1000 resultados para Disinfection methods


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Developing countries are heavily burdened by limited access to safe drinking water and subsequent water-related diseases. Numerous water treatment interventions combat this public health crisis, encompassing both traditional and less-common methods. Of these, water disinfection serves as an important means to provide safe drinking water. Existing literature discusses a wide range of traditional treatment options and encourages the use of multi-barrier approaches including coagulation-flocculation, filtration, and disinfection. Most sources do not delve into approaches specifically appropriate for developing countries, nor do they exclusively examine water disinfection methods.^ The objective of this review is to focus on an extensive range of chemical, physio-chemical, and physical water disinfection techniques to provide a compilation, description and evaluation of options available. Such an objective provides further understanding and knowledge to better inform water treatment interventions and explores alternate means of water disinfection appropriate for developing countries. Appropriateness for developing countries corresponds to the effectiveness of an available, easy to use disinfection technique at providing safe drinking water at a low cost.^ Among chemical disinfectants, SWS sodium hypochlorite solution is preferred over sodium hypochlorite bleach due to consistent concentrations. Tablet forms are highly recommended chemical disinfectants because they are effective and very easy to use, but also because they are stable. Examples include sodium dichloroisocyanurate, calcium hypochlorite, and chlorine dioxide, which vary in cost depending on location and availability. Among physio-chemical disinfection options, electrolysis which produces mixed oxidants (MIOX) provides a highly effective disinfection option with a higher upfront cost but very low cost over the long term. Among physical disinfection options, solar disinfection (SODIS) applications are effective, but they treat only a fixed volume of water at a time. They come with higher initial costs but very low on-going costs. Additional effective disinfection techniques may be suitable depending on the location, availability and cost.^

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Purpose: The purpose of this study was to evaluate, in vitro, the contamination of toothbrushes and pacifiers by Streptococcus mutans, and the efficacy of microwave and chlorhexidine for their disinfection. Methods: Sixty pacifiers and 60 toothbrushes were contaminated with S mutans and then divided into groups according to the disinfection protocol: Group 1-chlorhexidine solution; Group 2-microwave sterilization; and Group 3-sterile tap water. The devices were evaluated microbiologically as to the formation of S mutans colonies/biofilms and were examined by scanning electron microscopy. The results were submitted for statistical analysis by Friedman`s test at a 5% significance level. Results: The results of both types of evaluation showed a large number of S mutans colonies/biofilms after spraying with sterile tap water, and chlorhexidine spraying and microwaving were effective in eliminate colonies/biofilms. Groups 1 and 2 were statistically similar to each other (P>.05) and differed significantly from Group 3 (P<.05). Conclusions: The 0.12% chlorhexidine solution spray and 7 minutes of microwave irradiation were effective for disinfection of pacifiers and toothbrushes. (Pediatr Dent 2011;33:10-3) Received July 29, 2009 I Last Revision January 26, 2010 I Accepted March 10, 2010

