885 resultados para Dental precision attachment
Resumo:
Objective: to the purpose of this study was to compare the stress distribution in the peri-implant hard tissue on different attachment systems for mandibular or maxillary implant-retained overdentures. Material and methods: the search for published studies was performed on PubMed/Medline database covering the period of January 2000 to April 2014. The selection of the eligible studies was performed according to including and excluding criteria. Results: a total of 140 studies were screened and according to the search strategy, 21 studies were selected for this review. Eight studies perfomed strain-gauge analysis, 5 evaluated the stress distribution though photoelastic test and 7 performed tridimensional finite element analysis. Only one study in vivo was included. Non-splinted O-rings showed better stress distribution than other bar-clip attachment systems. Conclusions: the present study did not find sufficient evidences regarding the most indicated attachment system for overdentures with better stress distribution for the peri-implant hard tissue. The methodologies analyzed should be complemented with other tests and used as a tool for further clinical studies.
Resumo:
For older patients, clinicians should consider maintaining teeth and using functionally-orientated treatment strategies as an alternative to removable prostheses. When the remaining dentition has a poor prognosis, key teeth should be preserved as overdenture abutments and a gradual transition to edentulousness planned. Where complete dentures are provided, these can be retained using dental implants to overcome many of the problems associated with conventional replacement dentures.
CLINICAL RELEVANCE: The elderly population of today is better informed and more demanding of oral healthcare providers than previous generations. Clinicians should be aware of all the prosthodontic treatment options available for older patients.
Resumo:
Aim: There is little information considering the framework association between cast clasps and attachments. The aim of this study was to evaluate the retention strength of frameworks match circumferential clasps and extra resilient attachment cast in three different alloys (cobalt-chromium, nickel-chromium titanium and commercially pure titanium), using two undercut (0.25 and 0.75 mm) and considering different period of time (0, 1/2, 1, 2, 3, 4 and 5 years). Methods: Using two metallic matrices, representing a partially edentulous mandibular right hemiarch with the first molar crown, canine root and without premolars, 60 frameworks were fabricated. Three groups (n = 20) of each metal were cast and each group was divided into two subgroups (n = 10), corresponding the molar undercut of 0.25 mm and 0.75 mm. The nylon male was positioned at the matrix and attached to the acrylic resin of the prosthetic base. The samples were subjected to an insertion and removal test under artificial saliva environment. Results: The data were analyzed and compared with ANOVAs and Tukey's test at 95% of probability. The groups cast in cobaltchromium and nickel-chromium-titanium had the highest mean retention strength (5.58 N and 6.36 N respectively) without significant difference between them, but statistically different from the group cast in commercially pure titanium, which had the lowest mean retention strength in all the periods (3.46 N). The association frameworks using nickel-chromium-titanium and cobalt-chromium could be used with 0.25 mm and 0.75 mm of undercut, but the titanium samples seems to decrease the retention strength, mainly in the 0.75 mm undercut. The circumferential clasps cast in commercially pure titanium used in 0.75 mm undercuts have a potential risk of fractures, especially after the 2nd year of use. Conclusion: This in vitro study showed that the framework association between cast clasp and an extra resilient attachment are suitable to the three metals evaluated, but strongly suggest extra care with commercially pure titanium in undercut of 0.75 mm. Clinical significance: Frameworks fabricated in Cp Ti tend to decrease in retentive strength over time and have a potential risk of fracture in less than 0.75 mm of undercut.
Resumo:
Objectives: The aim of this study was to evaluate the stress distribution in mandibular free-end removable partial dentures (RPD) associated with FPD in the abutment teeth considering different inclinations of the residual ridge: (1) horizontal and (2) distal descending ridges and two designs of free-end RPD with different attachment systems were tested: (1) clasp and (2) system ERA. Methods. Axial loads (100 N) were applied on the teeth of the RPD. The images were recorded and the stress distribution was evaluated through photoelastic fringes. Results. In general, the distal descending ridge presented more photoelastic fringes in the region of the roots of the abutment teeth while the horizontal ridge exhibited higher compression in the base of the prosthesis. In the horizontal ridge, the denture with clasp presented more favourable stress distribution than the denture with the system ERA. In the distal descending ridge, the denture with the system ERA relieved the region of the abutment teeth and overloaded the residual ridge. Conclusion: The horizontal ridge presented more favourable performance; the dentures with clasp exhibited better performance for both ridges evaluated; the denture with the system ERA presented better results in the distal descending ridge. © 2013 Informa Healthcare.
