927 resultados para Cutaneous circulation


Relevância:

60.00% 60.00%

Publicador:

Resumo:

The interaction between local and reflexive control of skin blood flow (SkBF) is unclear. This thesis isolated the roles of rectal (Tre) and local (Tloc) temperature on forearm SkBF regulation at normal and elevated body temperatures, and to investigate the interaction between local and reflexive SkBF control. While either normothermic (Tre ~37.0°C) or hyperthermic (∆Tre +1.1°C), SkBF was assessed on the dorsal aspect of each forearm in 10 participants while Tloc was manipulated in an A-B-A-B fashion between neutral (33.0°C) and hot (38.5°C). Finally, local heating to 44°C was performed to elicit maximal SkBF. Data are presented as a percentage of maximal cutaneous vascular conductance (CVC), calculated as laser-Doppler flux divided by mean arterial pressure. Tloc manipulations performed during normothermia had significantly greater effects on CVC than during hyperthermia. The decreased modification to SkBF from the Tloc changes during hyperthermia suggests that strong reflexive vasodilation attenuates local SkBF control mechanisms.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Nos últimos anos, a circulação cutânea surgiu como uma janela interessante para analisar a função microcirculatória e os mecanismos de disfunção. Tecnologias não-invasivas, incluindo a Fluxometria por Laser Doppler (FLD), gasimetria transcutânea e a Perda Transepidérmica de Água (PTEA), ajudaram a considerar a circulação cutânea como um modelo de translação útil na doença vascular. Neste estudo procurou-se avaliar o perfil de resposta de um grupo de indivíduos jovens saudáveis ​​(n = 8), de ambos os sexos (24,5 ± 0,8 anos de idade) a três manobras de condicionamento da perfusão no membro inferior - A: elevação da perna enquanto sentado, B: elevação da perna enquanto em decúbito dorsal; C: oclusão supra-sistólica com um torniquete. As técnicas de medição incluiram FLD, pressões parciais transcutâneas (tc) pO2 e pCO2 por gasimetria e PTEA por evaporimetria. Foram aplicados testes de estatística descritiva e não paramétrica, sendo adotado um nível de confiança de 95%. As tcpO2 e tcpCO2 alteraram-se significativamente durante as manobras. Foi registado um perfil de evolução recíproca para FLD e PTEA em A e C, o que pode sugerir que, sob as condições experimentais as condições de perfusão local podem influenciar a função epidérmica "barreira". Os modelos propostos parecem ser adequados para caracterizar a microcirculação periférica in vivo, o que justifica estudos de desenvolvimento posteriores.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A microcirculação cutânea surgiu, nos últimos anos, como uma alternativa pratica e acessível para o estudo da circulação periférica. Técnicas não-invasivas, como a Fluxometria por Laser Doppler (FLD), a Evaporimetria e a Gasimetria transcutânea em associação a testes de provocação têm transformado a circulação cutânea num atraente modelo de investigação. Este estudo foi aplicado a um grupo de voluntárias jovens saudáveis (n = 8, (21,6 ± 2,6) anos) respirando uma atmosfera de 100 % oxigénio durante 10 minutos. Este teste permitiu-nos avaliar a resposta circulatória na microcirculação do membro inferior. As técnicas de medição incluíram o fluxo sanguíneo local por FLD, a pO2 transcutânea (tc) e a Perda Transepidérmica de Água (PTEA) por evaporimetria. A análise de dados revela que tc-pO2 e FLD se alteraram significativamente durante o teste. Um perfil de evolução recíproca foi registrado para FLD e PTEA, que parece apoiar dados anteriores de que as alterações no fluxo sanguíneo local podem influenciar a função de “barreira” epidérmica. Este modelo parece adequado para caracterizar a microcirculação do membro inferior in vivo.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION: Breaching the skin's stratum corneum barrier raises the possibility of the administration of vaccines, gene vectors, antibodies and even nanoparticles, all of which have at least their initial effect on populations of skin cells. AREAS COVERED: Intradermal vaccine delivery holds enormous potential for improved therapeutic outcomes for patients, particularly those in the developing world. Various vaccine-delivery strategies have been employed, which are discussed in this review. The importance of cutaneous immunobiology on the effect produced by microneedle-mediated intradermal vaccination is also discussed. EXPERT OPINION: Microneedle-mediated vaccines hold enormous potential for patient benefit. However, in order for microneedle vaccine strategies to fulfill their potential, the proportion of an immune response that is due to the local action of delivered vaccines on skin antigen-presenting cells, and what is due to a systemic effect from vaccines reaching the systemic circulation, must be determined. Moreover, industry will need to invest significantly in new equipment and instrumentation in order to mass-produce microneedle vaccines consistently. Finally, microneedles will need to demonstrate consistent dose delivery across patient groups and match this to reliable immune responses before they will replace tried-and-tested needle-and-syringe-based approaches.