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Objectives: This study evaluated the effect of disinfection by immersion in sodium perborate (50 degrees C/10 min) or microwave irradiation (650 W/6 min) on the linear dimensional change (LDC) of four reline resins (Kooliner-K, New Truliner-N, Tokuso Rebase Fast-T, Ufi Gel Hard-U) and one heat-polymerizing denture base resin (Lucitone 550-L). Methods: Specimens (50.0 mm diameter, 0.5 mm thickness) were made using a split mold with reference points, and divided into two controls and four test groups (u = 8). The distances between the points were measured on the mold (baseline readings), and compared to those obtained from the specimens after: polymerization or immersion in water (37 degrees C) for 7 days (controls); 2 or 7 cycles of disinfection by immersion or microwave irradiation. Results: the two-way ANOVA and Tukey's test (alpha = 0.05) showed that microwave disinfection significantly increased the mean LDC of materials L (-1.43%), N (-1.27%) and K (-1.06%). Material N also exhibited a significant increase in LDC after two cycles of chemical disinfection (-0.73%). For U (-0.47%) and T (-0.21%) materials, no significant changes in LDC were found. Conclusions: Microwave disinfection increases the shrinkage of materials L, N, and K. The dimensional stability of resins U and T was not affected by the disinfection methods evaluated. (c) 2006 Wiley Periodicals, Inc.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Statement of the problem. In selecting a disinfectant for dental prostheses, compatibility between the disinfectant and the type of denture base material must be considered to avoid adverse effects on the hardness of the acrylic resin.Purpose. This study investigated the hardness of 2 denture base resins after disinfection and long-term water immersion.Material and methods. Thirty-two disk-shaped specimens (13 mm in diameter and 8 mm thick) were fabricated from each resin (Lucitone 550 and QC-20), polished, stored in water at 37degreesC for 48 hours, and submitted to hardness tests (Vickers hardness number [VHN]) before disinfection. Disinfection methods included scrubbing with 4% chlorhexidine gluconate for 1 minute, immersion for 10 minutes in I of the tested disinfectant Solutions (n=8) (3.78% sodium perborate, 4% chlorhexidine gluconate, or 1% sodium hypochorite), and immersion in water for 3 minutes. The disinfection procedures were repeated 4 times, and 12 hardness measurements were made on each specimen. Control specimens (not disinfected) were stored in water for 56 minutes. Hardness tests (VHN) were also performed after 15, 30, 60, 90, and 120 days of storage in water. Statistical analyses of data were conducted with a repeated measures 3-way analysis of variance (ANOVA) and Tukey post-hoc test (alpha=.05).Results. Mean values +/- SD for Lucitone 550 (16.52 +/- 0.94 VHN) and QC-20 (9.61 +/- 0.62 VHN) demonstrated a significant (P<.05) decrease in hardness after disinfection, regardless of material and disinfectant solutions used (Lucitone 550: 15.25 +/- 0.74; QC-20: 8.09 +/- 0.39). However, this effect was reversed after 15 days of storage in water. Both materials exhibited a continuous increase (P<.05) in hardness values for up to 60 days of water storage, after which no significant change was observed.Conclusion. Within the limitations of this in vitro study, QC-20 and Lucitone 550 specimens exhibited significantly lower hardness values after disinfection regardless of the disinfectant solution used.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The purpose of this study was to investigate the effect of thermal cycling and disinfection on the microhardness of acrylic resins denture base. Four different brands of acrylic resins were evaluated: Onda Cryl, QC 20, Classico and Lucitone. Each brand of acrylic resin was divided into four groups (n = 7) according to the disinfection method (microwave, Efferdent, 4% chlorhexidine and 1% hypochlorite). Samples were disinfected during 60 days. Before and after disinfection, samples were thermal cycled between 5-55 °C with 30-s dwell times for 1000 cycles. The microhardness was measured using a microhardener, at baseline (B), after first thermal cycling (T1), after disinfection (D) and after second thermal cycling (T2). The microhardness values of all groups reduced over time. QC-20 acrylic resin exhibited the lowest microhardness values. At B and T1 periods, the acrylic resins exhibited statistically greater microhardness values when compared to D and T2 periods. It can be concluded that the microhardness values of the acrylic resins denture base were affected by the thermal cycling and disinfection procedures. However, all microhardness values obtained herein are within acceptable clinical limits for the acrylic resins. © 2013 Informa UK Ltd.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Työn tarkoitus on löytää paperitehdasintegraatin tuorevesien käsittelyyn kloorikaasun korvaava desinfiointimenetelmä Stora Enso Publication Papers Oy Ltd.:n Anjalan tehtailla. Tehtaalla on ympäristöluvassaan velvoite selvittää mahdollisuudet tuoreveden desinfiointiin käytettävän kaasumaisen kloorin korvaamiseen hypokloriitilla. Kloorikaasun käyttö tehtaalla on työturvallisuusriski, ja jäännösklooripitoisuuksien hallittavuus kloorikaasua käytettäessä on heikko. Työssä tutkittava vesijae on kemiallisesti puhdistettu vesi. Koeajossa käytettävät kemikaalit ovat 10 % natriumhypokloriitti (NaOCl) ja kantaja-aine eli bromikloori- di-metyyli-hydantoiini (BCDMH). Tuloksista voidaan päätellä, että NaOCl:lla ja NaOCl:lla yhdessä BCDMH:n kanssa saavutetaan veden käyttökohteessa korkeammat aktiivisen kloorin jäännöspitoisuudet kuin kloorikaasulla. NaOCl:n ja kaksikomponenttisysteemin käyttökustannukset ovat kuitenkin yli kuusinkertaiset kloorikaasuun verrattuna. NaOCl annosteltuna yhteen pisteeseen olisi vaivattomin menetelmä kloorikaasun korvaamiseen. NaOCl:n annostelulla kahteen pisteeseen voitaisiin saavuttaa korkeampia jäännöspitoisuuksia kuin yhden pisteen annostelulla, mutta menetelmä vaatii lisätutkimuksia. Kaksikomponenttisysteemillä saavutetaan korkeimmat aktiivisen kloorin jäännöspitoisuudet, mutta sen seurantamenetelmien luotettavuudesta tulee varmistua ennen menetelmän käyttöönottoa. Korroosion ehkäisyn ja työturvallisuuden kannalta sekä NaOCl että NaOCl yhdessä BCDMH:n kanssa ovat turvallisempia vaihtoehtoja kuin kaasukloori.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Between August 2006 and February 2007, in the state of Rio de Janeiro, Brazil, a massive outbreak of RGM infections after video laparoscopy was mainly associated to the recently described Mycobacterium massiliense species. All confirmed and probable cases reports described the use of high-level disinfection of medical devices by using 2% glutaraldehyde (2% GA) for 30 min before the surgical procedures. We investigated the susceptibility of the M. massiliense isolates recovered during the outbreak to high-level disinfection after 30 min, 1h, 6h and 10h of exposure to the commercial disinfectants. Reference strains for official mycobactericidal tests such as Mycobacterium abscessus, Mycobacterium bovis, Mycobacterium chelonae, Mycobacterium neoaurum and Mycobacterium smegmatis were included as controls. Although all the reference strains were eliminated in 30 min of exposure to 2% GA, we observed the recovery of all M. massiliense clinical isolates even after 10h of exposure. This study suggests that failures in high-level disinfection and the high tolerance of these M. massiliense clinical strains to the 2% GA were strongly associated to the magnitude of the outbreak.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Brazil has vast amounts of hydric resources, whose quality has been deteriorating due to pollutant dumping. Household waste disposal is one of the main sources of water pollution, stimulating bacteria proliferation and introducing microorganisms, including those from fecal matter. Conventional water disinfection methods are a solution, but on the downside, they lead to the formation byproducts hazardous to human health. In this study, aiming to develop bactericidal filters for the disinfection of drinking water; silver nanoparticles were deposited on alumina foams through three routes: sputtering DC, dip coating and in situ chemical reduction of silver nitrate. The depositions were characterized through X-ray diffraction, scanning electron microscopy and EDS element mapping. The influence of the depositions on permeability and mechanical properties of the ceramic foams was assessed and, in sequence, a preliminary antibacterial efficiency analysis was carried out. Characterization results indicate that the chemical reduction routes were efficient in depositing homogeneously distributed silver particles and that the concentration of the metallic precursor salt affects size and morphology of the particles. The antibacterial efficiency analysis indicates that the chemical reduction filters have potential for water disinfection

