998 resultados para Cryptococcal antigen test


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cryptococcus spp. commonly causes infection in immunocompromised hosts. Clinical presentation of cryptococcal meningoencephalitis (CM) is variable, but headache, fever and a high intracranial pressure should suggest the diagnosis. The cryptococcal antigen test is a specific and sensitive rapid test that can be performed on blood or cerebrospinal fluid. We report a case of CM in a patient with previously undetected lymphocytopenia. Because cryptococcal antigen test results were negative, diagnosis and treatment were delayed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

SUMMARYAIDS-related cryptococcal meningitis continues to cause a substantial burden of death in low and middle income countries. The diagnostic use for detection of cryptococcal capsular polysaccharide antigen (CrAg) in serum and cerebrospinal fluid by latex agglutination test (CrAg-latex) or enzyme-linked immunoassay (EIA) has been available for over decades. Better diagnostics in asymptomatic and symptomatic phases of cryptococcosis are key components to reduce mortality. Recently, the cryptococcal antigen lateral flow assay (CrAg LFA) was included in the armamentarium for diagnosis. Unlike the other tests, the CrAg LFA is a dipstick immunochromatographic assay, in a format similar to the home pregnancy test, and requires little or no lab infrastructure. This test meets all of the World Health Organization ASSURED criteria (Affordable, Sensitive, Specific, User friendly, Rapid/robust, Equipment-free, and Delivered). CrAg LFA in serum, plasma, whole blood, or cerebrospinal fluid is useful for the diagnosis of disease caused by Cryptococcusspecies. The CrAg LFA has better analytical sensitivity for C. gattii than CrAg-latex or EIA. Prevention of cryptococcal disease is new application of CrAg LFA via screening of blood for subclinical infection in asymptomatic HIV-infected persons with CD4 counts < 100 cells/mL who are not receiving effective antiretroviral therapy. CrAg screening of leftover plasma specimens after CD4 testing can identify persons with asymptomatic infection who urgently require pre-emptive fluconazole, who will otherwise progress to symptomatic infection and/or die.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to validate the rapid lateral flow Helicobacter pylori stool antigen test (One step H. pylori antigen test, ACON laboratories, San Diego, USA; Prime diagnostics, São Paulo), using 13C-Urea Breath Test as the gold standard for H. pylori infection diagnosis. A total of 98 consecutive patients, asymptomatic or dyspeptic, entered the study. Sixty-nine were women, with a mean age of 45.76 ± 14.59 years (14 to 79 years). In the H. pylori-positive group, the rapid stool antigen test detected H. pylori antigen in 44 of the 50 positive patients (sensitivity 88%; 95% CI: 75.7-95.5%), and six false-negative; and in the H. pylori-negative group 42 presented negative results (specificity 87.5%; 95% CI: 74.7-95.3%), and six false-positive, showing a substantial agreement (Kappa Index = 0.75; p < 0.0001; 95% CI: 0.6-0.9). Forty four of fifty patients that had positive stool antigen were H. pylori-positive, the PPV of the stool antigen test was 88% (95% CI: 75.7-95.5%), and 42 patients with negative stool antigen test were H. pylori-negative, the NPV of the stool antigen test was 87.5% (95% CI: 74.7-95.3%). We conclude that the lateral flow stool antigen test can be used as an alternative to breath test for H. pylori infection diagnosis especially in developing countries.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Detection of cryptococcal antigen in serum or cerebrospinal fluid allows cryptococcal meningitis diagnosis within few hours with >90% sensitivity. In an HIV-positive patient with Cryptococcus neoformans meningitis, initial antigen detection by immunoagglutination was negative. We thus evaluated a new immunochromatographic detection assay that exhibited a higher sensitivity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Fever is a frequent cause of medical consultation among returning travelers. The objectives of this study were to assess whether physicians were able to identify patients with influenza and whether the use of an influenza rapid diagnostic test (iRDT) modified the clinical management of such patients. METHODS: Randomized controlled trial conducted at 2 different Swiss hospitals between December 2008 and November 2012. Inclusion criteria were 1) age ≥18 years, 2) documented fever of ≥38 °C or anamnestic fever + cough or sore throat within the last 4 days, 3) illness occurring within 14 days after returning from a trip abroad, 4) no definitive alternative diagnosis. Physicians were asked to estimate the likelihood of influenza on clinical grounds, and a single nasopharyngeal swab was taken. Thereafter patients were randomized into 2 groups: i) patients with iRDT (BD Directigen A + B) performed on the nasopharyngeal swab, ii) patients receiving usual care. A quantitative PCR to detect influenza was done on all nasopharyngeal swabs after the recruitment period. Clinical management was evaluated on the basis of cost of medical care, number of X-rays requested and prescription of anti-infective drugs. RESULTS: 100 eligible patients were referred to the investigators. 93 patients had a naso-pharyngeal swab for a PCR and 28 (30%) swabs were positive for influenza. The median probability of influenza estimated by the physician was 70% for the PCR positive cases and 30% for the PCR negative cases (p < 0.001). The sensitivity of the iRDT was only 20%, and specificity 100%. Mean medical cost for the patients managed with iRDT and without iRDT were USD 581 (95%CI 454-707) and USD 661 (95%CI 522-800) respectively. 14/60 (23%) of the patients managed with iRDT were prescribed antibiotics versus 13/33 (39%) in the control group (p = 0.15). No patient received antiviral treatment. CONCLUSION: Influenza was a frequent cause of fever among these febrile returning travelers. Based on their clinical assessment, physicians had a higher level of suspicion for influenza in PCR positive cases. The iRDT used in this study showed a disappointingly low sensitivity and can therefore not be recommended for the management of these patients. TRIAL REGISTRATION: ClinicalTrials.gov NCT00821626.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Cryptococcus neoformans causes meningitis and disseminated infection in healthy individuals, but more commonly in hosts with defective immune responses. Cell-mediated immunity is an important component of the immune response to a great variety of infections, including yeast infections. We aimed to evaluate a specific lymphocyte transformation assay to Cryptococcus neoformans in order to identify immunodeficiency associated to neurocryptococcosis (NCC) as primary cause of the mycosis.Methods: Healthy volunteers, poultry growers, and HIV-seronegative patients with neurocryptococcosis were tested for cellular immune response. Cryptococcal meningitis was diagnosed by India ink staining of cerebrospinal fluid and cryptococcal antigen test (Immunomycol-Inc, SP, Brazil). Isolated peripheral blood mononuclear cells were stimulated with C. neoformans antigen, C. albicans antigen, and pokeweed mitogen. The amount of H-3-thymidine incorporated was assessed, and the results were expressed as stimulation index (SI) and log SI, sensitivity, specificity, and cut-off value (receiver operating characteristics curve). We applied unpaired Student t tests to compare data and considered significant differences for p<0.05.Results: The lymphotoxin alpha showed a low capacity with all the stimuli for classifying patients as responders and non-responders. Lymphotoxin alpha stimulated by heated-killed antigen from patients with neurocryptococcosis was not affected by TCD4+ cell count, and the intensity of response did not correlate with the clinical evolution of neurocryptococcosis.Conclusion: Response to lymphocyte transformation assay should be analyzed based on a normal range and using more than one stimulator. The use of a cut-off value to classify patients with neurocryptococcosis is inadequate. Statistical analysis should be based on the log transformation of SI. A more purified antigen for evaluating specific response to C. neoformans is needed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Cryptococcus neoformans causes meningitis and disseminated infection in healthy individuals, but more commonly in hosts with defective immune responses. Cell-mediated immunity is an important component of the immune response to a great variety of infections, including yeast infections. We aimed to evaluate a specific lymphocyte transformation assay to Cryptococcus neoformans in order to identify immunodeficiency associated to neurocryptococcosis (NCC) as primary cause of the mycosis. Methods: Healthy volunteers, poultry growers, and HIV-seronegative patients with neurocryptococcosis were tested for cellular immune response. Cryptococcal meningitis was diagnosed by India ink staining of cerebrospinal fluid and cryptococcal antigen test (Immunomycol-Inc, SP, Brazil). Isolated