6 resultados para DANAZOL


Relevância:

20.00% 20.00%

Publicador:

Resumo:

International audience

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The feasibility of different modern analytical techniques for the mass spectrometric detection of anabolic androgenic steroids (AAS) in human urine was examined in order to enhance the prevalent analytics and to find reasonable strategies for effective sports drug testing. A comparative study of the sensitivity and specificity between gas chromatography (GC) combined with low (LRMS) and high resolution mass spectrometry (HRMS) in screening of AAS was carried out with four metabolites of methandienone. Measurements were done in selected ion monitoring mode with HRMS using a mass resolution of 5000. With HRMS the detection limits were considerably lower than with LRMS, enabling detection of steroids at low 0.2-0.5 ng/ml levels. However, also with HRMS, the biological background hampered the detection of some steroids. The applicability of liquid-phase microextraction (LPME) was studied with metabolites of fluoxymesterone, 4-chlorodehydromethyltestosterone, stanozolol and danazol. Factors affecting the extraction process were studied and a novel LPME method with in-fiber silylation was developed and validated for GC/MS analysis of the danazol metabolite. The method allowed precise, selective and sensitive analysis of the metabolite and enabled simultaneous filtration, extraction, enrichment and derivatization of the analyte from urine without any other steps in sample preparation. Liquid chromatographic/tandem mass spectrometric (LC/MS/MS) methods utilizing electrospray ionization (ESI), atmospheric pressure chemical ionization (APCI) and atmospheric pressure photoionization (APPI) were developed and applied for detection of oxandrolone and metabolites of stanozolol and 4-chlorodehydromethyltestosterone in urine. All methods exhibited high sensitivity and specificity. ESI showed, however, the best applicability, and a LC/ESI-MS/MS method for routine screening of nine 17-alkyl-substituted AAS was thus developed enabling fast and precise measurement of all analytes with detection limits below 2 ng/ml. The potential of chemometrics to resolve complex GC/MS data was demonstrated with samples prepared for AAS screening. Acquired full scan spectral data (m/z 40-700) were processed by the OSCAR algorithm (Optimization by Stepwise Constraints of Alternating Regression). The deconvolution process was able to dig out from a GC/MS run more than the double number of components as compared with the number of visible chromatographic peaks. Severely overlapping components, as well as components hidden in the chromatographic background could be isolated successfully. All studied techniques proved to be useful analytical tools to improve detection of AAS in urine. Superiority of different procedures is, however, compound-dependent and different techniques complement each other.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Technological forecasting, defined as quantified probabilistic prediction of timings and degree of change in the technological parameters, capabilities desirability or needs at different times in the future, is applied to birth control technology (BCT) as a means of revealing the paths of most promising research through identifying the necessary points for breakthroughs. The present status of BCT in the areas of pills and the IUD, male contraceptives, immumological approaches, post-coital pills, abortion, sterilization, luteolytic agents, laser technologies, and control of the sex of the child, are each summarized and evaluated in turn. Fine mapping is done to identify the most potentially promising areas of BCT. These include efforts to make oral contraception easier, improvement of the design of the IUD, clinical evaluation of the male contraceptive danazol, the effecting of biochemical changes in the seminal fluid, and researching of immunological approaches and the effects of other new drugs such as prostaglandins. The areas that require immediate and large research inputs are oral contraception and the IUD. On the basis of population and technological forecasts, it is deduced that research efforts could most effectively aid countries like India through the immediate production of an oral contraceptive pill or IUD with long-lasting effects. Development of a pill for males or an immunization against pre gnancy would also have a significant impact. However, the major impediment to birth control programs to date is attitudes, which must be changed through education.