151 resultados para DBS


Relevância:

20.00% 20.00%

Publicador:

Resumo:

进行了十二烷基苯磺酸钠(DBS)对原生动物的种、种群和群落等三个不同生物学组织水平的毒性试验。结果表明:DBS对5种原生动物的急性毒性作用没有种的特异性(p>0.05)。半致死浓度12h-LC_(50)在7.0—10.47ppm之间;对美洲四膜虫种群的急性毒性作用,12h—LC_(50)为17.21ppm;对其呼吸率的影响,表明其效应浓度为12.84ppm(p<0.05);3—40ppm DBS,对微型生物群落的结构、功能有不同程度的影响。结构参数有原生动物种类组成和种类数;功能参数有原生动物群集过程、微

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A continuous-time 7th-order Butterworth Gm-C low pass filter (LPF) with on-chip automatic tuning circuit has been implemented for a direct conversion DBS tuner in a 0.35um SiGe BiCMOS technology. The filter's -3dB cutoff frequency f(0) can be tuned from 4MHz to 40MHz. A novel translinear transconductor (Gm) cell is used to implement the widely tunable and high linear filter. The filter has -0.5dB passband gain, 28nV/Hz(1/2) input referred noise, -2dBVrms passband IIP3, 24dBVrms stopband IIP3. The I/Q LPFs with the tuning circuit draw 16mA (with f(0)=20MHz) from 3.3 V supply, and occupy an area of 0.45 mm(2).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A continuous-time 7th-order Butterworth Gm-C low pass filter (LPF) with on-chip automatic tuning circuit has been implemented for a direct conversion DBS tuner in 0.35μm SiGe BiCMOS technology. The filter's -3 dB cutoff frequency f0 can be tuned from 4 to 40 MHz. A novel on-chip automatic tuning scheme has been successfully realized to tune and lock the filter's cutoff frequency. Measurement results show that the filter has -0.5 dB passband gain, +/- 5% bandwidth accuracy, 30 nV/Hz~(1/2) input referred noise, -3 dBVrms passband IIP3, and 27 dBVrms stopband IIP3. The I/Q LPFs with the tuning circuit draw 13 mA (with f_0 = 20 MHz) from 5 V supply, and occupy 0.5 mm~2.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Macrokinetic models, namly the modified Avrami, Ozawa and Zibicki models, were applied to study the non-isothermal melt crystallization process of PET/PEN/DBS blends by DSC measurement. The modified Avrami model was found to describe the experimental data fairly well. With the cooling rates in the range from 5 to 20 K/min, Ozawa model could be well used to describe the early stages of crystallization. However, Ozawa model did not fit the polymer blends during the late stages of crystallization, because it ignored the influence of secondary crystallization. The crystallization ability of the blends decreases with increasing the DBS content from analysis by using Ziabicki kinetic model, which is similar to the results based on calculation of the effective energy barrier of the blends.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents design and simulation of a miniature rectangular spiral planar inverted-F antenna (PIFA) at UHF RFID band (902.75 - 927.25 MHz) for integration in batteryless deep brain stimulation implants. Operation in the UHF band offers small antenna size and longer transmission range. The proposed antenna has the dimensions of 10 mm × 11.5 mm × 1.6 mm, resonance frequency of 920 MHz with a bandwidth of 18 MHz at return loss of -10 dB. A dielectric substrate of FR-4 of εr = 4.5 and δ = 0.018 with thickness of 1.5644 mm is used in this design. The resonance, radiation characteristics as well as the specific absorption rate distribution induced by the designed antenna within a four layer spherical head model is evaluated by using electromagnetic modeling software which employs the finite element method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents design and simulation of a circular meander dipole antenna at the industrial, scientific, and medical band of 915 MHz for energy scavenging in a passive head-mountable deep brain stimulation device. The interaction of the proposed antenna with a rat body is modeled and discussed. In the antenna, the radiating layer is meandered, and a FR-4 substrate is used to limit the radius and height of the antenna to 14 mm and 1.60 mm, respectively. The resonance frequency of the designed antenna is 915 MHz and the bandwidth of 15 MHz at a return loss of -10 dB in free space. To model the interaction of the antenna with a rat body, two aspects including functional and biological are considered. The functional aspect includes input impedance, resonance frequency, gain pattern, radiation efficiency of the antenna, and the biological aspect involves electric field distribution, and SAR value. A complete rat model is used in the finite difference time domain based EM simulation software XFdtd. The simulated results demonstrate that the specific absorption rate distributions occur within the skull in the rat model, and their values are higher than the standard regulated values for the antenna receiving power of 1W.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents an analysis of optimum rectifier circuits for wireless energy harvesting in deep brain stimulation (DBS) devices. Since DBS demands compact and low power consumption devices, small, high conversion efficient, and high output voltage rectifiers need to be developed. The investigation that is presented in this paper is analytical and simulated based. Analysis on a variety of circuit configurations brings more evidence to improve the performance of rectifiers. Analytical parameters influencing the output DC voltage and the efficiency of the rectifiers are described. The operating frequency of the 915 MHz industrial, scientific and medical (ISM) radio band is used in this study. The maximum conversion efficiency of the LC matched half wave rectifier, the Greinacher voltage doubler, the Delon doubler, and the 2-stage voltage multiplier is obtained as 56.34%, 74.45%, 71.48%, and 31.44%, respectively, at the 30 dBm input power level. The corresponding maximum output DC voltages are 6.27 V, 16.83 V, 13.36 V, and 9.20 V. Thus the Greinacher voltage doubler is deemed as the best configuration according to the conversion efficiency and the output voltage measurements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A circular planar inverted-F antenna (PIFA) is designed and simulated at the industrial, scientific, and medical (ISM) band of 915 MHz for energy harvesting in a head-mountable deep brain stimulation device. Moreover, a rectifier is designed, and also the interaction of the PIFA with a rat head model is investigated. In the proposed PIFA, the top radiating layer is meandered, and a substrate of FR-4 is used. The radius and the height of the antenna are 10 mm and 1.8 mm, respectively. The bottom conductive layer works as a ground plate, and a superstrate of polyethylene reduces the electromagnetic penetration into the rat head. The resonance frequency of the designed antenna is 915 MHz with a bandwidth of 18 MHz at the return loss of -10 dB in free space. The antenna parameters (e.g. reflection coefficient, gain, radiation efficiency), electric field distribution, and SAR value are evaluated within a seven-layer rat head model by using the finite difference time domain EM simulation software XFdtd. The interactions of the antenna and the rat head model are studied in both functional and biological aspects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

