The aim of this study was to determine the reproducibility, reliability and validity of measurements in digital models compared to plaster models. Fifteen pairs of plaster models were obtained from orthodontic patients with permanent dentition before treatment. These were digitized to be evaluated with the program Cécile3 v2.554.2 beta. Two examiners measured three times the mesiodistal width of all the teeth present, intercanine, interpremolar and intermolar distances, overjet and overbite. The plaster models were measured using a digital vernier. The t-Student test for paired samples and interclass correlation coefficient (ICC) were used for statistical analysis. The ICC of the digital models were 0.84 ± 0.15 (intra-examiner) and 0.80 ± 0.19 (inter-examiner). The average mean difference of the digital models was 0.23 ± 0.14 and 0.24 ± 0.11 for each examiner, respectively. When the two types of measurements were compared, the values obtained from the digital models were lower than those obtained from the plaster models (p < 0.05), although the differences were considered clinically insignificant (differences < 0.1 mm). The Cécile digital models are a clinically acceptable alternative for use in Orthodontics.
Resumo:
Yardsticks have been developed to measure dental arch relations in cleft lip and palate (CLP) patients as diagnostic proxies for the underlying skeletal relationship. Travelling with plaster casts to compare results between CLP centres is inefficient so the aim of this study was to investigate the reliability of using digital models or photographs of dental casts instead of plaster casts for rating dental arch relationships in children with complete bilateral cleft lip and palate (CBCLP). Dental casts of children with CBCLP (n=20) were included. Plaster casts, digital models and photographs of the plaster casts were available for all the children at 6, 9, and 12 years of age. All three record formats were scored using the bilateral cleft lip and palate (BCLP) yardstick by four observers in random order. No significant differences were found for the BCLP yardstick scores among the three formats. The interobserver weighted kappa scores were between 0.672 and 0.934. Comparison between the formats per observer resulted in weighted kappa scores between 0.692 and 0.885. It is concluded that digital models and photographs of dental casts can be used for rating dental arch relationships in patients with CBCLP. These formats are a reliable alternative for BCLP yardstick assessments on conventional plaster casts.
Resumo:
The aim of this study was to compare standard plaster models with their digital counterparts for the applicability of the Index of Complexity, Outcome, and Need (ICON). Generated study models of 30 randomly selected patients: 30 pre- (T(0)) and 30 post- (T(1)) treatment. Two examiners, calibrated in the ICON, scored the digital and plaster models. The overall ICON scores were evaluated for reliability and reproducibility using kappa statistics and reliability coefficients. The values for reliability of the total and weighted ICON scores were generally high for the T(0) sample (range 0.83-0.95) but less high for the T(1) sample (range 0.55-0.85). Differences in total ICON score between plaster and digital models resulted in mostly statistically insignificant values (P values ranging from 0.07 to 0.19), except for observer 1 in the T(1) sample. No statistically different values were found for the total ICON score on either plaster or digital models. ICON scores performed on computer-based models appear to be as accurate and reliable as ICON scores on plaster models.
Resumo:
Introduction: Le but de l’étude était d’examiner l’effet des matériaux à empreintes sur la précision et la fiabilité des modèles d’études numériques. Méthodes: Vingt-cinq paires de modèles en plâtre ont été choisies au hasard parmi les dossiers de la clinique d’orthodontie de l’Université de Montréal. Une empreinte en alginate (Kromopan 100), une empreinte en substitut d’alginate (Alginot), et une empreinte en PVS (Aquasil) ont été prises de chaque arcade pour tous les patients. Les empreintes ont été envoyées chez Orthobyte pour la coulée des modèles en plâtre et la numérisation des modèles numériques. Les analyses de Bolton 6 et 12, leurs mesures constituantes, le surplomb vertical (overbite), le surplomb horizontal (overjet) et la longueur d’arcade ont été utilisés pour comparaisons. Résultats : La corrélation entre mesures répétées était de bonne à excellente pour les modèles en plâtre et pour les modèles numériques. La tendance voulait que les mesures répétées sur les modèles en plâtre furent plus fiables. Il existait des différences statistiquement significatives pour l’analyse de Bolton 12, pour la longueur d’arcade mandibulaire, et pour le chevauchement mandibulaire, ce pour tous les matériaux à empreintes. La tendance observée fut que les mesures sur les modèles en plâtre étaient plus petites pour l’analyse de Bolton 12 mais plus grandes pour la longueur d’arcade et pour le chevauchement mandibulaire. Malgré les différences statistiquement significatives trouvées, ces différences n’avaient aucune signification clinique. Conclusions : La précision et la fiabilité du logiciel pour l’analyse complète des modèles numériques sont cliniquement acceptables quand on les compare avec les résultats de l’analyse traditionnelle sur modèles en plâtre.
