16 resultados para DVR


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work presents a case study on technology assessment for power quality improvement devices. A system compatibility test protocol for power quality mitigation devices was developed in order to evaluate the functionality of three-phase voltage restoration devices. In order to validate this test protocol, the micro-DVR, a reduced power development platform for DVR (dynamic voltage restorer) devices, was tested and the results are discussed based on voltage disturbances standards. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work presents a case study on technology assessment for power quality improvement devices. A system compatibility test protocol for power quality mitigation devices was developed in order to evaluate the functionality of three-phase voltage restoration devices. In order to validate this test protocol, the micro-DVR, a reduced power development platform for DVR (dynamic voltage restorer) devices, was tested and the results are discussed based on voltage disturbances standards. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work presents a case study on technology assessment for power quality devices. A system compatibility test protocol for power quality mitigation devices was developed in order to evaluate the functionality of three-phase voltage restoration devices. In order to case test this test protocol, a development platform with reduced power for DVR (Dynamic Voltage Restorer), the Micro-DVR, was tested, and results were discussed based on voltage disturbances standards. ©2008 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Vista la preoccupante situazione infortuni sul lavoro in Italia che non accenna a migliorare, in questo elaborato è possibile trovare uno standard di DVR da potere applicare e adeguare alle aziende presenti nel territorio italiano. In particolare è stato esaminato il caso di Energy Multiservizi, azienda multiservizio con sede operativa a Castiglione dei Pepoli (BO). L’obiettivo è la redazione del DVR per tale impresa. I dati raccolti sono frutto di collaborazione tra Datore di Lavoro (DL), Responsabile dei Lavoratori per la Sicurezza (RLS), Responsabile del Servizio di Prevenzione e Protezione (RSPP) e del Medico Competente (MC) i quali si sono impegnati nel corso dei sopralluoghi per avere misurazioni il più affidabili possibile e di discutere riguardo le proposte di miglioramento riportate nel corso dell’intero elaborato. Nel documento è possibile trovare riferimenti normativi, richiami a norme tecniche, metodi di valutazione quantitativi e qualitativi per il calcolo dei rischi maggiormente presenti nei luoghi di lavoro. I rischi che verranno stimati e calcolati per l’azienda in esame sono: Rischio stress Lavoro Correlato, Rischio al Videoterminale e Postazioni di lavoro, Rischio chimico, Rischio Elettrico, Rischio Meccanico, Rischio da Rumore, Rischio da Vibrazioni, Rischio da sovraccarico Biomeccanico ed infine il Rischio Microclimatico. Applicando le metodologie presenti nell’elaborato è stato possibile fornire ad Energy Multiservizi un DVR aggiornato, completo, che utilizzi norme e metodologie ancora in vigore e che abbia stimato tutti i rischi a cui sono sottoposti i lavoratori in azienda

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents a predictive optimal matrix converter controller for a flywheel energy storage system used as Dynamic Voltage Restorer (DVR). The flywheel energy storage device is based on a steel seamless tube mounted as a vertical axis flywheel to store kinetic energy. The motor/generator is a Permanent Magnet Synchronous Machine driven by the AC-AC Matrix Converter. The matrix control method uses a discrete-time model of the converter system to predict the expected values of the input and output currents for all the 27 possible vectors generated by the matrix converter. An optimal controller minimizes control errors using a weighted cost functional. The flywheel and control process was tested as a DVR to mitigate voltage sags and swells. Simulation results show that the DVR is able to compensate the critical load voltage without delays, voltage undershoots or overshoots, overcoming the input/output coupling of matrix converters.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia Informática

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Es presenta un estudi de l’avaluació dels resultats en el tractament de les fractures distals de radi durant el període de temps 2008-2010 a l’Hospital Sant Joan de Reus. A partir del estudi radiogràfic i biomecànic de les fractures i mitjançant la classificació de Fernández s’avalua el tractament realitzat, en termes de funcionalitat i resultat radiogràfic posterior. Els tractament utilitzats van ser: la reducció tancada i immobilització amb guix antebraquiopalmar (ABP), la reducció tancada i fixació percutánia amb agulles de Kirchner, la reducció oberta per abordatge palmar i fixació amb placa volar DVR (Distal Volar Radius). Els resultat s’avaluen amb l’escala de valoració de Gartland modificada. Fent una revisió actualitzada de la literatura i l’evidencia que existeix pel tractament de cada tipus de fractura.