Resumo:
The dissatisfaction of the treatment with mandibular complete dentures in edentulous patients has been a constant problem in Dentistry. Often, the absence of stability and retention, resultants of a physiologic condition and alveolar ridge resorption, bring reduction of chewing force, speech problems and social life interference. In these cases, the rehabilitation over osseointegrated implants can be an effective and safe alternative of treatment. When it is not possible to put implants in appropriate number and disposition, it is necessary to make a simple and low costing prosthetic planning, which makes resurge the overdentures. Various implant supported attachment systems for overdentures have been developed in the dental market. Thus, intending to facilitate the professional choice, this study review the literature about attachment systems O’ring and bar- clip in its following aspect: retention level, stress distribution, hygiene complications and patient satisfaction.
Resumo:
This study aimed to compare the influence of single-standing or connected implants on stress distribution in bone of mandibular overdentures by means of two-dimensional finite element analysis. Two finite element models were designed using software (ANSYS) for 2 situations: bar-clip (BC) group-model of an edentulous mandible supporting an overdenture over 2 connected implants with BC system, and o'ring (OR) group-model of an edentulous mandible supporting an overdenture over 2 single-standing implants with OR abutments. Axial loads (100 N) were applied on either central (L1) or lateral (L2) regions of the models. Stress distribution was concentrated mostly in the cortical bone surrounding the implants. When comparing the groups, BC (L1, 52.0 MPa and L2, 74.2 MPa) showed lower first principal stress values on supporting tissue than OR (L1, 78.4 MPa and L2, 76.7 MPa). Connected implants with BC attachment were more favorable on stress distribution over peri-implant-supporting tissue for both loading conditions.
Resumo:
Pós-graduação em Odontologia - FOA
Resumo:
OBJECTIVE To compare the precision of fit of full-arch implant-supported screw-retained computer-aided designed and computer-aided manufactured (CAD/CAM) titanium-fixed dental prostheses (FDP) before and after veneering. The null-hypothesis was that there is no difference in vertical microgap values between pure titanium frameworks and FDPs after porcelain firing. MATERIALS AND METHODS Five CAD/CAM titanium grade IV frameworks for a screw-retained 10-unit implant-supported reconstruction on six implants (FDI tooth positions 15, 13, 11, 21, 23, 25) were fabricated after digitizing the implant platforms and the cuspid-supporting framework resin pattern with a laser scanner (CARES(®) Scan CS2; Institut Straumann AG, Basel, Switzerland). A bonder, an opaquer, three layers of porcelain, and one layer of glaze were applied (Vita Titankeramik) and fired according to the manufacturer's preheating and fire cycle instructions at 400-800°C. The one-screw test (implant 25 screw-retained) was applied before and after veneering of the FDPs to assess the vertical microgap between implant and framework platform with a scanning electron microscope. The mean microgap was calculated from interproximal and buccal values. Statistical comparison was performed with non-parametric tests. RESULTS All vertical microgaps were clinically acceptable with values <90 μm. No statistically significant pairwise difference (P = 0.98) was observed between the relative effects of vertical microgap of unveneered (median 19 μm; 95% CI 13-35 μm) and veneered FDPs (20 μm; 13-31 μm), providing support for the null-hypothesis. Analysis within the groups showed significantly different values between the five implants of the FDPs before (P = 0.044) and after veneering (P = 0.020), while a monotonous trend of increasing values from implant 23 (closest position to screw-retained implant 25) to 15 (most distant implant) could not be observed (P = 0.169, P = 0.270). CONCLUSIONS Full-arch CAD/CAM titanium screw-retained frameworks have a high accuracy. Porcelain firing procedure had no impact on the precision of fit of the final FDPs. All implant microgap measurements of each FDP showed clinically acceptable vertical misfit values before and after veneering. Thus, the results do not only show accurate performance of the milling and firing but show also a reproducible scanning and designing process.
Resumo:
This case report details the successful rehabilitation of an edentulous patient using a complete upper prosthesis and a lower implant retained overdenture. The provision of care was split between a specialist centre and a primary care setting. This approach reduced inconvenience to the patient. Modern surgical and prosthodontic techniques also reduced the total delivery time. After initial consultation a new set of complete dentures was prescribed with changes in design to the originals. The patient was also planned for placement of two mandibular implants to stabilise and retain the mandibular denture. The first line of treatment involved provision of a new set of dentures constructed by the patient's general dental practitioner. Dental implants were then placed in a specialist centre and the patient returned to the dental practice for attachment of the lower denture to the dental implants. The benefits and success of mandibular implant retained dentures are well documented. With delivery of the overdenture, the patient reported increased satisfaction with his prostheses which allowed him to eat a greater range of foods and enabled him to feel confident when speaking and socialising.
