996 resultados para Device Life


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Federal Railroad Administration, Office of Safety, Washington, D.C.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conclusion. The new Provox(R) NID (TM) non- indwelling voice prosthesis investigated in this study provides a good option for laryngectomized patients using non- indwelling voice prostheses and can potentially improve safety and increase patients' satisfaction with their voice and speech. Objective. To investigate the feasibility of and patient satisfaction with the Provox NID non- indwelling voice prosthesis. Material and methods. Pre- and post- study questionnaires were used to evaluate the patients' former voice prosthesis and the Provox NID voice prosthesis. In addition, measurements of pull- out force, maximum phonation time and loudness were made for both voice prostheses. In vitro measurements of airflow characteristics were also made. Following a 6- week trial, all patients provided feedback on the new voice prosthesis and the results were used to further improve the Provox NID. This final version of the new voice prosthesis was subsequently trialled and evaluated by 10 patients 6 months later. Results. Overall results showed that patient satisfaction with the Provox NID non- indwelling voice prosthesis was favourable. The pull- out force for the new prosthesis was significantly higher than that for the formerly used prosthesis and its aerodynamic characteristics were better.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

What is the contribution of the provision, at no cost for users, of long acting reversible contraceptive methods (LARC; copper intrauterine device [IUD], the levonorgestrel-releasing intrauterine system [LNG-IUS], contraceptive implants and depot-medroxyprogesterone [DMPA] injection) towards the disability-adjusted life years (DALY) averted through a Brazilian university-based clinic established over 30 years ago. Over the last 10 years of evaluation, provision of LARC methods and DMPA by the clinic are estimated to have contributed to DALY averted by between 37 and 60 maternal deaths, 315-424 child mortalities, 634-853 combined maternal morbidity and mortality and child mortality, and 1056-1412 unsafe abortions averted. LARC methods are associated with a high contraceptive effectiveness when compared with contraceptive methods which need frequent attention; perhaps because LARC methods are independent of individual or couple compliance. However, in general previous studies have evaluated contraceptive methods during clinical studies over a short period of time, or not more than 10 years. Furthermore, information regarding the estimation of the DALY averted is scarce. We reviewed 50 004 medical charts from women who consulted for the first time looking for a contraceptive method over the period from 2 January 1980 through 31 December 2012. Women who consulted at the Department of Obstetrics and Gynaecology, University of Campinas, Brazil were new users and users switching contraceptive, including the copper IUD (n = 13 826), the LNG-IUS (n = 1525), implants (n = 277) and DMPA (n = 9387). Estimation of the DALY averted included maternal morbidity and mortality, child mortality and unsafe abortions averted. We obtained 29 416 contraceptive segments of use including 25 009 contraceptive segments of use from 20 821 new users or switchers to any LARC method or DMPA with at least 1 year of follow-up. The mean (± SD) age of the women at first consultation ranged from 25.3 ± 5.7 (range 12-47) years in the 1980s, to 31.9 ± 7.4 (range 16-50) years in 2010-2011. The most common contraceptive chosen at the first consultation was copper IUD (48.3, 74.5 and 64.7% in the 1980s, 1990s and 2000s, respectively). For an evaluation over 20 years, the cumulative pregnancy rates (SEM) were 0.4 (0.2), 2.8 (2.1), 4.0 (0.4) and 1.3 (0.4) for the LNG-IUS, the implants, copper IUD and DMPA, respectively and cumulative continuation rates (SEM) were 15.1 (3.7), 3.9 (1.4), 14.1 (0.6) and 7.3 (1.7) for the LNG-IUS, implants, copper IUD and DMPA, respectively (P < 0.001). Over the last 10 years of evaluation, the estimation of the contribution of the clinic through the provision of LARC methods and DMPA to DALY averted was 37-60 maternal deaths; between 315 and 424 child mortalities; combined maternal morbidity and mortality and child mortality of between 634 and 853, and 1056-1412 unsafe abortions averted. The main limitations are the number of women who never returned to the clinic (overall 14% among the four methods under evaluation); consequently the pregnancy rate could be different. Other limitations include the analysis of two kinds of copper IUD and two kinds of contraceptive implants as the same IUD or implant, and the low number of users of implants. In addition, the DALY calculation relies on a number of estimates, which may vary in different parts of the world. LARC methods and DMPA are highly effective and women who were well-counselled used these methods for a long time. The benefit of averting maternal morbidity and mortality, child mortality, and unsafe abortions is an example to health policy makers to implement more family planning programmes and to offer contraceptive methods, mainly LARC and DMPA, at no cost or at affordable cost for the underprivileged population. This study received partial financial support from the Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP), grant # 2012/12810-4 and from the National Research Council (CNPq), grant #573747/2008-3. B.F.B., M.P.G., and V.M.C. were fellows from the scientific initiation programme from FAPESP. Since the year 2001, all the TCu380A IUD were donated by Injeflex, São Paulo, Brazil, and from the year 2006 all the LNG-IUS were donated by the International Contraceptive Access Foundation (ICA), Turku, Finland. Both donations are as unrestricted grants. The authors declare that there are no conflicts of interest associated with this study.