154 resultados para DOBUTAMINE


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although a new protocol of dobutamine stress echocardiography with the early injection of atropine (EA-DSE) has been demonstrated to be useful in reducing adverse effects and increasing the number of effective tests and to have similar accuracy for detecting coronary artery disease (CAD) compared with conventional protocols, no data exist regarding its ability to predict long-term events. The aim of this study was to determine the prognostic value of EA-DSE and the effects of the long-term use of beta blockers on it. A retrospective evaluation of 844 patients who underwent EA-DSE for known or suspected CAD was performed; 309 (37%) were receiving beta blockers. During a median follow-up period of 24 months, 102 events (12%) occurred. On univariate analysis, predictors of events were the ejection fraction (p <0.001), male gender (p <0.001), previous myocardial infarction (p <0.001), angiotensin-converting enzyme inhibitor therapy (p = 0.021), calcium channel blocker therapy (p = 0.034), and abnormal results on EA-DSE (p <0.001). On multivariate analysis, the independent predictors of events were male gender (relative risk [RR] 1.78, 95% confidence interval [CI] 1.13 to 2.81, p = 0.013) and abnormal results on EA-DSE (RR 4.45, 95% CI 2.84 to 7.01, p <0.0001). Normal results on EA-DSE with P blockers were associated with a nonsignificant higher incidence of events than normal results on EA-DSE without beta blockers (RR 1.29, 95% CI 0.58 to 2.87, p = 0.54). Abnormal results on EA-DSE with beta blockers had an RR of 4.97 (95% CI 2.79 to 8.87, p <0.001) compared with normal results, while abnormal results on EA-DSE without beta blockers had an RR of 5.96 (95% CI 3.41 to 10.44, p <0.001) for events, with no difference between groups (p = 0.36). In conclusion, the detection of fixed or inducible wall motion abnormalities during EA-DSE was an independent predictor of long-term events in patients with known or suspected CAD. The prognostic value of EA-DSE was not affected by the long-term use of beta blockers. (C) 2008 Elsevier Inc. All rights reserved. (Am J Cardiol 2008;102:1291-1295)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Dobutamine is the agent of choice for increasing cardiac output during myocardial depression in humans with septic shock. Studies have shown that beta-adrenoceptor agonists influence nitric oxide generation, probably by modulating cyclic adenosine monophosphate. We investigated the effects of dobutamine on the systemic and luminal gut release of nitric oxide during endotoxic shock in rabbits. Materials/Methods: Twenty anesthetized and ventilated New Zealand rabbits received placebo or intravenous lipopolysaccharide with or without dobutamine (5 mu g/kg/min). Ultrasonic flow probes placed around the superior mesenteric artery and the abdominal aorta continously estimated the flow. A segment from the ileum was isolated and perfused, and scrum nitrate/nitrite levels were measured in the perfusate solution and the serum every hour. Results: The mean arterial pressure decreased with statistical significance in the lipopolysaccharide group but not in the lipopolysaccharide/dobutamine group. The abdominal aortic flow decreased statistically significantly after lipopolysaccharide administration in both groups but recovered to base-line in the lipopolysaccharide/dobutamine group. The flow in the superior mesenteric artery was statistically significantly higher in the lipopolysaccharide/dobutamine group than in the lipopolysaccharide group at 2 hours. The serum nitrate/nitrite levels were higher in the lipopolysaccharide group and lower in the lipopolysaccharide/dobutamine group than those in the control group. The gut luminal perfusate serum nitrate/nitric level was higher in the lipopolysaccharide group than in the lipopolysaccharide/dobutamine group. Conclusions: Dobutamine can decrease total and intestinal nitric oxide production in vivo. Those effects seem to be inversely proportional to the changes in blood flow.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

(ECHOCARDIOGRAPHY, Volume 26, September 2009).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Left atrial volume indexed (LAVI) has been reported as a predictor of cardiovascular events. We sought to determine the prognostic value of LAVI for predicting the outcome of patients who underwent dobutamine stress echocardiography (DSE) for known or suspected coronary artery disease (CAD). Methods From January 2000 to July 2005, we studied 981 patients who underwent DSE and off-line measurements of LAVI. The value of DSE over clinical and LAVI data was examined using a stepwise log-rank test. Results During a median follow-up of 24 months, 56 (6%) events occurred. By univariate analysis, predictors of events were male sex, diabetes mellitus, previous myocardial infarction, left ventricular ejection fraction (LVEF), left atrial diameter indexed, LAVI, and abnormal DSE. By multivariate analysis, independent predictors were LVEF (relative