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Wound healing, angiogenesis and hair follicle maintenance are often impaired in the skin of diabetic patients, but the pathogenesis has not been well understood. Here, we report that circulation levels of kallistatin, a member of the serine proteinase inhibitor (SERPIN) superfamily with anti-angiogenic activities, were elevated in Type 2 diabetic patients with diabetic vascular complications. To test the hypothesis that elevated kallistatin levels could contribute to a wound healing deficiency via inhibition of Wnt/β-catenin signaling, we generated kallistatin-transgenic (KS-TG) mice. KS-TG mice had reduced cutaneous hair follicle density, microvascular density, and panniculus adiposus layer thickness as well as altered skin microvascular hemodynamics and delayed cutaneous wound healing. Using Wnt reporter mice, our results showed that Wnt/β-catenin signaling is suppressed in dermal endothelium and hair follicles in KS-TG mice. Lithium, a known activator of β-catenin via inhibition of glycogen synthase kinase-3β, reversed the inhibition of Wnt/β-catenin signaling by kallistatin and rescued the wound healing deficiency in KS-TG mice. These observations suggest that elevated circulating anti-angiogenic serpins in diabetic patients may contribute to impaired wound healing through inhibition of Wnt/β-catenin signaling. Activation of Wnt/β-catenin signaling, at a level downstream of Wnt receptors, may ameliorate the wound healing deficiency in diabetic patients.Journal of Investigative Dermatology accepted article preview online, 24 January 2014. doi:10.1038/jid.2014.40.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mock circulation loops are used to evaluate the performance of cardiac assist devices prior to animal and clinical testing. A compressible, translucent silicone ventricle chamber that mimics the exact size, shape and motion of a failing heart is desired to assist in flow visualization studies around inflow cannulae during VAD support. The aim of this study was therefore to design and construct a naturally shaped flexible left ventricle and evaluate its performance in a mock circulation loop. The ventricle shape was constructed by the use of CT images taken from a patient experiencing cardiomyopathic heart failure and used to create a 3D image and subsequent mould to produce a silicone ventricle. Different cardiac conditions were successfully simulated to validate the ventricle performance, including rest, left heart failure and VAD support.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Heart disease is attributed as the highest cause of death in the world. Although this could be alleviated by heart transplantation, there is a chronic shortage of donor hearts and so mechanical solutions are being considered. Currently, many Ventricular Assist Devices (VADs) are being developed worldwide in an effort to increase life expectancy and quality of life for end stage heart failure patients. Current pre-clinical testing methods for VADs involve laboratory testing using Mock Circulation Loops (MCLs), and in vivo testing in animal models. The research and development of highly accurate MCLs is vital to the continuous improvement of VAD performance. The first objective of this study was to develop and validate a mathematical model of a MCL. This model could then be used in the design and construction of a variable compliance chamber to improve the performance of an existing MCL as well as form the basis for a new miniaturised MCL. An extensive review of literature was carried out on MCLs and mathematical modelling of their function. A mathematical model of a MCL was then created in the MATLAB/SIMULINK environment. This model included variable features such as resistance, fluid inertia and volumes (resulting from the pipe lengths and diameters); compliance of Windkessel chambers, atria and ventricles; density of both fluid and compressed air applied to the system; gravitational effects on vertical columns of fluid; and accurately modelled actuators controlling the ventricle contraction. This model was then validated using the physical properties and pressure and flow traces produced from a previously developed MCL. A variable compliance chamber was designed to reproduce parameters determined by the mathematical model. The