962 resultados para Direct Fourier Method
Resumo:
We present an open-source ITK implementation of a directFourier method for tomographic reconstruction, applicableto parallel-beam x-ray images. Direct Fourierreconstruction makes use of the central-slice theorem tobuild a polar 2D Fourier space from the 1D transformedprojections of the scanned object, that is resampled intoa Cartesian grid. Inverse 2D Fourier transform eventuallyyields the reconstructed image. Additionally, we providea complex wrapper to the BSplineInterpolateImageFunctionto overcome ITKâeuro?s current lack for image interpolatorsdealing with complex data types. A sample application ispresented and extensively illustrated on the Shepp-Loganhead phantom. We show that appropriate input zeropaddingand 2D-DFT oversampling rates together with radial cubicb-spline interpolation improve 2D-DFT interpolationquality and are efficient remedies to reducereconstruction artifacts.
Resumo:
This paper addresses the problem of optimal positioning of surface bonded piezoelectric patches in sandwich plates with viscoelastic core and laminated face layers. The objective is to maximize a set of modal loss factors for a given frequency range using multiobjective topology optimization. Active damping is introduced through co-located negative velocity feedback control. The multiobjective topology optimization problem is solved using the Direct MultiSearch Method. An application to a simply supported sandwich plate is presented with results for the maximization of the first six modal loss factors. The influence of the finite element mesh is analyzed and the results are, to some extent, compared with those obtained using alternative single objective optimization. (C) 2013 Elsevier Ltd. All rights reserved.
Resumo:
This paper addresses the problem of optimal positioning of surface bonded piezoelectric patches in sandwich plates with viscoelastic core and laminated face layers. The objective is to maximize a set of modal loss factors for a given frequency range using multiobjective topology optimization. Active damping is introduced through co-located negative velocity feedback control. The multiobjective topology optimization problem is solved using the Direct MultiSearch Method. An application to a simply supported sandwich plate is presented with results for the maximization of the first six modal loss factors. The influence of the finite element mesh is analyzed and the results are, to some extent, compared with those obtained using alternative single objective optimization.
Resumo:
A multiobjective approach for optimization of passive damping for vibration reduction in sandwich structures is presented in this paper. Constrained optimization is conducted for maximization of modal loss factors and minimization of weight of sandwich beams and plates with elastic laminated constraining layers and a viscoelastic core, with layer thickness and material and laminate layer ply orientation angles as design variables. The problem is solved using the Direct MultiSearch (DMS) solver for derivative-free multiobjective optimization and solutions are compared with alternative ones obtained using genetic algorithms.
Resumo:
The problem of symmetric stability is examined within the context of the direct Liapunov method. The sufficient conditions for stability derived by Fjørtoft are shown to imply finite-amplitude, normed stability. This finite-amplitude stability theorem is then used to obtain rigorous upper bounds on the saturation amplitude of disturbances to symmetrically unstable flows.By employing a virial functional, the necessary conditions for instability implied by the stability theorem are shown to be in fact sufficient for instability. The results of Ooyama are improved upon insofar as a tight two-sided (upper and lower) estimate is obtained of the growth rate of (modal or nonmodal) symmetric instabilities.The case of moist adiabatic systems is also considered.
Resumo:
The purpose of this research project is to study an innovative method for the stability assessment of structural steel systems, namely the Modified Direct Analysis Method (MDM). This method is intended to simplify an existing design method, the Direct Analysis Method (DM), by assuming a sophisticated second-order elastic structural analysis will be employed that can account for member and system instability, and thereby allow the design process to be reduced to confirming the capacity of member cross-sections. This last check can be easily completed by substituting an effective length of KL = 0 into existing member design equations. This simplification will be particularly useful for structural systems in which it is not clear how to define the member slenderness L/r when the laterally unbraced length L is not apparent, such as arches and the compression chord of an unbraced truss. To study the feasibility and accuracy of this new method, a set of 12 benchmark steel structural systems previously designed and analyzed by former Bucknell graduate student Jose Martinez-Garcia and a single column were modeled and analyzed using the nonlinear structural analysis software MASTAN2. A series of Matlab-based programs were prepared by the author to provide the code checking requirements for investigating the MDM. By comparing MDM and DM results against the more advanced distributed plasticity analysis results, it is concluded that the stability of structural systems can be adequately assessed in most cases using MDM, and that MDM often appears to be a more accurate but less conservative method in assessing stability.
