Active surveillance for dengue (DEN) virus infected mosquitoes can be an effective way to predict the risk of dengue infection in a given area. However, doing so may pose logistical problems if mosquitoes must be kept alive or frozen fresh to detect DEN virus. In an attempt to simplify mosquito processing, we evaluated the usefulness of a sticky lure and a seminested reverse-transcriptase polymerase chain reaction assay (RT-PCR) for detecting DEN virus RNA under laboratory conditions using experimentally infected Aedes aegypti (L.) mosquitoes. In the first experiment, 40 male mosquitoes were inoculated with 0.13 mul of a 10(4) pfu/ml DEN-2 stock solution. After a 7-d incubation period, the mosquitoes were applied to the sticky lure and kept at room temperatures of 23-30 degreesC. Following 7,10,14, and 28 d application, 10 mosquitoes each were removed from the lure pooled and assayed for virus. DEN virus nucleic acid was clearly detectable in all pools up to 28 d after death. A second study evaluated sensitivity and specificity using one, two, and five DEN-infected mosquitoes removed after 7, 10, 14, 21 and 30 d application and tested by RT-PCR. All four DEN serotypes were individually inoculated in mosquitoes and evaluated using the same procedures as experiment 1. The four serotypes were detectable in as few as one mosquito 30 d after application to the lure with no evidence of cross-reactivity. The combination of sticky lures and RT-PCR show promise for mosquito and dengue virus surveillance and warrant further evaluation.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We show here a simplified RT-PCR for identification of dengue virus types 1 and 2. Five dengue virus strains, isolated from Brazilian patients, and yellow fever vaccine 17DD as a negative control, were used in this study. C6/36 cells were infected and supernatants were collected after 7 days. The RT-PCR, done in a single reaction vessel, was carried out following a 1/10 dilution of virus in distilled water or in a detergent mixture containing Nonidet P40. The 50 µl assay reaction mixture included 50 pmol of specific primers amplifying a 482 base pair sequence for dengue type 1 and 210 base pair sequence for dengue type 2. In other assays, we used dengue virus consensus primers having maximum sequence similarity to the four serotypes, amplifying a 511 base pair sequence. The reaction mixture also contained 0.1 mM of the four deoxynucleoside triphosphates, 7.5 U of reverse transcriptase, 1U of thermostable Taq DNA polymerase. The mixture was incubated for 5 minutes at 37ºC for reverse transcription followed by 30 cycles of two-step PCR amplification (92ºC for 60 seconds, 53ºC for 60 seconds) with slow temperature increment. The PCR products were subjected to 1.7% agarose gel electrophoresis and visualized by UV light after staining with ethidium bromide solution. Low virus titer around 10 3, 6 TCID50/ml was detected by RT-PCR for dengue type 1. Specific DNA amplification was observed with all the Brazilian dengue strains by using dengue virus consensus primers. As compared to other RT-PCRs, this assay is less laborious, done in a shorter time, and has reduced risk of contamination

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Early diagnosis of dengue virus (DENV) infection is important for patient management and control of dengue outbreaks. The objective of this study was to analyze the usefulness of urine and saliva samples for early diagnosis of DENV infection by real time RT-PCR. Two febrile patients, who have been attended at the General Hospital of the School of Medicine of Ribeirao Preto, Sao Paulo University were included in the study. Serum, urine and saliva samples collected from both patients were subjected to real time RT-PCR for DENV detection and quantification. Dengue RNA was detected in serum, urine and saliva samples of both patients. Patient 1 was infected with DENV-2 and patient 2 with DENV-3. Data presented in this study suggest that urine and saliva could be used as alternative samples for early diagnosis of dengue virus infection when blood samples are difficult to obtain, e.g.,in newborns and patients with hemorrhagic syndromes.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The present work evaluated the diagnostic accuracy of detection of Dengue NS1 antigen employing two NS1 assays, an immunochromatographic assay and ELISA, in the diagnostic routine of Public Health laboratories. The results obtained with NS1 assay were compared with virus isolation and, in a subpopulation of cases, they were compared with the IgM-ELISA results obtained with convalescent samples. A total of 2,321 sera samples were analyzed by one of two NS1 techniques from March to October 2009. The samples were divided into five groups: groups I, II and III included samples tested by NS1 and virus isolation, and groups IV and V included patients with a first sample tested by NS1 and a second sample tested by IgM-ELISA. Sensitivity, specificity, positive and negative predictive values, Kappa Index and Kappa Concordance were calculated. The results showed that NS1 testing in groups I, II and III had high sensitivity (98.0%, 99.5% and 99.3%), and predictive values and Kappa index between 0.9 - 1.0. Groups IV and V only had Kappa Concordance calculated, since the samples were analyzed according to the presence of NS1 antigen or IgM antibody. Concordance of 92.1% was observed when comparing the results of NS1-negative samples with IgM-ELISA. Based on the findings, it is possible to suggest that the tests for NS1 detection may be important tools for monitoring the introduction and spread of Dengue serotypes.