889 resultados para Differential GPS
Resumo:
We used differential GPS measurements from a 13 station GPS network spanning the Santa Ana Volcano and Coatepeque Caldera to characterize the inter-eruptive activity and tectonic movements near these two active and potentially hazardous features. Caldera-forming events occurred from 70-40 ka and at Santa Ana/Izalco volcanoes eruptive activity occurred as recently as 2005. Twelve differential stations were surveyed for 1 to 2 hours on a monthly basis from February through September 2009 and tied to a centrally located continuous GPS station, which serves as the reference site for this volcanic network. Repeatabilities of the averages from 20-minute sessions taken over 20 hours or longer range from 2-11 mm in the horizontal (north and east) components of the inter-station baselines, suggesting a lower detection limit for the horizontal components of any short-term tectonic or volcanic deformation. Repeatabilities of the vertical baseline component range from 12-34 mm. Analysis of the precipitable water vapor in the troposphere suggests that tropospheric decorrelation as a function of baseline lengths and variable site elevations are the most likely sources of vertical error. Differential motions of the 12 sites relative to the continuous reference site reveal inflation from February through July at several sites surrounding the caldera with vertical displacements that range from 61 mm to 139 mm followed by a lower magnitude deflation event on 1.8-7.4 km-long baselines. Uplift rates for the inflationary period reach 300 mm/yr with 1σ uncertainties of +/- 26 – 119 mm. Only one other station outside the caldera exhibits a similar deformation trend, suggesting a localized source. The results suggest that the use of differential GPS measurements from short duration occupations over short baselines can be a useful monitoring tool at sub-tropical volcanoes and calderas.
Resumo:
This work presents the development of low cost microprocessor-based equipment for generation of differential GPS correction signal, in real time, and configuration and supervision of the GPS base. The developed equipment contains a dedicated microcontroller connected to the GPS receiver, alphanumeric display and multifunction keyboard for configuration and operation of the system and communication interfaces. The electronic circuit has the function of receiving the information from GPS base; interpret them, converting the sentence in the RTCM SC-104 protocol. The microcontroller software makes the conversion of the signal received by the GPS base from the specific format to RTCM SC-104 protocol. The processing main board has two serials RS-232C standard interfaces. One of them is used for configuration and receiving the information generated by the GPS base. The other operates as output, sending the differential correction signal for the transmission system. The development of microprocessor-based equipment showed that it is possible the construction of a low cost private station for real time generation of differential GPS correction signal.
Resumo:
OBJECTIVES: To test whether the Global Positioning System (GPS) could be potentially useful to assess the velocity of walking and running in humans. SUBJECT: A young man was equipped with a GPS receptor while walking running and cycling at various velocity on an athletic track. The speed of displacement assessed by GPS, was compared to that directly measured by chronometry (76 tests). RESULTS: In walking and running conditions (from 2-20 km/h) as well as cycling conditions (from 20-40 km/h), there was a significant relationship between the speed assessed by GPS and that actually measured (r = 0.99, P < 0.0001) with little bias in the prediction of velocity. The overall error of prediction (s.d. of difference) averaged +/-0.8 km/h. CONCLUSION: The GPS technique appears very promising for speed assessment although the relative accuracy at walking speed is still insufficient for research purposes. It may be improved by using differential GPS measurement.
Resumo:
PURPOSE: The objective was to explore whether a satellite-based navigation system, global positioning system used in differential mode (DGPS), could accurately assess the speed of running in humans. METHODS: A subject was equipped with a portable GPS receptor coupled to a receiver for differential corrections, while running outdoors on a straight asphalt road at 27 different speeds. Actual speed (reference method) was assessed by chronometry. RESULTS: The accuracy of speed prediction had a standard deviation (SD) of 0.08 km x h(-1) for walking, 0.11 km x h(-1) for running, yielding a coefficient of variation (SD/mean) of 1.38% and 0.82%, respectively. There was a highly significant linear relationship between actual and DGPS speed assessment (r2 = 0.999) with little bias in the prediction equation, because the slope of the regression line was close to unity (0.997). CONCLUSION: the DGPS technique appears to be a valid and inconspicuous tool for "on line" monitoring of the speed of displacement of individuals located on any field on earth, for prolonged periods of time and unlimited distance, but only in specific environmental conditions ("open sky"). Furthermore, the accuracy of speed assessment using the differential GPS mode was improved by a factor of 10 as compared to non-differential GPS.
