838 resultados para Displasia facio-aurículo-vertebral
Resumo:
El síndrome de Goldenhar forma parte del espectro de anomalías del primer y segundo arco branquial. Constituye una entidad congénita poco frecuente, caracterizada por la asociación de anomalías oculares, auriculares, mandibulares y vertebrales, y cuya etiología permanece aún desconocida. A continuación describimos el caso de un recién nacido que presenta hallazgos clínicos compatibles, que incluyen la asociación de lipodermoide conjuntival unilateral, apéndices preauriculares, hipoplasia hemifacial e hipoplasia de pabellones auriculares. Así mismo, se hace una breve revisión basada en el conjunto de los casos que hasta el presente han aparecido en la literatura científica.
Resumo:
We report a male child born with complete absence of his external ear, hemifacial microsomia of the right side, high arched palate, a down-turned upper lip and slightly upslanting palpebral fissures. The features were suggestive of facio-auriculo-vertebral spectrum. Investigations showed a tandem duplication of the short arm of one chromosome 10 with apparent breakpoints at p14 and p15. This case extends the list of chromosomal abnormalities associated with the facio-auriculo-vertebral phenotype and also adds useful clinical information to possible trisomy 10p phenotypes.
Resumo:
As anomalias craniofaciais ocasionam comprometimentos estéticos e funcionais com grande impacto na saúde e na integração social da criança, com interferência no desenvolvimento global e social. Das anomalias craniofaciais este estudo abordou as Fissuras Labiopalatinas (FLP) e o Espectro Óculo Aurículo Vertebral (EOAV). As FLP constituem malformações resultantes de falta do fechamento completo dos tecidos que compõe o lábio e o palato. O EOAV, também conhecido como Síndrome de Goldenhar, é uma anomalia congênita de etiologia desconhecida, com manifestação genética variável e de causa bastante heterogênea. Conhecer as habilidades funcionais e o impacto destas no desenvolvimento global de crianças com EOAV e FLP pode otimizar o desenvolvimento de programas de prevenção e intervenção para promover a saúde e a integração social destes indivíduos. Este estudo foi delineado com objetivo de verificar e comparar o desempenho em habilidades funcionais quanto ao desempenho nas áreas de autocuidado, mobilidade, função social e nível de independência entre crianças com EOAV, crianças com FLP e um grupo comparativo, de crianças sem anomalias. O modelo de pesquisa foi observacional descritivo transversal com uma casuística de 39 pais/responsáveis de crianças na faixa etária entre três anos e sete anos e seis meses, de ambos os gêneros. Foram convidados para participar pais/responsáveis de crianças em tratamento no Hospital de Reabilitação de Anomalias Craniofaciais da Universidade e São Paulo (HRAC-USP) os quais foram divididos em três grupos: dois experimentais e um grupo comparativo. O instrumento para coleta dos dados das habilidades funcionais foi o Pediatric Evaluation of Disability Inventory (PEDI), em sua versão adaptada para o português. A avaliação é realizada por meio de entrevista com o cuidador, o qual deve saber informar sobre o desempenho da criança em atividades e tarefas típicas da rotina diária. Os dados foram apresentados por análise descritiva com medidas de tendência central (média aritmética), dispersão (desvio-padrão) e distribuição de frequência, nas variáveis: idades, gênero e nível socioeconômico da família e caracterização da casuística. Para as análises das pontuações bruta e normativa do questionário PEDI no que se refere às habilidades funcionais e a assistência do cuidador nas três áreas de função autocuidado, mobilidade e função social, foi utilizado o teste de variância One Way, e para o teste de normalidade foi utilizado Shapiro Wilk para variável dependente. A análise comparativa foi realizada pelo teste de Kruskal-Wallis, adotando-se o valor de significância de p< 0,05. Os resultados deste estudo na análise comparativa nas habilidades funcionais na mobilidade, houve diferença estatisticamente significante na comparação entre os grupos GC vs GEEOAV, no escore bruto, e entre os grupos GC vs GEEOAV e GC vs GEFLP, no escore normativo.Na assistência do cuidador no autocuidado, houve diferença estatisticamente significante na comparação entre os grupos GC vs GEEOAV, no escore normativo. Na assistência do cuidador na mobilidade, houve diferença estatisticamente significante na comparação entre os grupos GC vs GEEOAV nos escores bruto e normativo.Na assistência do cuidador na função social houve diferença estatisticamente significante na comparação entre os grupos GC vs GEFLP.