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Pro-inflammatory cytokines are believed to play an important role in the pathogenesis of dengue infection. This study reports cytokine levels in a total of 54 patients examined in Recife, State of Pernambuco, Brazil. Five out of eight patients who had hemorrhagic manifestations presented tumor necrosis factor-alpha (TNF-alpha) levels in sera which were statistically higher than those recorded for controls. In contrast, only one out of 16 patients with mild manifestations had elevated TNF-alpha levels. The levels of interleukin-6 (IL), IL-1beta tested in 24 samples and IL-12 in 30 samples were not significantly increased. Interferon-g was present in 10 out of 30 patients with dengue. The data support the concept that the increased level of TNF-alpha is related to the severity of the disease. Soluble TNF receptor p75 was found in most patients but it is unlikely to be related to severity since it was found with an equivalent frequency and levels in 15 patients with dengue fever and another 15 with dengue hemorrhagic fever.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Oral susceptibility and vertical transmission of dengue virus type 2 (DENV-2) in an Aedes albopictus sample from Rio de Janeiro was estimated. The infection (36.7%) and transmission (83.3%) rates for Ae. albopictus were higher than those of an Ae. aegypti colony used as control, 32.8 and 60%, respectively. Fourth instar larvae and females descendants of 48.5 and 39.1% of experimentally infected Ae. albopictus showed to harbor the virus. The oral susceptibility and the high capacity to assure vertical transmission exhibited by Ae. albopictus from Brazil reinforce that this species may play a role in the maintenance of the virus in nature and be a threat for dengue control in the country.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The detection of dengue virus serotypes from Aedes aegypti in Manaus, state of Amazonas was carried out using the reverse transcription-polymerase chain reaction technique. Fourteen pools out 82 (17.1%) were positive for DENV3, providing a minimal infection rate of 2.1% of all analyzed infected female specimens of three different areas of the city.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Mayaro virus (MAYV) is frequently reported in Pan-Amazonia. The aim of this study was to investigate the circulation of alphaviruses during a dengue outbreak in the state of Mato Grosso, Brazil. Serum samples from dengue-suspected patients were subjected to multiplex semi-nested reverse transcriptase polymerase chain reaction for 11 flaviviruses and five alphaviruses, to nucleotide sequencing and to viral isolation. MAYV was detected in 15 (2.5%) of 604 patients. Twelve were co-infected with dengue virus 4, which was isolated from 10 patients. The molecular detection of MAYV in dengue-suspected patients suggests that other arboviruses may be silently circulating during dengue outbreaks in Brazil.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The Aedes aegypti vector for dengue virus (DENV) has been reported in urban and periurban areas. The information about DENV circulation in mosquitoes in Colombian rural areas is limited, so we aimed to evaluate the presence of DENV in Ae. aegypti females caught in rural locations of two Colombian municipalities, Anapoima and La Mesa. Mosquitoes from 497 rural households in 44 different rural settlements were collected. Pools of about 20 Ae. aegypti females were processed for DENV serotype detection. DENV in mosquitoes was detected in 74% of the analysed settlements with a pool positivity rate of 62%. The estimated individual mosquito infection rate was 4.12% and the minimum infection rate was 33.3/1,000 mosquitoes. All four serotypes were detected; the most frequent being DENV-2 (50%) and DENV-1 (35%). Two-three serotypes were detected simultaneously in separate pools. This is the first report on the co-occurrence of natural DENV infection of mosquitoes in Colombian rural areas. The findings are important for understanding dengue transmission and planning control strategies. A potential latent virus reservoir in rural areas could spill over to urban areas during population movements. Detecting DENV in wild-caught adult mosquitoes should be included in the development of dengue epidemic forecasting models.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND: Dengue is the most important arboviral disease in the world. Dengue viruses (DENVs) have produced huge outbreaks in Brazil in the past 25 years with more than 5 million reported cases. During these epidemics, asymptomatic individuals infected with DENV could donate blood and serve as a source of virus dissemination in the community. Here, we studied the circulation of DENV in healthy individuals during an epidemic outbreak. STUDY DESIGN AND METHODS: The study included 500 serum samples from healthy blood donors collected at the Hemotherapy Center of Ribeirao Preto, Brazil, during a dengue outbreak. The presence of DENV RNA in the serum samples was screened by real-time reverse transcriptionpolymerase chain reaction (PCR). The virus serotype was determined by a heminested PCR procedure. A partial fragment of the NS5 gene sequence was used for phylogenetic analysis. RESULTS: DENV RNA was detected in the serum sample of 2 of 500 (0.4%) individuals. Both of them were infected with DENV-3 Genotype III, a virus that has been circulating in Brazil in the past decade. CONCLUSION: Individuals with asymptomatic DENV infection can be blood donors and serve as a source of virus dissemination in the community. Further studies are needed to determine the risk of recipient infection by DENV as a result of transfusion in Brazil, especially during epidemic periods.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In this communication we report a direct immunoassay for detecting dengue virus by means of a label-free interferometric optical detection method. We also demonstrate how we can optimize this sensing response by adding a blocking step able to significantly enhance the optical sensing response. The blocking reagent used for this optimization is a dry milk diluted in phosphate buffered saline. The recognition curve of dengue virus over the proposed surface sensor demonstrates the capacity of this method to be applied in Point of Care technology.