980 resultados para DELIVERY RATE


Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To compare the cumulative live birth rates obtained after cryopreservation of either pronucleate (PN) zygotes or early-cleavage (EC) embryos. DESIGN: Prospective randomized study. SETTING: University hospital. PATIENT(S): Three hundred eighty-two patients, involved in an IVF/ICSI program from January 1993 to December 1995, who had their supernumerary embryos cryopreserved either at the PN (group I) or EC (group II) stage. For 89 patients, cryopreservation of EC embryos was canceled because of poor embryo development (group III). Frozen-thawed embryo transfers performed up to December 1998 were considered. MAIN OUTCOME MEASURE(S): Age, oocytes, zygotes, cryopreserved and transferred embryos, damage after thawing, cumulative embryo scores, implantation, and cumulative live birth rates. RESULT(S): The clinical pregnancy and live birth rates were similar in all groups after fresh embryo transfers. Significantly higher implantation (10.5% vs. 5.9%) and pregnancy rates (19.5% vs. 10.9%; P< or = .02 per transfer after cryopreserved embryo transfers were obtained in group I versus group II, leading to higher cumulative pregnancy (55.5% vs. 38.6%; P < or = .002 and live birth rates (46.9% vs. 27.7%; P< or = .0001.Conclusion(s): The transfer of a maximum of three unselected embryos and freezing of all supernumerary PN zygotes can be safely done with significantly higher cumulative pregnancy chances than cryopreserving at a later EC stage.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To determine whether infusion line compliance contributes to irregular drug delivery during vertical displacement of syringe pumps. DESIGN: Five different commercially available infusion lines were studied at infusion rates of 0.5, 1.0, and 1.5 ml/h. Zero drug delivery time was measured after acute line loop formation (70 cm) using an electronic balance. Compliance of each infusion line was calculated using a pressure transducer and measurement of the occlusion release bolus at 300 mmHg occlusion pressure. Finally, the influence of infusion line compliance on drug delivery during acute lowering of the syringe pump was studied using low- and high-compliance infusion lines. RESULTS: Acute line loop formation resulted in zero drug delivery time from 5.1 +/- 1.5 to 44.0 +/- 6.8 s at flow rates of 0.5 ml/h. Increased flow rates significantly reduced loop-induced flow variability. A close correlation was found between zero drug delivery time and calculated infusion line compliance at 0.5 ml/h (linear regression R2 = 0.79). Lowering of the syringe pump 50 cm prolonged zero drug delivery time from 295.8 +/- 20.7 s with the low-compliance tube to 463.3 +/- 24.0 s with the high-compliance infusion line. CONCLUSIONS: Infusion line compliance contributes to irregular drug delivery associated with vertical displacement of syringe pumps. Siphoning of the infusion line during patient care should be avoided, and flow rates of 1 ml/h or higher are recommended. Low-compliance infusion lines are indicated whenever highly short-acting vasoactive drugs at low delivery rates are administered.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

National and international registries are essential tools for establishing new standards and comparing success rates, but they do not take into account the total pregnancy/delivery rate per oocyte recovery. In Switzerland and Germany, because of legal constraints, a maximum of three two-pronuclear zygotes are allocated for transfer whereas all the supernumerary pronuclear zygotes are immediately cryopreserved, preventing selection of the transferred embryos. We report on a 10 years' experience (1993-2002) of our centre which performs transfers of unselected embryos and cryopreservation at the two-pronuclear zygote stage. As approximately 30% of all deliveries are from cryo cycles, it is essential to take into account the contribution of the cryo transfers, and we propose therefore to evaluate, as a measure of IVF performance, the cumulated delivery rate per oocyte pick-up. This delivery rate is broken down further into the cumulated singleton delivery rate (CUSIDERA) and the cumulated twin delivery rate (CUTWIDERA). The sum (S) of these two rates is a measure of efficacy while the ratio CUTWIDERA/S as a percentage is a measure of safety of IVF treatments. Using these new indexes, the average 10 year efficacy and safety of our IVF programme were 26 and 19%, respectively. Both CUSIDERA and CUTWIDERA can be calculated easily in any clinical situation and yield useful parameters for patient counselling and internal/external benchmarking purposes.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