peripheral blood mononuclear cells were stimulated with C. neoformans antigen, C. albicans antigen, and pokeweed mitogen. The amount of H-3-thymidine incorporated was assessed, and the results were expressed as stimulation index (SI) and log SI, sensitivity, specificity, and cut-off value (receiver operating characteristics curve). We applied unpaired Student t tests to compare data and considered significant differences for p<0.05. Results: The lymphotoxin alpha showed a low capacity with all the stimuli for classifying patients as responders and non-responders. Lymphotoxin alpha stimulated by heated-killed antigen from patients with neurocryptococcosis was not affected by TCD4+ cell count, and the intensity of response did not correlate with the clinical evolution of neurocryptococcosis. Conclusion: Response to lymphocyte transformation assay should be analyzed based on a normal range and using more than one stimulator. The use of a cut-off value to classify patients with neurocryptococcosis is inadequate. Statistical analysis should be based on the log transformation of SI. A more purified antigen for evaluating specific response to C. neoformans is needed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: Fever is one of the most commonly seen symptoms in the pediatric emergency department. The objective of this study was to observe how the rapid testing for influenza virus impacts on the management of children with fever. METHODS: We performed a review of our pediatric emergency department records during the 2008/2009 annual influenza season. The BinaxNow Influenza A+B test was performed on patients with the following criteria: age 1.0 to 16.0 years, fever greater than 38.5 °C, fever of less than 96 hours' duration after the onset of clinical illness, clinical signs compatible with acute influenza, and nontoxic appearance. Additional laboratory tests were performed at the treating physician's discretion. RESULTS: The influenza rapid antigen test was performed in 192 children. One hundred nine (57%) were influenza positive, with the largest fraction (101 patients) positive for influenza A. The age distribution did not differ between children with negative and positive test results (mean, 5.3 vs. 5.1 years, not statistically significant). A larger number of diagnostic tests were performed in the group of influenza-negative patients. Twice as many complete blood counts, C-reactive protein determinations, lumbar punctures, and urinalyses were ordered in the latter group. CONCLUSIONS: Rapid diagnosis of influenza in the pediatric emergency department affects the management of febrile children as the confirmation of influenza virus infection decreases additional diagnostic tests ordered.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose. To evaluate the use of the Legionella Urine Antigen Test as a cost effective method for diagnosing Legionnaires’ disease in five San Antonio Hospitals from January 2007 to December 2009. ^ Methods. The data reported by five San Antonio hospitals to the San Antonio Metropolitan Health District during a 3-year retrospective study (January 2007 to December 2009) were evaluated for the frequency of non-specific pneumonia infections, the number of Legionella Urine Antigen Tests performed, and the percentage of positive cases of Legionnaires’ disease diagnosed by the Legionella Urine Antigen Test.^ Results. There were a total of 7,087 cases of non-specific pneumonias reported across the five San Antonio hospitals studied from 2007 to 2009. A total of 5,371 Legionella Urine Antigen Tests were performed from January, 2007 to December, 2009 across the five San Antonio hospitals in the study. A total of 38 positive cases of Legionnaires’ disease were identified by the use of Legionella Urinary Antigen Test from 2007-2009.^ Conclusions. In spite of the limitations of this study in obtaining sufficient relevant data to evaluate the cost effectiveness of Legionella Urinary Antigen Test in diagnosing Legionnaires’ disease, the Legionella Urinary Antigen Test is simple, accurate, faster, as results can be obtained within minutes to hours; and convenient because it can be performed in emergency room department to any patient who presents with the clinical signs or symptoms of pneumonia. Over the long run, it remains to be shown if this test may decrease mortality, lower total medical costs by decreasing the number of broad-spectrum antibiotics prescribed, shorten patient wait time/hospital stay, and decrease the need for unnecessary ancillary testing, and improve overall patient outcomes.