Resumo:
INTRODUCTION The aim of this study was to determine the reproducibility and accuracy of linear measurements on 2 types of dental models derived from cone-beam computed tomography (CBCT) scans: CBCT images, and Anatomodels (InVivoDental, San Jose, Calif); these were compared with digital models generated from dental impressions (Digimodels; Orthoproof, Nieuwegein, The Netherlands). The Digimodels were used as the reference standard. METHODS The 3 types of digital models were made from 10 subjects. Four examiners repeated 37 linear tooth and arch measurements 10 times. Paired t tests and the intraclass correlation coefficient were performed to determine the reproducibility and accuracy of the measurements. RESULTS The CBCT images showed significantly smaller intraclass correlation coefficient values and larger duplicate measurement errors compared with the corresponding values for Digimodels and Anatomodels. The average difference between measurements on CBCT images and Digimodels ranged from -0.4 to 1.65 mm, with limits of agreement values up to 1.3 mm for crown-width measurements. The average difference between Anatomodels and Digimodels ranged from -0.42 to 0.84 mm with limits of agreement values up to 1.65 mm. CONCLUSIONS Statistically significant differences between measurements on Digimodels and Anatomodels, and between Digimodels and CBCT images, were found. Although the mean differences might be clinically acceptable, the random errors were relatively large compared with corresponding measurements reported in the literature for both Anatomodels and CBCT images, and might be clinically important. Therefore, with the CBCT settings used in this study, measurements made directly on CBCT images and Anatomodels are not as accurate as measurements on Digimodels.
Resumo:
This work describes the evolution of temperature measurement in the last four centuries using thermometers based on the thermal expansion of liquids such as ethyl alcohol and mercury. The concept of temperature was strongly dependent on the researcher and there was no systematic temperature scale for universal use. The precursor of the common thermometer was the thermoscope, probably invented at the end of the XVIth century. In the XVIIIth century the instrument was greatly improved and several thermometric scales were proposed some of which have been in use until now. These scales were based on arbitrary points. Mercury and ethyl alcohol were the most employed thermometric fluids. In the XIXth century, the concept of absolute zero was a great advance in this field. The most important contribution during the XXth century was the establishment of international temperature scales. The design of the thermometer has been essentially the same along the last 300 years, but many models were proposed for industrial and research purposes. Its association with the densimeter was of great importance for control of industrial chemical processes and also for teaching purposes in the past. Nowadays, there is a clear tendency to replace mercury-based thermometers by electronic digital models. Thermochemistry is the natural relationship between temperature and chemistry.
Resumo:
Objectif: L'objectif primaire de cette étude était d'évaluer la validité, la fiabilité et la reproductibilité des mesures dentaires obtenues sur les modèles digitaux iTero (Align Technology, San Jose, Californie) et Unitek TMP Digital (3M, Monrovia, Californie) en comparaison avec celles obtenues sur les modèles de plâtre (gold standard). L'objectif secondaire était de comparer les deux différents matériaux à empreinte (l'alginate et le polyvinylsiloxane-PVS) afin de déterminer si le choix du matériau affectait la précision des mesures. Méthodes: Le premier volet de l'étude impliquait les modèles digitaux Unitek et iTero, obtenus à partir de 25 paires de modèles de plâtre choisis de façon randomisée et provenant de la pratique privée d'un des co-auteurs. Des empreintes d'alginate et de PVS ont été prises sur les modèles de plâtre et numérisées par le scanner Unitek. Les modèles ont ensuite été numérisés avec le scanner iTero. Le deuxième volet de l'étude cherchait à comparer les modèles digitaux iTero (numérisation intra-orale) avec les modèles de plâtre (empreintes d'alginate et de PVS) obtenus à partir de 25 patients de la clinique d'orthodontie de l'Université de Montréal ayant besoin d'un traitement orthodontique. Dans les deux volets de l'étude, deux auteurs ont pris les mesures suivantes sur les différents modèles: largeur mésio-distale de chaque dent de la première molaire à l'autre première molaire, le périmètre d'arcade, les distances intermolaire et intercanine, le surplomb vertical et le surplomb horizontal. Les ratios et excès Bolton 6 et 12, l'espace requis et les différentiels d'espace au maxillaire et à la mandibule, ont été calculés. Résultats: La fiabilité (ICC) entre les modèles digitaux (Unitek et iTero) et les modèles de plâtre était bonne à excellente pour toutes les mesures [ICC=0,762–0,998], et la fiabilité entre les deux matériaux à empreinte était excellente [ICC=0,947–0,996]. Dans les deux volets de l'étude, les mesures faites sur les modèles iTero étaient