Resumo:
PURPOSE: This descriptive article illustrates the application of Global Positioning System (GPS) professional receivers in the field of locomotion studies. The technological challenge was to assess the external mechanical work in outdoor walking. METHODS: Five subjects walked five times during 5 min on an athletic track at different imposed stride frequency (from 70-130 steps x min(-1)). A differential GPS system (carrier phase analysis) measured the variation of the position of the trunk at 5 Hz. A portable indirect calorimeter recorded breath-by-breath energy expenditure. RESULTS: For a walking speed of 1.05 +/- 0.11 m x s(-1), the vertical lift of the trunk (43 +/- 14 mm) induced a power of 46.0 +/- 20.4 W. The average speed variation per step (0.15 +/- 0.03 m x s(-1)) produced a kinetic power of 16.9 +/- 7.2 W. As compared with commonly admitted values, the energy exchange (recovery) between the two energy components was low (39.1 +/- 10.0%), which induced an overestimated mechanical power (38.9 +/- 18.3 W or 0.60 W x kg(-1) body mass) and a high net mechanical efficiency (26.9 +/- 5.8%). CONCLUSION: We assumed that the cause of the overestimation was an unwanted oscillation of the GPS antenna. It is concluded that GPS (in phase mode) is now able to record small body movements during human locomotion, and constitutes a promising tool for gait analysis of outdoor unrestrained walking. However, the design of the receiver and the antenna must be adapted to human experiments and a thorough validation study remains to be conducted.
Resumo:
The goal of the this paper is to show that the DGPS data Internet service we designed and developed provides campus-wide real time access to Differential GPS (DGPS) data and, thus, supports precise outdoor navigation. First we describe the developed distributed system in terms of architecture (a three tier client/server application), services provided (real time DGPS data transportation from remote DGPS sources and campus wide data dissemination) and transmission modes implemented (raw and frame mode over TCP and UDP). Then we present and discuss the results obtained and, finally, we draw some conclusions.
Resumo:
In this paper we describe a low cost distributed system intended to increase the positioning accuracy of outdoor navigation systems based on the Global Positioning System (GPS). Since the accuracy of absolute GPS positioning is insufficient for many outdoor navigation tasks, another GPS based methodology – the Differential GPS (DGPS) – was developed in the nineties. The differential or relative positioning approach is based on the calculation and dissemination of the range errors of the received GPS satellites. GPS/DGPS receivers correlate the broadcasted GPS data with the DGPS corrections, granting users increased accuracy. DGPS data can be disseminated using terrestrial radio beacons, satellites and, more recently, the Internet. Our goal is to provide mobile platforms within our campus with DGPS data for precise outdoor navigation. To achieve this objective, we designed and implemented a three-tier client/server distributed system that, first, establishes Internet links with remote DGPS sources and, then, performs campus-wide dissemination of the obtained data. The Internet links are established between data servers connected to remote DGPS sources and the client, which is the data input module of the campus-wide DGPS data provider. The campus DGPS data provider allows the establishment of both Intranet and wireless links within the campus. This distributed system is expected to provide adequate support for accurate outdoor navigation tasks.
Resumo:
The goal of the work presented in this paper is to provide mobile platforms within our campus with a GPS based data service capable of supporting precise outdoor navigation. This can be achieved by providing campus-wide access to real time Differential GPS (DGPS) data. As a result, we designed and implemented a three-tier distributed system that provides Internet data links between remote DGPS sources and the campus and a campus-wide DGPS data dissemination service. The Internet data link service is a two-tier client/server where the server-side is connected to the DGPS station and the client-side is located at the campus. The campus-wide DGPS data provider disseminates the DGPS data received at the campus via the campus Intranet and via a wireless data link. The wireless broadcast is intended for portable receivers equipped with a DGPS wireless interface and the Intranet link is provided for receivers with a DGPS serial interface. The application is expected to provide adequate support for accurate outdoor campus navigation tasks.
Resumo:
The accuracy of the Navigation Satellite Timing and Ranging (NAVSTAR) Global Positioning System (GPS) measurements is insufficient for many outdoor navigation tasks. As a result, in the late nineties, a new methodology – the Differential GPS (DGPS) – was developed. The differential approach is based on the calculation and dissemination of the range errors of the GPS satellites received. GPS/DGPS receivers correlate the broadcasted GPS data with the DGPS corrections, granting users increased accuracy. DGPS data can be disseminated using terrestrial radio beacons, satellites and, more recently, the Internet. Our goal is to provide mobile platforms within our campus with DGPS data for precise outdoor navigation. To achieve this objective, we designed and implemented a three-tier client/server distributed system that establishes Internet links with remote DGPS sources and performs campus-wide dissemination of the obtained data. The Internet links are established between data servers connected to remote DGPS sources and the client, which is the data input module of the campus-wide DGPS data provider. The campus DGPS data provider allows the establishment of both Intranet and wireless links within the campus. This distributed system is expected to provide adequate support for accurate (submetric) outdoor navigation tasks.