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This investigation studied the effects of disinfectant solutions on the hardness of acrylic resin denture teeth. The occlusal surfaces of 64 resin denture teeth were ground flat with abrasives up to 400-grit silicon carbide paper. Measurements were made after polishing and after the specimens were stored in water at 37 degreesC for 48 h. The specimens were then divided into four groups and immersed in chemical disinfectants (4% chlorhexidine; 1% sodium hypochlorite and sodium perborate) for 10 min. The disinfection methods were performed twice to simulate clinical conditions and hardness measurements were made. Specimens tested as controls were immersed in water during the same disinfection time. Eight specimens were produced for each group. After desinfection procedures, testing of hardness was also performed after the samples were stored at 37 degreesC for 7, 30, 60, 90 and 120 days. Data were analysed using two-way analysis of variance (anova) and Tukey's test at 95% confidence level. According to the results, no significant differences were found between materials and immersion solutions (P > 0.05). However, a continuous decrease in hardness was noticed after ageing (P < 0.05). It was conclude that the surfaces of both acrylic resin denture teeth softened upon immersion in water regardless the disinfecting solution.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

STATEMENT OF PROBLEM: Difficulties in sterilizing impressions by traditional methods have led to chemical disinfection as an alternative, and some studies have shown that disinfectants may adversely affect impressions. PURPOSE: This study investigated the effect of disinfection methods on the dimensional stability of 6 elastomeric materials. MATERIAL AND METHODS: Impression materials were submitted to the following treatments: immersion in 5.25% sodium hypochlorite solution for 10 minutes, immersion in 2% glutaraldehyde solution for 30 minutes, and no immersion (control). After treatments, impressions were poured, and respective stone casts were measured with a Nikon Profile projector and compared with the master model. RESULTS: The elastomeric materials had different reproduction capacities, and the disinfecting treatments did not differ from the control.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)