^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cryptococcosis is one of the most common opportunistic fungal infections in patients with acquired immunodeficiency syndrome (AIDS). We report 13 cases of cryptococcal infection based on histopathology, serology and cultures. Epidemiological analysis, histochemical techniques of hematoxilin and eosin (HE) and Grocot's silver (GMS), as well special histochemical techniques such as Mayer's mucicarmine (MM) and Fontana-Masson (FM), cryptococcal antigen test (CrAg) and isolation on fungal media: Sabouraud's (SAB), brain-heart infusion agar (BHI) and canavanine-glycine-bromothymol blue (CGB) agar were analyzed. Unsatisfactory staining results by MM stain associated to negative titers by CrAg test, which FM stain confirmed that capsule-deficient Cryptococcus infections were observed in four cases. Eight isolated cases were identified as follows: six cases were infection with Cryptococcus neoformans and two cases were Cryptococcus gattii.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To determine the efficacy and toxicity of SCH 39304 in the treatment and suppression of cryptococcal meningitis, we conducted a prospective, noncomparative study in three groups of patients: patients with acute cryptococcal meningitis, patients with acute cryptococcal meningitis in whom other therapies have failed (salvage), and patients who required maintenance therapy. As primary therapy, the patients received up to 14 days or 1 g of amphotericin B followed by SCH 39304 200 mg once daily for 12 weeks. As maintenance therapy, the patients received SCH 39304 600 mg once weekly for 12 months. Of five salvage patients, none completed the study. Two patients died, two patients clinically deteriorated, and one patient was noncompliant. Two of three patients with acute cryptococcal meningitis completed the 12-week primary therapy, and one patient was discontinued from therapy because of a skin rash (95% confidence interval, 14-100%). All four patients who were receiving weekly maintenance therapy followed up to 27 weeks were clinically stable with no change in their serum cryptococcal antigen titer from baseline when the study was prematurely terminated. Elevation of liver function test results developed in three patients and skin rash developed in one patient. The unique pharmacologic and pharmacokinetic properties of SCH 39304 (low incidence of toxicity, long serum half-life, and good penetration into the cerebrospinal fluid) lend promise to pursue other triazole antifungals at higher doses as primary therapy and less frequent dosing for maintenance therapy.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Serum samples from 242 HIV-positive persons were studied for the detection of capsular polysaccha-ride antigen of Cryptococcus neoformans; 193 of these patients presented less than 300 CD4+ cells/µl of blood and 49 patients had more than 300 CD4+ cells/µl. None of them had symptoms or signs characteristic of cryptococcosis. The capsular antigen of C. neofarmans was detected by latex agglutination technique with pronase pre-treatment (IMMY, Crypto-Latex Antigen Detection System, Immunomycologics Inc., OK, USA); in 61% of the samples, ELISA technique was also used (Premier, Cryptococcal Antigen, Meridian Diagnostic Inc., Cincinatti, Oh, USA). The comparative study of both methods showed that the results obtained were similar in 96.9% of the cases. The capsular antigen was detected in 13 out of 193 (6.7%) patients with less than 300 CD4+ cells/µl. Cryptococcosis was confirmed mycologically in 3 of these 13 cases (23%) by the isolation of C. neoformans in CSF or blood cultures. Three patients, who had presented negative results of both tests for capsular antigen, suffered disseminated cryptococcosis 4 to 8 months later. The predictive diagnostic value of capsular antigen detection of C. neoformans seems tobe low and we believe that it should not be done routinely in asymptomatic HIV-positive persons.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

An enzyme-linked immunosorbent assay was standardized for the detection of cryptococcal antigen in serum and cerebrospinal fluid. The system was evaluated in clinical samples from patients infected by human immunodeficiency virus with and without previous cryptococcosis diagnosis. The evaluated system is highly sensitive and specific, and when it was compared with latex agglutination there were not significant differences. A standard curve with purified Cryptococcus neoformans antigen was settled down for the antigen quantification in positive samples.