généralement plus grandes que celles faites sur les modèles de plâtre. Les plus grandes différences moyennes pour la comparaison iTero-plâtre étaient trouvées au niveau de l'espace disponible au maxillaire et à la mandibule (systématiquement plus grande pour cette variable), soit 2,24 mm et 2,02 mm respectivement dans le premier volet, et 1,17 mm et 1,39 mm respectivement dans le deuxième volet. Les différences étaient considérées cliniquement non significatives pour toutes les variables. La reproductibilité intra-examinateur était bonne à excellente pour les modèles de plâtre et les modèles digitaux, à l'exception du différentiel d'espace à la mandibule pour les modèles Unitek [ICC=0,690-0,692]. La reproductibilité inter-examinateur était bonne à excellente pour les modèles de plâtre et les modèles digitaux dans les deux volets de l'étude, mais acceptable à modérée pour les modèles Unitek au niveau des analyses Bolton 6 et 12, et des différentiels d'espace au maxillaire et à la mandibule [ICC=0,362-0,548]. Conclusions: La précision et la fiabilité des mesures dentaires faites sur les modèles digitaux Unitek et iTero étaient cliniquement acceptables et reproductibles en comparaison avec les celles faites sur les modèles de plâtre. Le choix de matériel à empreinte entre l'alginate et le PVS n'affectait pas la précision des mesures. Cette étude semble démontrer que les modèles digitaux Unitek et iTero, utilisés avec leur logiciel respectif, sont une alternative fiable et reproductible aux modèles de plâtre pour le diagnostic et l’analyse des modèles orthodontiques.
Resumo:
As digital technologies become widely used in designing buildings and infrastructure, questions arise about their impacts on construction safety. This review explores relationships between construction safety and digital design practices with the aim of fostering and directing further research. It surveys state-of-the-art research on databases, virtual reality, geographic information systems, 4D CAD, building information modeling and sensing technologies, finding various digital tools for addressing safety issues in the construction phase, but few tools to support design for construction safety. It also considers a literature on safety critical, digital and design practices that raises a general concern about ‘mindlessness’ in the use of technologies, and has implications for the emerging research agenda around construction safety and digital design. Bringing these strands of literature together suggests new kinds of interventions, such as the development of tools and processes for using digital models to promote mindfulness through multi-party collaboration on safety
Resumo:
Digital models are an alternative for carrying out analyses and devising treatment plans in orthodontics. The objective of this study was to evaluate the accuracy and the reproducibility of measurements of tooth sizes, interdental distances and analyses of occlusion using plaster models and their digital images. Thirty pairs of plaster models were chosen at random, and the digital images of each plaster model were obtained using a laser scanner (3Shape R-700, 3Shape A/S). With the plaster models, the measurements were taken using a caliper (Mitutoyo Digimatic(®), Mitutoyo (UK) Ltd) and the MicroScribe (MS) 3DX (Immersion, San Jose, Calif). For the digital images, the measurement tools used were those from the O3d software (Widialabs, Brazil). The data obtained were compared statistically using the Dahlberg formula, analysis of variance and the Tukey test (p < 0.05). The majority of the measurements, obtained using the caliper and O3d were identical, and both were significantly different from those obtained using the MS. Intra-examiner agreement was lowest when using the MS. The results demonstrated that the accuracy and reproducibility of the tooth measurements and analyses from the plaster models using the caliper and from the digital models using O3d software were identical.
Resumo:
Durante o processo de projeto, o arquiteto transpõe suas ideias para o campo real, do concreto. Os diversos modos de expressão e representação têm como função mediar essa interação, diminuindo a distância entre esses dois campos. Vive-se hoje, um momento de intensa transformação das estratégias projetuais, propiciadas pelos novos meios digitais. Esta pesquisa tem como objetivo o estudo do uso das representações tridimensionais, especificamente dos modelos físicos e digitais. Pretende-se flagrar os momentos contributivos dos modelos no processo projetivo e as características intrínsecas a eles. A discussão busca não apenas destacar a importância dessa ferramenta, como também, traçar uma breve comparação entre a tecnologia digital e a feitura manual. Para este trabalho foram selecionados alguns arquitetos significativos do cenário da arquitetura paulista em cujos projetos comparecem o uso de modelos. Como estudos de caso tem-se a Residência do arquiteto Marcos Acayaba e o projeto vencedor do Concurso para o Instituto Moreira Salles/ SP, do escritório Andrade Morettin Arquitetos. Soma-se a estes objetivos, a apresentação do uso de modelos físicos e digitais em uma experiência didática projetiva.