Resumo:
O estudo das estruturas da placas maxilo-dentárias dos rincossauros Hyperodapedon Huxley, 1859, do Triássico da Formação Santa Maria, em nova abordagem histológica e ontogênica resultou na identificação da natureza do esmalte aprismático verdadeiro, de variados elementos histológicos dentinários e osteológicos, e de um centro de ossificação periosteal primário. Também foram encontradas evidências histológicas dos mecanismos de fusionamento maxilo-dentinário e amelo-maxilar. Com estes elementos, inferimos os modelos de organogênese dental, da ontogênese maxilar e dos mecanismos de fusionamento maxilodental. Encontrou-se uma singular e raríssima coroa dental, imatura e ainda não erupcionada, na região posterior da placa dental e assim evidenciou-se a correta posição da margem odontogenicamente ativa. Adicionalmente inferiu-se a localização da posição da lâmina dentária embrionária. Constatou-se a não formação de alvéolos dentários, de cemento radicular e do espaço necessário à formação do ligamento periodontal e, assim, se deduziu a não formação do folículo dental embriônico. As presenças de especiais elementos anatômicos e histológicos nos tecidos ósseos periapicais evidenciam o crescimento radicular contínuo, enquanto a forma e o fusionamento radicular imediato depõe a favor de uma função dentária fisiológica diferenciada para as baterias dentárias maxilares dos Rincossauros do gênero Hyperodapedon. Os mecanismos que possibilitaram o controle embriônico para a deposição das lamelas de tecido ósseo coronal e seu preciso fusionamento sobre o esmalte dentário, declinam por modificações nas funções tardias do órgão reduzido do esmalte e pela presença de uma membrana oral com funções osteogênicas e também protetivas, situada nas porções posteriores da placa maxilo-dentária em desenvolvimento. Mudanças heterocrônicas no tempo de diferenciação das células da crista neural embriônica e em seus derivados, como a lâmina dentária e órgãos dentários embrionários ou correlacionadas com a organogênese das placas maxilo-dentárias e seus anexos periodontais, todos como condições plesiomórficas para Diápsidas Triássicos, poderiam ser as causas responsáveis pela origem e evolução deste estranho aparelho estomatognático nos clados de Hyperodapedon sp..
Resumo:
This report presents the use of a dental implant with an anti-rotational attachment for the retention of a thumb prosthesis. A retention system was manufactured with an attachment (UCLA) screwed into the implant with a two-bar system that was cast in metallic silver palladium. A substructure made from heat-cured acrylic resin was joined to the retention system by clips to join the thumb to the finger (bar clip) in the cast with implant rejoinder. The silicone material, Silastic-MDX 44210, was used to achieve function and aesthetics. Following osseointegration, no skin problems were observed. Whilst the implant-retained digital prosthesis presented some motor limitations, it allowed the patient to return to entertainment and achieve social conviviality.
Resumo:
This finite element analysis compared stress distribution on complete dentures and implant-retained overdentures with different attachment systems. Four models of edentulous mandible were constructed: group A (control), complete denture; group B, overdenture retained by 2 splinted implants with bar-clip system; group C, overdenture retained by 2 unsplinted implants with o'ring system; and group D, overdenture retained by 2 splinted implants with bar-clip and 2 distally placed o'ring system. Evaluation was performed on Ansys software, with 100-N vertical load applied on central incisive teeth. The lowest maximum general stress value (in megapascal) was observed in group A (64.305) followed by groups C (119.006), D (258.650), and B (349.873). The same trend occurred it) supporting tissues with the highest stress value for cortical bone. Unsplinted implants associated with the o'ring attachment system showed the lowest maximum stress values among all overdenture groups. Furthermore, o'ring system also improved stress distribution when associated with bar-clip system.
Resumo:
Complete and partial loss of maxillary bone may jeopardize oral physiology and generate complications as oral-sinus-nasal communication. Palatal obturator prostheses are a treatment alternative for rehabilitation of these patients. The aim of this study was to assess stress distribution, through photoelasticity, on palatal obturator prostheses associated with different attachment systems (o'ring, bar clip, and o'ring/bar clip) of implants and submitted to relining. Two photoelastic models were fabricated according to an experimental maxillary model with oral-sinus-nasal communication. One model did not present implants, whereas the other included 2 implants with 13.0 mm in length in the left ridge. Four colorless maxillary obturator prostheses were fabricated and relined with soft silicone. One of these prostheses presented no attachment system, whereas the remaining prostheses included attachment systems adapted to the implants. The assembly (model/attachment system/prosthesis) was positioned in a circular polariscope during loading with 100 N at 10 mm/s. The results were based on observation during the experiment and photographic records of stress on the photoelastic model. The bar clip system exhibited the highest stress concentration followed by o'ring/bar clip and o'ring systems. The attachment systems presented different stress distribution with greater concentration surrounding the implants and homogenous stress distribution on the photoelastic model without implants. The highest concentration of fringes occurred, in ascending order, with o'ring, o'ring/bar clip, and bar clip systems.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)