Resumo:
Direct sampling methods are increasingly being used to solve the inverse medium scattering problem to estimate the shape of the scattering object. A simple direct method using one incident wave and multiple measurements was proposed by Ito, Jin and Zou. In this report, we performed some analytic and numerical studies of the direct sampling method. The method was found to be effective in general. However, there are a few exceptions exposed in the investigation. Analytic solutions in different situations were studied to verify the viability of the method while numerical tests were used to validate the effectiveness of the method.
Resumo:
Constrained nonlinear optimization problems are usually solved using penalty or barrier methods combined with unconstrained optimization methods. Another alternative used to solve constrained nonlinear optimization problems is the lters method. Filters method, introduced by Fletcher and Ley er in 2002, have been widely used in several areas of constrained nonlinear optimization. These methods treat optimization problem as bi-objective attempts to minimize the objective function and a continuous function that aggregates the constraint violation functions. Audet and Dennis have presented the rst lters method for derivative-free nonlinear programming, based on pattern search methods. Motivated by this work we have de- veloped a new direct search method, based on simplex methods, for general constrained optimization, that combines the features of the simplex method and lters method. This work presents a new variant of these methods which combines the lters method with other direct search methods and are proposed some alternatives to aggregate the constraint violation functions.
Resumo:
When an accurate hydraulic network model is available, direct modeling techniques are very straightforward and reliable for on-line leakage detection and localization applied to large class of water distribution networks. In general, this type of techniques based on analytical models can be seen as an application of the well-known fault detection and isolation theory for complex industrial systems. Nonetheless, the assumption of single leak scenarios is usually made considering a certain leak size pattern which may not hold in real applications. Upgrading a leak detection and localization method based on a direct modeling approach to handle multiple-leak scenarios can be, on one hand, quite straightforward but, on the other hand, highly computational demanding for large class of water distribution networks given the huge number of potential water loss hotspots. This paper presents a leakage detection and localization method suitable for multiple-leak scenarios and large class of water distribution networks. This method can be seen as an upgrade of the above mentioned method based on a direct modeling approach in which a global search method based on genetic algorithms has been integrated in order to estimate those network water loss hotspots and the size of the leaks. This is an inverse / direct modeling method which tries to take benefit from both approaches: on one hand, the exploration capability of genetic algorithms to estimate network water loss hotspots and the size of the leaks and on the other hand, the straightforwardness and reliability offered by the availability of an accurate hydraulic model to assess those close network areas around the estimated hotspots. The application of the resulting method in a DMA of the Barcelona water distribution network is provided and discussed. The obtained results show that leakage detection and localization under multiple-leak scenarios may be performed efficiently following an easy procedure.
Resumo:
In this paper, we assess the relative performance of the direct valuation method and industry multiplier models using 41 435 firm-quarter Value Line observations over an 11 year (1990–2000) period. Results from both pricingerror and return-prediction analyses indicate that direct valuation yields lower percentage pricing errors and greater return prediction ability than the forward price to aggregated forecasted earnings multiplier model. However, a simple hybrid combination of these two methods leads to more accurate intrinsic value estimates, compared to either method used in isolation. It would appear that fundamental analysis could benefit from using one approach as a check on the other.