risk [RR] = 0.98, 95% CI 0.95-1.00), LAVI (RR = 1.04, 95% CI 1.02-1.05), and abnormal DSE (RR = 2.70, 95% CI 1.28-5.69). In an incremental multivariate model, LAVI was additional to clinical data for predicting events (chi(2) 36.8, P < .001). The addition of DSE to clinical and LAVI yielded incremental information (chi(2) 55.3, P < .001). The 3-year event-free survival in patients with normal DSE and LAVI <= 33 mL/m(2) was 96%; with abnormal DSE and LAVI <= 33 mL/m(2), 91%; with normal DSE and LAVI >34 mL/m(2), 83%; and with abnormal DSE and LAVI >34 mL/m(2) 51%. Conclusion Left atrial volume indexed provides independent prognostic information in patients who underwent DSE for known or suspected CAD. Among patients with normal DSE, those with larger LAVI had worse outcome, and among patients with abnormal DSE, LAVI was still predictive. (Am Heart J 2008; 156:1110-6.)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction. Orthotopic heart transplantation renders the recipient denervated. This remodeling of the intrinsic cardiac nervous system should be taken in account during functional evaluation for allograft coronary artery disease. Dobutamine stress echocardiography (DSE) has been used to detect patients at greater risk. The aim of this study was to determine whether patients with various autonomic response levels, and supposed reinnervation patterns, show the same response to DSE. Methods. We studied 20 patients who had survived more than 5 years after orthotopic heart transplantation. All patients underwent a Holter evaluation. We considered patients with low variability to be those with less than a 40-bpm variation from the lowest to highest heart rate, so-called ""noninnenervated"" (group NI). Patients who had 40-bpm or more variation were considered to show high variability and called ""reinnervated"" (group RI). After that, all patients performed an ergometric test and DSE. Results. Groups were defined as NI (n = 9) and RI (n = 11). Ergometric tests confirmed this response with NI patients showing less variability when compared to RI patients (P = .0401). During DSE, patients showed similar median heart rate responses according to the dobutamine dose. Spearmen correlation showed r = 1.0 (P = .016). Conclusions: DES was effective to reach higher heart rates, probably related to catecholamine infusion. These findings may justify a better response when evaluating cardiac allograft vasculopathy in heart transplant patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To increase dobutamine stress echocardiography feasibility in patients with uncontrolled hypertension, we studied 729 consecutive patients referred for ischemia assessment. Methods: Patients with blood pressure ( BP) levels above 160/ 110 mm Hg were randomized to sublingual placebo or captopril ( 25 mg), and dobutamine stress echocardiography undertaken if BP decreased below 160/ 110 mm Hg after 15 minutes. Results: Of 149 patients ( 20%) with high BP levels, 104 ( 63 +/- 11 years, 51 male) were randomized. Baseline BP levels were similar for captopril ( 178 +/- 15/ 103 +/- 15 mm Hg) and placebo ( 181 +/- 17/ 103 +/- 15 mm Hg) groups. After intervention, 15 patients from captopril and 17 from placebo group had decreased BP ( 11% and 12% for systolic and 13% and 13% for diastolic BP, respectively). Five patients from placebo group ( P =.007) had to prematurely terminate the test because of hypertension ( BP > 220/ 120 mm Hg). Feasibility was similar for captopril and placebo groups ( 35% vs 25%, respectively, P = not significant). Conclusion: Although both captopril and placebo are effective in increasing dobutamine stress echocardiography feasibility in patients with uncontrolled BP, test interruption because of hypertension is less likely to occur after captopril administration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The subjective interpretation of dobutamine echocardiography (DBE) makes the accuracy of this technique dependent on the experience of the observer, and also poses problems of concordance between observers. Myocardial tissue Doppler velocity (MDV) may offer a quantitative technique for identification of coronary artery disease, but it is unclear whether this parameter could improve the results of less expert readers and in segments with low interobserver concordance. The aim of this study was to find whether MDV improved the accuracy of wall motion scoring in novice readers, experienced echocardiographers, and experts in stress echocardiography, and to identify the optimal means of integrating these tissue Doppler data in 77 patients who underwent DBE and angiography. New or worsening abnormalities were identified as ischemia and abnormalities seen at rest as scarring. Segmental MDV was measured independently and previously derived cutoffs were applied to categorize segments as normal or ab normal. Five strategies were used to combine MDV and wall motion score, and the results of each reader using each strategy were compared with quantitative coronary angiography. The accuracy of wall motion scoring