We analyzed the effectiveness of linear short- and long-term variability time domain parameters, an index of sympatho-vagal balance (SDNN/RMSSD) and entropy in differentiating fetal heart rate patterns (fHRPs) on the fetal heart rate (fHR) series of 5, 3 and 2 min duration reconstructed from 46 fetal magnetocardiograms. Gestational age (GA) varied from 21 to 38 weeks. FHRPs were classified based on the fHR standard deviation. In sleep states, we observed that vagal influence increased with GA, and entropy significantly increased (decreased) with GA (SDNN/RMSSD), demonstrating that a prevalence of vagal activity with autonomous nervous system maturation may be associated with increased sleep state complexity. In active wakefulness, we observed a significant negative (positive) correlation of short-term (long-term) variability parameters with SDNN/RMSSD. ANOVA statistics demonstrated that long-term irregularity and standard deviation of normal-to-normal beat intervals (SDNN) best differentiated among fHRPs. Our results confirm that short-and long-term variability parameters are useful to differentiate between quiet and active states, and that entropy improves the characterization of sleep states. All measures differentiated fHRPs more effectively on very short HR series, as a result of the fMCG high temporal resolution and of the intrinsic timescales of the events that originate the different fHRPs.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

PURPOSE Management of ureteral stones remains controversial. To determine whether optimizing extracorporeal shock wave lithotripsy (ESWL) delivery rates improves treatment of solitary ureteral stones, we compared outcomes of two SW delivery rates in a prospective, randomized trial. MATERIALS AND METHODS From July 2010 to October 2012, 254 consecutive patients were randomized to undergo ESWL at SW delivery rates of either 60 pulses (n=130) or 90 pulses (n=124) per min. The primary endpoint was stone-free rate at 3-month follow-up. Secondary endpoints included stone disintegration, treatment time, complications, and the rate of secondary treatments. Descriptive statistics were used to compare endpoints between the two groups. Adjusted odds ratios and 95% confidence intervals were calculated to assess predictors of success. RESULTS The stone-free rate at 3 months was significantly higher in patients who underwent ESWL at a SW delivery rate of 90 pulses per min than in those receiving 60 pulses (91% vs. 80%, p=0.01). Patients with proximal and mid-ureter stones, but not those with distal ureter stones, accounted for the observed difference (100% vs. 83%; p=0.005; 96% vs. 73%, p=0.03; and 81% vs. 80%, p=0.9, respectively). Treatment time, complications, and the rate of secondary treatments were comparable between the two groups. In multivariable analysis, SW delivery rate of 90 pulses per min, proximal stone location, stone density, stone size and the absence of an indwelling JJ stent were independent predictors of success. CONCLUSIONS Optimization of ESWL delivery rates can achieve excellent results for ureteral stones.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Cardiac arrhythmias are a frequent cause of death and morbidity. Conventional antiarrhythmia therapy involving oral or intravenous medication is often ineffective and complicated by drug-associated side effects. Previous studies from our laboratory have demonstrated the advantages of cardiac drug-polymer implants for enhanced efficacy for cardiac arrhythmia therapy compared with conventional administration. However, these studies were based on systems that deliver drugs at a fixed release rate. Modulation of the drug delivery rate has the advantage of regulating the amount of the drug delivered depending upon the disease state of the patient. We hypothesized that iontophoresis could be used to modulate cardiac drug delivery. In this study, we report our investigations of a cardiac drug implant in dogs that is capable of iontophoretic modulation of the administration of the antiarrhythmic agent sotalol. We used a heterogeneous cation-exchange membrane (HCM) as an electrically sensitive and highly efficient rate-limiting barrier on the cardiac-contacting surface of the implant. Thus, electric current is passed only through the HCM and not the myocardium. The iontophoretic cardiac implant demonstrated in vitro drug release rates that were responsive to current modulation. In vivo results in dogs have confirmed that iontophoresis resulted in regional coronary enhancement of sotalol levels with current-responsive increases in drug concentrations. We also observed acute current-dependent changes in ventricular effective refractory periods reflecting sotalol-induced refractoriness due to regional drug administration. In 30-day dog experiments, iontophoretic cardiac implants demonstrated robust sustained function and reproducible modulation of drug delivery kinetics.