Resumo:
Although the Navigation Satellite Timing and Ranging (NAVSTAR) Global Positioning System (GPS) is, de facto, the standard positioning system used in outdoor navigation, it does not provide, per se, all the features required to perform many outdoor navigational tasks. The accuracy of the GPS measurements is the most critical issue. The quest for higher position readings accuracy led to the development, in the late nineties, of the Differential Global Positioning System (DGPS). The differential GPS method detects the range errors of the GPS satellites received and broadcasts them. The DGPS/GPS receivers correlate the DGPS data with the GPS satellite data they are receiving, granting users increased accuracy. DGPS data is broadcasted using terrestrial radio beacons, satellites and, more recently, the Internet. Our goal is to have access, within the ISEP campus, to DGPS correction data. To achieve this objective we designed and implemented a distributed system composed of two main modules which are interconnected: a distributed application responsible for the establishment of the data link over the Internet between the remote DGPS stations and the campus, and the campus-wide DGPS data server application. The DGPS data Internet link is provided by a two-tier client/server distributed application where the server-side is connected to the DGPS station and the client-side is located at the campus. The second unit, the campus DGPS data server application, diffuses DGPS data received at the campus via the Intranet and via a wireless data link. The wireless broadcast is intended for DGPS/GPS portable receivers equipped with an air interface and the Intranet link is provided for DGPS/GPS receivers with just a RS232 DGPS data interface. While the DGPS data Internet link servers receive the DGPS data from the DGPS base stations and forward it to the DGPS data Internet link client, the DGPS data Internet link client outputs the received DGPS data to the campus DGPS data server application. The distributed system is expected to provide adequate support for accurate (sub-metric) outdoor campus navigation tasks. This paper describes in detail the overall distributed application.
Resumo:
A high-resolution three-dimensional (3D) seismic reflection system for small-scale targets in lacustrine settings has been developed. Its main characteristics include navigation and shot-triggering software that fires the seismic source at regular distance intervals (max. error of 0.25 m) with real-time control on navigation using differential GPS (Global Positioning System). Receiver positions are accurately calculated (error < 0.20 m) with the aid of GPS antennas attached to the end of each of three 24-channel streamers. Two telescopic booms hold the streamers at a distance of 7.5 m from each other. With a receiver spacing of 2.5 m, the bin dimension is 1.25 m in inline and 3.75 m in crossline direction. To test the system, we conducted a 3D survey of about 1 km(2) in Lake Geneva, Switzerland, over a complex fault zone. A 5-m shot spacing resulted in a nominal fold of 6. A double-chamber bubble-cancelling 15/15 in(3) air gun (40-650 Hz) operated at 80 bars and 1 m depth gave a signal penetration of 300 m below water bottom and a best vertical resolution of 1.1 m. Processing followed a conventional scheme, but had to be adapted to the high sampling rates, and our unconventional navigation data needed conversion to industry standards. The high-quality data enabled us to construct maps of seismic horizons and fault surfaces in three dimensions. The system proves to be well adapted to investigate complex structures by providing non-aliased images of reflectors with dips up to 30 degrees.
Resumo:
RESUME L'Institut de Géophysique de l'Université de Lausanne a développé au cours de ces dernières années un système d'acquisition de sismique réflexion multitrace à haute résolution 2D et 3D. L'objectif de cette thèse était de poursuivre ce développement tout améliorant les connaissances de la géologie sous le lac Léman, en étudiant en particulier la configuration des grands accidents sous-lacustres dans la Molasse (Tertiaire) qui forme l'essentiel du substratum des formations quaternaires. En configuration 2D, notre système permet d'acquérir des profils sismiques avec une distance inter-CDP de 1,25 m. La couverture varie entre 6 et 18 selon le nombre de traces et la distance inter-tir. Le canon à air (15/15 eu. in.), offre une résolution verticale de 1,25 ni et une pénétration maximale de 300 m sous le fond de l'eau. Nous avons acquis au total plus de 400 km de sections 2D dans le Grand Lac et le Haut Lac entre octobre 2000 et juillet 2004. Une campagne de sismique 3D a fourni des données au large d'Evian sur une surface de 442,5 m sur 1450 m, soit 0,64 km2. La navigation ainsi que le positionnement des hydrophones et de la source ont été réalisés avec des GPS différentiels. Nous avons utilisé un traitement sismique conventionnel, sans appliquer d'AGC et en utilisant une migration post-stack. L'interprétation du substratum antéquaternaire est basée sur l'identification des sismofaciès, sur leurs relations avec les unités géologiques