 Development of an optimum rectenna for radio frequency energy harvesting in miniature head-mountable deep brain stimulation (DBS) devices. The designed miniature rectenna can operate a DBS device without battery for murine preclinical research. The battery-less operation of the device eliminates battery related difficulties.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In many patients, optimal results after pallidal deep brain stimulation (DBS) for primary dystonia may appear over several months, possibly beyond 1 year after implant. In order to elucidate the factors predicting such protracted clinical effect, we retrospectively reviewed the clinical records of 44 patients with primary dystonia and bilateral pallidal DBS implants. Patients with fixed skeletal deformities, as well as those with a history of prior ablative procedures, were excluded. The Burke-Fahn-Marsden Dystonia Rating Scale (BFMDRS) scores at baseline, 1 and 3 years after DBS were used to evaluate clinical outcome. All subjects showed a significant improvement after DBS implants (mean BFMDRS improvement of 74.9% at 1 year and 82.6% at 3 years). Disease duration (DD, median 15 years, range 2-42) and age at surgery (AS, median 31 years, range 10-59) showed a significant negative correlation with DBS outcome at 1 and 3 years. A partition analysis, using DD and AS, clustered subjects into three groups: (1) younger subjects with shorter DD (n = 19, AS < 27, DD ? 17); (2) older subjects with shorter DD (n = 8, DD ? 17, AS ? 27); (3) older subjects with longer DD (n = 17, DD > 17, AS ? 27). Younger patients with short DD benefitted more and faster than older patients, who however continued to improve 10% on average 1 year after DBS implants. Our data suggest that subjects with short DD may expect to achieve a better general outcome than those with longer DD and that AS may influence the time necessary to achieve maximal clinical response.