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To evaluate serum concentrations of CA-125 and soluble CD-23 and to correlate them with clinical symptoms, localization and stage of pelvic endometriosis and histological classification of the disease. Methods: Blood samples were collected from 44 women with endometriosis and 58 without endometriosis, during the first three days (1st sample) and during the 7th, 8th and 9th day (2nd sample) of the menstrual cycle. Measurements of CA-125 and soluble CD-23 were performed by ELISA. Mann-Whitney U test was used for age, pain evaluations (visual analog scale) and biomarkers concentrations. Results: Serum levels Of CA-125 were higher in endometriosis patients when compared to the control group during both periods of the menstrual cycle evaluated in the study. This marker was also elevated in women with chronic pelvic pain, deep dyspareunia (2nd sample), dysmenorrhea (both samples) and painful defecation during the menstrual flow (2nd sample). CA-125 concentration was higher in advanced stages of the disease in both samples and also in women with ovarian endometrioma. Concerning CD-23, no statistically significant differences were observed between groups. Conclusion: The concentrations of CA-125 were higher in patients with endometriosis than in patients without the disease. No significantly differences were observed for soluble CD-23 levels between groups.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Biorelevante Medien sind entwickelt worden, um die Bedingungen im Magen-Darm-Trakt vor und nach der Mahlzeit zu imitieren. Mit FaSSIF und FeSSIF wurden Medien eingeführt, die nicht nur die pH- und Puffer-Kapazität des Dünndarms widerspiegeln, sondern auch Lipid und physiologische Tensid-Arten enthalten. Diese Medien (FaSSIF-V2 und FaSSlFmod6.5) wurden für Bioverfügbarkeitstudien in der Medikamentenentwicklung im Laufe der Jahre kontinuierlich weiterentwickelt. Dennoch sind die auf dem Markt verfügbaren Medien immer noch nicht in der Lage, die realen physiologischen Bedingungen zu simulieren. In der jetzigen Zusammensetzung sind nicht alle Kompetenten enthalten, welche natürlicher Weise im Duodenum vorkommen. Darüber hinaus wird nur eine 1:5 Verdünnung von FeSSIF zu FaSSIF angenommen, die individuelle Wasserzufuhr bei Medikamentengabe wird hierdurch jedoch nur eingeschränkt simuliert, obwohl diese von Patient zu Patient schwanken kann. rnZiel dieser Dissertation war die Verbesserung der Vorhersage der Auflösung und Absorption lipophiler Arzneistoffe durch Simulation der Bedingungen im zweiten Teil des Zwölffingerdarms mit neuen biorelevanten Medien, sowie unter Einwirkung zusätzlicher Detergention als Wirkstoffträger. rnUm den Effekt der Verdünnungsrate und Zeit im Dünndarm zu untersuchen, wurde die Entwicklung der Nanopartikel in der Magen-Darm-Flüssigkeit FaSSIFmod6.5 zu verschiedenen Zeitpunkten und Wassergehalten untersucht. Dafür wurden kinetische Studien an verschieden konzentrierten Modellmedien nach Verdünnungssprung untersucht. Das Modell entspricht der Vermischung der Gallenflüssigkeit mit dem Darminhalt bei variablem Volumen. Die Ergebnisse zeigen, dass Art und Größe der Nanopartikel stark von Verdünnung und Einirkungszeit abhängen. rnrnDie menschliche Darmflüssigkeit enthält Cholesterin, welches in allen früheren Modellmedien fehlt. Daher wurden biokompatible und physiologische Modellflüssigkeiten, FaSSIF-C, entwickelt. Der Cholesteringehalt von FaSSIF - 7C entspricht der Gallenflüssigkeit einer gesunden Frau, FaSSIF - 10C der einer gesunden männlichen Person und FaSSIF - 13C der in einigen Krankheitszuständen. Die intestinale Teilchen-Struktur-Untersuchung mit dynamische Lichtstreuung (DLS) und Neutronen-Kleinwinkelstreuung (SANS) ergab, dass die Korngröße von Vesikeln mit zunehmender Cholesterin-Konzentration abnahm. Zu hohe Cholesterin-Konzentration bewirkte zusätzlich sehr große Partikel, welche vermutlich aus Cholesterin-reichen “Disks“ bestehen. Die Löslichkeiten einiger BCS Klasse II Wirkstoffe (Fenofibrat, Griseofulvin, Carbamazepin, Danazol) in diesen neuen Medien zeigten, dass die Löslichkeit in unterschiedlicher Weise mit der Cholesteringehalt zusammen hing und dieser Effekt selektiv für die Droge war. rnDarüber hinaus wurde die Wirkung von einigen Tensiden auf die kolloidale Struktur und Löslichkeit von Fenofibrat in FaSSIFmod6.5 und FaSSIF -7C untersucht. Struktur und Löslichkeit waren Tensid- und Konzentrations-abhängig. Im Falle von FaSSIFmod6.5 zeigten die Ergebnisse eine dreifache Verzweigung der Lösungswege. Im Bereich mittlerer Tensidkonzentration wurde eine Löslichkeitslücke der Droge zwischen der Zerstörung der Galle-Liposomen und der Bildung von Tensid-reichen Mizellen beobachtet. In FaSSIF - 7C, zerstörten Tenside in höherer Konzentration die Liposomenstruktur trotz der allgemeinen Stabilisierung der Membranen durch Cholesterin. rnDie in dieser Arbeit vorgestellten Ergebnisse ergeben, dass die Anwesenheit von Cholesterin als eine fehlende Komponente der menschlichen Darmflüssigkeit in biorelevanten Medien wichtig ist und dazu beitragen kann, das in vivo Verhalten schwerlöslicher Arzneistoffe im Körper besser vorhersagen zu können. Der Verdünnungsgrad hat einen Einfluss auf die Nanopartikel-Struktur und Tenside beeinflussen die Löslichkeit von Medikamenten in biorelevanten Medien: Dieser Effekt ist sowohl von der Konzentration das Tensids abhängig, als auch dessen Typ.rnrn

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Trabalho Final do Curso de Mestrado Integrado em Medicina, Faculdade de Medicina, Universidade de Lisboa, 2014