991 resultados para Denture, Partial, Fixed
Resumo:
Objectives: The present study used strain gauge analysis to perform an in vitro evaluation of the effect of axial loading on 3 elements of implant-supported partial fixed prostheses, varying the type of prosthetic cylinder and the loading points. Material and methods: Three internal hexagon implants were linearly embedded in a polyurethane block. Microunit abutments were connected to the implants applying a torque of 20 Ncm, and prefabricated Co-Cr cylinders and plastic prosthetic cylinders were screwed onto the abutments, which received standard patterns cast in Co-Cr alloy (n = 5). Four strain gauges (SG) were bonded onto the surface of the block tangentially to the implants, SG 01 mesially to implant 1, SG 02 and SG 03 mesially and distally to implant 2, respectively, and SG 04 distally to implant 3. Each metallic structure was screwed onto the abutments with a 10 Ncm torque and an axial load of 30 kg was applied at five predetermined points (A, B, C, D, E). The data obtained from the strain gauge analyses were analyzed statistically by RM ANOVA and Tukey's test, with a level of significance of p<0.05. Results: There was a significant difference for the loading point (p=0.0001), with point B generating the smallest microdeformation (239.49 με) and point D the highest (442.77 με). No significant difference was found for the cylinder type (p=0.748). Conclusions: It was concluded that the type of cylinder did not affect in the magnitude of microdeformation, but the axial loading location influenced this magnitude.
Resumo:
Objectives: The present study used strain gauge analysis to perform an in vitro evaluation of the effect of axial loading on 3 elements of implant-supported partial fixed prostheses, varying the type of prosthetic cylinder and the loading points. Material and methods: Three internal hexagon implants were linearly embedded in a polyurethane block. Microunit abutments were connected to the implants applying a torque of 20 Ncm, and prefabricated Co-Cr cylinders and plastic prosthetic cylinders were screwed onto the abutments, which received standard patterns cast in Co-Cr alloy (n=5). Four strain gauges (SG) were bonded onto the surface of the block tangentially to the implants, SG 01 mesially to implant 1, SG 02 and SG 03 mesially and distally to implant 2, respectively, and SG 04 distally to implant 3. Each metallic structure was screwed onto the abutments with a 10 Ncm torque and an axial load of 30 kg was applied at five predetermined points (A, B, C, D, E). The data obtained from the strain gauge analyses were analyzed statistically by RM ANOVA and Tukey's test, with a level of significance of p<0.05. Results: There was a significant difference for the loading point (p=0.0001), with point B generating the smallest microdeformation (239.49 mu epsilon) and point D the highest (442.77 mu epsilon). No significant difference was found for the cylinder type (p=0.748). Conclusions: It was concluded that the type of cylinder did not affect in the magnitude of microdeformation, but the axial loading location influenced this magnitude.
Resumo:
The aim of this in vitro study was to use strain gauge (SG) analysis to compare the effects of the implant-abutment joint, the coping, and the location of load on strain distribution in the bone around implants supporting 3-unit fixed partial prostheses. Three external hexagon (EH) implants and 3 internal hexagon (IH) implants were inserted into 2 polyurethane blocks. Microunit abutments were screwed onto their respective implant groups. Machined cobalt-chromium copings and plastic copings were screwed onto the abutments, which received standard wax patterns. The wax patterns were cast in a cobalt-chromium alloy (n = 5): group 1 = EH/machined. group 2 = EH/plastic, group 3 = IH/machined, and group 4 = IH/plastic. Four SGs were bonded onto the surface of the block tangentially to the implants. Each metallic structure was screwed onto the abutments and an axial load of 30 kg was applied at 5 predetermined points. The magnitude of microstrain on each SG was recorded in units of microstrain (mu epsilon). The data were analyzed using 3-factor repeated measures analysis of variance and a Tukey test (alpha = 0.05). The results showed statistically significant differences for the type of implant-abutment joint, loading point, and interaction at the implant-abutment joint/loading point. The IH connection showed higher microstrain values than the EH connection. It was concluded that the type of coping did not interfere in the magnitude of microstrain, but the implant/abutment joint and axial loading location influenced this magnitude.