function of the variability was achieved by controlling the transmural pressure across a diaphragm to alter the compliance of the system. An initial prototype was tested in a previously developed MCL, and a variable level of arterial compliance was successfully produced; however, the complete range of compliance values required for accurate physiological representation was not able to be produced with this initial design. The mathematical model was then used to design a smaller physical mock circulation loop, with the tubing sizes adjusted to produce accurate pressure and flow traces whilst having an appropriate frequency response characteristic. The development of the mathematical model greatly assisted the general design of an in vitro cardiovascular device test rig, while the variable compliance chamber allowed simple and real-time manipulation of MCL compliance to allow accurate transition between a variety of physiological conditions. The newly developed MCL produced an accurate design of a mechanical representation of the human circulatory system for in vitro cardiovascular device testing and education purposes. The continued improvement of VAD test rigs is essential if VAD design is to improve, and hence improve quality of life and life expectancy for heart failure patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There is increasing epidemiological and molecular evidence that cutaneous melanomas arise through multiple causal pathways. The purpose of this study was to explore the relationship between germline and somatic mutations in a population-based series of melanoma patients to reshape and refine the divergent pathway model for melanoma. Melanomas collected from 123 Australian patients were analyzed for melanocortin-1 receptor (MC1R) variants and mutations in the BRAF and NRAS genes. Detailed phenotypic and sun exposure data were systematically collected from all patients. We found that BRAF-mutant melanomas were significantly more likely from younger patients and those with high nevus counts, and were more likely in melanomas with adjacent neval remnants. Conversely, BRAF-mutant melanomas were significantly less likely in people with high levels of lifetime sun exposure. We observed no association between germline MC1R status and somatic BRAF mutations in melanomas from this population. BRAF-mutant melanomas have different origins from other cutaneous melanomas. These data support the divergent pathways hypothesis for melanoma, which may require a reappraisal of targeted cancer prevention activities.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In vitro cardiovascular device performance evaluation in a mock circulation loop (MCL) is a necessary step prior to in vivo testing.A MCL that accurately represents the physiology of the cardiovascular system accelerates the assessment of the device’s ability to treat pathological conditions. To serve this purpose, a compact MCL measuring 600 ¥ 600 ¥ 600 mm (L ¥ W¥ H) was constructed in conjunction with a computer mathematical simulation.This approach allowed the effective selection of physical loop characteristics, such as pneumatic drive parameters, to create pressure and flow, and pipe dimensions to replicate the resistance, compliance, and fluid inertia of the native cardiovascular system. The resulting five-element MCL reproduced the physiological hemodynamics of a healthy and failing heart by altering ventricle contractility, vascular resistance/compliance, heart rate, and vascular volume. The effects of interpatient anatomical variability, such as septal defects and valvular disease, were also assessed. Cardiovascular hemodynamic pressures (arterial, venous, atrial, ventricular), flows (systemic, bronchial, pulmonary), and volumes (ventricular, stroke) were analyzed in real time. The objective of this study is to describe the developmental stages of the compact MCL and demonstrate its value as a research tool for the accelerated development of cardiovascular devices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Planning on utilization of train-set is one of the key tasks of transport organization for passenger dedicated railway in China. It also has strong relationships with timetable scheduling and operation plans at a station. To execute such a task in a railway hub pooling multiple railway lines, the characteristics of multiple routing for train-set is discussed in term of semicircle of train-sets' turnover. In programming the described problem, the minimum dwell time is selected as the objectives with special derive constraints of the train-set's dispatch, the connecting conditions, the principle of uniqueness for train-sets, and the first plus for connection in the same direction based on time tolerance σ. A compact connection algorithm based on time tolerance is then designed. The feasibility of the model and the algorithm is proved by the case study. The result indicates that the circulation model and algorithm about multiple routing can deal with the connections between the train-sets of multiple directions, and reduce the train's pulling in or leaving impact on the station's throat.