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objetivos: a) avaliar a contribuição de um novo coeficiente, o CEF50 (FEF50/0,5CVF), medido através da curva fluxo-volume, no diagnóstico dos distúrbios ventilatórios; b) testar o CEF50 na diferenciação dos grupos Normais, DVO, DVR; c) estabelecer pontos de corte para cada um dos diagnósticos funcionais e valores de probabilidade para cada diagnóstico a partir de valores individuais. Métodos: estudo transversal, prospectivo, com análise de testes de função pulmonar realizados no HCPA no período de janeiro a dezembro de 2003. Foram coletados dados demográficos e analisados CVF, VEF1, VEF1/CVF, VEF1/CV, CV, VR, CPT, FEF50, FEF75 e DCO. Os pacientes foram divididos conforme o diagnóstico funcional em Normais, DVO e DVR. Foi calculado o CEF50 (FEF50/0,5CVF) nos grupos e as médias foram comparadas. Para correlacionar o CEF50 com o CEF1, utilizou-se a correlação de Pearson. Os pacientes foram, então, redivididos em obstrutivos (Dobst) e não-obstrutivos (dnobst) e foram calculadas as razões de verossimilhança (RV) para diferentes pontos de corte. Resultados: Foram estudados 621 pacientes com idade média de 55,8  14,7 anos. O CEF50 foi diferente nos grupos Normal (2,100,82), DVR (2,551,47) e DVO (0,560,29) (p<0,001). O CEF50 mostrou uma correlação positiva com o CEF1 nos pacientes obstrutivos (r=0,83). O cálculo das RV mostrou que valores abaixo de 0,79 mostraram-se fortes indicadores de DVO e valores acima de 1,33 praticamente afastam esse diagnóstico. Conclusão: O CEF50 (FEF50 / 0,5CVF) é um parâmetro útil no diagnóstico diferencial dos distúrbios ventilatórios, correlacionando-se positivamente com o CEF1.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper deals with the design and analysis of a Dynamic Voltage Restorer output voltage control. Such control is based on a multiloop strategy, with an inner current PID regulator and an outer P+Resonant voltage controller. The inner regulator is applied on the output inductor current. It will be also demonstrated how the load current behavior may influence in the DVR output voltage, which. justifies the need for the resonant controller. Additionally, it will be discussed the application of a modified algorithm for the identification of the DVR voltage references, which is based on a previously presented positive sequence detector. Since the studied three-phase DVR is assumed to be based on three identical H-bridge converters, all the analysis and design procedures were realized by means of single-phase equivalent circuits. The discussions and conclusions are supported by theoretical calculations, nonlinear simulations and some experimental results.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper deals with the design and analysis of a Dynamic Voltage Restorer output voltage control. Such control is based on a multiloop strategy, with an inner current PID regulator and an outer P+Resonant voltage controller. The inner regulator is applied on the output inductor current. It will be also demonstrated how the load current behavior may influence in the DVR output voltage, which justifies the need for the resonant controller. Additionally, it will be discussed the application of a modified algorithm for the identification of the DVR voltage references, which is based on a previously presented positive sequence detector. Since the studied three-phase DVR is assumed to be based on three identical H-bridge converters, all the analysis and design procedures were realized by means of single-phase equivalent circuits. The discussions and conclusions are supported by theoretical calculations, nonlinear simulations and some experimental results. ©2008 IEEE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Voltage reference generation is an important issue on electronic power conditioners or voltage compensators connected to the electric grid. Several equipments, such as Dynamic Voltage Restorers (DVR), Uninterruptable Power Supplies (UPS) and Unified Power Quality Conditioners (UPQC) need a proper voltage reference to be able to compensate electric network disturbances. This work presents a new reference generator's algorithm, based on vector algebra and digital filtering techniques. It is particularly suited for the development of voltage compensators with energy storage, which would be able to mitigate steady state disturbances, such as waveform distortions and unbalances, and also transient disturbances, like voltage sags and swells. Simulation and experimental results are presented for the validation of the proposed algorithm. © 2011 IEEE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: The main manifestation of hyperglycaemia during pregnancy is gestational diabetes mellitus. It can herald diabetes mellitus type 2 and its deleterious long-term effects, such as hypertension and cardiovascular disease. The aim of this study was to assess diastolic function in women with gestational diabetes mellitus, one of the first signs of future cardiovascular disease.Methods: A total of 21 women with gestational diabetes mellitus and 23 healthy pregnant women (control group) between 34 and 37weeks of gestation underwent echocardiographic assessment. The diagnosis of gestational diabetes mellitus was made in agreement with the American Diabetes Association criteria. Echocardiographic images obtained were analysed according to the criteria of the American Society of Echocardiography. Data were analysed using Pearson correlation coefficient, analysis of variance and Student's t-test.Results: Women with gestational diabetes mellitus had higher posterior wall and interventricular septum thickness, increased left ventricular mass and left ventricular mass index, lower early diastolic annular velocity and early diastolic annular velocity/late diastolic annular velocity ratio. There was a positive correlation between left ventricular mass index and fasting glucose and pregnancy body mass index.Conclusion: Patients with gestational diabetes mellitus seem to have a different diastolic profile as well as a mildly dysfunctional pattern on echocardiogram, which may show a need for greater glycaemic control.