by novice (68 +/- 3%) and experienced echocardiographers (71 +/- 3%) was less than experts in stress echocardiography (88 +/- 3%, p < 0.001). Various strategies for integration with MDV significantly improved the accuracy of wall motion scoring by novices from 75 +/- 2% to 77 +/- 5% (p < 0.01). Among the experienced group, accuracy improved from 74 +/- 2% to 77 +/- 5% (p < 0.05), but in the experts, no improvement was seen from their baseline accuracy. Integration with MDV also improved discordance related to the basal segments. Thus, use of MDV in all segments or MDV in all segments with wall motion scoring in the apex offers an improvement in sensitivity and accuracy with minimal compromise in specificity. (C) 2001 by Excerpta Medica, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Echocardiographic analysis of regional left ventricular function is based upon the assessment of radial motion. Long-axis motion is an important contributor to overall function. but has been difficult to evaluate clinically until the recent development of tissue Doppler techniques. We sought to compare the standard visual assessment of radial motion with quantitative tissue Doppler measurement of peak systolic velocity. timing and strain rate (SRI) in 104 patients with known or suspected coronary artery disease undergoing dobutamine stress echocardiography (DbE). A standard DbE protocol was used with colour tissue Doppler images acquired in digital cine-loop format. peak systolic velocity (PSV), time to peak velocity (TPV) and SRI were assessed off-line by an independent operator. Wall motion was assessed by an experienced reader. Mean PSV, TPV and SRI values were compared with wall motion and the presence of coronary artery disease by angiography. A further analysis included assessing the extent of jeopardized myocardium by comparing average values of PSV, TPV and SRI against the previously validated angiographic score. Segments identified as having normal and abnormal radial wall motion showed significant differences in mean PSV (7.9 +/- 3.8 and 5.9 +/- 3.3 cm/s respectively; P < 0.001), TPV (84 40 and 95 +/- 48 ms respectively; P = 0.005) and SRI (- 1.45 +/- 0.5 and - 1.1 +/- 0.9 s(-1) respectively; P < 0.001). The presence of a stenosed subtending coronary artery was also associated with significant differences from normally perfused segments for mean PSV (8.1 3.4 compared with 5.7 +/- 3.7 cm/s; P < 0.001), TPV (78 50 compared with 92 +/- 45 ms; P < 0.001) and SRI (- 1.35 0.5 compared with - 1.20 +/- 0.4 s(-1); P = 0.05). PSV, TPV and SRI also varied significantly according to the extent of jeopardized myocardium within a vascular territory. These results suggest that peak systolic velocity, timing of contraction and SRI reflect the underlying physiological characteristics of the regional myocardium during DbE, and may potentially allow objective analysis of wall motion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES We sought to find out whether dobutamine echocardiography (DbE) could provide independent prediction of total and cardiac mortality, incremental to clinical and angiographic variables. BACKGROUND Existing outcome studies with DbE have examined composite end points, rather than death, over a relatively short follow-up. METHODS Clinical and stress data were collected in 3,156 patients (age 63 +/- 12 years, 1,801 men) undergoing DbE. Significant stenoses (>50% diameter) were identified in 70% of 1,073 patients undergoing coronary angiography. Total and cardiac mortality were identified over nine years of follow-up (mean 3.8 +/- 1.9). Cox models were used to analyze the effect of ischemia and other variables, independent of other determinants of mortality. RESULTS The dobutamine echocardiogram was abnormal in 1,575 patients (50%). Death occurred in 716 patients (23%), 259 of whom (8%) were thought to have died from cardiac causes. Patients with normal DbE had a total mortality of 8% per year and a cardiac mortality of 1% per year over the first four years of follow-up. Ischemia and the extent of abnormal wall motion were independent predictors of cardiac death, together with age and heart failure. In sequential Cox models, the predictive power of clinical data alone (model chi-square 115) was strengthened by adding the resting left ventricular function (model chi-square 138) and the results of DbE (model chi-square 181). In the subgroup undergoing coronary angiography, the power of the model was increased to a minor degree by the addition of coronary anatomy data. CONCLUSIONS Dobutamine echocardiography is an independent predictor of death, incremental to other data. While a normal dobutamine echocardiogram predicts low risk of cardiac death ton the order of 1% per year), this risk increases with the extent of abnormal wall motion at rest and stress, (J Am Coil Cardiol 2001;37:754-60) (C) 2001 by the American College of Cardiology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES The goal of this study was to determine whether wall stress at rest and during stress could explain the influence of left ventricular (LV) morphology on the accuracy of dobutamine stress echocardiography (DSE). BACKGROUND The sensitivity of DSE appears to be reduced in patients with concentric remodeling, but the cause of this finding is unclear. METHODS We studied 161 patients without resting wall motion abnormalities who underwent DSE and coronary angiography. Patients were classified into four groups according to relative wan thickness (normal