Minimal intervention dentistry and older patients part 2: minimally invasive operative interventions
Resumo:
As described in the first paper of this two part series, the expansion of our older population and the concomitant reduction in levels of edentulism will result in an increase in the number of patients presenting in general practice with complex restorative challenges. The application of the concepts of minimal intervention dentistry and minimally invasive operative techniques may offer a powerful armamentarium to the general dentist to provide ethical and conservative treatment to older patients.
Clinical Relevance: When it is unavoidable, operative intervention should be as minimally invasive as practicable in older patients to preserve the longevity of their natural dentition.
Resumo:
Scleroderma is a connective tissue disorder that can present with orofacial involvement. A 48 year-old patient presented to Cork University Dental Hospital with concerns about the appearance of her upper central incisor teeth, which had become progressively mobile in recent years. A diagnosis of localised scleroderma had been made a number of years previously by her medical practitioner and the patient reported that her scleroderma-associated microstomia had progressed significantly in recent years. Most reports of this condition advocate the use of sectional impression trays and sectional dentures to replace missing teeth. This report describes the use of resin-bonded bridgework (RBB) and discusses the possible advantages of this treatment option over those already presented in the literature.
Resumo:
Resin bonded bridgework (RBB) is a technique often overlooked by practitioners despite a large amount of evidence supporting the technique. In Cork University Dental School an evidence-based, standardised approach for the delivery of RBB by undergraduate students has been developed over the past 10 years. The aim of this study was to evaluate the success of this standardised approach on the delivery of RBB by students. 222 bridges were reviewed which had been delivered over a 6 year time period between 2002 and 2007. A success rate of 84.1% was achieved with a mean survival time of 41 months. This study illustrates that predictable and highly successful RBB can be delivered by inexperienced clinicians using an evidence-based, standardised approach.
Resumo:
OBJECTIVE: To investigate the impact of tooth replacement on the nutritional status of partially dentate older patients, and, to compare two different tooth replacement strategies; conventional treatment using removable partial dentures and functionally orientated treatment based on the shortened dental arch.
BACKGROUND: Amongst older patients, diet plays a key role in disease prevention, as poor diets have been linked to numerous illnesses. Poor oral health and loss of teeth can have very significant negative effects on dietary intake and nutritional status for elderly patients. There is evidence that good oral health generally, has positive effects on the nutritional intake of older adults.
MATERIALS AND METHODS: A randomised, controlled clinical trial was designed to investigate the impact of tooth replacement on the nutritional status of partially dentate elders. Forty-four patients aged over 65 years completed the trial, with 21 allocated to conventional treatment and 23 allocated to functionally orientated treatment. Nutritional status was accessed at baseline and after treatment using the Mini Nutritional Assessment (MNA) and a range of haematological markers.
RESULTS: At baseline, relationships were observed between the number of occluding tooth contacts and some measures of nutritional status. As the number of contacts increased, MNA scores (R = 0.16), in addition to vitamin B12 (R = 0.21), serum folate (R = 0.32) and total lymphocyte count (R = 0.35), also increased. After treatment intervention, the only measure of nutritional status that showed a statistically significant improvement for both treatment groups was MNA score (p = 0.03). No significant between group differences were observed from analysis of the haematological data.
CONCLUSION: In this study, prosthodontic rehabilitation with both conventional treatment and functionally orientated treatment resulted in an improvement in MNA score. Haematological markers did not illustrate a clear picture of improvement in nutritional status for either treatment group.
Resumo:
Toothwear is commonly observed in dentate older patients and may be physiological or pathological in nature. Toothwear can be caused by abrasion, attrition, erosion or a combination of aetiologies. Where treatment is required, a number of options exist, including the use of adhesive materials and fixed and removable prosthodontics.
CLINICAL RELEVANCE: With patients retaining natural teeth into old age, physiological and pathological toothwear amongst dentate older patients is an increasingly common presentation.
Resumo:
The authors analysed the simultaneous effects of the dimensional and weight alteration of resins utilized for esthetic facets submitted to warehousing conditions and periods of time. The resins showed different behaviour and a neat correlation between dimensional alteration and weight. The condition of immersion promoted dimensional alteration 50% lower and an alteration of weight three times higher.
