968 resultados para Deformation rate
Resumo:
In this research, five types of polymer repair materials were selected for investigation of the influence of sample shape, deformation rate and test temperature on the mechanical properties determined with an uniaxial tensile test. The results showed the clear effect of measurement conditions on tensile strength, elongation and modulus of elasticity. The highest tensile strength and modulus of elasticity were exhibited by epoxy resin for the filling of concrete cracks, which achieved 1% elongation. The lowest coefficient of dispersion characterized the results of tensile test carried out using dumbbell samples at a deformation rate of 50 mm/min. The effect of temperature varied with the material type.
Resumo:
Dissertação de mestrado integrado em Engenharia Mecânica
Resumo:
We study the damage enhanced creep rupture of disordered materials by means of a fiber bundle model. Broken fibers undergo a slow stress relaxation modeled by a Maxwell element whose stress exponent m can vary in a broad range. Under global load sharing we show that due to the strength disorder of fibers, the lifetime ʧ of the bundle has sample-to-sample fluctuations characterized by a log-normal distribution independent of the type of disorder. We determine the Monkman-Grant relation of the model and establish a relation between the rupture life tʄ and the characteristic time tm of the intermediate creep regime of the bundle where the minimum strain rate is reached, making possible reliable estimates of ʧ from short term measurements. Approaching macroscopic failure, the deformation rate has a finite time power law singularity whose exponent is a decreasing function of m. On the microlevel the distribution of waiting times is found to have a power law behavior with m-dependent exponents different below and above the critical load of the bundle. Approaching the critical load from above, the cutoff value of the distributions has a power law divergence whose exponent coincides with the stress exponent of Maxwell elements
Resumo:
Na cirurgia de reconstrução do ligamento cruzado anterior do joelho, os enxertos de tendões autólogos são a principal opção como substitutos ligamentares. Entretanto, uma das razões da falha da reconstrução ligamentar com tecidos moles é o estiramento ou elongamento do enxerto com o tempo. Neste trabalho, foram ensaiados oito tendões do músculo grácil e oito do músculo semitendinoso humanos, obtidos de quatro cadáveres do sexo masculino, com idade média de 24,5 anos. Cada tendão foi submetido a uma deformação relativa constante de 2,5% durante 600 s, com registro contínuo do relaxamento de força. A seguir, o tendão retornava ao seu comprimento inicial e era mantido num período de repouso de 300 s. Após este intervalo, um segundo ensaio, semelhante ao primeiro, era realizado. A velocidade de carregamento empregada foi de 10% do comprimento inicial do corpo de prova por segundo. Foram obtidos valores de força inicial, com 300 s e 600 s nos dois ensaios. A análise estatística sugere um comportamento mecânico mais uniforme para o tendão do músculo semitendinoso quando comparado ao tendão do músculo grácil.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Spark Plasma Sintering (SPS) is a promising rapid consolidation technique that allows a better understanding and manipulating of sintering kinetics and therefore makes it possible to obtain Si3N4-based ceramics with tailored microstructures, consisting of grains with either equiaxed or elongated morphology. The presence of an extra liquid phase is necessary for forming tough interlocking microstructures in Yb/Y-stabilised α-sialon by HP. The liquid is introduced by a new method, namely by increasing the O/N ratio in the general formula RExSi12-(3x+n)Al3x+nOnN16-n while keeping the cation ratios of RE, Si and Al constant. Monophasic α-sialon ceramics with tailored microstructures, consisting of either fine equiaxed or elongated grains, have been obtained by using SPS, whether or not such an extra liquid phase is involved. The three processes, namely densification, phase transformation and grain growth, which usually occur simultaneously during conventional HP consolidation of Si3N4-based ceramics, have been precisely followed and separately investigated in the SPS process. The enhanced densification is attributed to the non-equilibrium nature of the liquid phase formed during heating. The dominating mechanism during densification is the enhanced grain boundary sliding accompanied by diffusion- and/or reaction-controlled processes. The rapid grain growth is ascribed to a dynamic ripening mechanism based on the formation of a liquid phase that is grossly out of equilibrium, which in turn generates an extra chemical driving force for mass transfer. Monophasic α-sialon ceramics with interlocking microstructures exhibit improved damage tolerance. Y/Yb- stabilised monophasic α-sialon ceramics containing approximately 3 vol% liquid with refined interlocking microstructures have excellent thermal-shock resistance, comparable to the best β-sialon ceramics with 20 vol% additional liquid phase prepared by HP. The obtained sialon ceramics with fine-grained microstructure show formidably improved superplasticity in the presence of an electric field. The compressive strain rate reaches the order of 10-2 s-1 at temperatures above 1500oC, that is, two orders of magnitude higher than that has been realised so far by any other conventional approaches. The high deformation rate recorded in this work opens up possibilities for making ceramic components with complex shapes through super-plastic forming.
