505 resultados para Degrelle, Rex


Relevância:

70.00% 70.00%

Publicador:

Resumo:

info:eu-repo/semantics/published

Relevância:

20.00% 20.00%

Publicador:

Resumo:

View of Rex Addison in study.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Extrahepatic portal vein thrombosis (EHPVT) is an important cause of portal hypertension in children. Rex shunt has been used successfully to treat these patients. Methods: We report our experience in 19 infants and children (5 months to 14 years) with HPVT eligible for a mesenteric-portal surgical shunt with left internal jugular vein autograft. Eight children had idiopathic EHPVT, nine had post-umbilical catheterization EHPVT, one had portal vein agenesis, and one had posttransplant EHPVT. Results: It was possible to perform the Rex shunt in all patients except for 8 of 9 cases in the post-umbilical catheterization EHPVT group. A Warren procedure was performed in 4 of those patients and a proximal splenorenal shunt in 1. Current follow-up ranges from 3 to 26 months. Shunt thrombosis occurred in one patient with portal vein agenesis and associated cardiac anomaly. Portal hypertension has significantly improved after surgery. None of our patients have experienced new bleeding episodes until now. Conclusions: The Rex shunt should be considered in the treatment of children with idiopathic EHPVT experiencing repeated gastrointestinal bleeding episodes refractory to endoscopic treatment. Nevertheless, the role of this operation for children with post-umbilical catheterization EHPVT is yet to be clearly evaluated. (C) 2011 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background/Purpose. Posttransplantation portal vein thrombosis (PVT) can have severe health consequences, and portal hypertension and other consequences of the long-term privation of portal inflow to the graft may be hazardous, especially in young children. The Rex shunt has been used successfully to treat PVT patients since 1998. In 2007, we started to perform this surgery in patients with idiopathic PVT and late posttransplantation PVT. Herein we have reported our experience with this technique in acute posttransplantation PVT. Methods. Three patients of ages 12, 15, and 18 months underwent cadaveric (n = 1) or living donor (n = 2) orthotopic liver transplantation (OLT). All patients had biliary atresia with portal vein hypoplasia; they developed acute PVT on the first postoperative day. They underwent a mesenteric-portal surgical shunt (Rex shunt) using a left internal jugular vein autograft (n = 2) or cadaveric iliac vein graft (n = 1) on the first postoperative day. Results. The 8-month follow-up has confirmed shunt patency by postoperative Doppler ultrasound. There have been no biliary complications to date. Conclusions. The mesenteric-portal shunt (Rex shunt) using an autograft of the left internal jugular or a cadaveric vein graft should be considered for children with acute PVT after OLT. These children usually have small portal veins; reanastomosis is often unsuccessful. In addition, this technique has the advantage to avoid manipulation of the hepatic hilum and biliary anastomosis. Although this study was based on a limited experience, we concluded that this technique is feasible, with great benefits to and low risks for these patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and Purpose. Late portal vein thrombosis (PVT) can be extremely well tolerated, although portal hypertension and other consequences of the long-term deprivation of portal inflow to the graft may be hazardous, especially in young children. Recently, the ""Rex shunt"" has been used successfully to treat these patients. We now report the initial experience with this novel technique. Methods. A 3-year-old girl with PVT at 7 months after whole organ cadaveric liver transplant displayed portal hypertension with an episode of gastrointestinal bleeding, requiring a mesenteric-portal surgical shunt (""Rex shunt"") using a left internal jugular vein autograft. Results. Upon current follow-up of 6 months, postoperative Doppler ultrasound confirmed shunt patency. Endoscopic status was significantly improved after surgery with resolution of portal hypertension. There was no recurrence of bleeding. Conclusions. The mesenteric-portal shunt (""Rex shunt""), using a left internal jugular vein autograft, should be considered for children with late PVT after liver transplantation. Although this is an initial experience, we may conclude that this technique is feasible, with great potential benefits and low risks for these patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Revista do IHA, N.3 (2007),pp.130-151

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Proyecto de migración y diseño de la infraestructura informática en una PYME, recogiendo sistemas diversos como son la publicación web junto a un gestor de contenidos, servicio de correo electrónico, etc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

[eng] Can Sophocles’ Oedipus Rex really be transformed into a love story, as in Steven Berkoff’s drama entitled Greek? This article will show that, although Greek may be viewed by some critics as simply a provocative drama by no means intended to justify incest, directors, actors and critics in the end become enthralled by the powerful love story that ensues between Eddy and his wife and mother. This perspective reveals that Berkoff’s adaptation, intended to portray the social degradation of 1980s Great Britain, is in reality a quite risky proposition since it represents a flat denial of the tragic awareness of contemporary men and women. However, if this is the case, the audience, apart from enjoying the performance of Berkoff’s drama, might question, even from a non-fundamentalist perspective within the classical tradition, to what degree it makes sense to take inspiration from a text by Sophocles that precisely illustrates the great tragic awareness of the ancient Greeks.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dedikaatio: Johannes Schmedeman.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Resumen basado parcialmente en el de la autora.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El objetivo de esta serie es desarrollar en los niños las habilidades para la lectura y la comprensión de textos, en doce niveles y mediante la narración de una historia distinta en cada uno de los libros que la componen. También se refuerza el vocabulario relacionado con el contenido de la historia y se acompaña de distintas actividades. En ésta, se narran las aventuras de la protagonista en una caja que le transporta en el tiempo hasta le época de los dinosaurios, y se incluye en el nivel nueve.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Compute grids are used widely in many areas of environmental science, but there has been limited uptake of grid computing by the climate modelling community, partly because the characteristics of many climate models make them difficult to use with popular grid middleware systems. In particular, climate models usually produce large volumes of output data, and running them also involves complicated workflows implemented as shell scripts. A new grid middleware system that is well suited to climate modelling applications is presented in this paper. Grid Remote Execution (G-Rex) allows climate models to be deployed as Web services on remote computer systems and then launched and controlled as if they were running on the user's own computer. Output from the model is transferred back to the user while the run is in progress to prevent it from accumulating on the remote system and to allow the user to monitor the model. G-Rex has a REST architectural style, featuring a Java client program that can easily be incorporated into existing scientific workflow scripts. Some technical details of G-Rex are presented, with examples of its use by climate modellers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

G-Rex is light-weight Java middleware that allows scientific applications deployed on remote computer systems to be launched and controlled as if they are running on the user's own computer. G-Rex is particularly suited to ocean and climate modelling applications because output from the model is transferred back to the user while the run is in progress, which prevents the accumulation of large amounts of data on the remote cluster. The G-Rex server is a RESTful Web application that runs inside a servlet container on the remote system, and the client component is a Java command line program that can easily be incorporated into existing scientific work-flow scripts. The NEMO and POLCOMS ocean models have been deployed as G-Rex services in the NERC Cluster Grid, and G-Rex is the core grid middleware in the GCEP and GCOMS e-science projects.