Resumo:
The purpose of this study was to compare the enamel/resin/metal bond tensile strength by using human canines, in which castings were bonded. These castings were obtained by Co-Cr or Ni-Cr alloys and showed four types of mechanisms of retention: 50 micrograms aluminum oxide abrasive, electrochemical etch, acrylic beads metal mesh. The castings were bonded utilizing Comspan Opaque and Panavia Ex. The specimens were subjected to tensile forces after 24 hours in an Instron machine. The castings subjected to 50 micrograms aluminum oxide abrasive and bonded utilizing Panavia EX showed the biggest bond tensile strength.
Resumo:
Objectives: The aim of this study was to evaluate the effect of thermal and mechanical cycling alone or in combination, on the flexural strength of ceramic and metallic frameworks cast in gold alloy or titanium. Methods: Metallic frameworks (25 mm × 3 mm × 0.5 mm) (N = 96) cast in gold alloy or commercial pure titanium (Ti cp) were obtained using acrylic templates. They were airborne particle-abraded with 150 μm aluminum oxide at the central area of the frameworks (8 mm × 3 mm). Bonding agent and opaque were applied on the particle-abraded surfaces and the corresponding ceramic for each metal was fired onto them. The thickness of the ceramic layer was standardized by positioning the frameworks in a metallic template (height: 1 mm). The specimens from each ceramic-metal combination (N = 96, n = 12 per group) were randomly assigned into four experimental fatigue conditions, namely water storage at 37 °C for 24 h (control group), thermal cycling (3000 cycles, between 4 and 55 °C, dwell time: 10 s), mechanical cycling (20,000 cycles under 10 N load, immersion in distilled water at 37 °C) and, thermal and mechanical cycling. A flexural strength test was performed in a universal testing machine (crosshead speed: 1.5 mm/min). Data were statistically analyzed using two-way ANOVA and Tukey's test (α = 0.05). Results: The mean flexural strength values for the ceramic-gold alloy combination (55 ± 7.2 MPa) were significantly higher than those of the ceramic-Ti cp combination (32 ± 6.7 MPa) regardless of the fatigue conditions performed (p < 0.05). Mechanical and thermo-mechanical fatigue decreased the flexural strength results significantly for both ceramic-gold alloy (52 ± 6.6 and 53 ± 5.6 MPa, respectively) and ceramic-Ti cp combinations (29 ± 6.8 and 29 ± 6.8 MPa, respectively) compared to the control group (58 ± 7.8 and 39 ± 5.1 MPa, for gold and Ti cp, respectively) (p < 0.05) (Tukey's test). While ceramic-Ti cp combinations failed adhesively at the metal-opaque interface, gold alloy frameworks exhibited a residue of ceramic material on the surface in all experimental groups. Significance: Mechanical and thermo-mechanical fatigue conditions decreased the flexural strength values for both ceramic-gold alloy and ceramic-Ti cp combinations with the results being significantly lower for the latter in all experimental conditions. © 2007 Academy of Dental Materials.
Resumo:
Among the factors that influence the success of treatment of a root perforation, its location and possibility of contamination are determinant because the interaction of these 2 factors may result in significant periodontal injury. The management of cases of hard-to-reach contaminated perforations depends on the choice of an adequate technique. In the case reported in this article, controlled orthodontic tooth extrusion was successfully performed to treat gingival recession secondary to root perforation. The outcomes showed that this technique preserves the zone of attached gingiva, maintains the crown height, and prevents the involvement of the supporting bone tissue. The favorable clinical and radio?graphic conditions after 7 years of follow-up demonstrate the viability of this treatment approach.
Resumo:
Esthetic orthodontic appliances continue to appeal to more patients, which results in objections to extraction spaces that remain for several months during orthodontic therapy. This has led orthodontists to design temporary pontics that fill extraction sites and that can be reduced as the spaces close. This report describes a simple, efficient, and expeditious technique for making such pontics. © 2010 Quintessence Publishing Co, Inc.