed below. 1. Forums should be developed to facilitate the exchange of information among users and industry: a) On-line forums that not only provide information on specific instruments and technologies, but also provide an avenue for the exchange of user experiences with various instruments (i.e. problems encountered, cautions, tips, advantages, etc). (see References for manufacturer websites with links to application and technical forums at end of report) b) Regional training/meetings for operational managers to exchange ideas on methods for measuring currents and evaluating data. c) Organize mini-meetings or tutorial sessions within larger conference venues. 2. A committee of major stakeholders should be convened to develop common standards (similar to the Institute of Electrical and Electronics Engineers (IEEE) committee) that enable users to switch sensors without losing software or display capabilities. (pdf contains 28 pages)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Energia na Agricultura) - FCA

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents preliminary results of an investigation into the detection of partial discharges on the rise of impulse voltages from a point-to-plane gap in SF6. A parallel RC detection impedance is placed in the earth path of a point. Computer simulations are done to determine the values of R and C that will result in the smallest impulse voltage signal and the largest discharge signal across the detection impedance. These simulations and the experimental work show that the impulse voltage signal can not be sufficiently attenuated during the rise time of the applied voltage impulse using the RC detection impedance alone. An alternative discharge detection method is proposed in which a resonant partial discharge coupler is used. Elimination of noise and the impulse voltage signal can be achieved by shorting the coupler plate to the ground plane in the middle of the disk. However, due to the bandwidth of the measuring equipment and noise from the impulse generator it was not possible to detect discharges on the rising edge of a 1.5s voltage impulse using a coupler shorted in the middle. It was found that for this particular coupler, with no shorting points, and if the rising edge of the voltage impulse is longer than 5us, (10us) PD activity can be detected on the rising edge.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

本文提出的微伽绝对重力仪基于高精度、高稳定的差动干涉仪。详细研究了重力仪的距离测量技术,自由落体运动的距离测量实验表明,本文提出的高精度差动干涉仪可以满足相对不确定度达6.4×10^(-9)的微伽绝对重力仪要求。而且,差动干涉仪比目前广泛应用于绝对重力仪的Mach-Zehnder干涉仪更稳定。

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Recent work has investigated the use of O2 concentration in the intake manifold as a control variable for diesel engines. It has been recognised as a very good indicator of NOX emissions especially during transient operation, however, much of the work is concentrated on estimating the O2 concentration as opposed to measuring it. This work investigates Universal Exhaust Gas Oxygen (UEGO) sensors and their potential to be used for such measurements. In previous work it was shown that these sensors can be operated in a controlled pressure environment such that their response time is of the order 10ms. In this paper, it is shown how the key causes of variation (and therefore potential sources of error) in sensor output, namely, pressure and temperature are largely mitigated by operating the sensors in such an environment. Experiments were undertaken on a representative light duty diesel engine using modified UEGO sensors in the intake and exhaust system. Results from other fast emissions measuring equipment are also shown and it is seen that the UEGO sensors are capable of giving an accurate measurement of O2 and EGR. Copyright © 2013 SAE International.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

利用双目视觉信息系统实现三维空间中运动物体实时跟踪与测距。当运动目标超出视野范围时,可通过控制摄像机云台转动搜索目标。此外,还研究了在摄像头运动情况下,无需重新标定,即可实现运动物体测距的算法。这里,自适应背景建模法与CamShift算法用于实现运动物体的辨识与跟踪。实验结果证明了所提出的算法能够有效地追踪物体,并同时准确地测量它的三维位置。

Relevância:

100.00% 100.00%

Publicador:

Resumo:

介绍了我们研制的激光—CCD摄像机组合定位装置,给出了系统构成和定位原理,分析了这种定位装置的特点。提出了利用P3P实现对该定位装置标定的一种简易方法,该方法的特点是不需要标定摄像机的外参数及使用精密的标定设备,且具有较高的标定精度。最后利用我们设计的误差检测实验方法分析了系统的定位精度。

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Os equipamentos de medição utilizados nos hospitais têm uma função muito importante na deteção e diagnóstico de doenças como é o caso da pressão arterial. Entre esses equipamentos encontram-se os esfigmomanómetros digitais portáteis que são em muitos casos os primeiros a serem utilizados e a fornecerem um primeiro diagnóstico da pressão arterial do doente como é no caso das urgências hospitalares. Para que os diagnósticos prescritos pelos profissionais de saúde - médicos e enfermeiros seja o mais correto é necessário conhecer as condições de trabalho em que se encontram os esfigmomanómetros digitais existentes nas unidades de saúde. Sendo os esfigmomanómetros digitais equipamentos com uma importância relevante na vida do ser humano, estes deveriam fazer parte da lista de equipamentos que estão englobados na metrologia legal, situação que neste momento ainda não foi concretizada e cada hospital toma a decisão espontânea se efetua a calibração ou verificação internamente dos seus esfigmomanómetros digitais. Pretende-se com este trabalho dar a conhecer o estado ao nível dos erros de alguns esfigmomanómetros digitais existentes nos hospitais envolvidos no trabalho e desenvolver um procedimento de verificação interna dos mesmos com auxílio de um manómetro analógico calibrado e um estetoscópio duplo – método de medição auscultatório - e comparar esses resultados com a utilização de um simulador – método de medição oscilométrico.