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: Although still uncommon, pregnancy frequency in women on maintenance hemodialysis therapy has increased in the past 20 years. Most published reports suggest that intensified hemodialysis regimens result in better pregnancy outcomes. The small number of patients investigated in all reported series is the main limitation of the available studies. Study Design: Retrospective case series. Setting & Participants: Data for all pregnancies that occurred in 1988-2008 in women undergoing maintenance hemodialysis (52 pregnancies) at the Sao Paulo University Medical School (Sao Paulo, Brazil). Outcomes & Measurements: We analyzed maternal and fetal outcomes of 52 pregnancies, as well as their relationship with various clinical, laboratory, and hemodialysis parameters, such as pre-eclampsia, pregnancy before or after dialysis therapy, hemodialysis dose, polyhydramnios, anemia, and predialysis serum urea level. In addition, logistic regression models for a composite adverse fetal outcome (perinatal death or extremely premature delivery) and linear regression models for birth weight were built. Results: 87% overall rate of successful delivery, with a mean gestational age of 32.7 +/- 3.1 weeks. Pre-eclampsia was associated with a poor prognosis compared with pregnancies without pre-eclampsia: a successful delivery rate of 60% versus 92.9% (P = 0.02), extremely premature delivery rate of 77.8% versus 3.3% (P = 0.001), lower gestational age (P = 0.001), and birth weight (P = 0.001). Patients with an adverse composite fetal outcome had a higher frequency of pre-eclampsia (P = 0.001), lower frequency of polyhydramnios (P = 0.03), lower third-trimester hematocrit (P = 0.03), and higher predialysis serum urea level (P = 0.03). The same results were seen for birth weight. Limitations: Retrospective data analysis. The absence of creatinine clearance measurements did not allow evaluation of the impact of residual renal function on fetal outcome. Conclusions: Outcomes of pregnancy in women undergoing hemodialysis often are good. Preeclampsia, third-trimester hematocrit, polyhydramnios, and predialysis serum urea level are important variables associated with fetal outcome and birth weight. Am J Kidney Dis 56:77-85. (C) 2010 by the National Kidney Foundation, Inc.Inc

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: Comparative genomic hybridization (CGH) is a valuable alternative to fluorescence in situ hybridization (FISH) for preimplantation genetic screening (PGS) because it allows full karyotype analysis. However, this approach requires the cryopreservation of biopsied embryos until results are available. The aim of this study is to reduce the hybridization period of CGH, in order to make this short-CGH technique suitable for PGS of Day-3 embryos, avoiding the cryopreservation step. METHODS: Thirty-two fibroblasts from six aneuploid cell lines (Coriell) and 48 blastomeres from 10 Day-4 embryos, discarded after PGS by FISH with 9 probes (9-chr-FISH), were analysed by short-CGH. A reanalysis by the standard 72 h-CGH and FISH using telomeric probes was performed when no concordant results between short-CGH and FISH diagnosis were observed. The short-CGH was subsequently applied in a clinical case of advanced maternal age. RESULTS: In 100% of the fibroblasts analysed, the characteristic aneuploidies of each cell line were detected by short-CGH. The results of the 48 blastomeres screened by short-CGH were supported by both 72 h-CGH results and FISH reanalysis. The chromosomes most frequently involved in aneuploidy were 22 and 16, but aneuploidies for the other chromosomes, excepting 1, 10 and 13, were also detected. Forty-one of the 94 aneuploid events observed (43.6%) corresponded to chromosomes which are not analysed by 9-chr-FISH. CONCLUSIONS: We have performed a preliminary validation of the short-CGH technique, including one clinical case, suggesting this approach may be applied to Day-3 aneuploidy analysis, thereby avoiding embryo cryopreservation and perhaps helping to improve implantation rate after PGS.