Resumo:
In Gesteinen, die bei schwach- bis mittelgradiger Metamorphose deformiert wurden, sind Mikrostrukturen, wie z.B. undulöse Auslöschung, Subkörner und kristallographische Regelungen, typisch. Sie werden i.a. als das Resultat eines kristallplastischen Deformationsprozesses interpretiert. Das häufige Auftreten dieser Strukturen führte zu der Annahme, daß kristallplastische Deformationsprozesse zu den dominierenden duktilen Deformationsmechanismen während der Erdkrustendeformation gehören.Die vorliegende Arbeit beschäftigt sich mit Experimenten, bei denen die zeitabhängige kata-klastische Deformation polykristalliner, kompaktierter Aggregatproben des sehr gut löslichen, elastisch/spröden Salzes Natriumchlorat (NaClO3) untersucht wurde. Dieses Salz wurde als Analogmaterial gesteinsbildender Minerale wie Quarz und Feldspat ausgewählt. Es wurde nun untersucht, ob und in welcher Weise spröde Deformationsmechanismen in Anwesenheit von Wasser scheinbar kristall-plastische Mikrostrukturen hervorrufen können.Aus den Versuchen ergibt sich nun die Folgerung, daß scheinbar kristallplastisch erzeugte Mikrostrukturen wie Subkörner auch durch spröde zeitunabhängige Risse und subkritische (langsame) Kataklase entstehen können. Diese Erkenntnisse sind wichtig für das rheologische Verhalten der Erdkruste und somit auch für Modellierungen der Erdkrustendeformation. Ihre Betrachtung und Übertragung auf die Deformationsstrukturen der natürlich deformierten kontinentalen, oberkrustalen Gesteine der Erde würde die Interpretation der Mikrostrukturen in diesen Bereichen stark ändern. Dies hätte eine wesentliche Änderung auf den Verlauf der Gesteinsfestigkeitskurven in den Spannungsprofilen der Erdoberkruste zur Folge.
Resumo:
We carried out an experiment to estimate in-situ stresses at ODP Hole 794C (water depth: 2809 m) from the basaltic core samples by deformation rate analysis (DRA). Site 794 is located at the northern end of the Yamato Basin and 70 km west of the eastern Japan Sea intraplate or interplate convergent zone. Stress previously applied to a rock specimen is identified in the inelastic strain behavior of the specimen under uniaxial compression by the method used. Natural remanent magnetization of the sample was also measured to get a reference for the orientation of the horizontal stresses. The vertical, maximum, and minimum horizontal in-situ stresses estimated at a depth of 582 mbsf are 36.4, 43.1, and 31.2 MPa, respectively. The average of the largest and the least horizontal stresses is nearly equal in value to the vertical stress. This suggests that the site is in the stress field of the strike slip regime at the depth, while the stress field of the reverse fault regime has been estimated from the focal mechanism solutions of the earthquakes whose hypocenters are located near or on the convergent boundary. The directions of the largest and the least horizontal stress are estimated to be northeast-southwest and in northwest-southeast, respectively, in taking account of rotation tectonics of the Japan Sea since its formation. The directions of the largest and the least horizontal stresses are opposite to those determined from the earthquakes. These discrepancies of our results with those from earthquakes may be due mainly to the fact that the site is not in the convergent zone.
