11 resultados para Defragmentation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dynamically reconfigurable systems have benefited from a new class of FPGAs recently introduced into the market, which allow partial and dynamic reconfiguration at run-time, enabling multiple independent functions from different applications to share the same device, swapping resources as needed. When the sequence of tasks to be performed is not predictable, resource allocation decisions have to be made on-line, fragmenting the FPGA logic space. A rearrangement may be necessary to get enough contiguous space to efficiently implement incoming functions, to avoid spreading their components and, as a result, degrading their performance. This paper presents a novel active replication mechanism for configurable logic blocks (CLBs), able to implement on-line rearrangements, defragmenting the available FPGA resources without disturbing those functions that are currently running.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fragmentation on dynamically reconfigurable FPGAs is a major obstacle to the efficient management of the logic space in reconfigurable systems. When resource allocation decisions have to be made at run-time a rearrangement may be necessary to release enough contiguous resources to implement incoming functions. The feasibility of run-time relocation depends on the processing time required to set up rearrangements. Moreover, the performance of the relocated functions should not be affected by this process or otherwise the whole system performance, and even its operation, may be at risk. Relocation should take into account not only specific functional issues, but also the FPGA architecture, since these two aspects are normally intertwined. A simple and fast method to assess performance degradation of a function during relocation and to speed up the defragmentation process, based on previous function labelling and on the application of the Euclidian distance concept, is proposed in this paper.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Reconfigurable computing experienced a considerable expansion in the last few years, due in part to the fast run-time partial reconfiguration features offered by recent SRAM-based Field Programmable Gate Arrays (FPGAs), which allowed the implementation in real-time of dynamic resource allocation strategies, with multiple independent functions from different applications sharing the same logic resources in the space and temporal domains. However, when the sequence of reconfigurations to be performed is not predictable, the efficient management of the logic space available becomes the greatest challenge posed to these systems. Resource allocation decisions have to be made concurrently with system operation, taking into account function priorities and optimizing the space currently available. As a consequence of the unpredictability of this allocation procedure, the logic space becomes fragmented, with many small areas of free resources failing to satisfy most requests and so remaining unused. A rearrangement of the currently running functions is therefore necessary, so as to obtain enough contiguous space to implement incoming functions, avoiding the spreading of their components and the resulting degradation of system performance. A novel active relocation procedure for Configurable Logic Blocks (CLBs) is herein presented, able to carry out online rearrangements, defragmenting the available FPGA resources without disturbing functions currently running.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Single procedure success rates of pulmonary vein isolation (PVI) in patients with paroxysmal atrial fibrillation (PAF) are still unsatisfactory. In patients with persistent atrial fibrillation (AF), ablation of complex fractionated atrial electrograms (CFAEs) after PVI results in improved outcomes. Objective We aimed to investigate if PAF-patients with intraprocedurally sustained AF after PVI might benefit from additional CFAE ablation. Methods A total of 1134 consecutive patients underwent a first catheter ablation procedure of PAF between June 2008 and December 2012. In most patients, AF was either not inducible or terminated during PVI. In 68 patients (6%), AF sustained after successful PVI. These patients were randomized to either cardioversion (PVI-alone group; n = 33) or additional CFAE ablation (PVI+CFAE group; n = 35) and followed up every 1–3 months and serial Holter recordings were also obtained. The primary end point was the recurrence of AF/atrial tachycardia (AT) after a blanking period of 3 months. Results Procedure duration (127 ± 6 minutes vs 174 ± 10 minutes), radiofrequency application time (44 ± 3 minutes vs 74 ± 5 minutes), and fluoroscopy time (26 ± 2 minutes vs 41 ± 3 minutes) were longer in the PVI+CFAE group (all P < .001). In 30 of 35 patients (86%) in the PVI+CFAE group, ablation terminated AF. There was no significant group difference with respect to freedom from AF/AT (22 of 33 [67%] vs 22 of 35 [63%]; P = .66). Subsequently, 10 of 11 patients in the PVI-alone group (91%) and 11 of 13 patients in PVI+CFAE group (85%) underwent repeat ablation (P = 1.00). Overall, 29 of 33 [88%] vs 30 of 35 [86%] patients (P = 1.00) were free from AF/AT after 1.4 ± 0.1 vs 1.4 ± 0.2 (P = .87) procedures. Conclusion Patients with sustained AF after PVI in a PAF cohort are rare. Regarding AF/AT recurrence, these patients did not benefit from further CFAE ablation compared to PVI alone, but are exposed to longer procedure duration, fluoroscopy time, and radiofrequency application time.