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this study was to investigate whether distinct cooling of low fluence erbium, chromium:yttrium-scandium-gallium-garnet (Er,Cr:YSGG) laser irradiation would influence adhesion. Main factors tested were: substrates (two), irradiation conditions (three), and adhesives (three). A 750 mu m diameter tip was used, for 50 s, 1 mm from the surface, with a 0.25 W power output, 20 Hz, energy density of 2.8 J/cm(2) with energy per pulse of 12.5 mJ. When applied, water delivery rate was 11 ml/min. The analysis of variance (ANOVA) showed that laser conditioning significantly decreased the bond strength of all adhesive systems applied on enamel. On dentin, laser conditioning significantly reduced bond strength of etch-and-rinse and one-step self-etch systems; however, laser irradiation under water cooling did not alter bonding of two-step self-etching. It may be concluded that the irradiation with Er,Cr:YSGG laser at 2.8 J/cm(2) with water coolant was responsible for a better adhesion to dentin, while enamel irradiation reduced bond strength, irrespective of cooling conditions.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Because the diagnostic tools for predicting whether an early cleavage stage embryo can lead to a viable pregnancy are still elusive, transfer of more than one embryo remains quite common. However, the only way to reduce multiple pregnancies, considered as the main adverse effect of assisted reproductive technology, is to transfer a single embryo. In countries such as Switzerland and Germany, the law allows cryopreservation only at the 2-pronuclear stage. This restricts considerably the possibility of selecting the embryos to be transferred. Therefore, a good cryopreservation program at the 2-pronuclear stage is an essential tool to optimize the efficiency of in vitro fertilization (IVF). We therefore recommend the Cumulated Singleton Delivery Rate (CUSIDERA) as a measure of standard IVF efficiency. This rate averages approximately 23.5% when calculated over the last 10 years in our unit and reaches a value above 35% for patients with more than 10 zygotes. Elective single-embryo transfers and the decrease of iatrogenic multiple pregnancies in IVF remain dependent on better prognostic tools for the appropriate selection of patients, gametes, and zygotes.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE: In order to improve the quality of our Emergency Medical Services (EMS), to raise bystander cardiopulmonary resuscitation rates and thereby meet what is becoming a universal standard in terms of quality of emergency services, we decided to implement systematic dispatcher-assisted or telephone-CPR (T-CPR) in our medical dispatch center, a non-Advanced Medical Priority Dispatch System. The aim of this article is to describe the implementation process, costs and results following the introduction of this new "quality" procedure. METHODS: This was a prospective study. Over an 8-week period, our EMS dispatchers were given new procedures to provide T-CPR. We then collected data on all non-traumatic cardiac arrests within our state (Vaud, Switzerland) for the following 12months. For each event, the dispatchers had to record in writing the reason they either ruled out cardiac arrest (CA) or did not propose T-CPR in the event they did suspect CA. All emergency call recordings were reviewed by the medical director of the EMS. The analysis of the recordings and the dispatchers' written explanations were then compared. RESULTS: During the 12-month study period, a total of 497 patients (both adults and children) were identified as having a non-traumatic cardiac arrest. Out of this total, 203 cases were excluded and 294 cases were eligible for T-CPR. Out of these eligible cases, dispatchers proposed T-CPR on 202 occasions (or 69% of eligible cases). They also erroneously proposed T-CPR on 17 occasions when a CA was wrongly identified (false positive). This represents 7.8% of all T-CPR. No costs were incurred to implement our study protocol and procedures. CONCLUSIONS: This study demonstrates it is possible, using a brief campaign of sensitization but without any specific training, to implement systematic dispatcher-assisted cardiopulmonary resuscitation in a non-Advanced Medical Priority Dispatch System such as our EMS that had no prior experience with systematic T-CPR. The results in terms of T-CPR delivery rate and false positive are similar to those found in previous studies. We found our results satisfying the given short time frame of this study. Our results demonstrate that it is possible to improve the quality of emergency services at moderate or even no additional costs and this should be of interest to all EMS that do not presently benefit from using T-CPR procedures. EMS that currently do not offer T-CPR should consider implementing this technique as soon as possible, and we expect our experience may provide answers to those planning to incorporate T-CPR in their daily practice.