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Considering the importance of the esthetic and the adequate register of vertical dimension (VD) to the oral rehabilitation, this study had as aims the analysis and comparison of two methods to get VD (Pleasure and Willis), functional space (FE), acquisition and correlation of facial and dental measurements. To do this, rest (RVD) and occlusal vertical dimension (OVD) and FE were achieved from the 30 students of the Federal University of Goias College of Dentistry. Following that, dental measurements of height and of the superior central incisors (SCI) and canine distance were registered. A facial analysis was performed to get the intercomissura, interalar, interpupilar, intercantal distance, besides register parameters as coincidence of dental and facial line, type of smile, face and SCI forms, and mastication type. The collected data were tabulated, compared by medias and standard deviations, and submitted to non-parametrical statistical analysis of Kruskal-Wallis and .Mann-Whitney with 5% of probability. The results doesn’t indicated statistical significant difference between FE of the two techniques. The measures of facial analysis are comparable with literature published data’s, but can’t be used as a parameter to the selection of intercanine distance. In 56.7% of the cases, there were coincidences of face and SCI forms, which could be a viable parameter in the selection of acrylic resin artificial tooth.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nicotine addiction is a major public health problem, resulting in primary glutamatergic dysfunction. We measured the glutamate receptor binding in the human brain and provided direct evidence for the abnormal glutamate system in smokers. Because antagonism of the metabotropic glutamate receptor 5 (mGluR5) reduced nicotine self-administration in rats and mice, mGluR5 is suggested to be involved in nicotine addiction. mGluR5 receptor binding specifically to an allosteric site was observed by using positron emission tomography with [(11)C]ABP688. We found a marked global reduction (20.6%; P < 0.0001) in the mGluR5 distribution volume ratio (DVR) in the gray matter of 14 smokers. The most prominent reductions were found in the bilateral medial orbitofrontal cortex. Compared with 14 nonsmokers, 14 ex-smokers had global reductions in the average gray matter mGluR5 DVR (11.5%; P < 0.005), and there was a significant difference in average gray matter mGluR5 DVR between smokers and ex-smokers (9.2%; P < 0.01). Clinical variables reflecting current nicotine consumption, dependence and abstinence were not correlated with mGluR5 DVR. This decrease in mGluR5 receptor binding may be an adaptation to chronic increases in glutamate induced by chronic nicotine administration, and the decreased down-regulation seen in the ex-smokers could be due to incomplete recovery of the receptors, especially because the ex-smokers were abstinent for only 25 wk on average. These results encourage the development and testing of drugs against addiction that directly target the glutamatergic system.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Obsessive-compulsive disorder (OCD) is a disabling, mostly chronic, psychiatric condition with significant social and economic impairments and is a major public health issue. However, numerous patients are resistant to currently available pharmacological and psychological interventions. Given that recent animal studies and magnetic resonance spectroscopy research points to glutamate dysfunction in OCD, we investigated the metabotropic glutamate receptor 5 (mGluR5) in patients with OCD and healthy controls. We determined mGluR5 distribution volume ratio (DVR) in the brain of ten patients with OCD and ten healthy controls by using [11C]ABP688 positron-emission tomography. As a clinical measure of OCD severity, the Yale-Brown Obsessive Compulsive Scale (Y-BOCS) was employed. We found no significant global difference in mGluR5 DVR between patients with OCD and healthy controls. We did, however, observe significant positive correlations between the Y-BOCS obsession sub-score and mGluR5 DVR in the cortico-striatal-thalamo-cortical brain circuit, including regions of the amygdala, anterior cingulate cortex, and medial orbitofrontal cortex (Spearman's ρ's⩾ = 0.68, p < 0.05). These results suggest that obsessions in particular might have an underlying glutamatergic pathology related to mGluR5. The research indicates that the development of metabotropic glutamate agents would be useful as a new treatment for OCD.