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Diastolic dysfunction induced by ischemia may alter transmitral blood flow, but this reflects global ventricular function, and pseudonormalization may occur with increased preload. Tissue Doppler may assess regional diastolic function and is relatively load-independent, but limited data exist regarding its application to stress testing. We sought to examine the stress response of regional diastolic parameters to dobutomine echocardiography (DbE). Methods Sixty-three patients underwent study with DbE: 20 with low probability of coronary artery disease (CAD) and 43 with CAD who underwent angiography. A standard DbE protocol was used, and segments were categorized as ischemic, scar, or normal. Color tissue Doppler was acquired at baseline and peak stress, and waveforms in the basal and mid segments were used to measure early filling (Em), late filling (Am), and E deceleration time. Significant CAD was defined by stenoses >50% vessel diameter. Results Diastolic parameters had limited feasibility because of merging of Em and Am waves at high heart rates and limited reproducibility. Nonetheless, compared with normal segments, segments subtended with significant stenoses showed a lower Em velocity at rest (6.2 +/- 2.6 cm/s vs 4.8 +/- 2.2 cm/s, P < .0001) and peak (7.5 +/- 4.2 cm/s vs 5.1 +/- 3.6 cm/s, P < .0001), Abnormal segments also showed a shorter E deceleration time (51 +/- 27 ms vs 41 +/- 27 ms, P = .0001) at base and peak. No changes were documented in Am. The same pattern was seen with segments identified as ischemic with wall motion score. However, in the absence of ischemia, segments of patients with left ventricular hypertrophy showed a lower Em velocity, with blunted Em responses to stress. Conclusion Regional diastolic function is sensitive to ischemia. However, a number of practical limitations limit the applicability of diastolic parameters for the quantification of stress echocardiography.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Quantification of stress echocardiography may overcome the training requirements and subjective nature of visual wall motion score (WMS) assessment, but quantitative approaches may be difficult to apply and require significant time for image processing. The integral of long-axis myocardial velocity is displacement, which may be represented as a color map over the left ventricular myocardium. This study was designed to explore the feasibility and accuracy of measuring long-axis myocardial displacement, derived from tissue Doppler, for the detection of coronary artery disease (CAD) during dobutamine stress echocardiography (DBE). One hundred thirty patients underwent standard DBE, including 30 patients at low risk of CAD, 30 patients with normal coronary angiography (both groups studied to define normal ranges of displacement), and 70 patients who underwent coronary angiography in whom the accuracy of normal ranges was tested. Regional myocardial displacement was obtained by analysis of color tissue Doppler apical images acquired at peak stress. Displacement was compared with WMS, and with the presence of CAD by angiography. The analysis time was 3.2 +/- 1.5 minutes per patient. Segmental displacement was correlated with wall motion (normal 7.4 +/- 3.2 mm, ischemia 5.8 +/- 4.2 mm, viability 4.6 +/- 3.0 mm, scar 4.5 +/- 3.5 mm, p <0.001). Reversal of normal base-apex displacement was an insensitive (19%) but specific (90%) marker of CAD. The sum of displacements within each vascular territory had a sensitivity and specificity of 89% and 79%, respectively, for prediction of significant CAD, compared with 86% and 78%, respectively, for WMS (p = NS). The displacements in the basal segments had a sensitivity and specificity of 83% and 78%, respectively (p = NS). Regional myocardial displacement during DBE is feasible and offers a fast and accurate method for the diagnosis of CAD. (C),2002 by Excerpta Medica, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims To determine the degree of inter-institutional agreement in the assessment of dobutamine stress echocardiograms using modern stress echo cardiographic technology in combination with standardized data acquisition and assessment criteria. Method and Results Among six experienced institutions, 150 dobutamine stress echocardiograms (dobutamine up to 40 mug.kg(-1) min(-1) and atropine up to I mg) were performed on patients with suspected coronary artery disease using fundamental and harmonic imaging following a consistent digital acquisition protocol. Each dobutamine stress echocardiogram was assessed at every institution