Resumo:
A síndrome de Goldenhar é uma anomalia congênita rara, de etiologia ainda desconhecida e caracterizada por uma tríade clássica de alterações oculares, auriculares e vertebrais. FORMA DE ESTUDO: Estudo de série. MATERIAL E MÉTODO: Este trabalho foi realizado com 30 indivíduos portadores da síndrome de Goldenhar regularmente matriculados no HRAC, de ambos os gêneros, com faixa etária variando de 8 a 34 anos de idade. OBJETIVO: foi caracterizar o perfil audiológico dos indivíduos portadores dessa síndrome, garantindo assim um melhor tratamento e orientação para os mesmos, assim como também estabelecer a freqüência do comprometimento auditivo contralateral nos indivíduos com o clássico envolvimento unilateral. A avaliação audiológica do estudo constou de ATL, timpanometria, EOA-T e BERA. RESULTADO: de acordo com os resultados concluímos que 34% (=10) dos indivíduos apresentaram como característica de seu perfil audiológico perda auditiva do tipo sensório-neural mista com grau variando de moderado a profundo (7 uni e 3 bilaterais); 13% (n=4) apresentaram perda do tipo condutiva (bilateralmente) com grau de leve a severo e 3% (n=1) apresentaram ou perda do tipo sensório-neural profundo unilateral. Encontramos 40% (n=12) com audição normal bilateralmente e em 10% (n=3) não foi possível estabelecer a característica do perfil audiológico por utilizarmos como avaliação apenas o BERA como pesquisa de limiar eletrofisiológico. Dos doze (12) indivíduos com malformação de OE unilateral encontramos apenas dois (02) com comprometimento auditivo na orelha contralateral, sendo um do tipo misto de grau severo e um condutivo de grau moderado. Com relação a variável sexo encontramos predominância maior da síndrome de Goldenhar no gênero feminino (57%) do que no masculino (43%), mas considerado estatisticamente sem significância, assim como também o lado anatomicamente afetado, que foi predominantemente o direito.
Resumo:
Fusionless scoliosis surgery is an emerging treatment for idiopathic scoliosis as it offers theoretical advantages over current forms of treatment. Anterior vertebral stapling using a nitinol staple is one such treatment. Despite increasing interest in this technique, little is known about the effects on the spine following insertion, or the mechanism of action of the staple. The aims of this study were threefold; (1) to measure changes in the bending stiffness of a single motion segment following staple insertion, (2) to describe the forces that occur within the staple during spinal movement, and (3) to describe the anatomical changes that occur following staple insertion. Results suggest that staple insertion consistently decreased stiffness in all directions of motion. An explanation for the finding may be found in the outcomes of the strain gauge testing and micro-CT scan. The strain gauge testing showed that once inserted, the staple tips applied a baseline compressive force to the surrounding trabecular bone and vertebral end-plate. This finding would be consistent with the current belief that the clinical effect of the staples is via unilateral compression of the physis. Interestingly however, as each specimen progressed through the five cycles of each test, the baseline load on the staple tips gradually decreased, implying that the force at the staple tip-bone interface was decreasing. We believe that this was likely occurring as a result of structural damage to the trabecular bone and vertebral end-plate by the staple effectively causing ‘loosening’ of the staple. This hypothesis is further supported by the findings of the micro-CT scan. The pictures depict significant trabecular bone and physeal injury around the staple blades. These results suggest that the current hypothesis that stapling modulates growth through physeal compression may be incorrect, but rather the effect occurs through mechanical disruption of the vertebral growth plate.
Resumo:
Thoracoscopic instrumented anterior spinal fusion for adolescent idiopathic scoliosis (AIS) has clinical benefits that include reduced pulmonary morbidity, postoperative pain, and improved cosmesis. However, quantitative data on radiological improvement of vertebral rotation using this method is lacking. This study’s objectives were to measure preoperative and postoperative axial vertebral rotational deformity at the curve apex in endoscopically-treated anterior-instrumented scoliosis patients using CT, and assess the relevance of these findings to clinically measured chest wall rib hump deformity correction. This is the first quantitative CT study to confirm that endoscopic anterior instrumented fusion for AIS substantially improves axial vertebral body rotational deformity at the apex of the curve. The margin of correction of 43% compares favourably with historically published figures of 24% for patients with posterior all-hook-rod constructs. CT measurements correlated significantly to the clinical outcome of rib hump deformity correction.