Resumo:
This paper presents an analysis of the performance of TerraSAR-X for subsidence monitoring in urban areas. The city of Murcia has been selected as a test-site due to its high deformation rate and the set of extensometers deployed along the city that provide validation data. The obtained results have been compared with those obtained from ERS/ENVISAT data belonging to the same period and validated with the in-situ measurements.
Resumo:
In order to determine the shear parameters of the forearc sedimentary strata drilled during Ocean Drilling Program Leg 186, West Pacific Seismic Network, Japan Trench, eight whole-round samples were selected from different depths in the drilled sections of Sites 1150 and 1151. Whereas Site 1150 lays above the seismically active part of the subduction zone, Site 1151 is situated in an aseismic zone. The aim of the triaxial tests was, apart from determination of the static stress strain behavior of the sediments, to test the hypothesis that the static stress strain parameter could differ for each sites. In order to simulate undrained deformation conditions according to the high clay mineral content of the strata, consolidated undrained shear tests were performed in a triaxial testing setup. Measurements of water content, grain density, organic content, and microtextural investigations under the scanning electron microscope (SEM) accompanied the compression experiments. After the saturation and consolidation stages were completed, failure occurred in the compression stage of the experiments at peak strengths of 280-7278 kPa. The stiffness moduli calculated for each sample from differential stress vs. strain curves show a linear relationship with depth and range between 181 and 5827 kPa. Under the SEM, the artificial fault planes of the tested specimen only show partial alignment of clay minerals because of the high content of microfossils.
Resumo:
The dynamics of drop formation and pinch-off have been investigated for a series of low viscosity elastic fluids possessing similar shear viscosities, but differing substantially in elastic properties. On initial approach to the pinch region, the viscoelastic fluids all exhibit the same global necking behavior that is observed for a Newtonian fluid of equivalent shear viscosity. For these low viscosity dilute polymer solutions, inertial and capillary forces form the dominant balance in this potential flow regime, with the viscous force being negligible. The approach to the pinch point, which corresponds to the point of rupture for a Newtonian fluid, is extremely rapid in such solutions, with the sudden increase in curvature producing very large extension rates at this location. In this region the polymer molecules are significantly extended, causing a localized increase in the elastic stresses, which grow to balance the capillary pressure. This prevents the necked fluid from breaking off, as would occur in the equivalent Newtonian fluid. Alternatively, a cylindrical filament forms in which elastic stresses and capillary pressure balance, and the radius decreases exponentially with time. A (0+1)-dimensional finitely extensible nonlinear elastic dumbbell theory incorporating inertial, capillary, and elastic stresses is able to capture the basic features of the experimental observations. Before the critical "pinch time" t(p), an inertial-capillary balance leads to the expected 2/3-power scaling of the minimum radius with time: R-min similar to(t(p)-t)(2/3). However, the diverging deformation rate results in large molecular deformations and rapid crossover to an elastocapillary balance for times t>t(p). In this region, the filament radius decreases exponentially with time R-min similar to exp[(t(p)-t)/lambda(1)], where lambda(1) is the characteristic time constant of the polymer molecules. Measurements of the relaxation times of polyethylene oxide solutions of varying concentrations and molecular weights obtained from high speed imaging of the rate of change of filament radius are significantly higher than the relaxation times estimated from Rouse-Zimm theory, even though the solutions are within the dilute concentration region as determined using intrinsic viscosity measurements. The effective relaxation times exhibit the expected scaling with molecular weight but with an additional dependence on the concentration of the polymer in solution. This is consistent with the expectation that the polymer molecules are in fact highly extended during the approach to the pinch region (i.e., prior to the elastocapillary filament thinning regime) and subsequently as the filament is formed they are further extended by filament stretching at a constant rate until full extension of the polymer coil is achieved. In this highly extended state, intermolecular interactions become significant, producing relaxation times far above theoretical predictions for dilute polymer solutions under equilibrium conditions. (C) 2006 American Institute of Physics