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dynamically reconfigurable SRAM-based field-programmable gate arrays (FPGAs) enable the implementation of reconfigurable computing systems where several applications may be run simultaneously, sharing the available resources according to their own immediate functional requirements. To exclude malfunctioning due to faulty elements, the reliability of all FPGA resources must be guaranteed. Since resource allocation takes place asynchronously, an online structural test scheme is the only way of ensuring reliable system operation. On the other hand, this test scheme should not disturb the operation of the circuit, otherwise availability would be compromised. System performance is also influenced by the efficiency of the management strategies that must be able to dynamically allocate enough resources when requested by each application. As those resources are allocated and later released, many small free resource blocks are created, which are left unused due to performance and routing restrictions. To avoid wasting logic resources, the FPGA logic space must be defragmented regularly. This paper presents a non-intrusive active replication procedure that supports the proposed test methodology and the implementation of defragmentation strategies, assuring both the availability of resources and their perfect working condition, without disturbing system operation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Sustained atrial fibrillation (AF) is maintained by sites displaying high dominant frequency (DF). In patients (pts) with long-standing persistent AF (LS-pAF), their spatial distribution and the presence of a left-to-right atrial DF gradient remain poorly known. We hypothesized that the pre-ablation bi-atrial frequency characteristics of LS-pAF pts terminated within the left atrium (LT) are different from that of non terminated (NT) ones. Methods: 23 consecutive pts (59±7y, LS-pAF duration 19±12m) underwent stepwise catheter ablation (step-CA) consisting in pulmonary veins isolation, left atrial (LA) defragmentation, and right atrial (RA) ablations for non terminated AF. A quadripolar catheter (CAT) was placed into the RA appendage (RAA), a decapolar CAT into the coronary sinus (CS) and a duodecapolar CAT into the LA divided into 8 segments. For each segment, 20-sec of bipolar recording was acquired. The DF was defined as the largest peak in the power spectrum (3-15 Hz). The inter-atrial DF gradient was defined as the DF difference between LA and RA appendages. Results: LS-pAF was terminated in 83% (19/23) of the pts: 17 LT, 2 during RA ablation and 4 NT. The figure shows that before ablation bi-atrial DF values of LT pts are significantly lower than that of NT pts for each LA segment as well as for the RAA (p < 0.05). No significant LA-to-RA DF gradient was observed both for LT (0.3±0.5 Hz, p=ns) and NT (0.5±0.03 Hz, p=ns) pts. No significant difference in DF values was observed between LA segments. Conclusions: The lower DF of LT pts is suggestive of a higher organization within both atria compared to NT pts. Our findings suggest that low bi-atrial DF values, but not inter-atrial DF gradient, might be of interest for selecting LS-pAF candidates for sinus rhythm restoration by step-CA.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose Multiple organization indices (OIs) have been used to predict the outcome of stepwise catheter ablation (step-CA) in long-standing persistent AF (pers-AF), however with limited success. Our study aims at developing innovative OIs from baseline (BL, before ablation) ECG in order to predict the outcome of step-CA. Methods Fourteen consecutive patients (pts) (60±5 y, AF duration 21±9 m) underwent a step-CA consisting in pulmonary veins isolation, left atrial (LA) defragmentation and linear ablations, and right atrial (RA) ablations if non terminated. Chest lead V6 was placed in the back (V6b). After QRST cancellation from chest leads V1 to V6b, two OIs were computed to quantify the harmonic components of ECG atrial activity: 1) phase difference variance (PD) between the AF harmonic components as a measure of AF regularity, and 2) adaptive OI (AOI) evaluating the time evolution of the AF harmonic components. Both indices were compared to classical ones: a spectrum-based OI (SOI) and ECG AF cycle length (AFCL). Results Pers-AF was terminated into sinus rhythm or atrial tachycardia in 10/14 pts during step-CA, 8 during LA (LT), 2 during RA (RT) ablation, and 4 were non terminated (NT). The figure shows that LT was best separated from RT/NT before ablation by AOI computed on lead V1 (A) and PD from lead V6b (B) as compared to SOI and AFCL respectively. Conclusion Our results suggest that adaptive OIs computed before ablation perform better than classical OIs for separating LT from RT/NT pts. These findings are indicative of a higher baseline organization in LT pts that could be used to select candidates for the restoration of sinus rhythm by step-CA.