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work presents results of preliminary studies concerning application of magnetic bearing in a ventricular assist device (VAD) being developed by Dante Pazzanese Institute of Cardiology-IDPC (Sao Paulo, Brazil). The VAD-IDPC has a novel architecture that distinguishes from other known VADs. In this, the rotor has a conical geometry with spiral impellers, showing characteristics that are intermediate between a centrifugal VAD and an axial VAD. The effectiveness of this new type of blood pumping principle was showed by tests and by using it in heart surgery for external blood circulation. However, the developed VAD uses a combination of ball bearings and mechanical seals, limiting the life for some 10 h, making impossible its long-term use or its use as an implantable VAD. As a part of development of an implantable VAD, this work aims at the replacement of ball bearings by a magnetic bearing. The most important magnetic bearing principles are studied and the magnetic bearing developed by Escola Politecnica of Sao Paulo University (EPUSP-MB) is elected because of its very simple architecture. Besides presenting the principle of the EPUSP-MB, this work presents one possible alternative for applying the EPUSP-MB in the IDPC-VAD.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A large part of power dissipation in a system is generated by I/O devices. Increasingly these devices provide power saving mechanisms to inter alia enhance battery life. While I/O device scheduling has been studied in the past for realtime systems, the use of energy resources by these scheduling algorithms may be improved. These approaches are crafted considering a huge overhead of device transition. The technology enhancement has allowed the hardware vendors to reduce the device transition overhead and energy consumption. We propose an intra-task device scheduling algorithm for real time systems that allows to shut-down devices while ensuring the system schedulability. Our results show an energy gain of up to 90% in the best case when compared to the state-of-the-art.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A large part of power dissipation in a system is generated by I/O devices. Increasingly these devices provide power saving mechanisms, inter alia to enhance battery life. While I/O device scheduling has been studied in the past for realtime systems, the use of energy resources by these scheduling algorithms may be improved. These approaches are crafted considering a very large overhead of device transitions. Technology enhancements have allowed the hardware vendors to reduce the device transition overhead and energy consumption. We propose an intra-task device scheduling algorithm for real time systems that allows to shut-down devices while ensuring system schedulability. Our results show an energy gain of up to 90% when compared to the techniques proposed in the state-of-the-art.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

RésuméL'origine de l'obésité, qui atteint des proportions épidémiques, est complexe. Elle est liée au mode de vie et au comportement des individus par rapport à l'activité physique, expression des choix individuels et de l'interaction avec l'environnement. Les mesures du comportement au niveau de l'activité physique des individus face à leur environnement, la répartition des types d'activité physique, la durée, la fréquence, l'intensité, et la dépense énergétique sont d'une grande importance. Aujourd'hui, il y a un manque de méthodes permettant une évaluation précise et objective de l'activité physique et du comportement des individus. Afin de compléter les recherches relatives à l'activité physique, à l'obésité et à certaines maladies, le premier objectif du travail de thèse était de développer un modèle pour l'identification objective des types d'activité physique dans des conditions de vie réelles et l'estimation de la dépense énergétique basée sur une combinaison de 2 accéléromètres et 1 GPS. Le modèle prend en compte qu'une activité donnée peut être accomplie de différentes façons dans la vie réelle. Les activités quotidiennes ont pu être classées en 8 catégories, de sédentaires à actives, avec une précision de 1 min. La dépense énergétique a pu peut être prédite avec précision par le modèle. Après validation du modèle, le comportement des individus de l'activité physique a été évalué dans une seconde étude. Nous avons émis