Resumo:
Top screw pullout occurs when the screw is under too much axial force to remain secure in the vertebral body. In vitro biomechanical pullout tests are commonly done to find the maximum fixation strength of anterior vertebral body screws. Typically, pullout tests are done instantaneously where the screw is inserted and then pulled out immediately after insertion. However, bone is a viscoelastic material so it shows a time dependent stress and strain response. Because of this property, it was hypothesised that creep occurs in the vertebral trabecular bone due to the stress caused by the screw. The objective of this study was therefore to determine whether the axial pullout strength of anterior vertebral body screws used for scoliosis correction surgery changes with time after insertion. This study found that there is a possible relationship between pullout strength and time; however more testing is required as the sample numbers were quite small. The design of the screw is made with the knowledge of the strength it must obtain. This is important to prevent such occurrences as top screw pullout. If the pullout strength is indeed decreased due to creep, the design of the screw may need to be changed to withstand greater forces.
Resumo:
Vertebrplasty involved injecting cement into a fractured vertebra to provide stabilisation. There is clinical evidence to suggest however that vertebroplasty may be assocated with a higher risk of adjacent vertebral fracture; which may be due to the change in material properties of the post-procedure vertebra modifying the transmission of mechanical stresses to adjacent vertebrae.
Resumo:
Osteoporosis is a disease characterized by low bone mass and micro-architectural deterioration of bone tissue, with a consequent increase in bone fragility and susceptibility to fracture. Osteoporosis affects over 200 million people worldwide, with an estimated 1.5 million fractures annually in the United States alone, and with attendant costs exceeding $10 billion dollars per annum. Osteoporosis reduces bone density through a series of structural changes to the honeycomb-like trabecular bone structure (micro-structure). The reduced bone density, coupled with the microstructural changes, results in significant loss of bone strength and increased fracture risk. Vertebral compression fractures are the most common type of osteoporotic fracture and are associated with pain, increased thoracic curvature, reduced mobility, and difficulty with self care. Surgical interventions, such as kyphoplasty or vertebroplasty, are used to treat osteoporotic vertebral fractures by restoring vertebral stability and alleviating pain. These minimally invasive procedures involve injecting bone cement into the fractured vertebrae. The techniques are still relatively new and while initial results are promising, with the procedures relieving pain in 70-95% of cases, medium-term investigations are now indicating an increased risk of adjacent level fracture following the procedure. With the aging population, understanding and treatment of osteoporosis is an increasingly important public health issue in developed Western countries. The aim of this study was to investigate the biomechanics of spinal osteoporosis and osteoporotic vertebral compression fractures by developing multi-scale computational, Finite Element (FE) models of both healthy and osteoporotic vertebral bodies. The multi-scale approach included the overall vertebral body anatomy, as well as a detailed representation of the internal trabecular microstructure. This novel, multi-scale approach overcame limitations of previous investigations by allowing simultaneous investigation of the mechanics of the trabecular micro-structure as well as overall vertebral body mechanics. The models were used to simulate the progression of osteoporosis, the effect of different loading conditions on vertebral strength and stiffness, and the effects of vertebroplasty on vertebral and trabecular mechanics. The model development process began with the development of an individual trabecular strut model using 3D beam elements, which was used as the building block for lattice-type, structural trabecular bone models, which were in turn incorporated into the vertebral body models. At each stage of model development, model predictions were compared to analytical solutions and in-vitro data from existing literature. The incremental process provided confidence in the predictions of each model before incorporation into the overall vertebral body model. The trabecular bone model, vertebral body model and vertebroplasty models were validated against in-vitro data from a series of compression tests performed using human cadaveric vertebral bodies. Firstly, trabecular bone samples were acquired and morphological parameters for each sample were measured using high resolution micro-computed tomography (CT). Apparent mechanical properties for each sample were then determined using uni-axial compression tests. Bone tissue properties were inversely determined using voxel-based FE models based on the micro-CT data. Specimen specific trabecular bone models were developed and the predicted apparent stiffness and strength were compared to the experimentally measured apparent stiffness and strength of the corresponding