998 resultados para Dispositivos biomédicos


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A grande diversidade na arquitetura de dispositivos de hardware, aliada aos seus diferentes protocolos de comunicação, tem dificultado a implementação de sistemas que necessitam realizar o acesso a esses dispositivos. Diante dessas diferenças, surge a necessidade de prover o acesso a esses dispositivos de forma transparente. Neste sentido, o presente trabalho propõe um middleware mult entrada e saída para acesso a dispositivos, como forma de abstrair o mecanismo de escrita e leitura de dados em dispositivos de hardware, contribuindo desta forma, para o aumento na produtividade dos sistemas, uma vez que os desenvolvedores estão focados apenas nos seus requisitos funcionais

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The great diversity in the architecture of biomedical devices, coupled with their different communication protocols, has hindered the implementation of systems that need to make access to these devices. Given these differences, the need arises to provide access to such a transparent manner. In this sense, this paper proposes an embedded architecture, service-oriented, for access to biomedical devices, as a way to abstract the mechanism for writing and reading data on these devices, thereby contributing to the increase in quality and productivity of biomedical systems so as to enable that, the focus of the development team of biomedical software, is almost exclusively directed to its functional requirements

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A grande diversidade na arquitetura de dispositivos de hardware, aliada aos seus diferentes protocolos de comunicação, tem dificultado a implementação de sistemas que necessitam realizar o acesso a esses dispositivos. Diante dessas diferenças, surge a necessidade de prover o acesso a esses dispositivos de forma transparente. Neste sentido, o presente trabalho propõe um middleware mult entrada e saída para acesso a dispositivos, como forma de abstrair o mecanismo de escrita e leitura de dados em dispositivos de hardware, contribuindo desta forma, para o aumento na produtividade dos sistemas, uma vez que os desenvolvedores estão focados apenas nos seus requisitos funcionais

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A grande diversidade na arquitetura de dispositivos de hardware, aliada aos seus diferentes protocolos de comunicação, tem dificultado a implementação de sistemas que necessitam realizar o acesso a esses dispositivos. Diante dessas diferenças, surge a necessidade de prover o acesso a esses dispositivos de forma transparente. Neste sentido, o presente trabalho propõe um middleware mult entrada e saída para acesso a dispositivos, como forma de abstrair o mecanismo de escrita e leitura de dados em dispositivos de hardware, contribuindo desta forma, para o aumento na produtividade dos sistemas, uma vez que os desenvolvedores estão focados apenas nos seus requisitos funcionais

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia Biomédica

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Na vanguarda do desenvolvimento tecnológico impõe-se o desenvolvimento de sistemas inovadores capazes de gerar energia eléctrica e de responder às necessidades relativas de miniaturização da nova geração de biodispositivos electrónicos portáteis, sem fios e auto-suficientes. O objectivo deste trabalho consistiu na produção e caracterização de um dispositivo electroquímico (biobateria) de espessura reduzida e flexível, capaz de gerar energia eléctrica a partir de fluidos biológicos, como o sangue ou suor. Parte da investigação incidiu sobre a produção e caracterização da matriz de nano-microfibras de policaprolactona. Esta matriz constitui a base dos dispositivos produzidos. Foi obtida através da técnica de electrofiação, consistindo numa membrana porosa, flexível e com elevada área superficial. Posteriormente, em ambas as faces da membrana foram depositados eléctrodos metálicos pela técnica de evaporação térmica assistida por canhão de electrões. Os estudos realizados, que incluíram a análise do comportamento electroquímico através de voltametria cíclica e espectroscopia de impedância, revelaram que os dispositivos produzidos apresentam um desempenho que depende do tempo de imersão em fluidos biológicos (como o suor), da espessura da membrana assim como dos materiais empregues na formação dos eléctrodos. Por último, procedeu-se à demonstração da aplicabilidade do dispositivo produzido colocando-o sobre pele suada e obtiveram-se valores de tensão e corrente promissores que podem levar à aplicação deste dispositivo em pacemakers, dispositivos biomédicos auto-alimentados, entre outros.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Com a incorporação de conceitos da automação em ambientes hospitalares surge uma série de novos requisitos pertinentes a área médica. Dentre esses requisitos, um que merece destaque é a necessidade do estabelecimento de uma rede de comunicação segura e eficiente entre os elementos do ambiente hospitalar, visto que, os mesmos encontram-se de maneira distribuída. Nesse sentido, existe uma série de protocolos que podem ser utilizados no estabelecimento dessa rede, dentre os quais, um que merece destaque é o PM-AH (Protocolo Multiciclos para Automação Hospitalar) justamente por ser voltado a automatização de ambientes hospitalares tanto no que diz respeito ao cumprimento dos requisitos impostos nesse tipo de ambiente, como pelo fato de ser projetado para funcionar sobre a tecnologia Ethernet, padrão esse que é comumente utilizado pela rede de dados dos hospitais. Em decorrência disso, o presente trabalho aborda uma análise de desempenho comparativa entre redes PM-AH e puramente Ethernet visando atestar a eficiência do primeiro no que diz respeito ao cumprimento dos requisitos impostos pela automação hospitalar