adjacentes au lac, ainsi que sur quelques données de forages. Nous obtenons ainsi une carte des unités géologiques dans le Grand Lac. Nous précisons la position du chevauchement subalpin entre la ville de Lausanne, sur la rive nord, et le bassin de Sciez, sur la rive sud. Dans la Molasse de Plateau, nous avons identifié les décrochements de Pontarlier et de St. Cergue ainsi que plusieurs failles non reconnues jusqu'ici. Nous avons cartographié les accidents qui affectent la Molasse subalpine ainsi que le plan de chevauchement du flysch sur la Molasse près de la rive sud du lac. Une nouvelle carte tectonique de la région lémanique a ainsi pu être dressée. L'analyse du substratum ne montre pas de failles suggérant une origine tectonique de la cuvette lémanique. Par contre, nous suggérons que la forme du creusement glaciaire, donc de la forme du lac Léman, a été influencée par la présence de failles dans le substratum antéquaternaire. L'analyse des sédiments quaternaires nous a permis de tracer des cartes des différentes interfaces ou unités qui les composent. La carte du toit du substratum antéquaternaire montre la présence de chenaux d'origine glaciaire dont la profondeur maximale atteint la cote -200 ni. Leur pente est dirigée vers le nord-est, à l'inverse du sens d'écoulement actuel des eaux. Nous expliquons cette observation par l'existence de circulations sous-glaciaires d'eau artésienne. Les sédiments glaciaires dont l'épaisseur maximale atteint 150 ni au centre du lac ont enregistré les différentes récurrences glaciaires. Dans la zone d'Evian, nous mettons en évidence la présence de lentilles de sédiments glaciolacustres perchées sur le flanc de la cuvette lémanique. Nous avons corrélé ces unités avec des données de forage et concluons qu'il s'agit du complexe inférieur de la pile sédimentaire d'Evian. Celui-ci, âgé de plus de 30 000 ans, serait un dépôt de Kame associé à un lac périglaciaire. La sismique réflexion 3D permet de préciser l'orientation de l'alimentation en matériel détritique de l'unité. La finesse des images obtenues nous permet également d'établir quels types d'érosion ont affecté certaines unités. Les sédiments lacustres, dont l'épaisseur maximale imagée atteint plus de 225 m et sans doute 400 ni sous le delta du Rhône, indiquent plusieurs mécanismes de dépôts. A la base, une mégaturbidite, épaisse d'une trentaine de mètres en moyenne, s'étend entre l'embouchure de la Dranse et le delta du Rhône. Au-dessus, la décantation des particules en suspension d'origine biologique et détritique fournit l'essentiel des sédiments. Dans la partie orientale du lac, les apports détritiques du Rhône forment un delta qui prograde vers l'ouest en s'imbriquant avec les sédiments déposés par décantation. La structure superficielle du delta a brutalement évolué, probablement à la suite de l'évènement catastrophique du Tauredunum (563 A.D.). Sa trace probable se marque par la présence d'une surface érosive que nous avons cartographiée. Le delta a ensuite changé de géométrie, avec notamment un déplacement des chenaux sous-lacustres. Sur l'ensemble de nos sections sismiques, nous n'observons aucune faille dans les sédiments quaternaires qui attesterait d'une tectonique postglaciaire du substratum. ABSTRACT During the last few years the institute of Geophysics of the University of Lausanne cleveloped a 2D and 3D high-resolution multichannel seismic reflection acquisition system. The objective of the present work was to carry on this development white improving our knowledge of the geology under Lake Geneva, in particular by studying the configuration of the large accidents affecting the Tertiary Molasse that makes up the basement of most Quaternary deposits. In its 2D configuration, our system makes it possible to acquire seismic profiles with a CDP interval of 1.25 m. The fold varies from 6 to 18 depending on the number of traces and the shooting interval. Our air gun (15/15 cu. in.) provides a vertical resolution of 1.25 m and a maximum penetration depth of approximately 300 m under water bottom. We acquired more than 400 km of 2D sections in the Grand Lac and the Haut Lac between October 2000 and July 2004. A 3D seismic survey off the city of Evian provided data on a surface of 442.5 m x 1450 m (0.64 km2). Ship's navigation as well as hydrophone- and source positioning were carried out with differential GPS. The seismic data were processed following a conventional sequence without .applying AGC and using post-stack migration. The interpretation of the pre-Quaternary substratum is based on sismofacies, on their relationships with terrestrial geological units and on some borehole data. We thus obtained a map of the geological units in the Grand Lac. We defined the location of the subalpine thrust from Lausanne, on the north shore, to the Sciez Basin, on the south shore. Within the Molasse de Plateau, we identified the already know Pontarlier and St Cergue transforms Fault as well as faults. We mapped faults that affect subalpine Molasse as well as the thrust fault plane between alpine flysch and Molasse near the lake's south shore. A new tectonic map of the Lake Geneva region could thus be drawn