954 resultados para Dental instruments and apparatus
Resumo:
Mode of access: Internet.
Resumo:
"Issued April 1980."
Resumo:
"October 1979."
Resumo:
Objective: To determine the variation in prevalence of temporomandibular disorders (TMD), other side effects, and technical complications during 5 years of sleep apnea treatment with a mandibular advancement device. Materials and Methods: Forty patients diagnosed with obstructive sleep apnea received an adjustable appliance at 70% of the maximum protrusion. The protrusion was then progressively increased. TMD (diagnosed according to the Research Diagnostic Criteria for TMD), overjet, overbite, occlusal contacts, subjective side effects, and technical complications were recorded before and a mean of 14, 21, and 58 months after treatment and analyzed by the Wilcoxon test (P Less-than .05). Results: Fifteen patients still used the oral appliance at the 5-year follow-up, and no significant variation in TMD prevalence was observed. Subjective side effects were common, and a significant reduction was found in overjet, overbite, and in the number of occlusal contacts. Furthermore, the patients made a mean of 2.5 unscheduled dental visits per year and a mean of 0.8 appliance repairs/relines per year by a dental technician. The most frequent unscheduled visits were needed during the first year and were a result of acrylic breakage on the lateral telescopic attachment, poor retention, and other adjustments to improve comfort. Conclusions: Five-year oral appliance treatment does not affect TMD prevalence but is associated with permanent occlusal changes in most sleep apnea patients during the first 2 years. Patients seek several unscheduled visits, mainly because of technical complications.
Resumo:
Water lines are an important source of potentíal contamination. Every dental unit is equipped with small-bore flexible plastic tubing to bring water to different hand pieces, such as the air/water syringe, the ultrasonic scaler or the high-speed hand piece. Most dental units are connected directly to municipal distribution systems for potable water and chlorinated or not, this water contains diverse...
Resumo:
Section "A": Dissecting and Post-Mortem Instruments Diagnostic Instruments and Apparatus Microscopes and Microscopic Accessories Laboratory Apparatus and Glass Ware Apparatus for Blood and Urine Analysis Apparatus for Phlebotomy, Cupping and Leeching Apparatus for Infusion and Transfusion Syringes for Aspiration and Injection Osteological Preparations Section "B": Anaesthetic, General Operating, Osteotomy, Trepanning, Bullet, Pocket Case, Cautery, Ligatures, Sutures, Dressings, Etc. Section "B" continued Section "C": Eye, Ear, Nasal, Dermal, Oral, Tonsil, Tracheal, Laryngeal,Esophageal, Stomach, Intestinal, Gall Bladder Section "C": continued Section "D": Rectal, Phimosis, Prostatic, Vesical, Urethral, Ureteral, Instruments Section "E": Gynecic, Hysterectomy, Obstetrical, Instrument Satchels, Medicine Cases Section "F": Electric Cautery Transformers, Electro-Cautery Burners and Accessories, Electric Current Controllers, Electro-Diagnostic Outfits, Electrolysis Instruments Electro-Therapeutic Lamps, Faradic Batteries, Galvanic Batteries Section "G": Office Furniture, Office Sterilizing Apparatus, Hospital Supplies, Surgical Rubber Goods, Sick Room Utensils, Invalid Rolling Chairs, Invalid Supplies Section "H": Artificial Limbs, Deformity Apparatus, Fracture Apparatus, Splints, Splint Material, Elastic Hosiery, Abdominal Supporters, Crutches, Trusses, Suspensories, Etc. Index
Resumo:
"Project no. NM 008 015.08"
Resumo:
El auge de las técnicas mecánicas, mediante rotación continua, en la preparación del sistema de conductos radiculares obliga a realizar una serie de reflexiones respecto a las ventajas e inconvenientes de las mismas según los diferentes objetivos que se persiguen en esta fase de la terapéutica. Se describe el sistema de instrumentación HERO 642 comparado con otras marcas y se expone la técnica propugnada por los diseñadores, Vulcain JM y Calas P, junto con las modificaciones propuestas por los autores del artículo. Finalmente, se establecen unas premisas fundamentales para el correcto empleo de la instrumentación rotatoria como técnica habitual en el tratamiento de conductos radiculares, en comparación con otros sistemas.
Resumo:
Water delivered by dental units during routine dental practice is densely contaminated by bacteria. The aim of this study was to determine actual isolation of the microorganisms sprayed from Dental Unit Water Lines (DUWLs) when enrichment cultures are performed and to compare frequencies with those obtained without enrichment cultures. Moreover, the antimicrobial susceptibilities of the microorganisms isolated were also studied. Water samples were collected from one hundred dental equipments in use at Dental Hospital of our University in order to evaluate the presence/absence of microorganisms and to perform their presumptive identification. Aliquots from all of the samples were inoculated in eight different media including both enrichment and selective media. Minimal inhibitory concentrations (MIC) were determined by the broth dilution method. The results herein reported demonstrate that most of the DUWLs were colonized by bacteria from human oral cavity; when enrichment procedures were applied the percentage of DUWLs with detectable human bacteria was one hundred percent. The results showed that in order to evaluate the actual risk of infections spread by DUWLs the inclusion of a step of pre-enrichment should be performed. The need for devices preventing bacterial contamination of DUWLs is a goal to be achieved in the near future that would contribute to maintain safety in dental medical assistance
Resumo:
Mode of access: Internet.