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Titanium is a biomaterial widely employed in biomedical applications (implants, prostheses, valves, stents). Several heat treatments are usually used in order to obtain physical properties required to different applications. This work studied the influence of the heat treatment on microstructure of commercial pure titanium, and their consequences in growth and proliferation of MC3T3-E1 cells. Discs of titanium were treated in different temperatures, and characterized by optical microscopy, image analysis, wettabillity, roughness, hardness and X-ray diffraction. After the heat treatment, significant modifications in these properties were observed. Pattern images of titanium, before and after the cell culture, were compared by overlapping to analyze the influence of microstructure in microstructure and preferences guidance cells. However, in general, titanium discs that showed a higher residual strength also presented an increase of cells numbers on surface

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The titanium and titanium alloys are widely used as biomaterial in biomedical device and so research have been developed aiming to improve and/or better to understand interaction biomaterial/biological environment. The process for manufacturing of this titanium implants usually involves a series of thermal and mechanical processes which have consequence on the final product. The heat treatments are usually used to obtain different properties for each application. In order to understand the influence of these treatments on the biological response of the surface, it was done, in this work, different heat treatments in titanium and analyzed their influence on the morphology, adhesion and proliferation of the pre-osteoblastic cells (MC3T3-E1). For such heat-treated titanium disks were characterized by optical microscopy, contact angle, surface energy, roughness, microhardness, X-ray diffraction and scanning through the techniques (BSE, EDS and EBSD). For the analysis of biological response were tested by MTT proliferation, adhesion by crystal violet and β1 integrin expression by flow cytometry. It was found that the presence of a microstructure very orderly, defined by a chemical attack, cells tend to stretch in the same direction of orientation of the material microstructure. When this order does not happen, the most important factor influencing cell proliferation is the residual stress, indicated by the hardness of the material. This way the disks with the highest level state of residual stress also showed increased cell proliferation

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The incorporate of industrial automation in the medical are requires mechanisms to safety and efficient establishment of communication between biomedical devices. One solution to this problem is the MP-HA (Multicycles Protocol to Hospital Automation) that down a segmented network by beds coordinated by an element called Service Provider. The goal of this work is to model this Service Provider and to do performance analysis of the activities executed by in establishment and maintenance of hospital networks

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Several alloys present the shape memory effect and among them, the equiatomic NiTi alloy, nitinol, is the most important one. It is usually used in several engineering applications and also in biomedical devices, in the fabrication of orthodontic wire, stents and Judet staples. Although a considerable amount of these biomedical devices is utilized in Brazil and a fraction of it is already made here, all nitinol used is bought abroad. Thus, it is important to develop the necessary know-how to fabricate NiTi wire and sheet. It would mean less importation with job creation and wealth generation for the country. In this work nitinol was obtained powder metallurgy from elemental powders of Ti and Ni using uniaxial compression and uniaxial compression followed by isostatic compression. The final densities achieved were determined by the Archimedes method. The precipitation of intermetallic secondary phases was studied and the samples were characterized by metallographic analysis, optical microscopy and X-ray diffraction. Results indicated that 50 hours sintering route showed a low amount of intermetallics, and no trace of unreacted powder. XRD and metallography at room temperature indicated B19’ as the predominant phase, which corresponds to martensite. Although density results showed little dispersion, the most dense sample was compacted under uniaxial compression and presented 4.8 g/cm3, corresponding to 20.84% porosity. Density variation was considered normal to the measurement process and independent of the compaction mode

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study aimed to analyze the biological response of titanium surfaces modified by plasma Ar + N2 + H2. Titanium disks grade II received different surface treatments Ar + N2 + H2 plasma, constituting seven groups including only polished samples used as standard. Before and after treatment the samples were evaluated in terms of topography, crystal structure and wettability, using atomic force microscopy, X-ray diffraction, Raman spectroscopy and testing of the sessile drop, respectively. Rich plasma (PRP) was applied to the surfaces modified in culture plates. Images obtained by scanning electron microscopy of the adhered platelets were analyzed to verify the behavior of platelets in the different experimental conditions. We verified that the adition of H2 on plasma atmosphere resulted in more rough surfaces, with round tops. These surfaces, in contrast to that surfaces treated with high concentration of N2, are less propense to platelet aggregation and, consequently, to the formation of thrombus when applied in biomedical devices.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Com a incorporação de conceitos da automação em ambientes hospitalares surge uma série de novos requisitos pertinentes a área médica. Dentre esses requisitos, um que merece destaque é a necessidade do estabelecimento de uma rede de comunicação segura e eficiente entre os elementos do ambiente hospitalar, visto que, os mesmos encontram-se de maneira distribuída. Nesse sentido, existe uma série de protocolos que podem ser utilizados no estabelecimento dessa rede, dentre os quais, um que merece destaque é o PM-AH (Protocolo Multiciclos para Automação Hospitalar) justamente por ser voltado a automatização de ambientes hospitalares tanto no que diz respeito ao cumprimento dos requisitos impostos nesse tipo de ambiente, como pelo fato de ser projetado para funcionar sobre a tecnologia Ethernet, padrão esse que é comumente utilizado pela rede de dados dos hospitais. Em decorrência disso, o presente trabalho aborda uma análise de desempenho comparativa entre redes PM-AH e puramente Ethernet visando atestar a eficiência do primeiro no que diz respeito ao cumprimento dos requisitos impostos pela automação hospitalar