Resumo:
The research aims at developing a framework for semantic-based digital survey of architectural heritage. Rooted in knowledge-based modeling which extracts mathematical constraints of geometry from architectural treatises, as-built information of architecture obtained from image-based modeling is integrated with the ideal model in BIM platform. The knowledge-based modeling transforms the geometry and parametric relation of architectural components from 2D printings to 3D digital models, and create large amount variations based on shape grammar in real time thanks to parametric modeling. It also provides prior knowledge for semantically segmenting unorganized survey data. The emergence of SfM (Structure from Motion) provides access to reconstruct large complex architectural scenes with high flexibility, low cost and full automation, but low reliability of metric accuracy. We solve this problem by combing photogrammetric approaches which consists of camera configuration, image enhancement, and bundle adjustment, etc. Experiments show the accuracy of image-based modeling following our workflow is comparable to that from range-based modeling. We also demonstrate positive results of our optimized approach in digital reconstruction of portico where low-texture-vault and dramatical transition of illumination bring huge difficulties in the workflow without optimization. Once the as-built model is obtained, it is integrated with the ideal model in BIM platform which allows multiple data enrichment. In spite of its promising prospect in AEC industry, BIM is developed with limited consideration of reverse-engineering from survey data. Besides representing the architectural heritage in parallel ways (ideal model and as-built model) and comparing their difference, we concern how to create as-built model in BIM software which is still an open area to be addressed. The research is supposed to be fundamental for research of architectural history, documentation and conservation of architectural heritage, and renovation of existing buildings.
Resumo:
Abstract The creation of atlases, or digital models where information from different subjects can be combined, is a field of increasing interest in biomedical imaging. When a single image does not contain enough information to appropriately describe the organism under study, it is then necessary to acquire images of several individuals, each of them containing complementary data with respect to the rest of the components in the cohort. This approach allows creating digital prototypes, ranging from anatomical atlases of human patients and organs, obtained for instance from Magnetic Resonance Imaging, to gene expression cartographies of embryo development, typically achieved from Light Microscopy. Within such context, in this PhD Thesis we propose, develop and validate new dedicated image processing methodologies that, based on image registration techniques, bring information from multiple individuals into alignment within a single digital atlas model. We also elaborate a dedicated software visualization platform to explore the resulting wealth of multi-dimensional data and novel analysis algo-rithms to automatically mine the generated resource in search of bio¬logical insights. In particular, this work focuses on gene expression data from developing zebrafish embryos imaged at the cellular resolution level with Two-Photon Laser Scanning Microscopy. Disposing of quantitative measurements relating multiple gene expressions to cell position and their evolution in time is a fundamental prerequisite to understand embryogenesis multi-scale processes. However, the number of gene expressions that can be simultaneously stained in one acquisition is limited due to optical and labeling constraints. These limitations motivate the implementation of atlasing strategies that can recreate a virtual gene expression multiplex. The developed computational tools have been tested in two different scenarios. The first one is the early zebrafish embryogenesis where the resulting atlas constitutes a link between the phenotype and the genotype at the cellular level. The second one is the late zebrafish brain where the resulting atlas allows studies relating gene expression to brain regionalization and neurogenesis. The proposed computational frameworks have been adapted to the requirements of both scenarios, such as the integration of partial views of the embryo into a whole embryo model with cellular resolution or the registration of anatom¬ical traits with deformable transformation models non-dependent on any specific labeling. The software implementation of the atlas generation tool (Match-IT) and the visualization platform (Atlas-IT) together with the gene expression atlas resources developed in this Thesis are to be made freely available to the scientific community. Lastly, a novel proof-of-concept experiment integrates for the first time 3D gene expression atlas resources with cell lineages extracted from live embryos, opening up the door to correlate genetic and cellular spatio-temporal dynamics. La creación de atlas, o modelos digitales, donde la información de distintos sujetos puede ser combinada, es un campo de creciente interés en imagen biomédica. Cuando una sola imagen no contiene suficientes datos como para describir apropiadamente el organismo objeto de estudio, se hace necesario adquirir imágenes de varios individuos, cada una de las cuales contiene información complementaria respecto al resto de componentes del grupo. De este modo, es