l'hypothèse que, dans un environnement caractérisé par les pentes, les personnes obèses sont tentées d'éviter les pentes raides et de diminuer la vitesse de marche au cours d'une activité physique spontanée, ainsi que pendant les exercices prescrits et structurés. Nous avons donc caractérisé, par moyen du modèle développé, le comportement des individus obèses dans un environnement vallonné urbain. La façon dont on aborde un environnement valloné dans les déplacements quotidiens devrait également être considérée lors de la prescription de marche supplémentaire afin d'augmenter l'activité physique.SummaryOrigin of obesity, that reached epidemic proportion, is complex and may be linked to different lifestyle and physical activity behaviour. Measurement of physical activity behaviour of individuals towards their environment, the distribution of physical activity in terms of physical activity type, volume, duration, frequency, intensity, and energy expenditure is of great importance. Nowadays, there is a lack of methods for accurate and objective assessment of physical activity and of individuals' physical activity behaviour. In order to complement the research relating physical activity to obesity and related diseases, the first aim of the thesis work was to develop a model for objective identification of physical activity types in real-life condition and energy expenditure based on a combination of 2 accelerometers and 1 GPS device. The model takes into account that a given activity can be achieved in many different ways in real life condition. Daily activities could be classified in 8 categories, as sedentary to active physical activity, within 1 min accuracy, and physical activity patterns determined. The energy expenditure could be predicted accurately with an accuracy below 10%. Furthermore, individuals' physical activity behaviour is expression of individual choices and their interaction with the neighbourhood environment. In a second study, we hypothesized that, in an environment characterized by inclines, obese individuals are tempted to avoid steep positive slopes and to decrease walking speed during spontaneous outdoor physical activity, as well as during prescribed structured bouts of exercise. Finally, we characterized, by mean of the developed model, the physical activity behaviour of obese individuals in a hilly urban environment. Quantifying how one tackles hilly environment or avoids slope in their everyday displacements should be also considered while prescribing extra walking in free-living conditions in order to increase physical activity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Extracorporeal life support systems (ECLS) have become common in cardiothoracic surgery, but are still "Terra Incognita" in other medical fields due to the fact that perfusion units are normally bound to cardiothoracic centres. The Lifebridge B2T is an ECLS that is meant to be used as an easy and fast-track extracorporeal cardiac support to provide short-term perfusion for the transport of a patient to a specialized centre. With the Lifebridge B2T it is now possible to provide extracorporeal bypass for patients in hospitals without a perfusion unit. The Lifebridge B2T was tested on three calves to analyze the handling, performance and security of this system. The Lifebridge B2T safely can be used clinically and can provide full extracorporeal support for patients in cardiac or pulmonary failure. Flows up to 3.9 +/- 0.2l/min were reached, with an inflow pressure of -103 +/- 13mmHg, using a 21Fr. BioMedicus (Medtronic, Minneapolis, MN, USA) venous cannula. The "Plug and Play" philosophy, with semi-automatic priming, integrated check-list, a long battery time of over two hours and instinctively designed user interface, makes this device very interesting for units with high-risk interventions, such as catheterisation labs. If a system is necessary in an emergency unit, the Lifebridge can provide a high security level, even in centres not acquainted with cardiopulmonary bypass.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In jointed portland cement concrete pavements, dowel bars are typically used to transfer loads between adjacent slabs. A common practice is for designers to place dowel bars at a certain, consistent spacing such that a sufficient number of dowels are available to effectively transfer anticipated loads. In many cases, however, the standards developed today for new highway construction simply do not reflect the design needs of low traffic volume, rural roads. The objective of this research was to evaluate the impact of the number of dowel bars and dowel location on joint performance and ultimately on pavement performance. For this research, test sections were designed, constructed, and tested in actual field service pavement. Test sections were developed to include areas with load transfer assemblies having three and four dowels in the outer wheel path only, areas with no joint reinforcement whatsoever, and full lane dowel basket assemblies as the control. Two adjacent paving projects provided both rural and urban settings and differing base materials. This report documents the approach to implementing the study and provides discussion and suggestions based on the results of the research. The research results indicate that the use of single three or four dowel basket assemblies in the outer wheel path is acceptable for use in low truck volume roads. In the case of roadways with relatively stiff bases such as asphalt treated or stabilized bases, the use of the three dowel bar pattern in the outside wheel path is expected to provide adequate performance over the design life of the pavement. In the case of untreated or granular bases, the results indicate that the use of the three or four dowel bar basket in both wheel paths provides the best long-term solution to load transfer and faulting measurements.