regarding endocardial visibility and left ventricular wall motion without knowledge of any other data using standardized reading criteria. No patients were excluded due to poor image quality or inadequate stress level. Coronary angiography was performed within 4 weeks. Coronary angiography demonstrated significant coronary artery disease (less than or equal to50% diameter stenosis) in 87 patients. Using harmonic imaging an average of 5.2+/-0.9 institutions agreed on dobutamine stress echocardiogram results as being normal or abnormal (mean kappa 0.55; 95% CI 0.50-0.60). Agreement was higher in patients with no (equal assessment of dobutamine stress echocardiogram results by 5.5 +/- 0.8 institutions) or three-vessel coronary artery disease (5.4 +/- 0.8 institutions) and lower in one- or two- vessel disease (5.0 +/- 0.9 and 5.2 +/- 1.0 institutions, respectively-, P=0.041). Disagreement on test results was greater in only minor wall motion abnormalities. Agreement on dobutamine stress echocardiogram results was lower using fundamental imaging (mean kappa 0.49; 95% CI 0.44-0.54; P

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The influence of complex plaque morphology on the extent of demand-induced ischemia in unselected patients is not well defined. We sought to investigate the functional significance of lesion morphology in patients who underwent coronary angiography and dobutamine stress echocardiography (DSE).,Angiography and DSE were performed within a 6-month period (mean 1 +/- 1 month) in 196 patients. Angiographic assessments involved quantification of stenosis severity, assessment of the extent of jeopardized myocardium, and categorization of plaque morphology according to the Ambrose classification. DSE was interpreted by separate investigators with respect to wall motion score index (WMSI) and number of coronary territories involved. A general linear model was constructed to assess,the independent contribution of patient characteristics and angiographic and DSE results with respect to extent of ischemic myocardium. Complex lesion morphology was seen in 62 patients (32%). Patients with complex lesions were more likely to have had prior myocardial infarction (p < 0.001) and be current smokers (p = 0.03). During angiography, they exhibited a trend toward a greater number of diseased vessels, had a greater coronary jeopardy score (p < 0.001) and more frequent collateral flow (p = 0.03). During echocardiography, patients had a higher stress WMSI (p < 0.001) and were more likely to show ischemia in all 3 arterial territories (p < 0.01). On multivariate regression, the coronary artery jeopardy score and the presence of complex plaque morphology were independent predictors of the extent of ischemic myocardium (R 2 = 34%, p < 0.001). Thus, patients with complex plaque morphology are older, more likely to smoke, and more likely to have had prior myocardial. infarction. They exhibit more extensive disease with higher coronary jeopardy scores and a higher resting and peak stress WMSI. Despite these differences, complex plaque morphology remains an independent predictor of the extent of ischemia during stress. (C) 2003 by Excerpta Medica, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES We sought to use quantitative markers of the regional left ventricular (LV) response to stress to infer whether diabetic cardiomyopathy is associated with ischemia. BACKGROUND Diabetic cardiomyopathy has been identified in clinical and experimental studies, but its cause remains unclear. METHODS We studied 41 diabetic patients with normal resting LV function and a normal dobutamine echo and 41 control subjects with a low probability of coronary disease. Peak myocardial systolic velocity (Sm) and early diastolic velocity (Em) in each segment were averaged, and mean Sm and Em were compared between diabetic patients and controls and among different stages of dobutamine stress. RESULTS Both Sm and Em progressively increased from rest to peak dobutamine stress. In the diabetic group, Sm was significantly lower than in control subjects at baseline (4.2 +/- 0.9 cm/s vs. 4.7 +/- 0.9 cm/s, p = 0.012). However, Sin at a low dose (6.0 +/- 1.3), before peak (8.4 +/- 1.8), and at peak stress (8.9 +/- 1.8) in diabetic patients was not significantly different from that of controls (6.3 +/- 1.4, 8.9 +/- 1.6, and 9.6 +/- 2.1 cm/s, respectively). The Em (cm/s) in the diabetic group (rest: 4.2 +/- 1.2; low dose: 5.0 +/- 1.4; pre-peak: 5.3 +/- 1.1; peak: 5.9 +/- 1.5) was significantly lower than that of controls (rest: 5.8 +/- 1.5; low dose: 6.6 +/- 1.5; pre-peak: 6.9 +/- 1.3; peak: 7.3 +/- 1.7; all p < 0.001). However, the absolute and relative increases in Sm or Em from rest to peak stress were similar in diabetic and control groups. CONCLUSIONS Subtle LV dysfunction is present in diabetic patients without overt cardiac disease. The normal response to stress suggests that ischemia due to small-vessel disease may not be important in early diabetic heart muscle disease. (C) 2003 by the American College of Cardiology Foundation.