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mock circulation loops (MCLs) are used to evaluate cardiovascular devices prior to in-vivo trials; however they lack the vital autoregulatory responses that occur in humans. This study aimed to develop and implement a left and right ventricular Frank-Starling response in a MCL. A proportional controller based on ventricular end diastolic volume was used to control the driving pressure of the MCL’s pneumatically operated ventricles. Ventricular pressure-volume loops and end systolic pressure-volume relationships were produced for a variety of healthy and pathological conditions and compared with human data to validate the simulated Frank-Starling response. The non-linear Frank-Starling response produced in this study successfully altered left and right ventricular contractility with changing preload and was validated with previously reported data. This improvement to an already detailed MCL has resulted in a test rig capable of further refining cardiovascular devices and reducing the number of in-vivo trials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The most common human cancers are malignant neoplasms of the skin. Incidence of cutaneous melanoma is rising especially steeply, with minimal progress in non-surgical treatment of advanced disease. Despite significant effort to identify independent predictors of melanoma outcome, no accepted histopathological, molecular or immunohistochemical marker defines subsets of this neoplasm. Accordingly, though melanoma is thought to present with different 'taxonomic' forms, these are considered part of a continuous spectrum rather than discrete entities. Here we report the discovery of a subset of melanomas identified by mathematical analysis of gene expression in a series of samples. Remarkably, many genes underlying the classification of this subset are differentially regulated in invasive melanomas that form primitive tubular networks in vitro, a feature of some highly aggressive metastatic melanomas. Global transcript analysis can identify unrecognized subtypes of cutaneous melanoma and predict experimentally verifiable phenotypic characteristics that may be of importance to disease progression.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although germline mutations in CDKN2A are present in approximately 25% of large multicase melanoma families, germline mutations are much rarer in the smaller melanoma families that make up most individuals reporting a family history of this disease. In addition, only three families worldwide have been reported with germline mutations in a gene other than CDKN2A (i.e., CDK4). Accordingly, current genomewide scans underway at the National Human Genome Research Institute hope to reveal linkage to one or more chromosomal regions, and ultimately lead to the identification of novel genes involved in melanoma predisposition. Both CDKN2A and PTEN have been identified as genes involved in sporadic melanoma development; however, mutations are more common in cell lines than uncultured tumors. A combination of cytogenetic, molecular, and functional studies suggests that additional genes involved in melanoma development are located to chromosomal regions 1p, 6q, 7p, 11q, and possibly also 9p and 10q. With the near completion of the human genome sequencing effort, combined with the advent of high throughput mutation analyses and new techniques including cDNA and tissue microarrays, the identification and characterization of additional genes involved in melanoma pathogenesis seem likely in the near future.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The presence of large number of single-phase distributed energy resources (DERs) can cause severe power quality problems in distribution networks. The DERs can be installed in random locations. This may cause the generation in a particular phase exceeds the load demand in that phase. Therefore the excess power in that phase will be fed back to the transmission network. To avoid this problem, the paper proposes the use of distribution static compensator (DSTATCOM) that needs to be connected at the first bus following a substation. When operated properly, the DSTATCOM can facilitate a set of balanced current flow from the substation, even when excess power is generated by DERs. The proposals are validated through extensive digital computer simulation studies using PSCAD and MATLAB.