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: NovoTTF is a portable device delivering low-intensity, intermediate-frequency, electric fields using noninvasive, disposable scalp electrodes. These fields physically interfere with cell division. Preliminary studies in recurrent and newly diagnosed glioblastoma (GBM) have shown promising results. A phase III study in recurrent GBM has recently been concluded. METHODS: Adults (KPS ≥ 70%) with recurrent GBM (any recurrence) were randomized (stratified by surgery and center) to either NovoTTF administered continuously (20-24 hours/day, 7 days/week) or the best available chemotherapy (best physician choice [BPC]). Primary endpoint was overall survival (OS); 6-month progression-free survival (PFS6), 1-year survival, and QOL were secondary endpoints. RESULTS: Two hundred thirty-seven patients were randomized (28 centers in the United States and Europe) to either NovoTTF alone (120 patients) or BPC (117 patients). Patient characteristics were balanced, median age was 54 years (range, 23-80 years), median KPS was 80% (range, 50-100). One quarter had surgery for recurrence, and over half were at their second or more recurrence. A survival advantage for the device group was seen in patients treated according to protocol (median OS, 7.8 months vs. 6.1 months; n = 185; p = 0.01). Moreover, subgroup analysis in patients with better prognostic baseline characteristics (KPS ≥ 80%; age ≤ 60; 1st-3rd recurrence) demonstrated a robust survival benefit for NovoTTF patients compared to matched BPC patients (median OS, 8.8 months vs. 6.6 months; n = 110; p < 0.01). In this group, 1-year survival was 35% vs. 20% and PFS6 was 25.6% vs. 7.7%. Interestingly, in patients who failed bevacizumab prior to the trial, OS was also significantly extended by NovoTTF (4.4 months vs. 3.1 months; n = 23 vs. n = 21; p < 0.02). Quality of life was equivalent or superior in NovoTTF patients. CONCLUSIONS: NovoTTF, a noninvasive, novel cancer treatment modality shows significant therapeutic efficacy with improved quality of life. The impact of NovoTTF was more pronounced when patients with better baseline prognostic factors were treated. A large scale phase III clinical trial in newly diagnosed GBM is currently being conducted.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Parastomal hernia (PSH) is the most frequent long-term stoma complication with serious negative effects on quality of life. Surgical revision is often required and has a substantial morbidity and recurrence rate. The development of PSH requires revisional surgery with a substantial perioperative morbidity and high failure rate in the long-term follow-up. Prophylactic parastomal mesh insertion during stoma creation has the potential to reduce the rate of PSH, but carries the risk of early and late mesh-related complications such as infection, fibrosis, mesh shrinkage, and/or bowel erosion. We developed a new stomaplasty ring (KORING), which is easy to implant, avoids potential mesh-related complications, and has a high potential of long-term prevention of PSH. Here we describe the technique and the first use.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The progressive behavior of the blood pressure of term newborns during the first week of life was assessed by the simultaneous use of oscillometric and Doppler methods. A total of 174 term neonates born at the Municipal Hospital Odilon Behrens in Belo Horizonte, from March 1996 to February 1997, were prospectively assessed. The oscillometric and Doppler ultrasonic methods were simultaneously used for four consecutive recordings obtained at 12 ± 6, 24 ± 6 and 72 ± 24 h and on the 7th ± 1 day of life. The combined use of the two methods simplified the procedure, with automatic cuff inflation and deflation, and speed was properly controlled with an automatic pressure monitor. The procedure was performed using a Y-connection to the mercury sphygmomanometer, with blood pressure being recorded with an automatic device and systolic blood pressure being measured simultaneously by Doppler ultrasound. The newborns were awake, not crying and in the supine position. A statistically significant increase in systolic and diastolic blood pressure was observed between the first and second, and the third and fourth measurements by Doppler and oscillometric methods. No significant correlation between birth weight, length, ponderal index and blood pressure was observed. The technique used represents a simpler and more accurate procedure for blood pressure measurement.