up. The substratum does not show faults indicating a tectonic origin for the Lake Geneva Basin. However, we suggest that the orientation of glacial erosion, and thus the shape of Lake Geneva, vas influenced by the presence of faults in the pre-Quaternary basement. The analysis of Quaternary sediments enabled us to draw up maps of various discontinuities or internal units. The top pre-Quaternary basement map shows channels of glacial origin, the deepest of them reaching an altitude of 200 m a.s.l. The channel's slopes are directed to the North-East, in opposite direction of the present water flow. We explain this observation by the presence of artesian subglacial water circulation. Glacial sediments, the maximum thickness of which reaches 150 m in the central part of the lake, record several glacial recurrences. In the Evian area, we found lenses of glacio-lacustrine sediments set high up on the flank of the Lake Geneva Bassin. We correlated these units with on-land borehole data and concluded that they represent the lower complex of the Evian sedimentary pile. The lower complex is aider than 30 000 years, and it could be a Kame deposit associated with a periglacial lake. Our 3D seismic reflexion survey enables us to specify the supply direction of detrital material in this unit. With detailed seismic images we established how some units were affected by different erosion types. The lacustrine sediments we imaged in Lake Geneva are thicker than 225 m and 400 m or more Linder the Rhone Delta. They indicate several depositional mechanisms. Their base is a major turbidite, thirty meters thick on average, that spreads between the Dranse mouth and the Rhone delta. Above this unit, settling of suspended biological and detrital particles provides most of the sediments. In the eastern part of the lake, detrital contribution from the Rhone builds a delta that progrades to the west and imbricates with the settling sediments. The shallow structure of the Rhone delta abruptly evolved, probably after the catastrophic Tauredunum event (563 A.D.). It probably coincides with an erosive surface that we mapped. As a result, the delta geometry changed, in particular associated with a displacement of water bottom channels. In all our seismic sections, we do not observe fault in the Quaternary sediments that would attest postglacial tectonic activity in the basement.
Resumo:
INTRODUCTION: In alpine skiing, chronometry analysis is currently the most common tool to assess performance. It is widely used to rank competitors during races, as well as to manage athletes training and to evaluate material. Usually, this measurement is accurately realized using timing cells. Nevertheless, these devices are too complex and expensive to allow chronometry of every gates crossing. On the other side, differential GPS can be used for measuring gate crossing time (Waegli et al). However, this is complex (e.g. recording gate position with GPS) and mainly used in research applications. The aim of the study was to propose a wearable system to time gates crossing during alpine skiing slalom (SL), which is suitable for routine uses. METHODS: The proposed system was composed of a 3D accelerometer (ADXL320®, Analog Device, USA) placed at the sacrum of the athlete, a matrix of force sensors (Flexiforce®, Tekscan, USA) fixed on the right shin guard and a data logger (Physilog®, BioAGM, Switzerland). The sensors were sampled at 500 Hz. The crossing time were calculated in two phases. First, the accelerometer was used to detect the curves by considering the maximum of the mediolateral peak acceleration. Then, the force sensors were used to detect the impacts with the gates by considering maximum force variation. In case of non impact, the detection was realized based on the acceleration and features measured at the other gates. In order to assess the efficiency of the system, two different SL were monitored twice for two world cup level skiers, a male SL expert and a female downhill expert. RESULTS AND DISCUSSION: The combination of the accelerometer and force sensors allowed to clearly identify the gate crossing times. When comparing the runs of the SL expert and the downhill expert, we noticed that the SL expert was faster. For example for the first SL, the overall difference between the best run of each athlete was of 5.47s. At each gate, the SL expert increased the time difference slower at the beginning (0.27s/gate) than at the end (0.34s/gate). Furthermore, when comparing the runs of the SL expert, a maximum time difference of 20ms at each gate was noticed. This showed high repeatability skills of the SL expert. In opposite, the downhill expert with a maximum difference time of 1s at each gate was clearly less repeatable. Both skiers were not disturbed by the system. CONCLUSION: This study proposed a new wearable system to automatically time gates crossing during alpine skiing slalom combining force and accelerometer sensors. The system was evaluated with two professional world cup skiers and showed a high potential. This system could be extended to time other parameters. REFERENCES Waegli A, Skaloud J (2007). Inside GNSS, Spring, 24-34.