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND Long-term success rates using ablation for persistent atrial fibrillation (AF) are disappointing and usually do not exceed 60%. OBJECTIVES This study sought to compare arrhythmia-free survival between pulmonary vein isolation (PVI) and a stepwise approach (full defrag) consisting of PVI, ablation of complex fractionated electrograms, and additional linear ablation lines in the setting of atrial tachycardias (AT) in patients with persistent AF after PVI. METHODS From November 2010 to February 2013, 205 patients (151 men; 61.7 ± 10.2 years of age) underwent de novo ablation for persistent AF. Subsequently, patients were prospectively randomized to either PVI alone (n = 78) or full defrag (n = 75), with 52 patients not randomized due to AF termination with the original PVI. The primary endpoint was recurrence of any AT after a blanking period of 3 months. RESULTS During the entire study, 241 ablations were performed (mean: 1.59 in the PVI-alone group, 1.55 in the full-defrag group). With the stepwise approach, termination of AF occurred in 45 (60%) patients. However, arrhythmia-free survival did not differ whether patients underwent single or multiple procedures (p = 0.468). Procedure duration, fluoroscopy time, and radiofrequency duration were significantly longer in the full-defrag group (all p < 0.001). CONCLUSIONS A stepwise approach aimed at AF termination does not seem to provide additional benefit over PVI alone in patients with persistent AF, but it is associated with significantly longer procedural and fluoroscopic duration as well as radiofrequency application time. (The Randomized Catheter Ablation of Persist End Atrial Fibrillation Study [CHASE-AF]; NCT01580124).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Catheter ablation of complex fractionated atrial electrograms (CFAE), also known as defragmentation ablation, may be considered for the treatment of persistent atrial fibrillation (AF) beyond pulmonary vein isolation (PVI). Concomitant antiarrhythmic drug (AAD) therapy is common, but the relevance of AAD administration and its optimal timing during ablation remain unclear. Therefore, we investigated the use and timing of AADs during defragmentation ablation and their possible implications for AF termination and ablation success in a large cohort of patients. Retrospectively, we included 200 consecutive patients (age: 61 ± 12 years, LA diameter: 47 ± 8 mm) with persistent AF (episode duration 47 ± 72 weeks) who underwent de novo ablation including CFAE ablation. In all patients, PVI was performed prior to CFAE ablation. The use and timing of AADs were registered. The follow-ups consisted of Holter ECGs and clinical visits. Termination of AF was achieved in 132 patients (66 %). Intraprocedural AADs were administered in 168/200 patients (84 %) 45 ± 27 min after completion of PVI. Amiodarone was used in the majority of the patients (160/168). The timing of AAD administration was predicted by the atrial fibrillation cycle length (AFCL). At follow-up, 88 patients (46 %) were free from atrial arrhythmia. Multivariate logistic regression analysis revealed that administration of AAD early after PVI, LA size, duration of AF history, sex and AFCL were predictors of AF termination. The administration of AAD and its timing were not predictive of outcome, and age was the sole independent predictor of AF recurrence. The administration of AAD during ablation was common in this large cohort of persistent AF patients. The choice to administer AAD therapy and the timing of the administration during ablation were influenced by AFCL, and these factors did not significantly influence the moderate single procedure success rate in this retrospective analysis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AIMS Pulmonary vein isolation (PVI) is an effective treatment option for paroxysmal atrial fibrillation (PAF). Reconnection of pulmonary veins (PVs) is the predominant cause for recurrence of PAF. However, treatment of patients with recurrence of PAF despite isolated PV in the absence of extra-PV foci remains challenging. METHODS AND RESULTS Of 265 patients undergoing repeat catheter ablation (CA) for recurrence of PAF 21 (8%) patients (14 men, age 58 ± 14 years) showed no reconnection of PV. Therefore, inducibility of sustained atrial arrhythmias was tested. If sustained atrial fibrillation (AF) or sustained atrial tachycardia (AT) was induced, patients underwent CA. During follow-up (FU), Holter- and Tele-electrocardiogram were performed. In 19 (91%) of 21 patients, sustained atrial arrhythmias [16 (84%) AF; 3 (15%) patients AT] were induced. One patient showed PAF. Eighteen patients underwent CA aiming for termination of induced arrhythmia. In 14 (77%) patients, termination into sinus rhythm was achieved. Despite extensive CA, three (16%) patients were externally cardioverted. No periprocedural complications occurred. During 21.2 ± 6.8-month FU, 10 (53%) patients were free of any arrhythmia. Paroxysmal atrial fibrillation recurred in 4 (21%) and AT in 5 (26%) patients. One patient showed persistent AF. Repeat CA was scheduled and successfully performed for these patients. CONCLUSION In patients with recurrence of PAF despite isolated PV, termination of induced atrial arrhythmias can be achieved in most patients by defragmentation and AT ablation. Moreover, this ablation strategy results in favourable mid-term outcome results.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this research was to explore a new way of experiencing a performance space using the portability and flexibility of a cargo container. Since the 17th century there has been a split between theater, as a written work, and architecture. Theater has lost its founding essence becoming more about the structure and less about the performance. Contemporary theater designs came through the development of street performances, which developed into theater types such as the Black Box and lately video and projection screening. With the exploration of kinetic uses in architecture and defragmentation of a cargo container there is a new step on the development of theater design. Using a cargo container gave me a familiar object with specific dimensions to start my exploration as well as the possibility of having the theater transported to many sites. The findings demonstrate that there are many unexplored possibilities to create a performance space outside the conventional theater that can promote new types of performances as well as the use of new technologies of video and projection.