Resumo:
An improved method for counting virus and virus like particles by electron microscopy (EM) was developed. The procedure involves the determination of the absolute concentration of pure or semi-pure particles once deposited evenly on EM grids using either centrifugation or antibody capture techniques. The counting of particles was done with a Microfiche unit which enlarged approximately 50 x the image of particles on a developed negative film which had been taken at a relatively low magnification (2500 x) by EM. Initially, latex particles of a known concentration were counted using this approach, to prove the accuracy of the technique. The latex particles were deposited evenly on an EM grid using centrifugation (Modified Beckmen EM-90 Airfuge technique). Subsequently, recombinant Bluetongue virus (BTV) core-like particles (CLPs) captured by a Monoclonal antibody using a hovel sample loading method were counted by the Microfiche unit method and by a direct EM method. Comparison of the simplified counting method developed with a conventional method, showed good agreement. The method is simple, accurate, rapid, and reproducible when used with either pure particles or with particles from crude cell culture extracts.
Resumo:
The aim of the present work was to characterize the internal structure of nanogratings generated inside bulk fused silica by ultrafast laser processing and to study the influence of diluted hydrofluoric acid etching on their structure. The nanogratings were inscribed at a depth of 100 mu m within fused silica wafers by a direct writing method, using 1030 nm radiation wavelength and the following processing parameters: E = 5 mu J, tau = 560 fs, f = 10 kHz, and v = 100 mu m/s. The results achieved show that the laser-affected regions are elongated ellipsoids with a typical major diameter of about 30 mu m and a minor diameter of about 6 mu m. The nanogratings within these regions are composed of alternating nanoplanes of damaged and undamaged material, with an average periodicity of 351 +/- 21 nm. The damaged nanoplanes contain nanopores randomly dispersed in a material containing a large density of defects. These nanopores present a roughly bimodal size distribution with average dimensions for each class of pores 65 +/- 20 x 16 +/- 8 x 69 +/- 16 nm(3) and 367 +/- 239 x 16 +/- 8 x 360 +/- 194 nm(3), respectively. The number and size of the nanopores increases drastically when an hydrofluoric acid treatment is performed, leading to the coalescence of these voids into large planar discontinuities parallel to the nanoplanes. The preferential etching of the damaged material by the hydrofluoric acid solution, which is responsible for the pores growth and coalescence, confirms its high defect density. (C) 2014 AIP Publishing LLC.
Resumo:
The physical disector is a method of choice for estimating unbiased neuron numbers; nevertheless, calibration is needed to evaluate each counting method. The validity of this method can be assessed by comparing the estimated cell number with the true number determined by a direct counting method in serial sections. We reconstructed a 1/5 of rat lumbar dorsal root ganglia taken from two experimental conditions. From each ganglion, images of 200 adjacent semi-thin sections were used to reconstruct a volumetric dataset (stack of voxels). On these stacks the number of sensory neurons was estimated and counted respectively by physical disector and direct counting methods. Also, using the coordinates of nuclei from the direct counting, we simulate, by a Matlab program, disector pairs separated by increasing distances in a ganglion model. The comparison between the results of these approaches clearly demonstrates that the physical disector method provides a valid and reliable estimate of the number of sensory neurons only when the distance between the consecutive disector pairs is 60 microm or smaller. In these conditions the size of error between the results of physical disector and direct counting does not exceed 6%. In contrast when the distance between two pairs is larger than 60 microm (70-200 microm) the size of error increases rapidly to 27%. We conclude that the physical dissector method provides a reliable estimate of the number of rat sensory neurons only when the separating distance between the consecutive dissector pairs is no larger than 60 microm.
Resumo:
Currently, there is no simple direct screening method for the misuse of blood transfusions in sports. In this study, we investigated whether the measurement of iron in EDTA-plasma can serve as biomarker for such purpose. Our results revealed an increase of the plasma iron level up to 25-fold 6 h after blood re-infusion. The variable remained elevated 10-fold one day after the procedure. A specificity of 100% and a sensitivity of 93% were obtained with a proposed threshold at 45 µg/dL of plasma iron. Therefore, our test could be used as a simple, cost effective biomarker for the screening for blood transfusion misuse in sports. Copyright © 2014 John Wiley & Sons, Ltd.