posible crear prototipos digitales, que pueden ir desde atlas anatómicos de órganos y pacientes humanos, adquiridos por ejemplo mediante Resonancia Magnética, hasta cartografías de la expresión genética del desarrollo de embrionario, típicamente adquiridas mediante Microscopía Optica. Dentro de este contexto, en esta Tesis Doctoral se introducen, desarrollan y validan nuevos métodos de procesado de imagen que, basándose en técnicas de registro de imagen, son capaces de alinear imágenes y datos provenientes de múltiples individuos en un solo atlas digital. Además, se ha elaborado una plataforma de visualization específicamente diseñada para explorar la gran cantidad de datos, caracterizados por su multi-dimensionalidad, que resulta de estos métodos. Asimismo, se han propuesto novedosos algoritmos de análisis y minería de datos que permiten inspeccionar automáticamente los atlas generados en busca de conclusiones biológicas significativas. En particular, este trabajo se centra en datos de expresión genética del desarrollo embrionario del pez cebra, adquiridos mediante Microscopía dos fotones con resolución celular. Disponer de medidas cuantitativas que relacionen estas expresiones genéticas con las posiciones celulares y su evolución en el tiempo es un prerrequisito fundamental para comprender los procesos multi-escala característicos de la morfogénesis. Sin embargo, el número de expresiones genéticos que pueden ser simultáneamente etiquetados en una sola adquisición es reducido debido a limitaciones tanto ópticas como del etiquetado. Estas limitaciones requieren la implementación de estrategias de creación de atlas que puedan recrear un multiplexado virtual de expresiones genéticas. Las herramientas computacionales desarrolladas han sido validadas en dos escenarios distintos. El primer escenario es el desarrollo embrionario temprano del pez cebra, donde el atlas resultante permite constituir un vínculo, a nivel celular, entre el fenotipo y el genotipo de este organismo modelo. El segundo escenario corresponde a estadios tardíos del desarrollo del cerebro del pez cebra, donde el atlas resultante permite relacionar expresiones genéticas con la regionalización del cerebro y la formación de neuronas. La plataforma computacional desarrollada ha sido adaptada a los requisitos y retos planteados en ambos escenarios, como la integración, a resolución celular, de vistas parciales dentro de un modelo consistente en un embrión completo, o el alineamiento entre estructuras de referencia anatómica equivalentes, logrado mediante el uso de modelos de transformación deformables que no requieren ningún marcador específico. Está previsto poner a disposición de la comunidad científica tanto la herramienta de generación de atlas (Match-IT), como su plataforma de visualización (Atlas-IT), así como las bases de datos de expresión genética creadas a partir de estas herramientas. Por último, dentro de la presente Tesis Doctoral, se ha incluido una prueba conceptual innovadora que permite integrar los mencionados atlas de expresión genética tridimensionales dentro del linaje celular extraído de una adquisición in vivo de un embrión. Esta prueba conceptual abre la puerta a la posibilidad de correlar, por primera vez, las dinámicas espacio-temporales de genes y células.
Resumo:
Prospective estimation of patient CT organ dose prior to examination can help technologist adjust CT scan settings to reduce radiation dose to patient while maintaining certain image quality. One possible way to achieve this is matching patient to digital models precisely. In previous work, patient matching was performed manually by matching the trunk height which was defined as the distance from top of clavicle to bottom of pelvis. However, this matching method is time consuming and impractical in scout images where entire trunk is not included. Purpose of this work was to develop an automatic patient matching strategy and verify its accuracy.
Resumo:
Mestrado em Engenharia Informática. Sistemas Gráficos e Multimédia.
Resumo:
The strengthening of the domestic industry in Brazil required the modernization, mechanization and expansion of salt production. Thereafter the production of sea salt started to be made in a process of continuous flow, where the product is constantly stored in yards, with daily movements in and out of salt. Thus far, the major bottleneck found in this production process is the control of production, because due to the large amount produced and variety of losses existing in the various stages of production there are not a regulated and safe way to control inventories with accuracy and speed demanded. In a typical case with a salt marsh company of Rio Grande do Norte state, salt produced is stored in two open courtyards and inventory control of salt made by carrying input / output relationship of salt in each storage yard. This work developed a conceptual model of inventory control, based on topography, adopting surveys into one of the courtyards of the company. There were 25 biweekly survey measurements over a year book to generate digital models representing the stock. For each measurement, results were compared with the values of inventory accounting provided by the salt marsh in order to identify existing losses and mark out the sales department on the actual stock available at each measurement date. Inventories calculated by the model indicated losses of 6,349 tonnes for the period of one year book and 3,279 tonnes for the period between harvests, when compared to the accounting control