Resumo:
This study evaluated the efficacy of 2 types of rotary instruments employed in association with sodium hypochlorite (NaOCl) or EDTA in removing calcium hydroxide (CH) residues from root canals dentin walls. Forty-two mandibular human incisors were instrumented with the ProTaper System up to F2 instrument, irrigated with 2.5% NaOCl followed by 17% EDTA and filled with a CH intracanal dressing. After 7 days, the CH dressing was removed using 4 techniques: NiTi rotary instrument size 25, 0.06 taper (K3 Endo) and irrigation with 17% EDTA (Group 1), NiTi rotary F1 instrument (ProTaper) and irrigation with 17% EDTA (Group 2), NiTi rotary instrument size 25, 0.06 taper and irrigation with 2.5% NaOCl (Group 3) and NiTi rotary F1 instrument and irrigation with 2.5% NaOCl (Group 4). Two roots without intracanal dressing were used as negative controls. Teeth were evaluated by scanning electron microscopy, in the cervical and apical canal thirds. None of the techniques removed the CH dressing completely. In the apical and cervical thirds, F1 instrument was better than instrument size 25, 0.06 taper in removing CH residues (p<0.05), regardless of the final irrigating solution. No difference was found between the irrigating solutions in the groups of F1 instrument and of instrument size 25, 0.06 taper (p>0.05). The negative controls had no CH residues on the dentin walls. In conclusion, the ProTaper F1 instrument was better than K3 Endo instrument size 25, 0.06 taper in the removal of CH intracanal medication, regardless of irrigating solution used.
Resumo:
Influence of cutting instruments and The aim of this study was to analyze the hybrid layer in noncarious dentin prepared by different cutting instruments and restored with composite resin. The cavities were randomly prepared in 40 specimens using a high-speed diamond bur (KG Sorensen 1013) and an ultrasonic tip (CVDentus C22). The cavities were restored with composite resin by varying the adhesive system between the Adper™ Single Bond (2 x 1 system, primer+adhesive) and the Prompt L-Pop™ (3 x 1 system, self-etching). The restorations were hemisected longitudinally and analyzed in the SEM (Scanning electron microscopy) in order to evaluate the hybrid layer and resinous tags characteristics, using scores ranging from 1 to 6. The Pearson test revealed a high correlation coefficient and good significance levels for both intra- and inter-raters values (r=0.90). The data were statistically analyzed using the Mann-Whitney test (P≤0.05). A larger proportion of regular hybrid layers with numerous tags were observed in the dentin prepared using the high-speed diamond burs and restored with a 2 × 1 adhesive system. Alternatively, the 3 × 1 adhesive system promoted the generation of a thin hybrid layer with few tags. After preparation using an ultrasonic tip revealed few or no tags after the preparation and 2 × 1 or 3 × 1 adhesive system application. The high-speed diamond burs produced a dentin surface that was more favorable to restorative material adhesion than the ultrasonic tips, regardless of the adhesive system used.
Resumo:
Objectives: Ozone has been used as an alternative method for the decontamination of water, food, equipment and instruments. The objective of this study was to evaluate the antimicrobial effects of ozonated water on the sanitization of dental instruments that were contaminated by Escherichia coli, Staphylococcus aureus, Candida albicans and the spores of Bacillus atrophaeus. Methods: A total of one hundred and twenty standardized samples of diamond dental burs were experimentally contaminated with E. coli (ATCC 25922), S. aureus (ATCC 6538) and C. albicans (ATCC 18804) and the spores of B. atrophaeus (ATCC 6633) for 30min. After the contamination, the samples were exposed to ozonated water (10mg/L O3) for 10 or 30min. The control group was composed of samples that were exposed to distilled water for 30min. After the exposure to the ozonated water, 0.1mL aliquots were seeded onto BHI agar to count the colony-forming units per milliliter (CFU/mL) of E. coli, S. aureus, and B. atrophaeus. Sabouraud dextrose agar was used to count the CFU/mL of C. albicans. The results were subjected to an analysis of variance and the Tukey test. Results: For all of the microorganisms studied, the ozonated water reduced the number of CFU/mL after 10 and 30. min of sanitization, and this microbial reduction was dependent on the duration of the exposure to the ozonated water. E. coli exhibited the greatest reduction in CFU/mL (2.72-3.78. log) followed by S. aureus (2.14-3.19. log), C. albicans (1.44-2.14. log) and the spores of B. atrophaeus (1.01-1.98. log). Conclusion: The ozonated water was effective in reducing the CFU of E. coli, S. aureus, C. albicans and B. atrophaeus spores, suggesting that ozonated water can be used for the sanitization of dental instruments. © 2012 King Saud Bin Abdulaziz University for Health Sciences.
Resumo:
Mode of access: Internet.
Resumo:
Mode of access: Internet.