specimen. Following the trabecular specimen tests, a series of 12 whole cadaveric vertebrae were then divided into treated and non-treated groups and vertebroplasty performed on the specimens of the treated group. The vertebrae in both groups underwent clinical-CT scanning and destructive uniaxial compression testing. Specimen specific FE vertebral body models were developed and the predicted mechanical response compared to the experimentally measured responses. The validation process demonstrated that the multi-scale FE models comprising a lattice network of beam elements were able to accurately capture the failure mechanics of trabecular bone; and a trabecular core represented with beam elements enclosed in a layer of shell elements to represent the cortical shell was able to adequately represent the failure mechanics of intact vertebral bodies with varying degrees of osteoporosis. Following model development and validation, the models were used to investigate the effects of progressive osteoporosis on vertebral body mechanics and trabecular bone mechanics. These simulations showed that overall failure of the osteoporotic vertebral body is initiated by failure of the trabecular core, and the failure mechanism of the trabeculae varies with the progression of osteoporosis; from tissue yield in healthy trabecular bone, to failure due to instability (buckling) in osteoporotic bone with its thinner trabecular struts. The mechanical response of the vertebral body under load is highly dependent on the ability of the endplates to deform to transmit the load to the underlying trabecular bone. The ability of the endplate to evenly transfer the load through the core diminishes with osteoporosis. Investigation into the effect of different loading conditions on the vertebral body found that, because the trabecular bone structural changes which occur in osteoporosis result in a structure that is highly aligned with the loading direction, the vertebral body is consequently less able to withstand non-uniform loading states such as occurs in forward flexion. Changes in vertebral body loading due to disc degeneration were simulated, but proved to have little effect on osteoporotic vertebra mechanics. Conversely, differences in vertebral body loading between simulated invivo (uniform endplate pressure) and in-vitro conditions (where the vertebral endplates are rigidly cemented) had a dramatic effect on the predicted vertebral mechanics. This investigation suggested that in-vitro loading using bone cement potting of both endplates has major limitations in its ability to represent vertebral body mechanics in-vivo. And lastly, FE investigation into the biomechanical effect of vertebroplasty was performed. The results of this investigation demonstrated that the effect of vertebroplasty on overall vertebra mechanics is strongly governed by the cement distribution achieved within the trabecular core. In agreement with a recent study, the models predicted that vertebroplasty cement distributions which do not form one continuous mass which contacts both endplates have little effect on vertebral body stiffness or strength. In summary, this work presents the development of a novel, multi-scale Finite Element model of the osteoporotic vertebral body, which provides a powerful new tool for investigating the mechanics of osteoporotic vertebral compression fractures at the trabecular bone micro-structural level, and at the vertebral body level.
Resumo:
Fusionless scoliosis surgery is an emerging treatment for idiopathic scoliosis as it offers theoretical advantages over current forms of treatment. Currently the treatment options for idiopathic scoliosis are observation, bracing and fusion. While brace treatment is non-invasive, and preserves the growth, motion, and function of the spine, it does not correct deformity and is only modestly successful in preventing curve progression. In adolescents who fail brace treatment, surgical treatment with an instrumented spinal fusion usually results in better deformity correction but is associated with substantially greater risk. Furthermore in younger patients requiring surgical treatment, fusion procedures are known to adversely effect the future growth of the chest and spine. Fusionless treatments have been developed to allow effective surgical treatment of patients with idiopathic scoliosis who are too young for fusion procedures. Anterior vertebral stapling is one such fusionless treatment which aims to modulate the growth of vertebra to allow correction of scoliosis whilst maintaining normal spinal motion The Mater Misericordiae Hospital in Brisbane has begun to use anterior vertebral stapling to treat patients with idiopathic scoliosis who are too young for fusion procedures. Currently the only staple approved for clinical use is manufactured by Medtronic Sofamor Danek (Memphis, TN). This thesis explains the biomechanical and anatomical changes that occur following anterior vertebral staple insertion using in vitro experiments performed on an immature bovine model. Currently there is a paucity of published information about anterior vertebral stapling so it is hoped that this project will provide information that will aid in our understanding of the clinical effects of staple insertion. The aims of this