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE: To compare obstetric outcomes of induced preterm twin births (under 32 weeks gestation) with those spontaneously conceived. METHODS: Prospective study of twin pregnancies (25 induced and 157 spontaneously conceived) developed over a period of 16 years in a tertiary obstetric center. Demographic factors, obstetric complications, gestational age at delivery, mode of delivery, birth weight and immediate newborn outcome were compared. RESULTS: The analysis of obstetrical complications concerning urinary or other infections, hypertensive disorders of pregnancy, gestational diabetes, fetal malformations, intrauterine fetal death, intrauterine growth restriction and intrauterine discordant growth reveal no significant statistical differences between the two groups. First trimester bleeding was higher in the induced group (24 versus 8.3%, p=0.029). The cesarean delivery rate was 52.2% in spontaneous gestations and 64% in induced gestations. Gestational age at delivery, birth weight, Apgar scores at first and fifth minutes, admissions to Neonatal Intensive Care Unit and puerperal complications show no statistically significant differences between the two groups. These results were independent of chorionicity and induction method. CONCLUSION: The mode of conception did not influence obstetric and neonatal outcomes. Although induced pregnancies have higher risk of first trimester bleeding, significant differences were not observed regarding other obstetric and puerperal complications and neonatal results.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

INTRODUCCION La hipotensión arterial por anestesia raquídea en embarazadas llevadas a cesárea es frecuente y deletérea para la madre y el feto, sin que a la fecha exista una herramienta clínicamente útil para predecirla. La variabilidad de la frecuencia cardiaca es una medida que estima la actividad del sistema nervioso autónomo y algunos estudio iniciales indican una posible utilidad como herramienta predictiva de hipotensión arterial en esta población. METODOLOGIA Se realizó un estudio observacional descriptivo para examinar el comportamiento de la variabilidad de la frecuencia cardiaca, medida como razón de Baja frecuencia/Alta frecuencia, con un punto de corte de 2.5 tomada con un reloj POLAR RS800CX, en una población de pacientes con embarazo a término llevadas a cesárea, en un hospital de tercer nivel en Bogotá- Colombia entre Febrero y Abril del 2015. RESULTADOS El estudio incluyó 82 pacientes. Se determinó que la razón Baja frecuencia/Alta frecuencia mayor a 2,5 era poco frecuente en nuestra población (15.85%), y su asociación no fue significativa. DISCUSION El presente estudio demostró que la asociación entre la presencia de hipotensión y un índice Baja frecuencia/Alta frecuencia con punto de corte de 2.5 no es significativo para nuestra población de mujeres con embarazo a término llevadas a cesárea con anestesia espinal. Según los resultados se sugieres un punto de corte de 1.6 como punto de partida para la realización de nuevos estudios que permitan validar este valor.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In a two-period economy with incomplete markets and possibility of default we consider the two classical ways to enforce the honor of financial commitments: by using utility penalties and by using collateral requirements that borrowers have to fulfill. Firstly, we prove that any equilibrium in an economy with collateral requirements is also equilibrium in a non-collateralized economy where each agent is penalized (rewarded) in his utility if his delivery rate is lower (greater) than the payment rate of the financial market. Secondly, we prove the converse: any equilibrium in an economy with utility penalties is also equilibrium in a collateralized economy. For this to be true the payoff function and initial endowments of the agents must be modified in a quite natural way. Finally, we prove that the equilibrium in the economy with collateral requirements attains the same welfare as in the new economy with utility penalties.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)