Resumo:
Behavior of granular material subjected to repeated load triaxial compression tests is characterized by a model based on rate process theory. Starting with the Arrhenius equation from chemical kinetics, the relationship of temperature, shear stress, normal stress and volume change to deformation rate is developed. The proposed model equation includes these factors as a product of exponential terms. An empirical relationship between deformation and the cube root of the number of stress applications at constant temperature and normal stress is combined with the rate equation to yield an integrated relationship of temperature, deviator stress, confining pressure and number of deviator stress applications to axial strain. The experimental program consists of 64 repeated load triaxial compression tests, 52 on untreated crushed stone and 12 on the same crushed stone material treated with 4% asphalt cement. Results were analyzed with multiple linear regression techniques and show substantial agreement with the model equations. Experimental results fit the rate equation somewhat better than the integrated equation when all variable quantities are considered. The coefficient of shear temperature gives the activation enthalpy, which is about 4.7 kilocalories/mole for untreated material and 39.4 kilocalories/mole for asphalt-treated material. This indicates the activation enthalpy is about that of the pore fluid. The proportionality coefficient of deviator stress may be used to measure flow unit volume. The volumes thus determined for untreated and asphalt-treated material are not substantially different. This may be coincidental since comparison with flow unit volumes reported by others indicates flow unit volume is related to gradation of untreated material. The flow unit volume of asphalt-treated material may relate to asphalt cement content. The proposed model equations provide a more rational basis for further studies of factors affecting deformation of granular materials under stress similar to that in pavement subjected to transient traffic loads.
Resumo:
Background: Color Doppler myocardial imaging (CDMI) allows the calculation of local longitudinal or radial strain rate (SR) and strain (epsilon). The aims of this study were to determine the feasibility and reproducibility of longitudinal and radial SR and epsilon in neonates during the first hours of life and to establish reference values. Methods: Data were obtained from 55 healthy neonates (29 male; mean age, 20 +/- 14 hours; mean birth weight, 3,174 +/- 374 g). Apical and parasternal views quantified regional longitudinal and radial SR and epsilon in differing ventricular wall segments. Values at peak systole, early diastole, and late diastole were calculated from the extracted curves. CDMI data acquired at 300 +/- 50 frames/s were analyzed offline. Three consecutive cardiac cycles were measured during normal respiration. The timing of specific systolic or diastolic regional events was determined. Multiple comparisons between walls and segments were made. Results: Left ventricular (LV) longitudinal deformation showed basal differences compared with apical segments within one specific wall. Right ventricular (RV) longitudinal deformation was not homogeneous, with significant differences between basal and apical segments. Longitudinal 3 values were higher in the RV free basal and middle wall segments compared with the left ventricle. In the RV free wall apical segment, longitudinal SR and 3 were maximal. LV systolic SR and epsilon values were higher radially compared with longitudinally (radial peak systolic SR midportion, 2.9 +/- 0.6 s(-1); radial peak systolic epsilon 53.8 +/- 19%; longitudinal peak systolic SR midportion, -1.8 +/- 0.5 s(-1); longitudinal peak systolic epsilon, -24.8 +/- 3%; P < .01). Longitudinal systolic epsilon and SR interobserver variability values were 1.2% and 0.7%, respectively. Conclusion: Ultrasound-based SR and 3 imaging is a practical and reproducible clinical technique in neonates, allowing the calculation of regional longitudinal and radial deformation in RV and LV segments. These regional SR and epsilon indices represent new, noninvasive parameters that can quantify normal neonate regional cardiac function. Independent from visual interpretation, they can be used as reference values for diagnosis in ill neonates. (J Am Soc Echocardiogr 2009;22:369-375.)