experimental study were threefold. The first phase was designed to determine the changes in the bending stiffness of the spine following staple insertion. The second phase was designed to measure the forces experienced by the staple during spinal movements. The third and final phase of testing was designed to describe the structural changes that occur to a vertebra as a consequence of staple insertion. The first phase of testing utilised a displacement controlled testing robot to compare the change in stiffness of a single spinal motion segment following staple insertion for the three basic spinal motions of flexion-extension, lateral bending, and axial rotation. For the second phase of testing strain gauges were attached to staples and used to measure staple forces during spinal movement. In the third and final phase the staples were removed and a testing specimen underwent micro-computed tomography (CT) scanning to describe the anatomical changes that occur following staple insertion. The displacement controlled testing showed that there was a significant decrease in bending stiffness in flexion, extension, lateral bending away from the staple, and axial rotation away from the staple following staple insertion. The strain gauge measurements showed that the greatest staple forces occurred in flexion and the least in extension. In addition, a reduction in the baseline staple compressive force was seen with successive loading cycles. Micro-CT scanning demonstrated that significant damage to the vertebral body and endplate occurred as a consequence of staple insertion. The clinical implications of this study are significant. Based on the findings of this project it is likely that the clinical effect of the anterior vertebral staple evaluated in this project is a consequence of growth plate damage (also called hemiepiphysiodesis) causing a partial growth arrest of the vertebra rather than simply compression of the growth plate. The surgical creation of a unilateral growth arrest is a well established treatment used in the management of congenital scoliosis but has not previously been considered for use in idiopathic scoliosis.
Resumo:
Osteoporotic spinal fractures are a major concern in ageing Western societies. This study develops a multi-scale finite element (FE) model of the osteoporotic lumbar vertebral body to study the mechanics of vertebral compression fracture at both the apparent (whole vertebral body) and micro-structural (internal trabecular bone core)levels. Model predictions were verified against experimental data, and found to provide a reasonably good representation of the mechanics of the osteoporotic vertebral body. This novel modelling methodology will allow detailed investigation of how trabecular bone loss in osteoporosis affects vertebral stiffness and strength in the lumbar spine.
Resumo:
Osteoporosis is the most common bone disease. Low levels of oestrogens or testosterone are risk factors for primary osteoporosis. The most common cause of secondary osteoporosis is glucocorticoid treatment, but there are many other secondary causes of osteoporosis. Osteoporosis can be secondary to anti-oestrogen treatment for hormone-sensitive breast cancer and to androgen-deprivation therapy for prostate cancer. Zoledronic is the most potent bisphosphonate at inhibiting bone resorption. In osteoporosis, zoledronic acid increases bone mineral density for at least a year after a single intravenous administration. The efficacy and safety of extended release (once-yearly) zoledronic acid in the treatment of osteoporosis is reviewed.
Resumo:
Background: Fusionless scoliosis surgery is an early-stage treatment for idiopathic scoliosis which claims potential advantages over current fusion-based surgical procedures. Anterior vertebral stapling using a shape memory alloy staple is one such approach. Despite increasing interest in this technique, little is known about the effects on the spine following insertion, or the mechanism of action of the staple. The purpose of this study was to investigate the biomechanical consequences of staple insertion in the anterior thoracic spine, using in vitro experiments on an immature bovine model. Methods: Individual calf spine thoracic motion segments were tested in flexion, extension, lateral bending and axial rotation. Changes in motion segment rotational stiffness following staple insertion were measured on a series of 14 specimens. Strain gauges were attached to three of the staples in the series to measure forces transmitted through the staple during loading. A micro-CT scan of a single specimen was performed after loading to qualitatively examine damage to the vertebral bone caused by the staple. Findings: Small but statistically significant decreases in bending stiffness occurred in flexion,extension, lateral bending away from the staple, and axial rotation away from the staple. Each strain-gauged staple showed a baseline compressive loading following insertion which was seen to gradually decrease during testing. Post-test micro-CT showed substantial bone and growth plate damage near the staple. Interpretation: Based on our findings it is possible that growth modulation following staple insertion is due to tissue damage rather than sustained mechanical compression of the motion segment.